INSTALL INSTRUCTIONS RSXMR-9886-P-48 Installation Instructions RSXMR-9886-P-48 (CEQ. 20194)
INSTALL INSTRUCTIONS RSXMR-9886-P-48 Contents Section Description Page 1 Copyright 2 1.1 Disclaimer 2 1.2 Warnings 2 2 Introduction 3 3 OVP Package Contents 3 3.1 Prerequisites 3 3.2 Tools 3 4. OVP Definitions 4 5.1 Bracket Installation 4 6.1 Port Definitions 5 6.2 PRIOR TO Cable Installation 5 7 Installing Ground Cable 6 8 Installing Alarm Cable 6 9 Installing DC IN Cables 7 10 Installing DC OUT Cables 7 11 Closing and Securing Unit 8 Page 1 of 8
RSXMR-9886-P-48 INSTALL INSTRUCTIONS 1.0 Copyright Raycap, Inc. 2018 - All Rights Reserved 1.1 Disclaimer The information in this document is subject to change without notice and describes only the product defined in the introduction of this documentation. This documentation is intended for the use of Raycap customers only for the purposes of the agreement under which the document is submitted, and no part may be used, reproduced, modified or transmitted in any form or means without the prior written permission of Raycap. The documentation has been prepared to be used by professional and properly trained personnel, and the customer assumes full responsibility when using it. Raycap welcomes customer comments as part of the process of continuous development and improvement of the documentation. Raycap has made all reasonable efforts to ensure that the instructions contained in this document are adequate and free of material errors and omissions. Raycap will, if deemed necessary explain issues which may not be covered by this document. The contents of this document are subject to revision without notice due to continued progress in methodology, design and manufacturing. Raycap shall have no liability for any error damage of any kind resulting from the use of this document. 1.2 Warnings Please read this manual prior to use to become familiar with the product s numerous features and operating procedures. To maintain the maximum degree of safety, follow the sequences as outlined. Before using the product, read all instructions and cautionary markings on the product and on any equipment connected to the product. CAUTION Unless otherwise noted, product usage that is not recommended or sold by the product manufacturer can result in risk of fire, electric shock, or injury to persons. CAUTION Do not operate the product if it has been damaged in any way. Return damaged products to their manufacturer for repair or replacement. CAUTION Do not disassemble the product as incorrect reassembling can risk electrical shock or fire. WARNING Disconnect or disable the DC power source to the product prior to beginning its installation. Ensure that the DC power source to the product remains de-energized until the completion of the installation and after all connections have been verified to be correctly configured. For conditions other than those described above, please contact a Raycap Account Representative at (208) 777-1166, (800) 890-2569 or Thank you for choosing quality products from Raycap. Page 2 of 8
INSTALL INSTRUCTIONS RSXMR-9886-P-48 2.0 Introduction Radio to the RRH is provided through copper cables traveling from the base station to the top of the tower or roof top. This creates a conductive path, making the active equipment at the top and the base of the site vulnerable to damage by direct lightning strikes. Protection systems must be able to withstand direct lightning currents in order to protect the sensitive equipment. Raycap s RRH solutions featuring Strikesorb SPD technology significantly enhance the reliability & availability of the RRH site by providing superior electrical protection. 3.0 OVP Package Contents 2 each Enclosure with mounting bracket Crimp-on male barrel connectors (18-22AWG) 3.1 Prerequisites This Document describes how to install the RSXMR-9886-P-48 on-site. Installers of Raycap s RRH surge protective and fiber/power management solutions must be industry professionals who have attended training on the proper installation of the equipment by Raycap and/or the mobile operator. Installers are required to read this installation guide thoroughly prior to installation of the Raycap RRH protection equipment. 3.2 Tools #1 Flat blade screwdriver #1 Philips screw driver Jewelers flate blade screwdriver (for alarm installation) Crimping tool 3/8" wrench Drill Drill bits that are the exact size of each cable to be installed Cable stripping tool Page 3 of 8
RSXMR-9886-P-48 INSTALL INSTRUCTIONS OVP Definitions 4. Mounting Hole (4 Places) ø 0.25 [6.4] 5.51 [140] Mechanical Lug 2-14 AWG 4.33 [110] Alarm Connectors 12 to 22 AWG Bracket Installation 1 each clamping range 0.18-0.39 [4.5-10] 5.1 For POLE mounting: Using a stainless steel banding 2 each strap, clamping attach range mounting bracket to pole 0.75-1.10 per [19-28] AT&T specifications. Note: All cable glands are provided with solid plug to be customized by customer For WALL mounting: Attach mounting bracket to wall inch [mm] using 2 holes shown. 3 each clamping range 0.28-0.51 [7-13] 5.2 Secure bracket to unit by connecting with 4 screws and nuts as shown using Philips screwdriver and 3/8 wrench. Page 4 of 8
INSTALL INSTRUCTIONS RSXMR-9886-P-48 Port Definitions 6.1 See illustration to identify Base Port Assembly Definitions. PRIOR TO Cable Installation DC IN Alarm Ground DC OUT Note: If unit is to be installed outdoors, all cables MUST be outdoor rated. 6.2 Identify and match cable to appropriate gland port. (Example: Ground cable to Ground Port) Read each section below for individual installation procedure PRIOR to drilling: Installing Ground Cable (Section 7.1, page 6) Installing Alarm Cable (Section 8.1, page 6) Installing DC IN Cables (Section 9.1, page 7) Installing DC OUT Cables (Section 10.1, page 7) 2½" Max Drill Depth 2½" 2" Before Drilling: 1. Match drill bit size to cable size. Drill bit should not exceed 2½" in length. This will prevent protential damage to the internal components. 2. Using a sharp drill bit, drill through rubber insert. Insert should be installed with nut tightened when drilling to ensure proper hole location and to keep insert stable while drilling. Note: Measure Twice, Drill Once! Remove gland nut to lessen pressure against rubber insert, pull cable through gland nut and then through rubber insert hole, then tighten. Page 5 of 8
RSXMR-9886-P-48 INSTALL INSTRUCTIONS Installing Ground Cable 7.1 Drill hole in ground port rubber insert. Be sure drill bit diameter matches diameter of ground cable. Note: See 6.1 and 6.2 for Port Definitions and Drilling. 7.2 Feed ground cable through gland nut and ground port. Connect to ground lug as shown. 7.3 Tighten gland nut to create proper seal around ground cable. Installing Alarm Cable 8.1 Drill hole in alarm port rubber insert. Be sure drill bit diameter matches diameter of alarm cable. Note: See 6.1 and 6.2 for Port Definitions and Drilling. 8.2 Feed alarm cable through gland nut and alarm port. 8.3 Connect alarm cable to alarm lugs according to the AT&T established color guide and Contact Points (NC, C, NO). 8.4 Tighten gland nut to create proper seal around cable. Page 6 of 8
INSTALL INSTRUCTIONS RSXMR-9886-P-48 Installing DC IN Cables 9.1 Drill hole in DC IN port rubber insert. Be sure drill bit diameter matches diameter DC IN cables. Note: See 6.1 and 6.2 for Port Definitions and Drilling. 9.2 Feed DC IN cables through gland nut and DC IN port. 9.3 Connect Supply (-48V) and Return cables to lugs according to the AT&T established color guide. Red: Supply (-48V) Black: Return 9.4 Tighten gland nut to create proper seal around DC IN cables. Installing DC OUT Cables 10.1 Drill hole in DC OUT port rubber insert. Be sure drill bit diameter matches diameter DC OUT cables. Note: See 6.1 and 6.2 for Port Definitions and Drilling. 10.2 Feed DC OUT cables through gland nut and DC OUT port. 10.3 Strip cables and insert into the provided RED male barrel connectors then crimp to secure to DC jumper cable. Supply (-48V) Return 10.4 Connect Supply (-48V) and Return by working the connectors into the pre-installed female BLUE barrel connectors. 10.5 Tighten gland nut to create proper seal around DC OUT cables. Page 7 of 8
RSXMR-9886-P-48 INSTALL INSTRUCTIONS Closing and Securing Unit 11.1 Close cover tightening and secure the four screws on the front of unit. 11.2 Installation complete. Page 8 of 8