Amano Nexus Lite Controller INSTALLATION MANUAL

Similar documents
ImproX IXP20 Controller INSTALLATION MANUAL

Amano (itrt) Intelligent Twin Reader Terminal INSTALLATION MANUAL

ISC GB-XX ISC GB-XX ISC GB-XX ISC GB-XX

Digital I/O Module. Impro (DIO) Digital I/O Module INSTALLATION MANUAL

MULTI-DISCIPLINE READERS. ImproX Multi-discipline Readers INSTALLATION MANUAL SPECIFICATIONS MODEL NUMBER: MDR GB-XX MDK GB-XX

UniScan. Impro UniScan Controller INSTALLATION MANUAL

Cluster Controller. Impro (CCM) Cluster Controller Module INSTALLATION MANUAL

Nexus Lite (Web Interface)

CRC220 and CRC221 INSTALLATION GUIDE. REF No.: DOC0014 ISSUE: 09

Quick Start Installation Guide

C5S120 Installation and Connection Guide

6222 Two Door Module Technical Operations Manual

Contents Safety precautions Product components Optional accessories Names of each parts Product Dimension Cables and Connectors Power Connection

genesis TECHNICAL MANUAL Two-Door Controller GEN-045

CP150B Vandal & Weather Resistant Keypad Security Systems

SF200. Installation Guide & Quick Start Guide. 2 TFT AC Terminal Version: 1.0 Date: June 2014

REX F-0-9 Standalone or Access Controller

Installation Instructions

FL MC 2000T. Fiber optic converter for 10/100Base-Tx to single- or multi-mode fiberglass with SC-duplex and ST connections. Data sheet 3379_en_B

Wiring Guide. EP.NMiNi 2. Version 1.04 Last Updated:

FL MC 2000E (SM40) LC

Two Door Controller GEN-045

Access Control Technology Ltd. reserve the right to change the contents of this manual and the system it applies to without prior notice.

Suprex RS-485 SPX-7500 Wired Reader-Extender

Connecting a Cisco Input Module

SNAP, CLICK, DONE. Getting Started Guide

Installation Instructions (KF-2000)

GV-AS/EV Controller. User s Manual

CV-550SPK V2 Waterproof Keypad/Reader/Controller Installation Instructions

TruPortal Dual Door Interface Module Quick Reference

F7_F707_F708 Installation Instruction V1.0 F7_F707_F708. Access Control Terminal. Installation Instructions

Digital Keypad Introduction

Xpass S2. Installation Guide. Intelligent IP Access Control Reader EN XPS2 V1.11.

Quick Start Guide. SEB-710 I/O Expansion board. Introduction

Installing Sentor. Hardware Installation

ControlKeeper 4. General Information. Connecting Relay Loads. Installation Sheet. Getting Started. Power Supply Wiring. Mounting the Cabinet

QUICK START GUIDE. 2.4 Inch Finger Vein Terminal Time Attendance & Access Control

A TCP/IP network CAT 5 cable If the network is faster than 10baseT a switching hub will be needed Static IP address

Copy Machine Reader. Installation and Setup Guide

IEI emerge MicroNode Install and Setup Guide. Contents

QUICK START GUIDE. 2.4 Inch TFT Terminal Time Attendance & Access Control

Cardax Prox Plus Mifare Reader

ACCESS CONTROL SYSTEM

EP/2 Installation Instructions

INSOMNIAC CIA G-600 Gateway Installation Manual P/N CIA Revision 1.0 Date Code:

NS1 Connection Unit Guide

DIGITAL DISPLAY. for Industry Applications. Series WAY-SSI. Key-Features:

2-Way Wireless I/O Expander Installation Guide

S125 Multi-Purpose 125 KHz RFID Reader USER MANUAL. 9V/24V DC Operating Voltage, AC (optional) KHz RFID EM4100/2 Cards & Tags

ACTpro 1500 Single Door IP Controller

Access control panel U-Prox IC E (Elevator control)

F1000 User's Manual. (Version: V1.01)

MR51e Reader Interface

GV-EL124S Electric Strike

Fibre Modem - Single-mode

ACTpro Single Door IP Controller. Operating & Installation Instructions

1 IF-810 or IF-811 Terminal (Slave) 2 Intended Use. 3 Assembly and Installation _V IF-810/IF-811

Encoder Firmware V User s Manual. Outdoor PTZ Camera Hardware Manual KCM /05/09.

The Programmable 4-Way Relay Card is an optional peripheral unit that provides four individually programmable relay output circuits.

PR602LCD v1.0 Installer Manual Rev. A

Quick Start Installation Guide

Unitary Controller. Features. Description. Technical Specification Sheet Rev. 6, March, 2000

Installation guide for PR302 v2.0 Rev. E

Datenblatt / Specifications. ACR880 GPRS Portable Smart Card Terminal. idvation GmbH

INTRINSICALLY SAFE DUPLEXER PROTECTION. ELECTRONICS, INC Vulcan Road Apopka, Florida MOTOR INSTRUCTION MANUAL

*520886* IntelliTouch Pool & Spa Control System MobileTouch Wireless Controller. User s and Installation Guide. P/N Rev A

VertX. V100, V200 and V300. Installation Guide Barranca Parkway Irvine, CA USA. November Rev A.1

Installation Guide for PR311SE and PR311SE-BK v1.0 Access Controllers Rev. B

Installation & Operation Guide

Wireless Key fob, Key pad & Receiver Range

Industrial RFID Reader

Wiring Guide EP.NMINI. Version 1.02 Last Updated:

W3-H Waterproof Keypad/Reader/Controller

GV-AS Controller. Installation Guide

Zodiac FR100 TM INSTALLATION MANUAL

IPassan Installation guide

GC 055. GSM Remote Monitoring. Operating and installation instructions

SmartLock Pro INSTALLATION MANUAL

Suprex Fiber Optic. Reader-Extender SPX-7400 SPX Product Manual. Reader-Extender. Manual. SPX-7400 Series EXP Suprex_FiberOptic_MAN_170502

SmartLock Controller INSTALLATION MANUAL

Model MUGAPLM Multi-Unit Gate Access Panel. MUGAPLM Installation & Assembly

ACR880 GPRS Portable Smart Card Terminal

Installation Guide. Avigilon ACM Embedded Controller

SPX-7400_SPX-7410_MAN_161028

W3-M. Metal waterproof standalone access control/reader. User Manual

F11 Installation Guide. Version: 1.0 Date: Jul. 2010

Suprex RF Series CYPRESS. Operations Manual. Suprex Reader Extender - RF Wireless Interface EXP SPX Mhz SPX-5521_MAN_0316

Cardax FT Controller 3000

B-33. Hardware and Install Manual. (DC 12V / PoE)

1 IF-812 or IF-815 Terminal (Slave) 2 Intended Use. 3 Assembly and Installation _V IF-812/IF-815

PR402 v2.0 Installer Manual Rev.C

EL-ST100 KEYPAD CONTROLLER

Suprex Ethernet SPX-7200 Ethernet Reader-Extender

ACT 5e prox Operating and Installation Instructions ACT Product Code: ACT 5e prox

Installation Instructions for the AUTOcard-SA System

GV-AS/EV Controller. User s Manual

Operation Manual. Thank you for selecting Keyking products. Please read this manual thoroughly before use. Models: TC418/419 Standalone Controller

INSTALLATION GUIDE. InBio Pro Series Access Control Panels. Date: June, 2016 Version: 1.3

April 2015 PRICE SCHEDULE A 2.0 Stand-Alone Access Control

Quick Start Installation Guide

Transcription:

SPECIFICATIONS Working Environment Plastic Housing... Power NEXUS LITE Amano Nexus Lite Controller INSTALLATION MANUAL MODEL NUMBER: ISC920-0-0-AC-XX ISC921-5-0-AC-XX Designed to work in an indoor (dry) environment similar to IP40. The Controller is not sealed against water. Input Voltage... 10 V DC to 30 V DC, polarity sensitive. Power Requirements (ISC920) Current (ma) Power (W) 12 V DC with no peripherals connected and relays off... 75 0.90 24 V DC with no peripherals connected and relays off... 40 0.96 Power Requirements (ISC921) 12 V DC with no peripherals connected and relays off... 130 1.56 24 V DC with no peripherals connected and relays off... 60 1.44 Relay Power Requirements... An additional ~0.4 W per Relay in use. Real Time Clock (RTC) Backup Battery Battery Type... 1 x 3 V, CR2032, Lithium cell Battery. Battery Life... 2 years with power OFF, 5 years with Power ON, 5 years storage with Battery Tab in place. Controller Communication Ethernet Port... Standard Ethernet RJ45 connector. 10/100 Base T, half or full duplex.

Terminal Communication RS485 Terminal Port Electrical Interface... RS485. Baud Rate... 38 400. RS485 Terminal Port (Continued) Data Format... Communications Protocol... Line Termination (RS485)... Reader Options 8 data bits, no parity, 1 stop bit. Secure Communications Protocol. Provision is made for line termination. Reader 1 Wiegand and Reader 2 Wiegand allow connection to the Amano (MDR) Multidiscipline Reader and Wiegand Readers. The function is selectable via the DIPswitches (See Table 1). Power Output... Modes Supported... Electrical Interface... Communications Protocol... Relays Relay Output... Relay Contact Ratings... Operations... Digital Inputs 12 V DC and 5 V DC (selectable) at maximum 200 ma. Tag + PIN-code or Reason Code. TTL Full Duplex. Proprietary Protocol. 2 Relays, Form C, each with NO, COM and NC contacts. 10 A at 28 V DC, 5 A at 220 V AC, 10 A at 120 V AC. 100 000 Minimum. General Type... Detection Resistance Range... Protection Range... 4 Dry-contact inputs. < 2 kohm. +15 V continuous. Blank Space ISC304-0-0-AC-04 November 2010 Page 2

NOTE: Door Lock General Figure 1: End of Line (EOL) Sensing Circuit End of Line (EOL) Sensing enables the Controller to raise an alarm when somebody tampers with the circuit (that is, cutting or shorting the wires) between DOS [1] and GROUND (GND). In other words the Controller distinguishes between tampering on the circuit, and the door being in an actual Normally Open state. By placing Resistors into the circuit between DOS [1] and GROUND (GND), the Controller s Digital Input monitors a constant resistance through the circuit. When the circuit is tampered with, the Resistors are bypassed; the Controller detects the resistance change raising an alarm. Type... Protection Range... Frequency... Read Capability... Controller Diagnostic Indicators Buzzer Volume and Tone... Display (ISC921 Only) Type... 2 Dry-contact inputs. +15 V continuous. 125 khz and 13.56 MHz. Slim Tags, Omega Tags, Mifare Standard, Mifare Ultralite, FeliCa, Desfire, HID iclass, WriTag 128 and WriTag 2048. CAUTION: NOTE: The Nexus Lite System does not support the use of HID 1346 Proxkey II Tags. HID, FeliCa and MIFARE are registered trademarks of HID Global Corporation (an ASSA ABLOY Group Brand), The Sony Corporation and Koninklijke Phillips Electronics N.V. respectively. Single tone, with a 3-step adjustable volume. Thin Film Transistor Liquid Crystal Display (TFT-LCD). ISC304-0-0-AC-04 November 2010 Page 3

Display (continued) Resolution... Color... Back-lighting... Status LED Power On... Upgrade Mode... Incoming RS485 Data... Outgoing RS485 Data... Digital Inputs (1-4)... Relays (1 and 2)... Locked... Unlocked... Enet Act (Ethernet Activity)... Enet Spd (Ethernet Speed)... Enet Lnk (Ethernet Link)... 240 x 320 Pixels. 65 K Color Screen. Permanently on. Continuous Red. Flashing Red. Flashing Green LED. Flashing Red LED. Continuous Green on detected contact closure. Continuous Red on activation of the Relay. Continuous Green when locked. Continuous Green when unlocked. Flashing Red LED. Continuous Red for 100 Mbps (Default) Off for 10 Mbps. Continuous Red on connection to network. INSTALLATION INFORMATION Accessories CAUTION: The Nexus Lite Controller needs a standard Ethernet cable to connect to a PC. We do NOT however supply this cable with the Controller s accessories. Find the following when unpacking the Amano Nexus Lite Controller: Either an Amano Nexus Lite Controller with Web Interface (ISC920) supplied in a Black ABS Plastic housing. The housing consists of a Front Cover Assembly and a Mounting Plate. The Front Cover and Mounting Plate are held together with two Combi Screws (M4 x 10 mm) at the bottom of the housing. Or, an Amano Nexus Lite Controller with Touch Screen (ISC921) supplied in a Black ABS Plastic housing. The housing consists of a Front Cover Assembly and a Mounting Plate. The Front Cover and Mounting Plate are held together with two Combi Screws (M4 x 10 mm) at the bottom of the housing. CAUTION: NOTE: DO NOT use the Metal-oxide Varistors (25 Vrms, 500 A, 77 V max clamping) with mains power applications. Three Metal-Oxide Varistors, 25 Vrms, 500 A, 77 V max clamping. A 3 V, CR2032, Lithium cell Battery. The 3 V, CR2032 Lithium cell Battery is partially installed in all models of the Nexus Lite Controller. An extra Fixed Address Label. ISC304-0-0-AC-04 November 2010 Page 4

General Remember the following when installing the Nexus Lite Controller: Communications Distance RS485 Terminal Port The RS485 communications distance between the Nexus Lite Controller and the LAST Amano Terminal in a cable run, MUST NOT exceed 1 km (1 090 yd). Achieve this by using good quality screened, twisted 2-pair cable, with the screen EARTHED at one end. Jumper Links Long transmission lines or multiple star connections, may cause communication problems. Placing a Jumper Link across the jumper (See Figure 3 for position) in the LAST UNIT AT THE END OF THE CABLE RUN should solve the problem. Distance between the Controller and its Wiegand or Multi-Discipline Readers CAUTION: When implementing the 150 m (164 yd) cable distances with Amano Wiegand Readers use the 12 V power output option. Note, however, that the Multi-discipline Readers only connect using the 12 V power output option. For maximum, data communications distance, install the Readers no further than 150 m (164 yd) from the Controller. The cable individual conductor cross-sectional area should not be less than 0.2 mm 2 (0.0003 in 2 ). Distance between Amano Units You can mount Nexus Lite Controllers (ISC920) directly next to each other. To avoid mutual interference, install the Touch Screen Nexus Lite Controllers (ISC921) at least 500 mm (20 in) apart. To avoid mutual interference, install the Wiegand Readers or Multi-discipline Readers at least 500 mm (20 in) apart. EARTH Connection Connect the Nexus Lite Controller to a good EARTH point. Using the RS485 Port, connect the ETH Lead to the ETH Terminal. Mains EARTH can be used, but electrical noise may exist. CAUTION: When using the Nexus Lite Controller with FCC approved accessories, ensure that the RS485 cable is routed through a separate grommet to the power cable. Also ensure that you use a CE approved Power Supply Unit. Blank Space ISC304-0-0-AC-04 November 2010 Page 5

Arc Suppression Snubber devices are recommended for EMF Flyback and Arc Suppression when driving an inductive load with the Relay, see Figure 2. Figure 2: EMF Flyback and Arc Suppression Installing the Real Time Clock (RTC) Backup Battery CAUTION: Remove the Battery Tab for the Real Time Clock from the Battery Holder BEFORE powering up the Nexus Lite Controller. First Time Use 1. Ensure that power is NOT applied to the Controller. 2. Locate the removable Battery Tab. 3. Pull the removable Battery Tab out of the Battery Holder. 4. Apply power to the Controller. Replacement NOTE: Because of the delicacy of this procedure, we recommend you contact your distributor before trying to replace the Battery. Mounting the Nexus Lite Controller CAUTION: Make certain that you mount the Controller on a vibration-free surface. NOTE: You can mount the Nexus Lite Controller onto virtually any surface including metal. Select the mounting position of the Nexus Lite Controller, considering accessibility, routing of wires and visibility of the Thin Film Transistor Liquid Crystal Display (TFT-LCD) and accessibility of the Keypad. Secure the enclosure to the mounting surface, using four suitable screws and wall plugs, nuts and bolts or rivets. Blank Space ISC304-0-0-AC-04 November 2010 Page 6

DIP-switch Settings NOTE: Once the DIP-switch settings are modified reset the Nexus Lite Controller to acknowledge the new settings. Reader 1 Select and Reader 2 Select DIP-switch Settings Each of the Reader Ports has a 4-way DIP-switch to select the function of that Port. NOTE: NOTE: Where you have no Advanced Wiegand Readers (Amano Multi-discipline Readers) attached, setting both Reader DIP-switches to the all off position during an Auto-ID will not return any Fixed Addresses. Because of the way standard Wiegand Readers handle HID Tag codes, Nexus Lite Sites using standard Wiegand Readers can only support one of two options: HID Tags only or any other Tag type (that is Slim Tags, Omega Tags, Mifare Standard, Mifare Ultralite, FeliCa, Desfire, WriTag 128 and WriTag 2048 depending on the Reader). For HID Tags only, set the DIP-switch to Wiegand Open Format and the Wiegand Reader to HID Raw Mode. For any other Tag type, set the DIP-switch to Wiegand 26-bit/44-bit. For more information refer to Table 1. If you need a combination of HID Tags and other Tag types, make use of the Amano Multi-discipline Readers. DIP-switch Position Connections 0 Advanced Wiegand Reader (Amano Multi-discipline Readers). Full Tag codes and types. 1 Reserved. 2 Reserved. 3 Reserved. 4 Reserved. 5 Reserved. 6 Reserved. 7 Wiegand 26-bit, 44-bit, 40-bit, 37-bit and Tag + PINcode or Reason Code Mode. ISC304-0-0-AC-04 November 2010 Page 7

DIP-switch Position Connections 8 Wiegand Open Format. 9 10 11 12 If the Amano RF is connected, then Button 1 of the Amano (QT) Quad Transmitter reports. If the Amano RF is connected, then Button 2 of the Amano (QT) Quad Transmitter reports. If the Amano RF is connected, then Button 3 of the Amano (QT) Quad Transmitter reports. If the Amano RF is connected, then Button 4 of the Amano (QT) Quad Transmitter reports. Table 1: Reader 1 Select and Reader 2 Select DIP-switch Settings Door Lock Select DIP-switch Settings DIP-switch Position Connections 0 No special lock control. 1 Motor Lock. 2 Pulse or Repeating Lock. 3 Fail Safe or Fail Secure with Locked or Unlocked Status (Solenoid Lock). 4 Normal Lock, no Lock or Unlock Sensors, only Emergency Mode support. 5 Returns Controller to Factory Default Settings. NOTE: Return Switch 1 to the OFF position to resume normal operation. Table 2: Door Lock Select DIP-switch Settings Blank Space ISC304-0-0-AC-04 November 2010 Page 8

Wiegand Modes Mode Tag Only: Tag + PIN: Tag + Reason: Terminal Action Treats all codes received as tag codes. Treats the first Wiegand code received as the tag code, and the second Wiegand code received as the PIN-code. Treats the first Wiegand code received as the tag code, and the second Wiegand code received as the Reason Code. Table 3: Wiegand Modes Wiegand Mode Rules Enter PIN-codes or Reason Codes on the Reader within 10 seconds otherwise the Controller discards the tag code. If the Nexus Lite Controller expects a PIN-code and receives a number greater than 65535, then the Controller assumes the number to be a tag code. The Controller discards the previously read Tag for the current one and the Controller will still expect a PIN-code. If the Nexus Lite Controller expects a Reason Code and receives a number greater than 65535, then the Controller assumes the number to be a tag code. The Controller discards the previously read Tag for the current one and the Controller will still expect a PIN-code or Reason Code, depending on the mode. If the Controller expects a Reason code and instead receives a number in the range 100 to 65535, the Controller assumes this is an error. The Controller discards the entire transaction, entering a new tag code starts the process again. If using PIN-codes and Reason Codes set the Nexus Lite Controller switches for Wiegand 26-bit, 37-bit, 40-bit and 44-bit, not Wiegand open format. Blank Space ISC304-0-0-AC-04 November 2010 Page 9

ELECTRICAL CONNECTIONS Key Component Positions Figure 3: Nexus Lite Controller Key Component Positions ISC304-0-0-AC-04 November 2010 Page 10

Connecting the Nexus Lite Controller Figure 4 shows a typical electrical connection diagram for the Nexus Lite Controller. Figure 4: Typical Nexus Lite Controller Electrical Connections ISC304-0-0-AC-04 November 2010 Page 11

Figure 5: Nexus Lite Controller connected to Wiegand Reader ISC304-0-0-AC-04 November 2010 Page 12

Figure 6: Nexus Lite Controller connected to the Amano RF ISC304-0-0-AC-04 November 2010 Page 13

Figure 7: Motor Lock Connection Details ISC304-0-0-AC-04 November 2010 Page 14

Figure 8: Solenoid Lock Connection Details ISC304-0-0-AC-04 November 2010 Page 15

ADVANCED SETTINGS Restoring Factory Default Settings CAUTION: The procedures below are Controller specific. Ensure that you follow the correct procedure for your model Controller. Failure to do so results in loss of the Database. Restore the Controller s factory default settings as follows: ISC920 1. Remove the Controller s Front Cover Assembly. 2. Set the Door Lock Select DIP-switch Switch 1 to the ON position (see Table 2, row 5 for details). 3. Reset the Controller by removing and then reapplying the power source. 4. With the Controller running, set the Door Lock Select DIP-switch Switch 1 back to the OFF position. 5. Reattach the Controller s Front Cover Assembly. ISC921 CAUTION: Ensure that you return Switch 1 of the Door Lock Select DIP-switch to the OFF position. Failure to do so automatically clears the System Database on the next restart. 1. Remove the Controller s Front Cover Assembly. 2. With power applied to the Controller, toggle switch 1 of the Door Lock Select DIPswitch ON and then OFF. 3. Complete the Action textbox, by clicking the button and selecting from the following: No Change maintains user settings. Reset Admin Password restores the administrator password to factory default (12345) without resetting the System Database. Reset System Database clears the Database, restoring it to factory default settings. 4. Click the button. 5. Click the button. 6. Reattach the Controller s Front Cover Assembly. UNIT ADDRESS INFORMATION Fixed Address Once the Nexus Lite Controller is installed, sketch a rough site plan. Attach the loose (additional Fixed Address Label packaged with the Controller) Fixed Address Label in the position of the Controller on the sketched site plan. When the system installation is complete and all the units are represented on the site plan by their Fixed Address Labels, file the site plan for future reference. ISC304-0-0-AC-04 November 2010 Page 16

The Fixed Address Label included with the Controller is the Fixed Address for the Controller only. In addition to the Controller Fixed Address, the Nexus Lite Controller reports up to two Terminal Fixed Addresses. Controller s Fixed Address: 6E XX XX XX. Reader 1 s Fixed Address: 6F XX XX XX. Reader 2 s Fixed Address: 70 XX XX XX. NOTE: Where additional Terminals connect to the Controller, extra Fixed Addresses for the respective Terminals appear during the Software s Auto- ID process. MAC Address Figure 9: Sample MAC Address Label Each Nexus Lite Controller is supplied with a separate MAC Address Label, much like the one shown in Figure 9, which uniquely identifies each Controller. Attach the extra loose MAC Address Label, alongside the Fixed Address Label, to the Unit Location Chart enclosed (or your sketched site plan). IP Address NOTE: All Amano Nexus Lite Controllers have the same IP Address (192.168.100.1). In the absence of a DHCP server, plug each Controller into the network individually and set the static IP Address. Unit Location Chart Fixed Address Label Unique Location Description ISC304-0-0-AC-04 November 2010 Page 17

Fixed Address Label Unique Location Description ISC304-0-0-AC-04 November 2010 Page 18

Fixed Address Label Unique Location Description ISC304-0-0-AC-04 November 2010 Page 19

Fixed Address Label Unique Location Description ISC304-0-0-AC-04 November 2010 Page 20

Fixed Address Label Unique Location Description Table 4: Unit Location Chart GUARANTEE OR WARRANTY CAUTION: We reserve the right to nullify the products guarantee or warranty where you have not properly installed the Metal-oxide Varistors. This product conforms to our Guarantee or Warranty details placed on our Web Site, to read further please go to www.amano.com. USER NOTES ISC304-0-0-AC-04 November 2010 Page 21

USER NOTES ISC304-0-0-AC-04 November 2010 Page 22

USER NOTES ISC304-0-0-AC-04 November 2010 Page 23

Security Systems Division 180 Alt. 19, Suite A, Palm Harbor, FL 34683 Technical Support: (800) 390 5837 Corporate Headquarters 140 Harrison Avenue, Roseland, NJ 07068-1239, (800) 526-2559 www.amano.com This manual is applicable to the Amano Nexus Lite Controller, ISC920-0-0-AC-03 and ISC921-5-0-AC-03. (The last two digits of the Amano stock code indicate the issue status of the product). ISC304-0-0-AC-04 Issue 05 Nov 2010 Controller\English Manuals\LATEST ISSUE\ ANLite-insm-en-05.docx ISC304-0-0-AC-04 November 2010 Page 24