Modular telecontrol system for GPRS and network structures

Similar documents
Modular Two-Wire Telecontrol System

THE SOLUTION. MFW product family DATASHEET. MFW - Modular radio telecontrol system. A system from the. INFOwww.ees-online.de

THE SOLUTION. MFW product family OPERATING INSTRUCTIONS. I/O expansion modules. Modules from the

THE SOLUTION. MFW product family OPERATING INSTRUCTIONS. Modular optical fibre telecontrol system. Application-ready systems from the

Telecontrol and Automation Systems

Installation / control / monitoring technique. CANopen PLC IL 5504, IN 5504 minimaster

Installation / control / monitoring technique. CANopen PLC IL 5504, IN 5504 minimaster

Installation / Control / Monitoring Technique

TIM 3V- IE ADVANCED. Function

General information. Display. Supply voltage

General information. Display. Supply voltage. Input current. Encoder supply. Output current

FLEXIBLE SOLUTIONS FOR THE ENERGY INDUSTRY

Display. Supply voltage. Input current. Encoder supply. Output current. Power losses. Memory

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information. Display. Supply voltage. Input current

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information. Display. Supply voltage. Input current. Encoder supply. Power losses

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information. Display. Supply voltage. Input current

General information. Display. Supply voltage. Input current

General information Engineering with Programming package. Display with display. Supply voltage 24 V DC Yes. Input current

Sub-Station Station. Secondary Sub. Sub- Distribution. Network. Distribution Panel. Distribution. Panel

Display. Supply voltage. Input current. Encoder supply. Output current. Power losses. Memory

General information. Display. Supply voltage

General information. Display. Supply voltage. Input current

General information. Display. Supply voltage. Input current

General information Engineering with Programming package. Display with display. Supply voltage 24 V DC Yes

General information. Display. Supply voltage

General information. Supply voltage. Input current. Encoder supply. Power loss. Memory

General information. Display. Supply voltage. Input current

General information. Display. Supply voltage. Input current. Encoder supply. Output current

Virtual Mapping with Weidmuller s Router

General information. Display. Supply voltage. Input current

JUMO mtron T Measuring, Control, and Automation System

ISOMETER isoev425 with coupling device AGH420

Bilfinger Mauell GmbH. smartrtu ME 4012 PA-N

Z-GPRS2-SEAL THE SIMPLEST REMOTE MANAGEMENT SYSTEM FOR UNIVERSAL APPLICATIONS GSM/GPRS DATALOGGER WITH BUILT-IN I/O S AND TELECONTROL FUNCTIONS

MIC-2 MKII & MIC-2 MKII DIN, Multi-instrument DATA SHEET

CLIMATIX STEQ, STCM DATASHEET FOR CONTROLLING, SWITCHING AND MONITORING FUNCTIONS. POWER SUPPLY RELAY OUTPUTS. Power supply. 4.

Your process requires the utmost attention Our new ACT20C signal conditioners support you in achieving this

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information. Display. Supply voltage. Input current. Encoder supply. Output current. Power loss. Memory

General information Engineering with Programming package. Display with display

An all-in-one module. Archiving Up to 50,000 data items time-and-date stamped and saved to flash memory

SICAM A8000 Series. Operation, telecontrol, and automation in the smallest spaces. siemens.com/sicam-a8000

Accessories / 7XV5820

MIC-2 Multi-instrument DATA SHEET

General information Engineering with Programming package. Display with display. Supply voltage 24 V DC Yes. Input current

JUMO mtron T. Measuring, Control, and Automation System. Features. Brief description. Systembus LAN. Data Sheet Page 1/12. Com1.

ISOMETER isoev425/isoev425hc with coupling device AGH420

COMTRAXX COM465DP. Condition Monitor with integrated gateway for the connection of Bender devices to PROFIBUS DP and Ethernet TCP/IP networks

6ES7212-1BD30-0XB0. permissible range, lower limit (DC) permissible range, upper limit (DC)

MIC-2 MKII, Multi-instrument DATA SHEET

Data sheet CC 03, Commander Compact (603-1CC21)

ZBRN1 access point- 2 RJ V AC/DC-4 displays-5 LEDs-Eth-Modbus-wireless radio

Standard protocol support (e.g. MODBUS, SNMP, M-Bus), possibility to install dedicated user protocols

RTU32S RTU32S Series Small Compact Utility RTU

RTU modules Create your infrastructures with peace of mind!

DGSZV-EP DIGITAL GALVANIC LONGITUDINAL DIFFERENTIAL PROTECTION. Application field

CPU 1214C. Overview. Design. The compact CPU 1214C has:

CPU module for zone 2 Series 9442/35

Networks TN, TT, IT networks 3 and 4-phase networks Up to 4 single-phase networks

Web-enabled DAQ System

ZBRN1 access point- 2 RJ V AC/DC-4 displays-5 LEDs-Eth-Modbus-wireless radio

Data sheet CPU 115 (115-6BL02)

PRELIMINARY. USB1 / USB2 USB host interface to read data via memory stick. Bus Out (system bus) For connection to a router

XPSMF35. Product data sheet Characteristics. Preventa safety PLC compact - Profibus DP protocol. Main. Complementary. Safety module name

RTU32S RTU32S Series Small Compact Utility RTU

XPSMF40. Main. Safety module name. Monitoring safety detection discrete input Monitoring safety dialogue discrete output

I/A Series Remote Terminal Unit (RTU) RTU 20 for Oil, Gas, and Water SCADA Applications

ZBRN1. Main. Device short name

Data sheet VIPA CPU 115DP (115-6BL22)

WAGO Energy Data Management Efficiency Is That Easy!

MPI-DN, MPI-D MULTICHANNEL ELECTRONIC RECORDER for HART or RS-485/ MODBUS RTU SENSORS

SINGLE PHASE AMR ELECTRONIC METER MEM Electric meter has the following functions: Technical information

COMTRAXX COM460IP. BMS-Ethernet-Gateway

KAUGJUHTIMISSÜSTEEMID TELECONTROL SYSTEMS MODEM TELEM-GSM/GPRS 3G. User manual

COMTRAXX COM465IP. Condition Monitor with integrated gateway for the connection of Bender devices to Ethernet TCP/IP networks

THREE PHASE ROUTER ELECTRONIC METER MET410...K Electric meter has the following functions: Technical information

BMS-Ethernet-Gateway COM460IP

Dupline. Data Logger. Types G , G Product Description. Ordering Key G Type Selection. Input/Output Specifications

Datasheet TeleController TC302

Advant OCS. The Compact and Cost Effective Advant Controller. Advant Controller 210. Open Control System

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

Data Sheet T 6493 EN. TROVIS 6400 Automation System TROVIS 6493 Compact Controller. For panel mounting (front frame 48 x 96 mm/1.89 x 3.

Neon pr. ph/ ORP measurement. Applications. Description

Logic Controller Millenium Evo

Multifunction controller GHM-ONE MSR9696H. Multifunction controller. Features. ... professional Instruments M ADE IN GERMANY

ROCON RPC 116. SUBSTATION AUTOMATION Central unit for substation automation

Faults on the system Proximity switch connection technology:

The Next Level of Energy Data Management Fast Data Acquisition via Parameterization No Programming

UCM 94/1 3G/GPRS Modem for RTU32 Series

EXOcompact. Freely programmable controller

PLC PFC200 Controller PFC200 CS 2ETH RS

CONFIGURABLE SAFETY RELAYS

Industrial Safety Systems

TM241CE24T controller M IO transistor PNP Ethernet

IMS AMS 111 II. Automatic Weather Station. Easy and reliable weather monitoring anywhere

Transcription:

Modular telecontrol system for GPRS and network structures *) Telecontrolling over public or private networks 12.06.2011 Use of Ethernet/IP-structures: LAN (CAT-cables, fibre), WLAN, WAN (DSL, GPRS) Integrated modems, symmetrical transmission behaviour GPRS substations can economically be operated either by dynamic or fixed IP adresses or also in a VPN Optimized data packets and integrated transmission volume counter No IT-Server needed Extremely low energy consumption of GPRS substations in low power technology Data logger function with preprocessing of the measurements (e.g. average, minimal -and maximum values as well as counter differences) Coupling possibilities to process control and visualization systems over standardised protocols (IEC 60870-5-101/104, Modbus RTU /-TCP) Remote parameter setting and remote diagnosis over dial-up line and respectively LAN or WAN connection Datasheet *) EES was honoured for this MFW-product by the Innovation Award 2007 from the Initiative of medium-sized companies MFW-NW-DB-UK-005

MFW-NW General system description of the MFW telecontrol family In the last couple of years IP based network techniques have established themselves also in the industrial area. There is often a request to use the existing network infrastructure also for transmission of plant conditions, measurements and counter values. For this formulation the approved MFW system was extended with the new network variant. With this variant also private and public networks can be used, in which the transmission media with the usual network technique (router, modems, media converter etc.) can be changed arbitrary and therefore lexibly adapted to heterogeneous networks. The following transmission medias are useable: LAN (CAT-cable, ibre) Wireless LAN DSL GPRS Structure of a MFW-System for networks The network stations of the MFW can be operated in one of the two following variants: Stand-alone ( decentralised peripheral station of a superior system ) or System integrated ( bind in a master substations- structure of a MFW system ) a) Use of a MFW-station as a stand-alone substation of a superior system CAT - cable Ethernet RTU GPRS RTU SCADA Visualisation Router with Firewall Router with Firewall Ethernet RTU If the MFW-station is being operated as a stand-alone substation of a superior system, the data transmission to the SCADA system or PC is done by IEC 60870-5-104 directly over the communication media. The data exchange is done over the communication media directly between superior system and the MFW substation without use of a MFW master unit. The administration of the connection links including the failure diagnosis and treatment must be taken over by the superior system The connection of arbitrary noumerous RTUs to a host is possible Page 2 of 12

MODULAR NETWORK TELECONTROL SYSTEM a) Integration of MFW substations in a MFW system structure Option 1: RS 232 with IEC 60870-5-101 or Modbus-RTU CAT - cable Ethernet RTU GPRS RTU SCADA Visualisation Option 2: Ethernet with IEC 60870-5-104 or Modbus-TCP Router with Firewall Router with Firewall Ethernet RTU By this operation mode the communication on the transmission media occurs between master and substations within the MFW-system. The substations do not have a direct contact to the superior system, but communicate only with the MFW-master. The handover of values within the master ( e.g. from the MFW-master to a SCADA system ) is relalised by a serial interface, an Ethernet interface, or by I/O modules attached to the master. In this operation mode the following elementary features are given: The MFW master does the administration of the communication links ( e.g. address management und supervision of the transmission links ) For the communication between master and superior system the protocol interfaces IEC 60870-5-101 / -104, Modbus-RTU or Modbus-TCP are useable. By use of the serial interface the master ensures a disjunction between substations and SCADA system The communication between master and substations is done by a volume optimised proprietary protocol. The used data volume is an important characteristic for GPRS transmission. At a master module with Ethernet interface (see drawing ) a maximum of 31 substations can be connected. Master stations with GPRS-modem ( direct GPRS GPRS connection ) can administrate 8 GPRS substations. If more substations are needed additional master stations can be used. In the drawing above the transmission principle between the MFW-master module with network connection over Ethernet is shown. Master modules with internal GPRS modem do not need a router and no DSL modem for the communication of up to 8 GPRS substations. Page 3 of 12

MFW-NW Data transmission in heterogenious networks In the following example on the next page different useable transmission medias are shown. LAN (Ethernet) In the simplest case the master and a substation are connected over a Crosslink cable. The MFW basic modules can just, however, be connected with a switch or router and therefore integrated into the available network over CAT cables. A irm IP-address is assigned to all MFW stations in the local network. The master module manages the address data of the substations in the integrated Link Allocator. LAN (optical fibre) The Ethernet connection can be converted under use of customary media converters on an optical ibre connection in rough disturbing contaminated surroundings, e.g. transformer stations, or to bridge larger distances. Wireless LAN By means of a router with wireless functionability wireless transmission lines can also be included. WAN (DSL) The transition of the local network to the Internet is carried out via a DSL modem attached at the router. Therefore a ixed IP of the DSL access, available from outside is needed. The router converts the accessable IP-address from outside to the internal local IP-address with the help of port numbers. To protect the local network the router should be equipped with a irewall like in all Internet transitions. WAN (GPRS) GPRS is the packet oriented transmission service of the GSM mobile radio. The combination between DSL, Internet and GPRS is realized by the respective providers. IP-addresses are generally allocated dynamically in the GPRS net. The construction of a VPN (Virtual private Network) initiated by the GPRS provider or the use of ixed IP-addresses is also possible with a MFW substation. The MFW system is conceived for the symmetrical communication. This means that the GPRS substations not only cyclical or event-driven establish connection to the master, itself is also able to set-up an active connection, e.g. for carrying out orders or set values. If the symmetrical connection is used, we recommend to use a master with callback function. These have an additional modem and ensure the reliable and cost-saving rebuilding of the connection by a special method after short-time disturbances of the GPRS net or the loss of the IP-address of the substation. Since the master also manages the IP-addresses of the GPRS substations, the additional IT server required in different systems is obsolete. The visibility of IP addresses in heterogenious networks is an important criteria for the choice of SIM-cards. Detailed information can be taken from our operation manual. Despite these advantages the GPRS data transmission isn t more economical as a modem connection in every case. The application possibilities and the cost performance ratio are determined by many factors, such as data volume, package sizes, rate structure and not last the GPRS coverage of the respective network provider. On alternative we are able to offer you the MFW-dial-up system for analog land lines or GSM nets. Furthermore information can be found in the separate datasheet MFW dial-up telecontrol system. Page 4 of 12

MODULAR NETWORK TELECONTROL SYSTEM Principle diagram Page 5 of 12

MFW-NW Archive function MFW network stations can provide additionally to the process image 2 optional data memories, whose values also can be transmitted over the telecontrol links: Measured values archive Event archive time cycled storage of the preprocessed message, counter- and measured values with time stamp event triggered storage of messages, counter or measured values with time stamp Soft-PLC Optionally basic modules can provide an integrated PLC functionality. The Soft-PLC of the MFW is programmed acc. to the international standard IEC 61131-3. By implementing the popular CoDeSys run time system (Controller Development System) extensive libraries for measuring and controlling processes are availabe for the user. The realised concept enables the Soft-PLC the access to in- and outputs, archives, diagnosis information and system functions of the MFW. The PLC-Programm can be done in one or more selectable of the IEC 61131-3-standard designated languages: Instruction list Structured text Sequential function chart Function block diagram Continous function chart Ladder diagram As amendment to the IEC language standard deined modules and extensive libraries the MFW provides additional functions for solutions of typical telecontrol requirements, e.g media dependent diagnosis (e.g. ield reception strength) or the dispatch and reception of SMS in modules with GSM/GRPS-modem. Furthermore information about the PLC functionality of the MFW can be taken from the separate MFW functional description of the Programmable logic controller. Energy saving function in GPRS substations The GPRS substations in low power design have an energy management in common to reduce the energy demand at parameterisable times by switching the operation mode between communication and energy-saving. This function enables through the extremely reduced power consumption the supply over solar power or battery packs with maintenance intervals of several years. Elaborate information about these functions can be found in the functional description in the data logging devices. Page 6 of 12

MODULAR NETWORK TELECONTROL SYSTEM Terminal assignments Substation with serial interface Substation with 8 DI Antenna jack only with GPRS RTU Antenna jack only with GPRS RTU Substation low-power Master and stand-alone Ethernet substation Antenna jack only with GPRS RTU On option the two Namur inputs of the low power substation can be replaced by 2 digital inputs. Substation with 5 DI, 2 AE and 1 DA Antenna jack only with GPRS RTU The common GND of the inputs C is equipotential with L- of the supply voltage. MFW-I/O unit MFW modem unit (Only with GPRS substations) MFW-CPU unit DO1 is a plus switching PNP transistor DCF77 antenna Fault message relay Page 7 of 12

MFW-NW Dimensional drawings Basic module with Ethernet-interface and optional protocol interface Basic module with Ethernet-interface and 8 DI Ethernet CAN-Bus SDP-interface approx. 58 Basic module with GSM/GPRS-modem and protocol interface Please take into account to provide enough space for the aerials. Aerial set A: - overall depth 165 mm Aerial set B: - overall depth 180 mm Basic module with GSM/GPRS-modem and protocol interface Page 8 of 12

MODULAR NETWORK TELECONTROL SYSTEM System requirements Master module with Ethernet-connection Network router 10/100 Mbit Change-over to ibre Ethernet / Fibre converter Change-over to WLAN Change-over to DSL WLAN Access Point DSL-connection with ixed IP and DSL modem Ethernet substation Network 10/100 Mbit GPRS substation Master module with GPRS-modem GPRS substation GPRS-capable SIM-card* GPRS-capable SIM-card with ixed IP-adress* GPRS-capable SIM-card with ixed IP-adress* * available GPRS-net and suficient GSM-ield reception Technical data General data Mounting Housing / protection class Air humidity Connection terminals Conductor cross-section rigid or lexible Without wire-end sleeves With wire-end sleeves Operation and ambient temperature Master module with analog callback modem Operating voltage Nominal operating voltage UB Operating voltage range Basic module with expansion modules Master module Power consumption Ethernet-connection with landline call-back Modem galvanic isolation between dial-up and supply voltage Ethernet substation ( standard variant ) Power consumption Ethernet connection Range with twisted-pair cable GPRS-substation (standard variant ) Power consumption DIN-rail acc. to 60715:2001-09 Plastic / IP 40 Maximum 95 %, non-condensing pluggable 0,2... 2,5 mm2 0,25... 2,5 mm2-20 C... +60 C except 0 C... +60 C 24V DC 10... 32 V DC 20... 32 V DC approx. 2,5 W 10 Base-T 0,5 kveff approx. 2,5 W 10-Base T 100m approx. 2,5 W Page 9 of 12

MFW-NW Technical data Relay contacts Load on relay contacts*1 minimum maximum Total current Digital inputs at modules in standard variant Input voltage US Rated voltage Maximum voltage Voltage for high-state (DC) Voltage for high-state (AC) Voltage for low-state (DC) Voltage for low-state (AC) Input resistance Max. count rate Min. pulse width / pause Galvanic isolation between signal and supply voltage GPRS-substations in low power variant Power consumption in communication mode (basic module only) Current consumption in energy-saving mode Operating voltage limits *3 Range 1 > 9,6 V Range 2 < 9,6 V Range 3 < 4,5 V Range 4 < 2,5 V Potential separation Ramp-up time Tracking time Buffer time of the internal battery pack Charging time of the internal battery pack Digital inputs at low power modules Input voltage Rated voltage Maximum voltage Minimum voltage for high-state Maximum voltage for low-state Input resistance E1... E4 E5... E6 Max. count rate Min. pulse width / pause Page 10 of 12 1,2 V / 1 ma (suitable for control of LED) 250 V AC / 400 ma 250 V AC / 2 A (pure ohmic load) 30 V DC / 2 A 110 V DC / 0,2 A 220 V DC / 0,1 A max. 8 A (pure ohmic load) 24 V AC/DC 48 V > 15 V bzw. < -15 V > 19 Veff < 9 V bzw. > -9 V < 6 Veff 10 KΩ 10 Hz 50 ms 4 kveff approx. 2,5 W < 2 ma normal operation mode no communication mode longer available, however still archiving (Return to normal operation mode, when operating voltage > 10,8 V ) no archiving, real-time clock runs, no data loss Loss of archives, break-down of real time clock Equipotential between inputs and supply voltage parameterisable 0... 255 s parameterisable 0... 65.535 s at least 12 h maximum 72 h 24 V DC 48 V 7,0 V 2,2 V approx. 100 kω approx. 33 kω 10 Hz 50 ms

MODULAR NETWORK TELECONTROL SYSTEM Technical data Namur inputs According to the standards Switching threshold Low High No-load voltage Internal resistance Error status (Error bit set) EN50227 (DIN 19234) or IEC60947-5-6 Max. count rate Min. pulse width / pause < 1,2 ma > 2,1 ma 8,2 V DC 1 kω Current < 0.3 ma open circuit > 6 ma short circuit 25 Hz 20 ms Analog inputs Measuring range Resolution Deviation Input restistance 0... 10 V 10 Bit < 0.5% from end value of measuring range 70 kω Wake-up input Input voltage Rated voltage Maximum voltage Minimum voltage for high-state Maximum voltage for low-state Input resistance approx. Minimum pulse width 24 V DC 48 V DC 7.0 V DC 2.2 V DC 100 kω 1s *1 We would be happy to supply you with more precise speciications on request. *2 We recommend not to run pulse inputs with alternating voltage, but only with direct voltage. *3 The internal battery buffers range 3 If not otherwise noted, the given information for alternating voltage are refering to a sinusoidal alternating voltage with a frequency of 50/60 Hz. For speciication of the expansion modules see separate data sheet. The right to make technical changes is reserved Order identification of systemintegrated stations Master module for data over Ethernet connection 97BXNGCPABX0 MF-XNGPR-G8DAR-AKP-A-BX-0 97GXNGCPABX0 MP-XNGPR-G8DAR-AKP-A-BX-0 97EXN1HPABX0 97EAN1HPABX0 97EIN1HPABX0 97EGN1HPABX0 MD-XNGPR-1P10X-AKP-A-BX-0 MD-ANGPR-1P10X-AKP-A-BX-0 MD-INGPR-1P10X-AKP-A-BX-0 MD-GNGPR-1P10X-AKP-A-BX-0 Callback-Modem / Process coupling / Options without / AKP-Protocol + 8 Relay outputs without / AKP-Protocol + 8 Relay outputs / Archiving + PLC without / IEC 60870-5-101/104 / Archiving Analog / IEC 60870-5-101/104 / Archiving ISDN / IEC 60870-5-101/104 / Archiving GSM / IEC 60870-5-101/104 Archiving Page 11 of 12

MFW-NW Master module for data exchange over GPRS-Modem 97EGG1HPABX0 MD-GGGPR-1P10X-AKP-A-BX-0 97EGG1JPABX0 MD-GGGPR-1PMIP-AKP-A-BX-0 97GGG1HPABX0 MP-GGGPR-1P10X-AKP-A-BX-0 Process coupling / Options IEC 60870-5-101/104 / Archiving Modbus-RTU/TCP / Archiving IEC 60870-5-101/104 / Archiving + PLC Substation module for data exchange over Ethernet-connection Process coupling / Options 97HXNGANABB0 UF-XNGPR-G8DIX-DIA-A-BB-0 8 DI, 24 V 97KXNGANABB0 UD-XNGPR-G8DIX-DIA-A-BB-0 8 DI, 24 V / Archiving 97MXNGANABB0 UP-XNGPR-G8DIX-DIA-A-BB-0 8 DI, 24 V / Archiving + PLC 97KXN1JNABX0 UD-XNGPR-1PMIP-DIA-A-BX-0 Modbus-RTU/TCP / Archiving Substation module for data exchange over GPRS-Modem 97KGGGANABB0 UD-GGGPR-G8DIX-DIA-A-BB-0 97MGGGANABB0 UP-GGGPR-G8DIX-DIA-A-BB-0 97KGGGPNABB0 UD-GGGPR-G6D2A-DIA-A-BB-0 97MGGGPNABB0 UP-GGGPR-G6D2A-DIA-A-BB-0 97KGG1BNABX0 UD-GGGPR-1P512-DIA-A-BX-0 97KGG1JNABX0 UD-GGGPR-1PMIP-DIA-A-BX-0 Low-Power-Substation module mit GPRS-Modem 97LGGGLNABB0 UL-GGGPR-G2N6D-DIA-A-BB-0 Process coupling / Options 8 DI, 24 V / Archiving 8 DI, 24 V / Archiving + PLC 5 DI, 24 V; 1 DA, 24 V; 2 AE (0 20 ma) / Archiving 5 DI, 24 V; 1 DA, 24 V; 2 AE (0 20 ma) / Archiving + PLC 3964R/RK512 / Archiving Modbus-RTU/TCP / Archiving Process coupling / Options 6 DI (2 useable as AI), 2 Namur / Archiving + energy saving function Order identification of stand-alone stations Data exchange over Ethernet or RS232 97EXN1XHABX0 MD-XNGPR-1P10X-AKP-A-BX-0 Protocol / Process coupling / Options IEC 60870-5-101/104 / over I/O-Module / Archiving Data exchange over internal GPRS-Modem 97KGHGANABB0 UD-GG104-G8DIX-DIA-A-BB-0 Protocol / Process coupling / Options IEC 60870-5-104 and 8 DI, 24 V / Archiving Expansion modules More informationen can be taken from the seperate datasheet. Accessories Expansion modules, power supplies, buffer chargers, solar power supplies, batteries and battery packs, antennas, parameterising cable. Kontakt Contact Elektra Elektronik GmbH & Co Störcontroller KG Hummelbühl 7-9 71522 Backnang/Germany Tel.: +49 (0) 7191/182-0 Fax: +49 (0) 7191/182-200 E-Mail: info@ees-online.de Internet: www.ees-online.de Powered by TCPDF (www.tcpdf.org)