Cole-Parmer Instrument Company

Similar documents
Cole-Parmer Instrument Company

ph/orp 300 (Cat. No ) MICROCOMPUTER BASED OPERATION MANUAL ph /ORP/ Temperature CONTROLLER Phone: , Fax:

Operation Manual TX10 1/8 DIN Microcomputer Based ph/orp Controller

Operation Manual MODEL 3621 JENCO ELECTRONICS, LTD. Microcomputer Based ph/orp Controller MANUFACTURER OF PRECISION INSTRUMENTS

Operation Manual MODEL 3631 JENCO ELECTRONICS, LTD. Microcomputer Based ph/orp Transmitter MANUFACTURER OF PRECISION INSTRUMENTS

Operation Manual CX10 1/8 DIN Microcomputer Based Conductivity/Resistivity Controller

Operation Manual CX20 1/8 DIN Microcomputer Based Conductivity/Resistivity Controller

Operation Manual MODEL 2TX. 2-wire Isolated ph/orp Transmitter

JENCO INSTRUMENTS, INC. JENCO ELECTRONICS, LTD.

Operation Manual. Hand-held ph/mv/temperature Meter. ph6810

OPERATION MANUAL MODEL TT-LP

JENCO ELECTRONICS,LTD. MANUFACTURER OF PRECISION INSTRUMENTS

JENCO ELECTRONICS, LTD. MANUFACTURER OF PRECISION INSTRUMENTS

Operating Instructions

OPERATION MANUAL. ph 500 (Cat. No ) MICROCOMPUTER BASED ph / Temperature TRANSMITTER & CONTROLLER

Operation Manual. MODEL ph6175. Microcomputer Based ph/orp/temperature Benchtop Meter

Operation Manual. Hand-held ph/orp/temperature Meter 6010M

Operations Manual EcoSense ph100

JENCO ELECTRONICS, LTD. MANUFACTURER OF PRECISION INSTRUMENTS

Operation Manual. MODEL ph 630. Microcomputer Based ph&temperature Pocket Meter. ph630

Operations Manual EcoSense ph100a

User Manual DOCUMENT #601119REF. EcoSense ph1000a. ph, mv (ORP), and Temperature Benchtop Meter USER MANUAL. English

WalkLAB ph mv/orptemperature

4801P ph/orp controller

User's Guide. 1/16 th DIN ph Controller. Model 48PH2. Introduction

Operation Manual. Hand-held Conductivity/Salinity/TDS/ Temperature Meter 3010M

Operation Manual MODEL 3173/3173R. MICROCOMPUTER BASED Conductivity/Salinity/TDS &Temperature BENCH METER 3173/3173R

Colorado Series. CR-10 Portable ph / mv / Temperature Meter Operation Manual

Operation Manual. MODEL ph/ec80. Microcomputer Based ph/condctivity/tds/ Sanility & Temperature Pocket Meter. ph/ec80

Operating Instructions

Microprocessor ph/orp Controller

Platinum RTD Thermometer MODEL NO

Global Water Instrumentation, Inc.

JENCO ELECTRONICS, LTD. MANUFACTURER OF PRECISION INSTRUMENTS

ph, ORP, and TDS ORP Continuous Monitor OPERATING INSTRUCTIONS 8. Warranty 9. Return of Goods

Platinum RTD Thermometer MODEL NO

ph, mv and Temperature Instrument

Dissolved Oxygen Meter Kit DOK. Instruction Manual

OPERATION MANUAL. JENCO MODEL 6312 CTB MICROCOMPUTER BASED Conductivity/TDS & Temperature TRANSMITTER & CONTROLLER

Instruction Manual. αlpha TDS /8 DIN Total Dissolved Solids Controller with Temperature display and Transmitter. 68X rev 0 08/2002

Signet ph/orp Transmitter * *

Water Quality Meter. Water Quality Meter Kit. Instruction Manual

AquaShock ph Meter K

ph/orp Meter SD Card real-time Datalogger

Analyzer/Controller. ph/orp HART. Model 54e ph/orp ESSENTIAL INSTRUCTIONS WARNINGS RISK OF ELECTRICAL SHOCK

+GF+ SIGNET ph/orp Transmitter Instructions

INSTRUCTION MANUAL. Portable ph and ph/ise Meters. Models 210Aplus 230Aplus 250Aplus 290Aplus

24-hour Continuous Field Monitors

INSTRUCTION MANUAL ORP-METER MODEL COR-01


TX ph/mv Transmitter/Controller

Industrial. Laboratory and Field. Accessories. Product Selection Guide. Analyzers 1 Controllers 2 Transmitters 3 Monitors 4

OPERATING MANUAL TCAT-2DF CONTROLLER PHYSITEMP INSTRUMENTS INC. 154 Huron Avenue Clifton NJ USA Tel: Fax:

HI HI N HI HI

1/32-DIN TEMPERATURE CONTROLLER INSTALLATION, WIRING AND OPERATION MANUAL FORM 3882

Thermo Scientific Orion Star A214 Benchtop ph/ise Meter. Instruction Sheet

MP-2000 Dual Channel LVDT/RVDT Readout/Controller

FLS M9.06 PH/ORP MONITOR. safety instructions. packing List

User Guide. ExStik FL700. Fluoride Meter

DFI 7000 DIGITAL FORCE INDICATOR USER S GUIDE 1.0 INTRODUCTION 2.0 DESCRIPTION. 2.1 Configuration. 2.2 Specifications

Thermo Scientific Orion Star A325 Portable ph/conductivity Meter. Instruction Sheet

Thermo Scientific Orion Star A324 Portable ph/ise Meter. Instruction Sheet

Economical Rugged Series M1300K

USER MANUAL AD331 AD332 Waterproof Portable Meters for EC and TDS Measurements

Operation Manual. MODEL ph 618N. Microcomputer Based ph & Temperature Pocket Meter. ph618n

ph 500 & mv 600 Series

Manual No Revision MODEL GLI-9835 HAND-HELD/PORTABLE CONDUCTIVITY/TDS METER

Instruction Manual Temp JKT Temperature Meter Series

Contents. 1. Installation

HAND-HELD THERMOCOUPLE THERMOMETER SERVICE MANUAL. CATALOG NUMBERS , and , and PROPRIETARY

INSTRUCTION MANUAL. ph/mv CONTROLLER/RECORDER

FLS M9.06. ph/orp MONITOR

HI 3220 HI 3221 HI 3222

Instruction Manual. PC 700 ph/mv/conductivity/ºc/ºf Bench Meter. Technology Made Easy...

HI ma Simulator

HI ma Simulator

User's Guide. Extech AM A AC Analog Clamp Meter

Bante 221 Portable ph/orp Meter. Instruction Manual BANTE INSTRUMENTS CO., LTD

Tempco Instruction Manual

1875 Smart Calibrator. Instruction Manual

MULTI- PARAMETER TESTER

Instruction Manual. ph 700 ph/mv/ C/ F Bench Meter. Ion 700 ph/mv/ion/ C/ F Bench Meter. Technology Made Easy...

INSTRUCTION MANUAL. Digivac 760 Series. Models 100Led P / P / 29.9" 100Led 760 / SixVac 801 / 760 / 2c 801 Micro

HI 504. Panel-mounted, Microprocessor-based ph/orp Process Controller. Instruction Manual

PH450 Analyzer Proper Calibration Steps

Datalogging ph Meter

PIECAL 322 Automated Thermocouple Calibrator Operating Instructions. Product Description. Practical Instrument Electronics

USER MANUAL AD 3000 EC/TDS/Temperature Bench Meter

WalkLAB HC Professional Conductivity-TDS-Salinity Meter. Operations Manual 15,0,11,4,1,14,5,10,13,2,9,6,3,12,7,8

Professional Benchtop Conductivity meter BC3020

Thermo Scientific Orion Star A329 Portable ph/ise/conductivity/rdo/do Meter. Instruction Sheet

DICKSON TC200/TH300 DICKSON. Handheld Temperature and Temperature / RH Indicators. Useful Features. Applications & Product. Specifications.

HI HI HI HI HI HI 98185

WK7200. Water Quality Test Kit USER S MANUAL

Instruments and Capabilities (Panel Mount and Standalone) By: Thornton Leading Pure Water Analytics

HI HI N HI HI

User Guide. ExStik TM Model RE300 Waterproof ORP Meter. Patent Pending RE300 ORP

Congratulations! Your new minichem-ph monitor is the latest in simple, reliable process monitoring instrumentation. With correct operation and

Thermo Scientific Orion Star A326 Portable ph/rdo/do Meter. Instruction Sheet

The Economy Conductivity Benchtop Meter

Transcription:

Operating Instructions Cole-Parmer ph/orp 400 ph/orp Controller Cole-Parmer Instrument Company 625 East Bunker Court, Vernon Hills, Illinois 60061 Tel: 1-847-549-7600 or Toll-free: 1-800-323-4340 Fax: 1-847-247-2949 www.coleparmer.com

CONTENTS GENERAL INTRODUCTION... 3 INITIAL INSPECTION... 3 USING THE ph/orp 400... 4 a. Mounting procedure... 4 b. Front panel... 6 c. LCD screen... 9 d. Rear connectors... 12 e. Measure mode... 14 f. Setting mode... 16 g. ph calibration mode... 23 1

h. RmV calibration mode... 26 i. Controlling the relays... 27 j. 4~20mA output... 29 ERROR DISPLAY AND TROUBLESHOOTING... 32 ph BUFFERS... 37 SPECIFICATIONS... 39 WARRANTY... 42 2

GENERAL INTRODUCTION Thank you for selecting the Cole-Parmer ph/orp 400. The ph/orp Controller is a rugged microprocessor based instrument assembled in a watertight 1/8 DIN case, designed for use in laboratories and process control applications. The system displays ph or ORP or Temperature and relay status in one large LCD screen. The ph/orp 400 is equipped with 2 control relays and an isolated 4-20mA analog output. All control relays are programmable and hysteresis driven. INITIAL INSPECTION Carefully unpack the unit and accessories. Inspect for damages made in shipment. If any damage is found, notify your Cole-Parmer representative immediately. All packing materials should be saved until satisfactory operation is confirmed. 3

USING THE ph/orp 400 a. Mounting Procedure PANEL CUTOUT 92.0± 0.813 0.000 3.622"± 0.032 0.000 45.0± 0.61 0.00 1.772"± 0.024 0.000 Make a cutout on any panel, with a thickness of 1/16 inch (1.5mm) to 3/8 inch (9.5mm). Refer to DRAWING 1. DRAWING 1 Remove the mounting assembly from the controller and insert the controller into the cutout. Refer to DRAWING 2. DRAWING2 4

Panel Mounting brackets Replace the mounting bracket assembly onto the controller and secure the controller to the mounting panel. Refer to DRAWING 3. DRAWING3 Note : If the equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may be impaired. 5

USING THE ph/orp 400 b. Front Panel The front panel consists of a 4-digit LCD display and 4 keys. HI1 ph MODE STAND SLOPE 7.00 ATC ENTER [ MODE ] key: 1a. In Measure mode, pressing and releasing the [MODE] key will show in sequence the 4 measure mode displays: ph, Temperature, ORP absolute mv, ORP relative mv. 6

1b. In Calibration or Setting mode, pressing the [MODE] key will move back to Measure mode. [UP] key: 2a. In RmV Calibration mode, pressing the [UP] key will increment the shown value. 2b. In the Setting mode, pressing the [UP] key will show the next option o r i n c r e m e n t t h e s h o w n v a l u e. 2c. In the Measure mode, pressing the [UP] key and [ENTER] key at the same time will enter Calibration mode. 2e. In Temperature Measure mode, if the Temperature Compensation select is in MANUAL mode, pressing the [UP] key will increment the shown value. 7

[DOWN] key: 3a. In RmV Calibration mode, pressing the [DOWN] key will decrement the shown value. 3b. In the Setting mode, pressing the [DOWN] key will show the previous option o r d e c r e m e n t t h e s h o w n v a l u e. 3c. In the Measure mode, pressing the [DOWN] key and [ENTER] key at the same time will enter Setting mode. 3e. In Temperature Measure mode, if the Temperature Compensation select is in MANUAL mode, pressing the [DOWN] key will increment the shown value. [ENTER] key: 4a. In Calibration mode, pressing the [ENTER] key will continue the calibration 8

process. 4b. In Setting mode, pressing the [ENTER] key will savethe new settings. If no change has been made then pressing this key will just skip the saving and move to the next setting. c. LCD Screen 1 2 3 4 5 6 CAL HI1 HI2 LOW1 LOW2 ma ph Rmv STANDSLOPE 6.86 7.00ATCMAN 7 8 9 10 11 12 13 14 9

1. CAL This icon will be displayed if the meter is in Calibration or Setting mode. 2. HI1 & LOW1 These icons, when displayed, indicate relay action and relay number. 3. HI2 & LOW2 These icons, when displayed, indicate relay action and relay number. 4. ma This icon will indicate that the unit is in 4mA or 20mA Setting mode 5. Temperature unit display. 6. ph Unit indicator. 7. STAND This icon will blink after switching-over to ph Calibration mode and also indicates the start of Buffer 1 calibration. The icon will stop blinking and stay on while Buffer 1 is being calibrated. 8. SLOPE This icon will blink to indicate the start of Buffer 2 calibration. The icon will 10

stop blinking and stay on while Buffer 2 is being calibrated. 9. 6.86 The 6.86 buffer group: 6.86, 4.00, 9.18. 10. 7.00 The 7.00 buffer group: 7.00, 4.01, 10.01. 11. ATC This icon will be displayed when any ATC probe is selected as the temperature source in the Setting Mode. 12. MAN This icon will be displayed when manual temperature is selected as the temperature source in the Setting Mode. 13. RmV Relative ORP mv unit indicator. 14. The 7-segment display. 11

d. Rear Connectors REF V+ V- 10k TH Pt 1000 INPUT L N 100~230VAC 1relay 2relay ma- ma+ The ph/orp400 can accept between 100 and 240 VAC at 50/60 Hz. Make sure to connect the AC power cord to the correct AC terminals. 12

Connect the proper load to the output relays. Make sure that the load does not exceed the relay rating of 5 Amp at 115 VAC and 2.5 Amp at 230 VAC. The V+(+3.3VDC) and V- (-3.3VDC) outputs are provided as source of excitation voltage for the ph/orp pre-amplifier only. Note : Make sure that the power is unplugged before wiring your probes, relay etc. Connecting incorrectly may damage the unit permanently. 13

e. Measure Mode Turning on the unit will always display in Measure mode. This instrument is designed to provide 4 distinct measurements: Press and release the [MODE] key to display each of the measurements. See figure below. ph MODE MODE mv MODE MODE Rmv 14

ph The degree of acidity or alkalinity of the solution. Temperature Current temperature of the solution. ORP mv A measurement of absolute ORP mv. ORP RmV A measurement of relative ORP mv. The offset value at the RmV calibration will be added to the ORP absolute value to display the ORP relative value. 15

f. Setting Mode Pressing [DOWN] key and [ENTER] key at the same time will enter the Setting mode. + ENTER CAL CAL CAL ATC ATC MAN ENTER ENTER ENTER Temperature compensation select Pressing [UP] key or [DOWN] key will cycle the display from 01 (Thermistor: 10k ohm), 02 (Resistor: PT1000) 03 (Manual) modes as shown above. Select the preferred temperature compensation mode, press [ENTER] key to save and move to the next setting screen. 16

ph buffer 1 select: ENTER ph ph ENTER ENTER Relay/mA control select Pressing [UP] key or [DOWN] key will cycle the display from 7.00 and 6.86 buffer as shown. Select your preferred buffer group, press [ENTER] key to save, and move to the next setting screen. 17

Relay/mA control select: ph buffer 1 select ENTER CAL ph CAL CAL mv Rmv ENTER ENTER ENTER Relay 1 High / Low select Pressing [UP] key or [DOWN] key in this screen will cycle the display from ph ORP mv, ORP RmV modes shown above. Select the preferred mode, press [ENTER] key to save, and move to the next setting screen. Note : The relay and ma output will only be affected by the chosen option. 18

Relay 1 High / Low select: relay/ma control select select CAL HI1 CAL LOW1 ENTER ENTER Pressing [UP] key or [DOWN] key in this screen will cycle the display from HI1 and LOW2 modes. Select the preferred mode, press [ENTER] key to save, and move to the next setting screen. Relay 1 set point value Note : See i. Controlling the relays page. 19

Relay 1 set point value: CAL CAL ph ph Blink value Rmv Rmv ENTER Relay 1 hysteresis value SP and the value of the option will blink alternately to indicate that this is the set point option, once you press the [UP] or [DOWN] keys to adjust, only the value will blink so as not to distract the user with the alternating SP screen while changing the value. Press the ENTER key to save or skip, and move to the next setting screen. 20

Relay 1 hysteresis value: CAL CAL ph ph Blink value Rmv Rmv ENTER Relay 2 Setting HYS and the value of the option will blink alternately to indicate that this is the hysteresis option, once you press the [UP] or [DOWN] keys to adjust, only the value will blink so as not to distract the user with the alternating HYS screen while changing the value. Press the ENTER key to save or skip, and move to the next setting screen. Relay 2 High / Low select: See instructions for Relay 1 High/Low select. Relay 2 set point value: See instructions for Relay 1 set point value. 21

Relay 2 hysteresis value: See instructions for Relay 1 hysteresis value. 4 ma output setting: CAL ma CAL ph Blink value Rmv ENTER 20mA setting 4 and the value of the option will blink alternately to indicate that this is the 4 ma option, once you press the [UP] or [DOWN] keys to adjust, only the value will blink so as not to distract the user with the alternating 4 screen while adjusting the value. Press the ENTER key to save or skip, and move to the next setting screen. 22

20 ma output setting: CAL ma CAL ph Blink value Rmv ENTER return 20 and the value of the option will blink alternately to indicate that this is the 20 ma option, once you press the [UP] or [DOWN] keys to adjust, only the value will blink so as not to distract the user with the alternating 20 screen while adjusting the value. Press the ENTER key to save or skip, and return to Measure mode. g. ph Calibration Mode The ph/orp 400 uses a 2-point calibration for ph. The first point must be 6.86 (if using 6.86 buffer group)/ 7.00(if using 7.00 buffer group), and the second point can either be 4.00 or 9.86 (if 6.86 buffer group) or 4.01 or 10.01 ( if using 7.00 buffer group). In the ph Measure mode, pressing [UP] key and [ENTER] key at the same time will 23

enter ph Calibration mode. Buffer 1 (STAND) calibration: CAL ph ENTER CAL ph STAND 7.00 ATC STAND 7.00 ATC After entering ph Calibration mode, the STAND icon will blink indicating the probe is ready to be standardized at the first buffer. Rinse the ph and ATC/Temp probes in distilled water and immerse them in the first buffer solution (either 7.00 or 6.86). Allow temperature reading to stabilize, then press [ENTER] key to calibrate. The ph icon will blink until the unit detects a stable reading. Once the unit calibrates the first point, the 24

SLOPE icon will blink to indicate the unit is ready to calibrate the 2 nd buffer. Buffer 2 (SLOPE) calibration: CAL ph CAL ph ENTER SAVE return Measure mode STAND SLOPE 7.00 ATC STAND SLOPE 7.00 ATC Rinse the ph and ATC/Temp probe in distilled water and immerse them in the second buffer solution (either 4.00/9.18 or 4.01/10.01). During the second point calibration the unit can automatically detect the corresponding ph buffer solution (4.00 or 9.18 if 6.86 buffer group) or (4.01 or 10.01 if 7.00 buffer group). Allow the temperature reading to stabilize, then press ENTER key to calibrate. The ph icon will blink until the unit detects a stable reading. Once the unit calibrates the second point the unit will automatically exit the Calibration mode and goes back to ph Measure mode. The 25

2- point ph calibration is complete. Note : If the user is calibrating ph without a temperature probe, first go to Setting mode (1. Temperature compensation select), select 03 (Manual temperature compensation mode) and save. Go to Measure mode Temperature display and use the UP and DOWN keys to adjust the value to the approximate temperature value of the buffer solutions before starting the ph Calibration. h. RmV Calibration Mode CAL CAL +ENTER Rmv Rmv Rmv ENTER return Measure mode 26

The ph/orp 400 uses 1-point calibration for RmV. In the RmV Measure mode, pressing [UP] key and [ENTER] key at the same time will enter RmV Calibration mode. Rinse the ORP probe in distilled water and immerse it in the ORP standard solution, then press [UP] or [DOWN] key and adjust the ORP value to the ORP standard solution value. Press the [ENTER] key to save. The unit beeps to indicate a successful calibration. Calibration is now complete and the unit will automatically switch back to Measure mode in ORP relative mv. i. Controlling the Relays Isolation voltage: The maximum isolation voltage of the relay output contacts is 1500 VDC. The voltage differential between the relay output contacts and the load should not exceed 1500 VDC. 27

Output load: The current through the relay output contacts should not exceed 5 Amp at 115 VAC and 2.5 Amp at 230 VAC in order not to cause permanent damage to the relay contacts. This rating is specified for resistive loads only. Relay action, relay set point and hysteresis value: Relay Action Effective RELAY-ON Set Point Effective RELAY-OFF Set Point HI S.P. + (1/2 H.V) S.P. (1/2 H.V) LOW S.P. (1/2 H.V) S.P. + (1/2 H.V.) S.P. = Relay Set point H.V. = Hysteresis value (Dead Band) If the relay action is set to HIGH, the relay will turn ON at (Set Point +1/2 Hysteresis ), and will turn OFF at (Set Point -1/2 Hysteresis ). If the relay action is set to LOW, the relay will turn ON at (Set Point -1/2 Hysteresis ), and will turn OFF at (Set Point +1/2 Hysteresis ). 28

There are two Independent relays the user can bind to the ph, ABSOLUTE mv or RELATIVE mv mode (Temperature not included). The user can only bind the two relays to one of three measure modes at a time. The user can change this anytime by changing Relay control parameters select at the Setting mode. j. 4-20 ma output Isolation voltage: The maximum isolation voltage of the 4-20mA output contacts is 500 VDC. The voltage differential between the 4-20mA output contacts and the load should not exceed 500 VDC. Output load: The maximum load is 500 ohm. Output current inaccuracies may occur for load impedance in excess of 500 ohm. 29

The analog output will produce a linear analog output. The user can only bind the ANALOG OUTPUT to one reading at a time. The user can change this anytime by changing option at the Calibration/Setting mode screen. The analog output will be restricted on the 4 ma setting, 20 ma setting and the current bound display. 20mA 20mA 4mA Adjustabe Bandwidh set point ph/opr 4mA set point Adjustabe Bandwidh ph/opr Decreasing current for increasing ph or ORP Increasing current for increasing ph or ORP The above figure shows the relationship between Reading, U4mA & U20mA. The analog output is based on the following equation: 30

ma(output) = 4mA+(16mA)*(D U4mA ) / (U20mA- U4mA) Where: ma(output) D U4mA = analog output = current bound display = user setting for 4 ma for current bound display U20mA = user setting for 20 ma for current bound display Note : The set point range for ph is -2.00 to 16.00 ph. The set point range for absolute mv is 1999 to 1999 mv. The set point range of for relative mv is -2999 to 2999 mv. 31

ERROR DISPLAY AND TROUBLESHOOTING ph/orp Display Temperature Display Display Mode Possible cause(s) [Action(s)] "OvEr" -10.0~120.0 C ph measure mode ph > 16.00pH [Recalibrate] undr -10.0~120.0 C ph measure mode ph < -2.00pH [Recalibrate] 32

"OvEr" "OvEr" ph measure mode a. Temperature > 120.0 C. [Bring buffer solution to lower temperature.] [Replace temperature probe.] b. No temperature sensor. [Adjust the manual temperature to -10~120 C.] 33

"OvEr" undr ph measure mode a. Temperature < -10.0 C. [Bring buffer solution to higher temperature.] [Replace temperature probe.] b. No temperature sensor. [Adjust the manual temperature to-10~120 C.] "OvEr" Temperature reading Absolute ORP mv or relative ORP Absolute ORP mv > +1999 mv [Bring solution to a lower ORP reading] "undr" Temperature reading Absolute ORP mv or relative ORP Absolute ORP mv < -1999 mv [Bring solution to a higher ORP reading] 34

ORP reading "OvEr" Absolute ORP mv or relative ORP a. Temperature > 120.0 C. [Bring buffer solution to lower temperature.] [Replace temperature probe.] b. No temperature sensor. [Adjust the manual temperature to -10~120 C.] ORP reading "undr" Absolute ORP mv or relative ORP a. Temperature < -10.0 C. [Bring buffer solution to higher temperature.] [Replace temperature probe.] b. No temperature sensor. [Adjust the manual temperature to -10~120 C.] 35

"OvEr" 0~60 C A. ph calibration mode, buffer 1 calibration (7.00 buffer group) B. ph calibration mode, buffer 1 calibration (6.86 buffer group) C. ph calibration mode, buffer 2 calibration A. Offset < -100 or > 100 mv B. Offset < -91.7 or > 108.3 mv C. Slope > ideal slope by 30% or slope < ideal slope by 30% [Use a new buffer solution.] [Replace electrode.] 36

ph BUFFERS The temperature characteristics of ph calibration buffers ph4.00, ph4.01, ph6.86, ph7.00, ph9.18 & ph10.01 are stored inside the instrument. The buffers used to calibrate the instrument must exhibit the same temperature characteristics as the stored values. C 4.00 6.86 9.18 4.01 7.00 10.01 0 4.01 6.98 9.46 4.01 7.11 10.32 5 4.00 6.95 9.39 4.01 7.08 10.25 10 4.00 6.92 9.33 4.00 7.06 10.18 15 4.00 6.90 9.28 4.00 7.03 10.12 20 4.00 6.88 9.23 4.00 7.01 10.06 25 4.00 6.86 9.18 4.01 7.00 10.01 30 4.01 6.85 9.14 4.01 6.98 9.97 35 4.02 6.84 9.10 4.02 6.98 9.93 37

40 4.03 6.84 9.07 4.03 6.97 9.89 45 4.04 6.83 9.04 4.04 6.97 9.86 50 4.06 6.83 9.02 4.06 6.97 9.83 55 4.07 6.83 8.99 4.08 6.97 9.80 60 4.09 6.84 8.97 4.10 6.98 9.78 Note : The actual reading of the instrument can differ from the values shown by ±0.01 ph. 38

SPECIFICATIONS Mode Range Resolution Accuracy ph -2.00 to 16.00 ph 0.01 ph ±0.1% ± 1 digit ORP Absolute mv -1999 to 1999 mv 1 mv ±0.1% ± 1 digit ORP Relative mv -2999 to 2999 mv 1 mv ±0.1% ± 1 digit Temperature -10.0 to 120.0 C 0.1 C ±0.3 C ph: Recognized ph buffers ph Temperature compensation US (4.01, 7.00, 10.00) or NIST (4.00, 6.86, 9.18) Manual/Auto -10.0 C to 120.0 C ph Buffer Temperature range 0.0 C to 60.0 C ph Electrode Offset recognition ±100 mv at ph 7.00 +108.3 mv/-91.7 mv at ph 6.86 39

ph Electrode Slope recognition ±30% at ph 4.00, 4.01, 9.18, 10.01 Input impedance >10 12 Calibration end point sensing Yes Temperature: Temperature sensor ( User selectable) Thermistor(10k ohm at 25 C), Resistor (PT1000) or Manual Controller: Control type Relay output (Resistive load only) Two ON/OFF control 5 A at 115 VAC or 2.5 A at 220 VAC 4-20 ma Output: Output range 40 4 to 20 ma (isolated)

Output scale Maximum load Accuracy Isolation voltage user programmable 500 ohm ±0.03 ma 500 VDC General: Keys Power: Audio feedback in all keys 100 VAC to 240 VAC, 50/60Hz Ambient Temperature range 0.0 to 50.0 C Case Weight IP65, 1/8DIN case, depth 90mm 290 g 41

WARRANTY The Cole-Parmer Instrument Company warrants this product to be free from significant deviations in material and workmanship for a period of one year. If repair or adjustment is necessary and has not been the result of abuse or misuse, within the twelve month period, please return, freight-prepaid, and correction will be made without charge (see note on return of items). Cole-Parmer alone will determine if the product problem is due to deviations or customer misuse. Out of warranty products will be repaired for a nominal charge. 42

RETURN OF ITEMS Authorization must be obtained from our Customer Service Department before returning items for any reason. When applying for authorization, please include data regarding the reason the items are to be returned. A restocking charge will be made on all unauthorized returns. For your protection, items being returned must be carefully packed to prevent damage in shipment and insured against possible damage or loss. Cole-Parmer will not be responsible for damage resulting from careless or insufficient packing. Note : The Cole-Parmer Instrument Company reserves the right to make improvements in design, construction and appearance of our products without notice. We stand behind our products. For additional information on our products, warranty, or returns please contact our office or visit our website listed on front page. 43