User Guide. Modbus Module. For Digistart soft starters. Part Number: Issue: 3.

Similar documents
It is the installer's responsibility to follow all instructions in this manual and to follow correct electrical practice.

Copyright: December 2017 Nidec Issue: E

1. Introduction. 2. Installation MODBUS INTERFACE

MODBUS RTU MODULE INSTRUCTIONS. for use with WSIQ2/WSE

Copyright: December 2017 Nidec Issue: E

Instructions. Modbus RTU Card (WSIQ-COM-MB)

Observe all necessary safety precautions when controlling the soft starter remotely. Alert personnel that machinery may start without warning.

DeviceNet Module. User Manual. 1 Important User Information. 2 Installation

ASTAT XB/XBm Remote Operator

ETHERNET/IP & PROFINET MODULE

It is the installer's responsibility to follow all instructions in this manual and to follow correct electrical practice.

Observe all necessary safety precautions when controlling the soft starter remotely. Alert personnel that machinery may start without warning.

- 15G0078B120 - DEVICENET MODULE INSTRUCTIONS FOR ASAC-0/ASAC-1/ASAB

PROFINET MODULE. Communications module. User Guide. This manual is to be given to the end user en / a. Power. Error. Status.

- 15G0078B110 - PROFIBUS MODULE INSTRUCTIONS FOR ASAC-0/ASAC-1/ASAB

MODBUS TCP MODULE INSTRUCTIONS. for use with WSIQ2/WSE

Soft Starter Remote Operator. Section 1.0 Introduction 1.1 Important user information General Manual description...2.

Profinet Module. User Manual. Contents

Install the DeviceNet Module using the following procedure:

Ethernet/IP Module. User Manual. Contents

Copyright December 2017 Nidec Issue: D

Section 1 Caution Statements... 3 Section 2 Introduction Section 3 Basic Setup Procedure... 5 Section 4 Installation... 6

MCD 200 MCD 500. Remove the Profibus Module using the following procedure: 1. Remove power from the module.

CONTENTS IMS2 SERIES A. 2.1 Overview Feature List Part Number Format... 3

1. Installation DEVICENET INTERFACE. Install the DeviceNet Interface using the following procedure:

USERS IMS2 SERIES SOFT STARTERS

CONTENTS. Basic Setup Procedure Section 1 Caution Statements Programming and Operation IMS2 SERIES H

Section 0.0 Warnings... 2 Section 1.0 Quick Set-up... 3 Section 2.0 Description Section 3.0. Section 4.0. Section 5.0. Section 6.0. Section 7.

Section 0.0 Warnings... 3 Section 1.0 Quick Set-up... 4 Section 2.0 Description Section 3.0. Section 4.0. Section 5.0. Section 6.0. Section 7.

Installation Guide Modbus TCP Module

Installation Guide EtherNet/IP Module

THT-500-A/R (C5) 1. System Configuration COMMUNICATION INSTRUCTION MANUAL. No. THT5CE

OPERATING INSTRUCTIONS MCD

Chapter 5: Communications 5 1 SR55 Communications Overview 5 2

THERMO-CON. Model No. HECR002-A5. Keep available whenever necessary.

2. Terminal arrangement TEMPERATURE CONTROLLER KT2 COMMUNICATION INSTRUCTION MANUAL. (Fig. 2-1)

1. Introduction. 2. Installation INSTALLATION INSTRUCTIONS: MCD USB MODULE

JCL-33A (C5) Warning. 1. System Configuration COMMUNICATION INSTRUCTION MANUAL

SERIAL INTERFACE. Series SSW-05

Installation Guide PROFINET Module

Operating Guide MODBUS (RTU) Communications Option IM/L150 MOD_2. Level Indicator L150 and L160

RS485 MODBUS Module 8AO

RS485 MODBUS Module 6RO

User Guide IM/C250 MOD_3. Modbus (RTU) Communications Option C250 and V250

MCF. User's Manual. Air Flowmeter NPT Model. for Communication Functions. No. CP-SP-1301E

Optidrive Applications Support Library

INTELLIS. Modbus Direct Network Monitor

Serial CFW-11. Communication Manual. Phone: Fax: Web:

User Guide Supplement Modbus TM Serial Data Communications Option IM/C100 MOD_6. /8 DIN Process Indicators and Controllers C100, C150, C160 and V100

1. System Configuration

Installation Guide EtherNet/IP Module

Optidrive Applications Support Library

Flex Series User Guide

RSGD 75mm Modbus Protocol

AL2-MBU Advanced Manual

RS485/RS232 Communications Interface

SAFETY PRECAUTIONS. Throughout this manual we use the following two illustrations to make you aware of safety considerations:

E2 Modbus RTU Register Map Revision History Version Comments Author Date 1.02 Previous version PAE 11/06/ Revised to new format PAE 09/03/09

JCS, JCM, JCR, JCD-33A (C5)

- 15G0078B130 - USB MODULE INSTRUCTIONS FOR ASAC-0/ASAC-1/ASAB

SDM-8AO. Expansion Module 8 analog outputs. Manufactured for

Section 1.0 Description Section 2.0. Section 3.0. Section 4.0. MCD3000 DeviceNet Gateway. Contents

MCD 200 Series. MCD 200 DEVICENET Module OPERATING INSTRUCTIONS. MCD 200 DEVICENET Module. Order Code: 175G9002. Adjustment.

11 Serial Communications

SDM-6RO. Expansion Module 6 relay outputs. Manufactured for

TABLE OF CONTENTS. Communication Functions

1. System configuration

RS 485 Mini Modbus 1AO

SMART RELAY SRW 01 V4.0X

Carbon Monoxide Sensor - ModBus

Motors Automation Energy Transmission & Distribution Coatings. Profibus DP SRW 01. User s Manual

CURRENT PROTECTION RELAY SMPR-1

VD SERIES CONTROLLERS (VERSION4.0) RS-485 COMMUNICATION INSTRUCTION MANUAL MODBUS Protocol Reference Guide

Operation manual. HDOM-Profibus-V0. More options please visit;

RTD-W Installation Instructions

RS485 MODBUS Module 8I8O

Intech Micro 2300-A8VI analogue input station MODBUS RTU slave application supplementary manual.

E2 Modbus RTU Register Map

SATEL I-LINK 100 MB I/O-converter User Guide, Version 1.1

BCT SERIES CONTROLLERS (VERSION 3.0) RS-485 COMMUNICATION INSTRUCTION MANUAL MODBUS Protocol Reference Guide

DirectNET Host. Communications Programs. In This Chapter...

OPERATION MANUAL Card Reader Communication

PM290 POWERMETER. Communication Protocols ASCII & Modbus Reference Guide

RS485 MODBUS Module 16I-M

Using the MODBUS Protocol with Athena Series C (1ZC, 16C, 18C, and 25C) Controllers

IFD9503. CANopen Slave Communication Module Application Manual

isma-b-mg-ip User Manual Global Control 5 Sp. z o.o. Poland, Warsaw

T1K MODBUS Base Controller Specifications

1. Communication Data Frame

Interface Definition RISH EM 2340/1320/30/ _Rev. D - 8/2016

ABB Drives. User s Manual. Modbus Adapter Module RMBA-01

Softstarters. Type PSTX Fieldbus communication, Fieldbus Plug Modbus RTU. 1SFC132092M0201 June SFC132092M0201 1

Manual 09/11 MN Z-EN. NZM-XATS-C Automatic Transfer Switch-Controller Modbus Communication Protocol

THERMOSALD ISX RS485 MODBUS (V5) 3E S.r.l. - Via del Maccabreccia 37/a LIPPO DI CALDERARA (BOLOGNA) THERMOREGULATOR for PULSE WELDING

mbc082 Bus Converter

RS485 IO Slim Module MOD-ETH

GPD 506 / Modbus RTU Technical Manual

Opal Pro AB Ethernet IP. Opal Pro MS6 SERIES. AB Ethernet IP Interface Users Manual. Revision Page 1

Quantum III. Compact DC Drive Package. Slitter DC Drive Package. Quantum III

RS485 MODBUS Module 8I8RO

Transcription:

User Guide Modbus Module For Digistart soft starters Part Number: 477-9-3 Issue: 3

General Information The manufacturer accepts no liability for any consequences resulting from inappropriate, negligent or incorrect installation or adjustment of the optional parameters of the equipment or from mismatching the starter with the motor. The contents of this guide are believed to be correct at the time of printing. In the interests of commitment to a policy of continuous development and improvement, the manufacturer reserves the right to change the specification of the product or its performance, or the content of the guide without notice. All rights reserved. No parts of this guide may be reproduced or transmitted in any form or by any means, electrical or mechanical including, photocopying, recording or by an information storage or retrieval system, without permission in writing from the publisher. Copyright: November 211 Control Techniques Issue 3

Contents 1. Introduction... 4 2. Important User Information... 4 3. Installation... 4 3.1 Physical installation... 4 4. Modbus Module Connection and Configuration... 5 4.1 Adjustment... 5 4.2 Connection... 5 4.3 Network Status LED... 6 5. Master Configuration... 6 6. Modbus Functions... 6 6.1 Modbus Register... 7 6.2 Trip Codes... 8 6.3 Cyclic redundancy check (CRC)... 9 6.4 Examples... 9 6.5 Modbus Error Codes... 1 7. AP ASCII Protocol... 1 7.1 Commands... 11 7.2 Status Retrieval... 11 7.3 Data Retrieval... 11 7.4 Calculating the Checksum (LRC)... 12 8. Modbus Control via Remote Keypad... 12 8.1 Grounding and Shielding... 12 8.2 Termination Resistors... 12 8.3 RS485 Data Cable Connection... 13 8.4 Remote Keypad RS485 Network Connection Specifications... 13 8.5 Using the Remote Keypad with Digistart CS... 13 8.6 Programming... 14 8.7 Troubleshooting... 15 9. Specifications... 15 Modbus Module User Guide 3 Issue 3

1. Introduction Control Techniques soft starters can be controlled and monitored across an RS485 serial communication network using the Modbus RTU and AP ASCII protocols. For users requiring simple control of Digistart CS and Digistart IS soft starters using Modbus RTU or AP ASCII, the instructions below describe the installation and operation of the Modbus Module. Digistart CS soft starters can also connect to the network via a correctly configured Remote Keypad - see Modbus Control via Remote Operator for details. 2. Important User Information Observe all necessary safety precautions when controlling the soft starter remotely. Alert personnel that machinery may start without warning. It is the installer's responsibility to follow all instructions in this manual and to follow correct electrical practice. 3. Installation CAUTION Remove mains and control voltage from the soft starter before attaching or removing accessories. Failure to do so may damage the equipment. Install the Modbus Module using the following procedure: 3.1 Physical installation 1. Fully pull out the top and bottom retaining clips on the module. 2. Line up the module with the comms port slot. 3. Push in the top and bottom retaining clips to secure the module to the starter. Figure 3-1 Attach the module to the starter 1 2 3 1178.B Figure 3-2 Remove the module from the starter Remove the Modbus Module using the following procedure: 1. Remove control power and mains supply from the soft starter. 2. Disconnect all field wiring from the module. 3. Fully pull out the top and bottom retaining clips on the module. 4. Pull the module away from the soft starter. 355B 4 Modbus Module User Guide Issue 3

4. Modbus Module Connection and Configuration 4.1 Adjustment Network communication parameters must be set on the Modbus Module. DIP switch settings take effect on the power-up of the Modbus Module via the soft starter. Figure 4-1 Adjustment switches 6 A 1 2 +16 +8 +4 +2 +1 AP ASCII OFF ON RTU ON +16 +8 +4 +2 +1 7 ON 3191.B 6 B 3 4 5 48 OFF 96 OFF 192 ON 384 ON OFF ON OFF ON No Parity ODD EVEN 1 bit OFF OFF ON ON OFF ON OFF ON No Time Out 1 s 6 s 1 s OFF OFF ON ON OFF ON OFF ON Protocol Address Timeout (seconds) DIP switch Baud rate Example: Address = 24 Parity 4.2 Connection Figure 4-2 Modbus Module connections Digistart CS 1 Digistart IS 1 3 2 3 2 8649.A 865.A Digistart CS Modbus Module RS485 serial port RS485 connection onto Modbus network Digistart IS (Remote mode) DI2, +24V: Stop DI3, +24V: Reset Modbus Module RS485 serial port RS485 connection onto Modbus network For the Modbus Module to accept serial commands, a link must be fitted across terminals CSL-DI2 on the soft starter. Input links are required across the stop and reset inputs if the soft starter is being operated in Remote mode. In Local mode, links are not required. If emergency stop is not required, change the setting of Pr 3A or connect a link across C53, C54. Modbus Module User Guide 5 Issue 3

NOTE Digistart IS Pr 3O Comms in Remote selects whether the soft starter will accept Start, Stop or Reset commands from the Serial Network Master while in Remote mode. See the Digistart IS User Manual for parameter details. 4.3 Network Status LED The Network Status LED (1) indicates the state of the communications link between the module and the network. LED operation is as follows: Figure 4-3 Feedback LEDs Off On Flashing No connection or soft starter not powered up Communication active Communication inactive 1 3193.C NOTE If communication is inactive, the soft starter may trip if the Communications Timeout function has been set on the module. When communication is restored, the soft starter will require a Reset. 5. Master Configuration For standard Modbus 11-bit transmission, the Master must be configured for 2 stop bits with No Parity and 1 stop bit for odd or even parity. For 1-bit transmission, the Master must be configured for 1 stop bit. In all cases, the Master baud rate and slave address must match those set on the Modbus Module DIP switches. 6. Modbus Functions The Modbus Module supports the following Modbus functions: 3 Read multiple registers 6 Write single register 16 Write multiple registers Modbus broadcast functions are not supported. Digistart CS soft starters (including Remote Keypad): Read multiple registers 43 to 48 Write single register 42 Digistart IS soft starters: Read multiple registers starting from 43 up to a maximum of 119 register blocks. Single write single register 42 or multiple write registers 49 to 4599. NOTE A multiple read across register boundary 48/49 will result in a Modbus Error code 5 at the Master. 6 Modbus Module User Guide Issue 3

6.1 Modbus Register Table 6-1 Modbus register Register Address 42 Command 43 Starter status 44 Trip Code 45 1 Motor current 46 Motor temperature 47 Product type and version 48 Serial protocol version 49 2 Parameter manageme nt Type Description Digistart CS Single write 1 = Start 2 = Stop 3 = Reset 4 = Quick stop (coast to stop) 5 = Forced communication trip 6 = Start using Parameter Set 1 3 7 = Start using Parameter Set 2 3 Multiple read Bit Description Multiple read Multiple read Multiple read to 3 1 = Ready 2 = Starting 3 = Running 4 = Stopping (including braking) 5 = Restart delay (including Temperature check) 6 = Tripped 7 = Program mode 8 = Jog forward 9 = Jog reverse 4 1 = Positive phase sequence (only valid if bit 6 = 1) 5 1 = Current exceeds full load current 6 = Uninitialised 1 = Initialised 7 = Communications are OK 1 = Communications device fault See Trip Code table Average 3 phase motor current (A) Motor 1 temperature (thermal model) Multiple read Bit Description Multiple read Single write and multiple read to 2 Product parameter list version 3 to 7 4 = Digistart CS 8 = Digistart IS Pr 1A Motor Full Load Current to Digistart IS maximum register address (starter software dependent) Digistart IS Remote Keypad 1 For models IS43N and smaller this value will be 1 times greater than the value displayed on the keypad. 2 See the relevant soft starter literature for a complete parameter list. The first product parameter is always allocated to register 49. The last product parameter is allocated to register 4XXX, where XXX = 8 plus total number of available parameters in the product. 3 Ensure that the programmable input is not set to Motor Set Select before using this function. NOTE If Pr 3A Input A Function for Digistart IS is set to motor set select, this will cause a conflict with motor set selection via serial communications. Modbus Module User Guide 7 Issue 3

6.2 Trip Codes Table 6-2 Trip messages Trip Code 1 Excess start time 2 Motor overload (thermal model) 3 Motor thermistor 4 Current imbalance 5 Frequency (Mains supply) 6 Phase sequence 7 Instantaneous overcurrent 8 Power loss/power circuit 1 Heatsink overtemperature 11 Motor connection Tx 12 Input A trip 13 FLC too high (FLC out of range) 14 Unsupported option (function not available in inside delta) 15 Starter communication (between module and soft starter) 16 Network communication (between module and network) 17 Internal fault x (where x is the fault code detailed in the table below). 2 1 Ground fault 23 Parameter out of Range 24 Input B trip 26 L1 phase loss 27 L2 phase loss 28 L3 phase loss 29 L1-T1 shorted 3 L2-T2 shorted 31 L3-T3 shorted 32 Motor 2 overload (thermal model) 33 2 Time-overcurrent (Bypass overload) 35 Battery/clock 36 Thermistor circuit 37 RTD/PT1 A 38 1 RTD/PT1 B 39 1 RTD/PT1 C 4 1 RTD/PT1 D 41 1 RTD/PT1 E 42 1 RTD/PT1 F 43 1 RTD/PT1 G 45 RTD/PT1 X Circt 46 Analog input trip 47 Overpower 48 Underpower 255 No trip Trip Name Digistart CS Digistart IS 1 Available with Digistart IS only if the appropriate option card is fitted. 2 For Digistart IS, time-overcurrent protection is only available on internally bypassed models. 8 Modbus Module User Guide Issue 3

6.2.1 Internal Fault x The table below details the internal fault code associated with trip code 17. Table 6-3 Internal fault X Internal fault 7 Current Read Err Lx 71 72 73 Power On in Simulation mode 74 Motor connection Tx 75 76 77 Firing fail SCRx 78 79 8 VZC Fail Px 81 82 83 Low Control Volts 84 Internal fault X 85 Contact your local supplier with the fault code (X). 86 87 89 9 91 92 93 94 95 96 97 98 Message displayed on the keypad 6.3 Cyclic redundancy check (CRC) The CRC is a 16bit cyclic redundancy check using a polynomial with a value A1. The 16bit CRC is appended to the message and transmitted LSB first. The CRC is calculated on all the bytes in the frame. For further Modbus information, including the CRC calculation, refer to the Modbus protocol specifications available at http://www.modbus.org/specs.php http://www.modbus.org/specs.php. 6.4 Examples Command: Start Message Starter Address Function Code Register Address Data CRC In 2 6 42 1 CRC1, CRC2 Out 2 6 42 1 CRC1, CRC2 Starter status: Running Message Starter Address Function Code Register Address Data CRC In 2 3 43 1 CRC1, CRC2 Out 2 3 2 xxxx11 CRC1, CRC2 Trip code: Motor overload Message Starter Address Function Code Register Address Data CRC In 2 3 44 1 CRC1, CRC2 Out 2 3 2 1 CRC1, CRC2 Modbus Module User Guide 9 Issue 3

Download parameter from starter Digistart IS: Read parameter 3 (Pr 1C) Locked Rotor Time, 1 seconds Message Starter Address Function Code Register Address Data CRC In 2 3 411 1 CRC1, CRC2 Out 2 3 2 1 CRC1, CRC2 Upload parameter to starter Digistart IS: Write parameter 12 (Pr 2H), Stop Mode, set = 2 'Adaptive Control' Message Starter Address Function Code Register Address Data CRC In 2 6 42 2 CRC1, CRC2 Out 2 6 419 2 CRC1, CRC2 6.5 Modbus Error Codes Table 6-4 Error codes Code Description Example 1 Illegal function code Function other than 3 or 6 2 Illegal data address Register number invalid 3 Not readable data Register not allowed for data reading 4 Not writable data Register not allowed for data writing 5 Data boundary fault Multiple data transfer across data boundary or data size more than 125 6 Invalid command code e.g. writing "6" into 43 7 Illegal parameter read Invalid parameter number 8 Illegal parameter write Invalid parameter number, read only, or hidden parameter 9 Unsupported command Sending a serial command to Digistart IS with Pr 3O = Disable control in RMT. 1 Local communication error Communication error between Modbus slave and starter NOTE Some of the above codes are different from those defined in the Modbus Application Protocol Specification available on www.modbus.org. 7. AP ASCII Protocol The message fragments used to communicate with the Modbus Module as an AP ASCII slave device are shown below. The message fragments may be assembled into complete messages as described in the sections that follow. NOTE Data must be transmitted in 8-bit ASCII, no parity, one stop bit. Table 7-1 AP ASCII message fragments Message Fragment Type ASCII Character String or (Hexadecimal Character String) Send address EOT [4h] nn nn lrc lrc ENQ [5h] Send command STX ccc lrc ETX Send request [2h] ccc lrc [3h] Receive data STX [2h] dddd dddd lrc lrc ETX [3h] Receive status STX [2h] ssss ssss lrc lrc ETX [3h] ACK (acknowledge) ACK [6h] NAK (negative acknowledge) NAK [15h] ERR (error) BEL [7h] nn = two byte ASCII number representing the soft starter address where each decimal digit is represented by n. lrc = two byte longitudinal redundancy check in hexadecimal. ccc = three byte ASCII command number where each character is represented by c. dddd = four byte ASCII number representing the current or temperature data where each decimal digit is represented by d. ssss = four byte ASCII number. The first two bytes are ASCII zero. The last two bytes represent the nibbles of a single byte of status data in hexadecimal. 1 Modbus Module User Guide Issue 3

7.1 Commands Commands can be sent to the soft starter using the following format: Figure 7-2 Command format Send address ACK Send command ACK Possible error responses: NAK (Invalid LRC) = Master = Slave (soft starter) Command ASCII Comment Start B1 Initiates a start Stop B12 Initiates a stop Reset B14 Resets a trip state Quick stop B16 Initiates an immediate removal of voltage from the motor. Any soft stop settings are ignored. Forced communication trip B18 Causes a communications trip 7.2 Status Retrieval Soft starter status can be retrieved using the following format: Figure 7-3 Status retrieval format Send address ACK Send request Receive status Possible error responses: NAK (Invalid LRC) = Master = Slave (soft starter) Request ASCII Receive Status (ssss) Trip code C18 See the trip code table. Starter status C22 Bit Description to 3 1 = Ready 2 = Starting 3 = Running 4 = Stopping (including braking) 5 = Restart delay (including Temperature check) 6 = Tripped 7 = Program mode 4 1 = Positive phase sequence (only valid if bit 6 = 1) 5 1 = Current exceeds FLC 6 = Uninitialised 1 = Initialised 7 = Communications are OK 1 = Communications device fault 7.3 Data Retrieval Data can be retrieved from the soft starter using the following format: Figure 7-4 Data retrieval format Send address ACK Send request Receive data Possible error responses: NAK (Invalid LRC) = Master = Slave (soft starter) Modbus Module User Guide 11 Issue 3

Request ASCII Receive Data (dddd) Motor current D1 Requests motor current. The data is four byte decimal ASCII. Minimum value A, maximum value 9999 A. Motor temperature D12 Requests the calculated value of the motor thermal model as a % of motor thermal capacity. The data is four byte decimal ASCII. Minimum value is %. Trip point is 15%. 7.4 Calculating the Checksum (LRC) Each command string sent to and from the starter includes a checksum. The form used is the longitudinal redundancy check (LRC) in ASCII hex. This is an 8-bit binary number represented and transmitted as two ASCII hexadecimal characters. To calculate LRC: 1. Sum all ASCII bytes 2. Mod 256 3. 2's complement 4. ASCII convert For example Command String (Start): ASCII STX B 1 or 2h 42h 31h 3h ASCII Hex Binary STX 2h 1 B 42h 1 1 1 31h 11 1 3h 11 A5h 11 11 SUM (1) A5h 11 11 MOD 256 (2) 5Ah 11 11 1's COMPLEMENT 1h 1 + 1 = 5Bh 11 111 2's COMPLEMENT (3) ASCII 5 B ASCII CONVERT (4) or 35h 42h LRC CHECKSUM The complete command string becomes: ASCII STX B 1 5 B ETX or 2h 42h 31h 3h 35h 42h 3h To verify a received message containing an LRC: 1. Convert last two bytes of message from ASCII to binary 2. Left shift second to last byte four bits 3. Add to last byte to get binary LRC 4. Remove last two bytes from message 5. Add remaining bytes of message 6. Add binary LRC 7. Round to one byte 8. The result should be zero Response or status bytes are sent from the starter as an ASCII string: STX [d1]h [d2]h [d3]h [d4]h LRC1 LRC2 ETX d1 = 3h d2 = 3h d3 = 3h plus upper nibble of status byte right shifted by four binary places d4 = 3h plus lower nibble of status byte For example status byte = 1Fh, response is: STX 3h 3h 31h 46h LRC1 LRC2 ETX 8. Modbus Control via Remote Keypad The Modbus Module can be used to connect a Remote Operator to the soft starter, enabling control via an RS485 serial communications network. See the Remote Operator instructions for details. 8.1 Grounding and Shielding Twisted pair data cable with ground shield is recommended. The cable shield should be connected to the GND device terminal at both ends and one point of the site protective ground. 8.2 Termination Resistors In long cable runs prone to excessive noise interference, termination resistors should be installed between the data lines at both ends of the RS485 cable. This resistance should match the cable impedance (typically 12 Ω). Do not use wire wound resistors. 12 Modbus Module User Guide Issue 3

Figure 8-1 Installation with termination resistors 1 2 3 325.B Network master RS485 Remote Keypad RS485 Soft starter RS485 8.3 RS485 Data Cable Connection Daisy chain connection is recommended. This is achieved by parallel connections of the data cable at the actual device terminals. 8.4 Remote Keypad RS485 Network Connection Specifications Input impedance: 12 kω Common mode voltage range: - 7 V to + 12 V Input sensitivity: ± 2 mv Minimum differential output voltage: 1.5 V (with max loading of 54 Ω) 8.5 Using the Remote Keypad with Digistart CS Figure 8-2 Modbus Module connections 1 2 3 4 + GND - + GND - + - - GND + - GND + ~/+ ~/- Digistart CS Module RS485 serial port Remote Keypad B1, B11-4 to 2 ma analog output B1, B2, B3 - RS485 starter connection B6, B7, B8 - RS485 network connection 1, 2 - Supply voltage (18 to 3 Vac/Vdc) RS485 Serial communication network connection (Modbus RTU or AP ASCII) Modbus Module User Guide 13 Issue 3

8.6 Programming The Remote Keypad must be configured to operate on the network. In order to access Programming Mode, the Remote Keypad must be powered up when the soft starter is not running. 8.6.1 Programming Procedure 1. To enter Programming Mode, hold down the Data/Prog pushbutton for four seconds. The default value of the first parameter will be displayed. 2. Use the Data/Prog pushbutton to advance to the next parameter. 3. Use the Stop and Reset pushbuttons to adjust parameter values. Programming Mode closes when the Data/Prog pushbutton is pressed after Pr 9. NOTE There is a 2 second timeout when the Remote Operator is in Programming Mode. Programming Mode will automatically close if no input is registered for 2 seconds. Any changes already made will be saved. 8.6.2 Programmable Parameters The Remote Keypad offers the following programmable parameters: Table 8-1 Programmable parameters Parameter Number Description 1 RS485 network baud rate Default Setting 4 (96 baud) 2 = 24 baud 3 = 48 baud 4 = 96 baud 5 = 192 baud 6 = 384 baud Adjustable Range 2 RS485 network 2 1 to 99 satellite address 3 RS485 network seconds to 1 seconds timeout (= off) 4 RS485 network protocol 1 (AP ASCII) 1 = AP ASCII protocol 2 = Modbus RTU protocol 5 Modbus protocol parity (no parity) = no parity 1 = odd parity 2 = even parity 3 = 1-bit transmission 6 Motor FLC (A) 1 1 to 2868 7 Analog output 1 8 to 12 4 ma offset (%) 8 Start, Stop, Quick stop function disable = Remote Keypad and Network start, stop, quick stop function enabled. 1 = Remote Keypad start, stop, quick stop function enabled. Network start, stop, quick stop function disabled. 2 2 = Remote Keypad start, stop, quick stop function disabled. Network start, stop, quick stop function enabled. 1 3 = Remote Keypad start, stop, quick stop function disabled. Network start, stop, quick stop function disabled. 1, 2 9 Current 1 = off (required for Digistart CS) 1 = on (not suitable for Digistart CS) 1 Remote Keypad Reset pushbutton is always enabled. 2 RS485 Network reset and forced communication trip functions are always enabled. NOTE Remote Operator Pr 9 Current 1 normalises the displayed current and analog output for models IS23B to IS43N. Use Pr 9 in conjunction with Pr 6 Motor FLC as follows: 1. Set Pr 6 to a value 1 times greater than the actual motor nameplate FLC (e.g. for actual FLC = 4.6 A, set Pr 6 to 46). 2. Set Pr 9 = 1. 14 Modbus Module User Guide Issue 3

8.7 Troubleshooting The Remote Keypad display and status indication LEDs can indicate abnormal operating and system conditions. Table 8-2 Error codes Display Indication net on display SP flashing on display Problem A loss of communication has been detected on the RS485 link to the network. Soft starter is off and being programmed from the serial network. 9. Specifications Possible Solution The Remote Keypad has an RS485 Network Timeout Protection setting (Pr 3). This error is reported when no communication occurs for longer than the timeout setting. The system will become active as soon as communication is restored. To clear net from the display, press the Data/Prog pushbutton momentarily or send a Reset command from the network Master. Finish soft starter network programming procedure and exit Programming Mode. Enclosure Dimensions... 4 mm (W) x 166 mm (H) x 9 mm (D) Weight... 25 g Protection... IP2 Mounting Spring-action plastic mounting clips (x 2) Connections Soft starter... 6-way pin assembly Network... 5-way male and unpluggable female connector (supplied) Maximum cable size... 2.5 mm2 Settings Protocol... Modbus RTU, AP ASCII Address range... to 31 Data rate (bps)... 48, 96, 192, 384 Parity... None, Odd, Even, 1-bit Timeout... None (off), 1 s, 6 s, 1 s Certification C... IEC 6947-4-2 CE... IEC 6947-4-2 RoHS... Compliant with EU Directive 22/95/EC Modbus Module User Guide 15 Issue 3

477-9-3 71-89-C