Configuring Synchronous Ethernet ESMC and SSM

Similar documents
Synchronous Ethernet (SyncE) ESMC and SSM

Network Synchronization Support

Configuring Network Clock for Cisco ASR 901S Router

Configuring Clocking. Configuring Clocking. Restrictions

G Telecom Profile

Configuring Frequency Synchronization

Timing and Synchronization Configuration Guide, Cisco IOS XE Everest (Cisco ASR 920 Routers)

PASS4TEST. IT Certification Guaranteed, The Easy Way! We offer free update service for one year

Configuring Clocking and Timing

KillTest. Mejor calidad Mejor servicio. Renovación gratuita dentro de un año

Introduction. Node Timing Parameters. Revised: June 5, 2017, OL This document provides information about Cisco NCS users and node timing.

Overview of the Ethernet SPAs

Single-router APS for the Cisco Series Router

Timing. 6.1 Timing Parameters CHAPTER

MPLS Transport Profile

Enhancing Synchronous Ethernet Management with ESMC

ITU-T G.8264/Y.1364 (08/2017) Distribution of timing information through packet networks

Understanding PTP. A network device physically attached to the primary time source. All clocks are synchronized to the grandmaster clock.

Circuit Emulation over IP

Area Command in Interface Mode for OSPFv2

PTP Primer for the Cable Dummies

POS on ONS Ethernet Cards

1-Port OC-48/STM-16 Packet over SONET Line Card Configuration

Configuring MPLS Transport Profile

POS on ONS Ethernet Cards

Using Ethernet Operations Administration and Maintenance

This document provides information about Cisco NCS users and node timing. The document contains the topics mentioned below.

Configuring VRRP. Finding Feature Information. The Virtual Router Redundancy Protocol (VRRP) is an election protocol that dynamically assigns

7600 Router Clock Distribution

Using Ethernet Operations Administration and Maintenance

Configuring TCP Header Compression

Configuring TCP Header Compression

FPG Endpoint Agnostic Port Allocation

Clock Recovery System

Troubleshooting Physical Layer Alarms on SONET and SDH Links

G Telecom Profile

BITS Port Configuration Mode Commands

G Telecom Profile

Synchronous Ethernet. Silvana Rodrigues, IDT Presentation to WSTS-11, May 10-12, 2010, Westminster, Colorado

Configuring POS interfaces

Configuring Pseudowire

Tutorial: Network-based Frequency, Time & Phase Distribution

Power over Ethernet Commands

VRRPv3 Protocol Support

Configuring IP SLAs TCP Connect Operations

Transparent SONET or SDH over Packet (TSoP) Protocol

Transparent SONET or SDH over Packet (TSoP) Protocol

Access Circuit Redundancy Support for IMA

Flow-Based per Port-Channel Load Balancing

Clock Recovery System

Configuring IP SLAs Metro-Ethernet 3.0 (ITU-T Y.1731) Operations

UniDirectional Link Detection (UDLD) Protocol

Clock Recovery System

PPP over Frame Relay

Traditional Synchronization Standards Overview

Using Flexible NetFlow Flow Sampling

Configuring DHCP. Finding Feature Information. Information About DHCP. DHCP Server. DHCP Relay Agent

Using Flexible NetFlow Flow Sampling

QoS Tunnel Marking for GRE Tunnels

Configuring RTP Header Compression

OSPF Limit on Number of Redistributed Routes

Configuring DHCP. Finding Feature Information. Information About DHCP. DHCP Server. DHCP Relay Agent

Configuring Clear Channel SONET Controllers on the Cisco ASR 9000 Series Router

CE Ethernet Operation

ITU-T G.8032 Ethernet Ring Protection Switching

Configuring DHCP. Finding Feature Information. Information About DHCP. DHCP Server. DHCP Relay Agent

IEEE Resilient Packet Ring Feature Guide

Configuring Data Export for Flexible NetFlow with Flow Exporters

Configuring RTP Header Compression

Configuring System MTU

Configuring IP SLAs Metro-Ethernet 3.0 (ITU-T Y.1731) Operations

Configuring the Cisco 3825 Mobile Wireless Edge Router in a RAN-O Solution with the Command-Line Interface

Configuring DHCP Option 60 and Option 82 with VPN-ID Support for Transparent Automatic Logon

Classifying and Marking MPLS EXP

Configuring ITU-T Y.1731 Fault Management Functions in IEEE CFM

Nested Class Map Support for Zone-Based Policy Firewall

MPLS LDP Graceful Restart

802.1P CoS Bit Set for PPP and PPPoE Control Frames

Overview of Circuit Emulation

Configuring IP SLAs TCP Connect Operations

Port-Level Shaping and Minimum Bandwidth Guarantee

Overview of Circuit Emulation

Configurable Queue Depth

BCP Support on MLPPP

RSVP Interface-Based Receiver Proxy

RMON Full. Finding Feature Information. Prerequisites for RMON Full

OSPFv2 Cryptographic Authentication

Configuring DHCP. Finding Feature Information. Information About DHCP. DHCP Server. DHCP Relay Agent

You must add the same user name and password to each node the user accesses.

Synchronization for Next Generation Networks The PTP Telecom Profile

Configuring SDH on 1-Port OC192/STM-64 or 8-Port OC3/12/48/STM-1/-4/-16 Module

Match-in-VRF Support for NAT

Using NetFlow Filtering or Sampling to Select the Network Traffic to Track

X.25 Record Boundary Preservation for Data Communications Networks

Multicast Subsecond Convergence

IEEE 802.1ah on Provider Backbone Bridges

Constraining IP Multicast in a Switched Ethernet Network

IPv6 Routing: RIP for IPv6

MPLS Point-to-Multipoint Traffic Engineering Support for Static Pseudowires

Configuring Auto IP SLAs in IP SLAs Engine 3.0

Transcription:

CHAPTER 17 Configuring Synchronous Ethernet ESMC and SSM With Ethernet equipment gradually replacing Synchronous Optical Networking (SONET) and Synchronous Digital Hierarchy (SDH) equipment in service-provider networks, frequency synchronization is required to provide high-quality clock synchronization over Ethernet ports. Synchronous Ethernet (SyncE) provides the required synchronization at the physical level. In SyncE, Ethernet links are synchronized by timing their bit clocks from high-quality, stratum-1-traceable clock signals in the same manner as SONET/SDH. Operation messages maintain SyncE links, and ensure a node always derives timing from the most reliable source. The SyncE synchronizes clock frequency over an Ethernet port. In SONET/SDH the communication channel for conveying clock information is Synchronization Status Message (SSM), and in SyncE it is the Ethernet Synchronization Message Channel (ESMC). Note For information about how to configure synchronous Ethernet, see Configuring Clocking and Timing. Contents Prerequisites for Synchronous Ethernet (SyncE): ESMC and SSM, page 17-1 Restrictions for Synchronous Ethernet (SyncE): ESMC and SSM, page 17-2 Information About Synchronous Ethernet (SyncE): ESMC and SSM, page 17-2 How to Configure Synchronous Ethernet (SyncE): ESMC and SSM, page 17-3 Configuration Examples for Synchronous Ethernet (SyncE): ESMC and SSM, page 17-6 Additional References, page 17-9 Prerequisites for Synchronous Ethernet (SyncE): ESMC and SSM You need to first configure the network clock for SyncE configuration. Automatic synchronization of the network clock should be enabled. Ensure the network-clock-select and network-clock-participate commands do not exist in the configuration in order to continue with the SyncE configuration. 17-1

Restrictions for Synchronous Ethernet (SyncE): ESMC and SSM Chapter 17 Restrictions for Synchronous Ethernet (SyncE): ESMC and SSM To use the network-clock synchronization ssm option command, the following conditions are required: No input source is in the configuration. No network clock quality level is in the configuration. No network clock source quality source is set under any synchronous Ethernet interface. The network-clock synchronization ssm option command must be compatible with the network-clock eec command in the configuration. The esmc process and synchronous mode commands can be used only if the SyncE capable interface is installed on the router. Information About Synchronous Ethernet (SyncE): ESMC and SSM Synchronous Ethernet (SyncE): ESMC and SSM, page 17-2 Synchronous Ethernet (SyncE): ESMC and SSM Customers using a packet network find it difficult to provide timing to multiple remote network elements (NEs) through an external time division multiplexed (TDM) circuit. The SyncE feature helps to overcome this problem by providing effective timing to the remote NEs through a packet network. SyncE leverages the physical layer of Ethernet to transmit frequency to the remote sites. SyncE s functionality and accuracy resemble the SONET/SDH network because of its physical layer characteristic. SyncE uses ESMC to allow the best clock source traceability, to correctly define the timing source, and to help prevent a timing loop. SONET/SDH use 4 bits from the two S bytes in the SONET/SDH overhead frame for message transmission. Ethernet relies on ESMC that is based on an IEEE 802.3 organization-specific slow protocol for message transmission. Each NE along the synchronization path supports SyncE, and SyncE effectively delivers frequency in the path. SyncE do not support relative time (for example, phase alignment) or absolute time (Time of Day). SyncE provides the Ethernet physical layer network (ETY) level frequency distribution of known common precision frequency references. Clocks for use in SyncE are compatible with the clocks used in the SONET/SDH synchronization network. To achieve network synchronization, synchronization information is transmitted through the network via synchronous network connections with performance of egress clock. In SONET/SDH the communication channel for conveying clock information is Synchronization Status Message (SSM), and in SyncE it the Ethernet Synchronization Message Channel (ESMC). ESMC carries a Quality Level (QL) identifier that identifies the timing quality of the synchronization trail. QL values in QL-TLV are the same as QL values defined for SONET and SDH SSM. Information provided by SSM QLs during the network transmission helps a node derive timing from the most reliable source and prevents timing loops. ESMC is used with the synchronization selection algorithms. Because Ethernet networks are not required to be synchronous on all links or in all locations, the ESMC channel provides this service. ESMC is composed of the standard Ethernet header for an organization-specific 17-2

Chapter 17 How to Configure Synchronous Ethernet (SyncE): ESMC and SSM slow protocol; the ITU-T OUI, a specific ITU-T subtype; an ESMC-specific header; a flag field; and a type, length, value (TLV) structure. The use of flags and TLVs improves the management of SyncE links and the associated timing change. How to Configure Synchronous Ethernet (SyncE): ESMC and SSM Perform this task to configure SyncE using ESMC and SSM. Step 1 Step 2 Command or Action enable Router> enable configure terminal Purpose Enables privileged EXEC mode. Enter your password if prompted. Enters global configuration mode. Step 3 Router# configure terminal controller BITS Enters BITS controller configuration mode. Router(config)# controller BITS Step 4 applique {E1 T1} Specifies the BITS controller type. Step 5 Router(config-controller)# applique e1 E1 controller framing {crc4 no-crc4 none} T1 controller framing {esf none sf} E1 Controller Router(config-controller)# framing crc4 Specify the framing type for the E1 or T1 BITS interface. For an E1 interface, ensure that the controller is set to use crc4 framing; CRC4 is the default setting. For a T1 interface, configure the controller to use ESF framing; ESF is not the default setting. Step 6 T1 Controller Router(config-controller)# framing esf ssm Enables SSM on the T1 or E1 BITS interface. Step 7 Router(config-controller)# ssm sabit Router(config-controller)# sabit 4 (Optional) Specifies the San synchronization status bit used to indicate the clock quality level. Valid values are 4 8. Note This command only applies to the E1 controller. 17-3

How to Configure Synchronous Ethernet (SyncE): ESMC and SSM Chapter 17 Step 8 Command or Action exit Purpose Exits controller configuration mode and returns to configuration mode. Step 9 Router(config-controller)# exit Router(config)# network-clock synchronization automatic Router(config)# network-clock synchronization automatic Step 10 network-clock eec {1 2} Step 11 Step 12 Router(config)# network-clock eec 1 network-clock synchronization ssm option {1 2 {GEN1 GEN2}} Router(config)# network-clock synchronization ssm option 2 GEN2 network-clock input-source priority {controller BITS E1} {interface type slot/card/port] {external [2m 10m]}} Enables the network clock selection algorithm. This command disables the Cisco-specific network clock process and turns on the G.781-based automatic clock selection process. Configures the clocking system hardware with the desired parameters. These are the options: For option 1, the default value is EEC-Option 1 (2048). For option 2, the default value is EEC-Option 2 (1544). Configures the router to work in a synchronization network. Option 1 refers to synchronization networks designed for Europe. This is the default value. Option 2 refers to synchronization networks designed for United States. Enables you to select an interface as an input clock for the router. You can select the BITS, Gigabit Ethernet 0/0, Gigabit Ethernet 0/1 interfaces, or GPS interfaces. Step 13 Step 14 Router(config)# network-clock input-source 1 interface GigabitEthernet 0/1 network-clock synchronization mode ql-enabled Router(config)# network-clock synchronization mode ql-enabled network-clock hold-off {0 milliseconds} Configure the automatic selection process ql-enabled mode. QL is disabled by default. ql-enabled mode can be used only when the synchronization interface is capable to send SSM. (Optional) Configures hold-off timer for the interface. Step 15 Step 16 Router(config)# network-clock hold-off 0 network-clock wait-to-restore seconds Router(config)# network-clock wait-to-restore 70 network-clock-select mode {revert nonrevert} Router(config)# network-clock-select mode revert (Optional) Configures wait-to-restore timer for the SyncE interface. (Optional) Specifies the router switching mode when recovering from a failure. 17-4

Chapter 17 How to Configure Synchronous Ethernet (SyncE): ESMC and SSM Command or Action Step 17 network-clock-select hold-timeout {timeout infinite} Purpose (Optional) Specifies how long the router waits before reevaluating the network clock entry. Step 18 Router(config)# network-clock-select hold-timeout 2000 esmc process Enables the ESMC process. Step 19 Router(config)# esmc process network-clock external slot/card/port hold-off {0 milliseconds} Overrides the hold-off timer value for the external interface. Step 20 Router(config)# network-clock external 0/1/0 hold-off 0 network-clock quality-level {tx rx} value {interface type slot/card/port external {2m 10m} controller {BITS E1} Forces the QL value for line or external timing input and output. Step 21 Router(config)# network-clock quality-level rx QL-STU GigabitEthernet 0/0 interface type number Enters interface configuration mode. Step 22 Step 23 Router(config)# interface GigabitEthernet 0/0 synchronous mode Router(config-if)# synchronous mode esmc mode [ql-disabled tx rx] value Configures the Ethernet interface to synchronous mode and automatically enables the ESMC and QL process on the interface. (Optional) Enables the ESMC process on the interface. Step 24 Router(config-if)# esmc mode rx QL-STU network-clock source quality-level value {tx rx} (Optional) Provides the forced QL value to the local clock selection process. Step 25 Router(config-if)# network-clock source quality-level ql-prc tx network-clock hold-off {0 milliseconds} (Optional) Configures the hold-off timer for the interface. Router(config-if)# network-clock hold-off 0 17-5

Configuration Examples for Synchronous Ethernet (SyncE): ESMC and SSM Chapter 17 Step 26 Step 27 Command or Action network-clock wait-to-restore seconds Router(config-if)# network-clock wait-to-restore 70 end Router(config-if)# end Purpose (Optional) Configures wait-to-restore timer for the SyncE interface. Exits interface configuration mode and returns to privileged EXEC mode. You can use the show network-clocks command to verify your configuration. Configuration Examples for Synchronous Ethernet (SyncE): ESMC and SSM Synchronous Ethernet (SyncE): ESMC and SSM The following examples show the SyncE configuration sequence (configuring an interface with two SyncE interfaces and two external interfaces): Interface GigabitEthernet0/0 synchronous mode network-clock wait-to-restore 720! Interface GigabitEthernet0/1 synchronous mode! controller BITS ssm! network-clock synchronization automatic network-clock input-source 1 controller BITS network-clock input-source 1 gigabitethernet 0/0 network-clock input-source 2 gigabitethernet 0/1 network-clock synchronization mode QL-enabled network-clock-select hold-timeout infinite network-clock-select mode nonrevert The following examples shows how to verify whether ESMC is enabled or not: Router# show esmc Interface: GigabitEthernet0/0 Administrative configurations: Mode: Synchronous ESMC TX: Enable ESMC RX : Enable QL RX configured : NA QL TX configured : NA Operational status: Port status: UP 17-6

Chapter 17 Configuration Examples for Synchronous Ethernet (SyncE): ESMC and SSM QL Receive: QL-SSU-B ESMC Information rate : 1 packet/second ESMC Expiry: 5 second The following examples shows how to view the network clock synchronization details: Router# show network-clock synchronization detail Automatic selection process : Enable Equipment Clock : 2048 (EEC-Option1) Clock Mode : QL-Enable ESMC : Disabled SSM Option : 1 T0 : Internal Hold-off (global) : 300 ms Wait-to-restore (global) : 300 sec Revertive : No Force Switch: FALSE Manual Switch: FALSE Number of synchronization sources: 1 Secondary src: Ethernet0/0 Slots disabled 0x0 Monitor source(s): Ethernet0/0 Selected QL: QL-SEC sm(netsync_ql_dis NETCLK_QL_ENABLE), running yes, state 1A Last transition recorded: (begin)-> 1A (ql_mode_enable)-> 1A (src_added)-> 1A Nominated Interfaces Interface SigType Mode/QL Prio QL_IN ESMC Tx ESMC Rx *Internal NA NA/Dis 251 QL-SEC NA NA Et0/0 NA Sync/En 2 QL-DNU - - Interface: --------------------------------------------- Local Interface: Internal Signal Type: NA Mode: NA(Ql-enabled) SSM Tx: Disable SSM Rx: Disable Priority: 251 QL Receive: QL-SEC QL Receive Configured: - QL Receive Overrided: - QL Transmit: - QL Transmit Configured: - Hold-off: 0 Wait-to-restore: 0 Lock Out: FALSE Signal Fail: FALSE Alarms: FALSE Slot Disabled: FALSE Local Interface: Et0/0 Signal Type: NA Mode: Synchronous(Ql-enabled) ESMC Tx: Enable ESMC Rx: Enable Priority: 2 QL Receive: QL-DNU QL Receive Configured: - QL Receive Overrided: - QL Transmit: - 17-7

Configuration Examples for Synchronous Ethernet (SyncE): ESMC and SSM Chapter 17 QL Transmit Configured: - Hold-off: 300 Wait-to-restore: 300 Lock Out: FALSE Signal Fail: FALSE Alarms: FALSE Slot Disabled: FALSE Dont Use: FALSE Configured Priority: 2 Force Switch: FALSE Manual Switch: FALSE Manual Switch In progress: FALSE Holdoff_cfg: FALSE Wtr_cfg: FALSE Reason for alarm flag: 0 Msw in progress: FALSE Intf_sig_nv: 0 Hold off Timer: Stopped Wait to restore Timer: Stopped Switchover Timer: Stopped ESMC Tx Timer: Stopped ESMC Rx Timer: Stopped Tsm Delay Timer: Stopped 17-8

Chapter 17 Additional References Additional References Related Documents Related Topic SyncE configuration commands Document Title Cisco IOS Interface and Hardware Component Command Reference Standards Standard ITU-T G.8262 ITU-T G.8264 ITU-T G.781 Title Timing characteristics of synchronous Ethernet equipment slave clock (EEC) Timing distribution through Packet Networks Synchronization layer functions MIBs MIB None MIBs Link To locate and download MIBs for selected platforms, Cisco software releases, and feature sets, use Cisco MIB Locator found at the following URL: http://www.cisco.com/go/mibs RFCs RFC None Title 17-9

Additional References Chapter 17 17-10