Application Switchgear for industrial and advanced commercial applications. U e V AC 277/480 Y V DC 60

Similar documents
Application Switchgear for industrial and advanced commercial applications. U e V AC 240/ (per pole)

Application Switchgear for industrial and advanced commercial applications. U e V AC 240/ (per pole) I cs 7,5 ka

Miniaturecircuitbreaker(MCB),16A,3p,B-Char,AC. Application Switchgear for industrial and advanced commercial applications.

For Sales and Support call KMParts.com (866)

Application Instantaneous release response current 5-10 x In. Switching capacity Switching Capacity 15 ka (IEC/EN ) U e V AC 230/400

Motor-protective circuit-breaker, 3p, Ir=16-25A, screw connection. Product range PKZM4 motor protective circuit-breakers up to 65 A

Description Basic devices with positive operation contacts. Standards IEC/EN 60947, EN , VDE 0660, UL, CSA

Safety relay emergency stop/protective door, 24VDC/AC, 4 enabling paths

Safety relay emergency stop/protective door, 230VAC, 3 enabling paths

Safety relay emergency stop/protective door, 24V-230VDC/AC, 3 enabling paths

Safety relay emergency stop/protective door, 24VDC/AC, 3 enabling paths

15, 6" panel PC with capacitive multi-touch (PCT), 2xEthernet, 2xUSB3.0, 1xRS232, 1xRS485, Galileo Runtime License

FAZ Supplementary Protectors, FAZ Miniature Circuit Breakers, P2 Disconnect Switches Overview

ST 200 M data sheet System pro M compact miniature circuit breakers for supplementary protection acc. to UL 1077

1492-SP Supplementary Protectors

UL 489 DIN Rail Miniature Circuit Breakers

UL 489 DIN Rail Miniature Circuit Breakers

Issued February DATA SHEET 5SX2 MCB. Based on Siemens Industrial Control Catalog

1.3. Miniature Circuit Breakers and Supplementary Protectors. Contents. WMZS Circuit Breaker. UL 1077 DIN Rail Supplementary Protectors

Close Protection from Moeller. miniature branch circuit breakers miniature supplementary protectors

Miniature Circuit Breakers for Railway Applications

OTEC Miniature Circuit Breakers (MCB) OTEC Miniature Circuit Breakers (MCB) OTEC Miniature Circuit Breakers (MCB) Areas of Application

Miniature Circuit Breakers and Supplementary Protectors. Contents

Disconnect Switches. Safe Switching and Disconnecting

Product Guide. UL 1077 DIN Rail Supplementary Protectors

IEC An introduction. 28 March 2012 By Craig McKee Technical Manager

1.2. Miniature Circuit Breakers and Supplementary Protectors. Contents. WMZ Circuit Breaker. UL 489 DIN Rail Miniature Circuit Breakers

UL 489 Cable-In / Cable-Out Branch Circuit Breaker

Product Guide. UL 489 DIN rail miniature circuit breakers

Supplementary Circuit Protectors Type GSB63

Mini feed-through terminal block - MSDBV 2,5-M

TeSys IEC Contactors and Overload Relays

60103 Circuit Breaker

5/2 Product overview. 5/3 Distribution board components. 5/9 Built-in components. 5/17 Mounting components 5. Siemens ET B1 10/2009

140M C 2 E A63 KN CC GJ

Jtec 10kA Miniature Circuit Breaker

Allen-Bradley 1492-RCDA4A40

MG24434 Supplementary Protector SUPPLEMENTARY PROTECTOR, 240VAC, 16A, CIRCUIT BREAKER TYPE: STANDARD

J7MN. Ordering Information. Motor Protection Circuit Breaker. Model Number Legend. MPCB system. Options. Motor Protection Circuit Breaker J7MN I-1

OVERLOAD RELAYS POWER & ACTUATION PROVEN. series

Residual Current Devices. Residual Current Devices FRCmM-NA according to UL1053 & IEC/EN 61008

Motor protection circuit breakers

ATS01N232RT soft starter for asynchronous motor - ATS01-32 A V

PHOENIX CONTACT Features

ATS01N103FT soft starter for asynchronous motor - ATS01-3 A V KW

ATS01N206RT soft starter for asynchronous motor - ATS01-6 A V

CS8 Industrial Control Relays

UL 489 DIN rail branch circuit breakers

TeSys protection components

NF44E-.. / NFZ44E-.. Contactor Relays AC / DC Operated - with Screw Terminals

Protection Equipment

Electronic timer CT-ERD.12

AThink future. Switch to green. Mini Panel Board. Cost-effective, space-saving board up to 400A.

Selection Guide. Control Circuit and Load Protection. Allen-Bradley 1489-M2C020

RE17LAMW on-delay timing relay - 1 s..100 h V AC/ DC - solid state output

RE17LCBM off-delay timing relay - control - 1 s..100 h V - solid state output

Mini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protectors Specifications Bulletin Number 1492, 1692

24973 Circuit Breaker MINIATURE CIRCUIT BREAKER, 440VAC, 10A, CIRCUIT BREAKER TYPE: STANDARD

ATSU01N209LT soft starter for asynchronous motor - ATSU01-9 A V KW

QUINT-PS/ 1AC/24DC/ 5

QUINT-PS/1AC/24DC/10. Extract from the online catalog. Order No.:

140M C 2 N A63 KN CC GJ

RE17LAMW on-delay timing relay - 1 s..100 h V AC/DC - solid state output

K1B004TLH cam switch - 1 pole A - screw mounting

K1F037MCH cam voltmeter switch - 3L and 3L-N A - for Ø 22 mm

RM4TR31 three-phase network control relay RM4-T - range V

RM4JA01F current measurement relay RM4-J - range ma V AC

Electronic timer CT-ERS.12 ON-delayed with 1 c/o contact Data sheet

ATS22D17Q soft starter-ats22-control 220V-power 230V(4kW)/ V(7.5kW)

Solid-State Contactors

K1D012ULH cam changeover switch - 2-pole A - screw mounting

Electronic timer CT-ARS.11

RM17TG. Main. Product or component type. Product specific application. Relay monitored parameters. Switching capacity in VA

Selection Guide. Control Circuit and Load Protection

PanelView Plus/VersaView CE Terminals and Display Modules

QUINT-PS/ 1AC/24DC/20/CO

Electronic timer CT-ERS.21

Section 4 Ground-Fault Protection Devices

Control Circuit and Load Protection Products

Datasheet - SRB 402EM-24V

Electronic timer CT-AHD.22

02/11/2015

DeltaV Bulk Power Supplies

SR2B201FU compact smart relay Zelio Logic - 20 I O V AC - clock - display

Miniature Circuit-Breaker IEC Series 8562

RiLine Compact The smart power distribution system

RM4TA32 three-phase network control relay RM4-T - range V

Bulletin 1489 Circuit Breakers. Selection Guide

ATS22D17Q soft starter-ats22-control 220V-power 230V (4kW)/ V(7.5kW)

XCKJ10541H29 limit switch XCKJ - th.plastic roller lever var. length - 1NC+1NO - snap - M20

K1D004ACH cam switch - 4-pole A - for Ø 22 mm

DX 3 MCB A / 16 ka 80 A to 125 A (1,5 module per pole)

RE22R2KMR Off-delay Timing Relay s 10min V AC/DC - 2C/O

Datasheet - SRB 301LC/B-24V

RE22R2QGMR Star-Delta Timing Relay s 300h V AC/DC - 2C/O

ZBRN1 access point- 2 RJ V AC/DC-4 displays-5 LEDs-Eth-Modbus-wireless radio

DIN Series MINIATURE CIRCUIT BREAKERS, RESIDUAL CURRENT CIRCUIT BREAKERS. Introducing the DIN Series High-quality, high-performance circuit breakers

RM17UB3. Product data sheet Characteristics. voltage control relay RM17-U - range V AC. Main. Complementary

DeltaV Bulk Power Supplies

Datasheet - RSS 36-D-R-ST

Transcription:

DATASHEET - FAZ-C5/2-RT Miniature circuit breaker (MCB), 5A, 2p, C-Char, AC Part no. FAZ-C5/2-RT Catalog No. 102203 Eaton Catalog No. FAZ-C5/2-RT EL-Nummer 1691799 (Norway) Similar to illustration Delivery program Basic function Miniature circuit-breakers Number of poles 2 pole Tripping characteristic C Application Switchgear for industrial and advanced commercial applications Rated current I n A 5 Rated switching capacity acc. to IEC/EN 60947-2 I cu ka 15 Product range FAZ-RT Technical data Electrical Standards UL 489, CSA C22.2 No. 5 IEC 60947-2 Rated operational voltage U e V U e V AC 277/480 Y V DC 60 Rated voltage according to IEC/EN 60947-2 U n V AC 440 Rated voltage according to UL U n V AC 480Y/277 Rated switching capacity acc. to IEC/EN 60947-2 I cu ka 15 Breaking capacity according to UL ka 10 (UL489) Characteristic B, C, D Selectivity Class 3 lifespan Lifespan Operations > 20000 Direction of incoming supply as required Mechanical Standard front dimension mm 45 Enclosure height mm 105 Mounting width per pole mm 17.7 Mounting IEC/EN 60715 top-hat rail Degree of Protection IP20, IP40 (when fitted) Terminals top and bottom Twin-purpose terminals Terminal protection Finger and back-of-hand proof to BGV A2 Tightening torque of fixing screws N/m max. 2.4 UL: #18-12 AWG: 2.4 Nm (21 lb-in) #10-8 AWG: 2.8 Nm (25 lb-in) #6 AWG: 4 Nm (36 lb-in) Mounting position As required Design verification as per IEC/EN 61439 Technical data for design verification Rated operational current for specified heat dissipation I n A 5 Heat dissipation per pole, current-dependent P vid W 0 Equipment heat dissipation, current-dependent P vid W 3.7 08/17/2018 Eaton 102203 ED2018 V47.0 EN 1 / 5

Static heat dissipation, non-current-dependent P vs W 0 Heat dissipation capacity P diss W 0 Operating ambient temperature min. C -25 Operating ambient temperature max. C 75 linear, per +1 C, results in a 0.5% reduction of current carrying capacity IEC/EN 61439 design verification 10.2 Strength of materials and parts 10.2.2 Corrosion resistance Meets the product standard's requirements. 10.2.3.1 Verification of thermal stability of enclosures Meets the product standard's requirements. 10.2.3.2 Verification of resistance of insulating materials to normal heat Meets the product standard's requirements. 10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects Meets the product standard's requirements. 10.2.4 Resistance to ultra-violet (UV) radiation Meets the product standard's requirements. 10.2.5 Lifting Does not apply, since the entire switchgear needs to be evaluated. 10.2.6 Mechanical impact Does not apply, since the entire switchgear needs to be evaluated. 10.2.7 Inscriptions Meets the product standard's requirements. 10.3 Degree of protection of ASSEMBLIES Does not apply, since the entire switchgear needs to be evaluated. 10.4 Clearances and creepage distances Meets the product standard's requirements. 10.5 Protection against electric shock Does not apply, since the entire switchgear needs to be evaluated. 10.6 Incorporation of switching devices and components Does not apply, since the entire switchgear needs to be evaluated. 10.7 Internal electrical circuits and connections Is the panel builder's responsibility. 10.8 Connections for external conductors Is the panel builder's responsibility. 10.9 Insulation properties 10.9.2 Power-frequency electric strength Is the panel builder's responsibility. 10.9.3 Impulse withstand voltage Is the panel builder's responsibility. 10.9.4 Testing of enclosures made of insulating material Is the panel builder's responsibility. 10.10 Temperature rise The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices. 10.11 Short-circuit rating Is the panel builder's responsibility. The specifications for the switchgear must be observed. 10.12 Electromagnetic compatibility Is the panel builder's responsibility. The specifications for the switchgear must be observed. 10.13 Mechanical function The device meets the requirements, provided the information in the instruction leaflet (IL) is observed. Technical data ETIM 6.0 Circuit breakers and fuses (EG000020) / Miniature circuit breaker (MCB) (EC000042) Electric engineering, automation, process control engineering / Electrical installation, device / Miniature circuit breaker system (MCB) / Miniature circuit breaker (MCB) (ecl@ss8.1-27-14-19-01 [AAB905011]) Release characteristic C Number of poles (total) 2 Number of protected poles 2 Nominal rated current A 5 Nominal rated voltage V 415 Rated short-circuit breaking capacity Icn EN 60898 at 230 V ka 0 Rated short-circuit breaking capacity Icn EN 60898 at 400 V ka 0 Rated short-circuit breaking capacity Icu IEC 60947-2 at 230 V ka 15 Rated short-circuit breaking capacity Icu IEC 60947-2 at 400 V ka 15 Voltage type AC Current limiting class 3 Frequency Hz 50-60 Concurrently switching N-neutral No Suitable for flush-mounted installation No Over voltage category 3 Pollution degree 2 Width in number of modular spacings 2 Built-in depth mm 70.5 08/17/2018 Eaton 102203 ED2018 V47.0 EN 2 / 5

Additional equipment possible Yes Degree of protection (IP) IP20 Approvals Product Standards IEC/EN 60947-2; UL 489; CSA-C22.2 No. 5-09; CE marking UL File No. E235139 UL Category Control No. DIVQ CSA File No. 204453 CSA Class No. 1432-01 North America Certification UL listed, CSA certified Specially designed for North America Yes, suitable as BCPD Suitable for Feeder circuits, branch circuits Current Limiting Circuit-Breaker Yes Max. Voltage Rating 32 A Degree of Protection IEC: IP20, UL/CSA Type: - 08/17/2018 Eaton 102203 ED2018 V47.0 EN 3 / 5

Characteristics Let-through energy I 2 t Characteristic C (0.5-20 A), 277 V 08/17/2018 Eaton 102203 ED2018 V47.0 EN 4 / 5

Characteristic C (25-40 A), 240 V 08/17/2018 Eaton Industries GmbH http://www.eaton.eu 08/2018 by Eaton Industries GmbH Eaton 102203 ED2018 V47.0 EN 5 / 5