ShadowLESS lighting systems for microscopy

Similar documents
SCHOTT EasyLED Series

ORYON RING LIGHTS. 14 in. Ring Light and 18 in. Ring Light. Quick Start Guide. What s Included

SCHOTT FLM 4 Fiber Lighting Modul. Operating Instructions

FengMi Wemax One Laser Projection TV

User Manual. Binocular Zoom Stereo Microscope with Boom Stand. MicroscopeNet.com

LED SPIDER MOVING HEAD LIGHT

TECHNICAL DATA. V-PIX Quad Bar. Product code CL-VPIX-4-40 Light colour Full spectrum 8 / 480 (see above)

Mi50 Inverted Microscope User s Manual. Fein.

Blue Weapon Laser. User manual UK. Version 1.0

Camera. Network Bullet Camera. Quick Operation Guide

Spectrum Laser. User manual UK. Version 1.0

Specifications: LED Ring Lights. Product Number

2800 ACOUSTIC SERIES BLUETOOTH BOOKSHELF SPEAKER SYSTEM USER MANUAL

LED-Illumination with Control Unit Ident.-No

Orbital smart Tunable Downlight

Network Dome Camera. Quick Start Guide

TVAC25100 TVAC25110 User manual

Home Network. .in.ua. User Manual. Video Door Phone CDV-40N.

INSPECTION TOOL. Inspection Video Camera with Color LCD Monitor. EU Environmental Protection. Model: 8802LE,8803LE. Model: 8802LE,8803LE

CONTENDER LED FRESNEL SPOT FOCUSING LIGHT USER MANUAL

DarkFX Spot 670 User Manual English

PHOS 20/40 downlight OWNER'S MANUAL

ENG. LCD Monitor Series Prestigio P TFT Active Matrix LCD Panel User s Manual. Prestigio P1910 1

Design-in guide. Philips CertaFlux SLS

BA505C 2-wire 4/20mA manual setpoint station Issue 6

ICE FOG Q TM Low Fog Generator

ESV1018 Quantum Illuminator Cabinet INSTRUCTION MANUAL

RING LIGHT. LED Strobe Indicator ON = Light Active Green Indicator LED

User Manual. GUARD STATION(Gate View System) CDS-4GS

Network Dome Camera Quick Start Guide

ESV1200 Quantum Illuminator Cabinet INSTRUCTION MANUAL

Led Illuminator and Light Stimulator. Model # LSD-1. Ver

Thank you for purchasing the CHP Assembly Tool. In order to ensure maximum performance and

650/1000 Fresnel 650/1000 PC 300/500 Antihalo 300/500 Fresnel theatre spotlight. user manual

* * Agilent Power Distribution Unit (PDU) Installation Guide

A-44-IR V2/A-54 V2 Quick Start Guide

HBO 100 Microscope Illuminating System

User Manual Shutter (T6801) and filter wheel (L981054) D / Sa

LED Ring Lights. LED Ring Lights

ClockWatch. User Manual. Cueing and Presentation Control Specialists

INSTRUCTION MANUAL HIGH CURRENT DRIVER BOARD STAND ALONE

Springtree Spatial Wash COB WW

Dome Network Camera. Quick Start Guide

A-300 Speed Dome. Quick Start Guide

dedicated KVM switch and rackmount screen technology User Manual CV-1201D DVI-D KVM Designed and manufactured by Austin Hughes

CL-15.1 OPERATION MANUAL OPTIKA

3-Lamp Fluorescent Ring Light 19" INSTRUCTIONS

Installation manual plugs and connectors with screw connection (16/32 A)

Model #28599 Wireless Bluetooth Surround Bar & Subwoofer 285W

SolConeX extra-low voltage flange socket

DSI-4. DMX Optically Isolated 1x4 Splitter. D Series. DSI_4 Users Manual r3.lwp copyright 2009, 2010, 2011 ELM V. T. Inc.

Digital Overhead Stirrer

Lyte-MV Digital Userguide Red & IR Versions

Promopar ORDERCODE 30120

Metaphase. MetaBright TM METAPHASER TM Model#: MP-LE1006 HIGH POWER LED LIGHT ENGINE. metaphase-tech.com. metaphase-tech.com. Technologies, Inc.

LVN5200A-R2, rev. 1, Hardware Installation Guide

Springtree Spatial Wash COB RGBW

User instructions Stereo microscope

Instruction Manual. Professional 1000WS Incubating. Rocking Shaker. Waving Shaker

LED Slimline PAR RGBW 7x8W

RTT2 ROOM TEMPERATURE SWITCH. Mounting and operating instructions

ESV1500 Quantum Illuminator Cabinet INSTRUCTION MANUAL

CMSA-100 Manual. Cinema Media Server Automation

4-CHANNEL DMX WALL-MOUNTED CONTROLLER

AL Dot User guide

User Guide Automatic Transfer Switch (ATS)

MANUAL Series ZOOM STEREO MICROSCOPE MANUAL

Signal processor MS96 for flow sensors MS96-11EX0-R/230VAC

Swift SM100 Series Stereo Microscope

Diffuse reflection light scanner with background suppression. Dimensioned drawing

Richter Optica. Instructions for: S6-BL, S6-TS, S6-SPS, S6-ILST Models

PT230 PONTOON THRUSTER INSTALLATION MANUAL (PATENT PENDING) VOLUME 1.2, JUNE 2015

User Manual VIDEO DOOR PHONE

USER S MANUAL English

A-55 Quick Start Guide Quick Start Guide. Camera

Omnitron Systems Technology, Inc. 1. iconverter. 19-Module Managed Power Chassis User s Manual

ibright 2X2 Flat LED Panel Family Model Performance Summary

Model 2460-KIT. Screw Terminal Connector Kit. Description / September 2014 *P * 1

User Manual COMMAX LOBBY PHONE

TURBO HD TVI Bullet & Turret Camera

C-RED 2 Quick Start Manual. C-RED 2 Quick Start_

Mounting and Operating Instructions of RP406K and RP406K-IC for mobile video surveillance

V2 LED SOFTLIGHT USER GUIDE

Dual-Feed 80A Auto Low Voltage Disconnect Panel - 80LVD02

CC186 AND CC186/2 STAND-ALONE OR SYSTEM CLOCK

Camera. Network Bullet Camera. Quick Operation Guide

RAINPROOF* COLOR CAMERA SECURITY SYSTEM

IPCB42501 / IPCB42551

User Guide. Control Box. RoscoLED TM.

STR-3 STANDARD 3-PHASE 230 VAC TRANSFORMER CONTROLLER. Mounting and operating instructions

Camera. Network Fisheye Camera. Quick Operation Guide

DC-V3213XJ-4.3mm DC-V3213XJ-2.5mm

DS-1H05 Ethernet-over-Coax Extender. User Manual

Network Camera. Quick Guide DC-T3243HRX. Powered by

Camera A14 and A34 Dome Camera

B63/ NS MS. EtherNet/IP LINK

icore Kiosk system Installation Guide

EQUIPMENT Operation Manual

M40 Microscope User s Manual

RТTH DUAL ROOM SWITCH

Transcription:

ShadowLESS lighting systems for microscopy Brightfield illumination (BF) BF-5400 BF-6500 Darkfield illumination (DF) DF-5400 DF-6500 INSTRUCTION MANUAL

CONTENTS A. GENERAL INSTRUCTIONS 1 A1. Safety instructions 1 A2. Usage instructions 2 A3. System overview 3 B. OPERATING 4 B1. Mounting and connecting 4 B2. Accessories 5 B3. Assembly of accessories 6 C. TECHNICAL DATA 8 C1. Features 8 D. MAINTENANCE 11 D1. Cleaning 11 D2. Repair 11 D3. Guarantee & customer service 11 Do Don t

A. GENERAL INSTRUCTIONS A1. Safety instructions Please read and follow these safety instructions carefully. The manufacturer is not liable for personal or material damages if the safety instructions are not followed. If these safety instructions are not observed, the safety of the product is not guaranteed. Make sure these safety instructions are always available to any user. Avoid looking directly and for a long period of time to the fiber whenever the light ring is switched on (risk of ocular damage). The fiber should not be cut or disconnected from the control unit under any circumstances. In case of a fiber break, the laser source will automatically shut down. The power supply should then be unplugged and the product should be sent back to the customer service (see section D3 Guarantee & customer service). - - Do not obstruct the laser unit ventilation. This could lead to an overheating and to a damage of the product. 1

Safety instructions (cont.) The product must not be opened or dismantled under any circumstances. It is prohibited to make any technical changes to the product. Repairs are exclusively assigned to L.E.S.S. SA. This product is not adapted for a use in explosion-hazard areas and should only be used in the conditions listed under C1.7 General conditions of use. The product must not be powered by a power supply which has not been supplied by L.E.S.S. A full disconnection from the electrical network can only be made by unplugging the power supply. A2. Usage instructions The ShadowLESS product range for microscopy (BF/DF-5400/6400) has been developed for stereo-microscopy and macroscopy. These products are conceived to be used in industrial environments or in R&D laboratories. - - The product generates visible light of high intensity. In the case of inspection of components consisting of materials that absorb visible lignt, it is recommended to adjust the distance between the light ring and the observed sample in order to avoid thermal degradation of the lighted object. 2

A3. System overview A3.1. General overview BF-5400 & 6500 1 2 DF-5400 & 6500 1. Control unit : Allows to adjust the light intensity (further details at points 3, 4, and 5). 2. Light ring : Allows a uniform lighting on the working surface without heat dissipation. A3.2. Front view of the control unit 3 4 5 3. Potentiometer : Allows to adjust the light intensity of the light ring. 4. Power socket : Power supply 9 [Vdc]. 5. Power switch : Allows to switch the light ring on or off. 3

B. OPERATING B1. Mounting and connecting B1.1. Connecting the control unit to the power supply Insert the 9 [Vdc] plug into the control unit socket (4). Plug the power supply to an electrical outlet (220 [Vac]). Warning: It is recommended to only use the optional power supply supplied by L.E.S.S. The use of any other power supply cancels the manufacturer guarantee. B1.2. Commissioning Before switching the light on and in order to avoid the user dazzle, make sure the potentiometer is adjusted on low intensity (see B.1.3 Regulating light intensity ). By pressing on the part of the switch (5) closer to the power plug (4), the lamp switches on (ON). To switch it off, press on the opposite part of the switch (OFF). 4 5 ON OFF Warning: To disconnect the light ring from the electrical network, unplug the power supply. B1.3. Regulating light intensity By turning the potentiometer (3) towards the opposite direction of the power socket (4), the light intensity increases progressively. In order to know which intensity to select before switching the light on, the wheel of the potentiometer is calibrated from 1 to 5. 3 4 Warning: When the regulator is turned towards the lowest power, it doesn t mean that the lamp is switched off. The lamp is only switched off when the switch is on the OFF position. 4

B2. Accessories The following optional accessories can be ordered to enhance the usage of the product. B2.1. Brightfield (BF) and Darkfield (DF) Power supply Available with European (EU), Japanese (JP) or British (UK) interfaces, it enables to supply the lamp with power via the electrical network. Ring adapter Available with several inner rings, it makes the illumination systems compatible with microscope objectives from 50 to 66 [mm]. Base system It allows to fix the different systems (bright- and darkfield) in a compact manner either directly on the microscope or on the workstation. B2.2. Brightfield BF-5400 & BF-6500 Diffuser BF standard Delivers smoother image when observing reflective components under high angle illumination. It can be attached and removed quickly. Diffuser BF large Delivers smoother image when observing very reflective components under high angle illumination. It can be attached and removed quickly. B2.3. Darkfield DF-5400 & DF-6500 - - Combo post It allows to adjust the height of the low angle ring light. It facilitates the precise inspection of samples at different heights ranging from 0 to 50 [mm]. 5

B3. Assembly of accessories While mounting the system, avoid tightening the screws too hard in order not to damage the screw thread or distort the objective of the microscope. Regarding the connection of the system to the electrical network, please refer to B.1. Mounting and connecting. B3.1. Brightfield BF-5400 & BF-6500 Mikroskop Assembling the ring adapter to the microscope: Insert the ring adapter around the objective of the microscope with the white clamping blocks upwards and screw the lateral black clamping screws until the adapter is stabilised. Assembling the light ring to the adapter: Insert the light ring in the adapter and stabilise it with the silver lateral clamping screw of the adapter. - - Assembling of the diffuser on the light ring: Insert the diffuser under the light ring and attach it with the lateral clamping screw of the diffuser. 6

The ShadowLESS DF-5400/6500 offers the possibility to adjust the height of the light ring, weather with respect to the objective of the microscope or with respect of the base of the microscope. B3.2. Darkfield DF-5400 & DF-6500 Mikroskop Assembling the DF ring with respect to the objective of the microscope: 1. As a first step, screw the long axe of the combo post to the threaded hole in the corner of the ring frame. 2. Then, screw the small axe of the combo post to the threaded hole in the ring adapter (at the opposite of the silver clamping screw). 2. 3. 3. Insert the ring adapter around the objective of the microscope with the white clamping blocks upwards and screw the lateral black clamping screws until the adapter is stabilised. 1. Setting the DF ring with respect to the base of the microscope : Screw the 3 adjusting screws in the holes in the frame of the light ring; positions are marked with dots on the diagram. Then, position the light ring on the base of the microscope and use the 3 screws to adjust the height and angle of the light ring. Base of the microscope 7

C. TECHNICAL DATA C1. Features C1.1. Scaling Brightfield (BF). 8

C1.2. Scaling Darkfield (DF). 9

Features (cont.) C1.3. Light Colour temperature Working distance 5 400 [K] or 6 500 [K] BF : 50-150 [mm] DF : 0-15 [mm] C1.4. Mechanics BF ring Inner diameter 66 [mm] (2.6 [inches]) External diameter 89.5 [mm] (3.5 [inches]) Hight 9 [mm] (0.4 [inches]) DF ring Inner diameter 76 [mm] (3 [inches]) External diameter 110 x 110 [mm] (4.3 [inches]) Hight 8 [mm] (0.3 [inches]) C1.5. Control unit Length Width Hight C1.6. Cable Length 70 [mm] (2.7 [inches]) 70 [mm] (2.7 [inches]) 31 [mm] (1.2 [inches]) 500 [mm] C1.7. General conditions of use Temperature 0 40 [ C] Humidity 20 80 [% HR] Protection Index IP 24 Lifetime > 20 000 hours External power supply 9 [Vdc] C1.8. Certifications CE RoHS 10

D. MAINTENANCE No maintenance is required on L.E.S.S. lighting systems. D1. Cleaning To clean the external components, use a soft and dry cloth or commercially available cleaner clothes. The use of cleaning products, alcohol or other chemical products is not recommended. D2. Repair The following table shows a set of solutions adapted to specific problems that can be encountered with the ShadowLESS systems. Failure Probable cause Solution The lamp is off The lamp flashes at ignition The product doesn t work The power supply is not plugged The line voltage is down The laser security is on Mount and connect the product according to B1.2 Commissioning. Plug the power supply according to B1. Mounting and connecting. Check the line voltage Contact L.E.S.S. to organise a product return shipment according to D3. Guarantee & customer service. In case you couldn t troublshot the failure with the above mentionned solutions, please contact the customer service as a manufacturer intervention must be made. D3. Guarantee & customer service L.E.S.S. products are guaranteed for two years from the purchase date. In case of defect, please contact our customer service before organising a return shipment to the manufacturer: L.E.S.S. SA Customer service Ch. de la Dent d Oche 1A CH-1024 Ecublens Switzerland customer-service@less-sa.com +41 21 552 07 10 11

PRECISION LIGHTING FOR PROFESSIONALS L.E.S.S. SA Chemin de la Dent d Oche, 1A CH-1024 Ecublens, Switzerland www.less-sa.com info@less-sa.com +41 21 552 07 10