KEY BENEFITS APPLICATIONS FEATURES

Similar documents
B30. Multilin BUS DIFFERENTIAL SYSTEM. Cost effective low impedance biased bus differential protection for up to six feeders KEY BENEFITS APPLICATIONS

F35. Multilin FEEDER PROTECTION SYSTEM. Cost-effective protection and control for single/multiple distribution feeders KEY BENEFITS APPLICATIONS

T35. g Multilin. Cost effective differential protection for transformers with up to 6 sets of CTs. Protection and Control

N60. Network Stability. Load shedding, remedial action, special protection schemes and synchrophasors. Features. Protection and Control

L90. Multilin LINE CURRENT DIFFERENTIAL SYSTEM. Phase segregated line current differential and distance protection KEY BENEFITS APPLICATIONS FEATURES

Multilin B30. Low Impedance Biased Bus Differential Protection for up to Six Feeders. Protection and Control. Communications.

N60. Multilin. NETWORK STABILITY & SYNCHROPHASOR MEASUREMENT Synchrophasors, load shedding, remedial action, special protection schemes KEY BENEFITS

T35. Multilin TRANSFORMER PROTECTION SYSTEM. Cost-Effective Differential Protection for Transformers with up to 6 Sets of CTs KEY BENEFITS

GE Power Management. UR F60 Feeder Management Relay An integrated feeder protection and metering solution

C30. Multilin CONTROLLER SYSTEM. Substation Hardened Programmable Logic Controller KEY BENEFITS APPLICATIONS FEATURES. IEC Process Bus Interface

T60. Multilin TRANSFORMER PROTECTION SYSTEM. Fully featured, multiple winding transformer protection KEY BENEFITS APPLICATIONS FEATURES

G30. Multilin GENERATOR PROTECTION SYSTEM. Protection for Small to Medium Generators, Combined Generators and Transformers KEY BENEFITS APPLICATIONS

L60. Multilin LINE PHASE COMPARISON SYSTEM. Sub-Cycle Phase Comparison and Distance Protection KEY BENEFITS APPLICATIONS FEATURES

B90. Low Impedance Bus Differential System. Instruction Manual AB1. GE Digital Energy

B30 Bus Differential Relay

g GE Power Management UR - The Universal Relay

M60 Motor Relay. UR Series Instruction Manual. GE Industrial Systems. Title Page. M60 Revision: 3.4x

Multilin N60. Protection & Control. Synchrophasors, Load Shedding, Remedial Action, Special Protection Schemes. Communications. Monitoring & Metering

B30 Bus Differential Relay

L90. Multilin LINE CURRENT DIFFERENTIAL SYSTEM. Line Protection System with Segregated Line Current Differential and Complete Distance Protection

Multilin D30. High-Speed Primary and Backup Distance Protection. Protection & Control. Advanced Communications. Cyber Security. Monitoring & Metering

SEL-487B. A Powerful Solution for Busbar Differential Protection. Bus Differential and Breaker Failure Relay

Bus Differential and Breaker Failure Relay. Advanced bus protection with built-in breaker failure detection

D60. Multilin LINE DISTANCE PROTECTION SYSTEM. High-speed transmission line protection with three/single pole tripping KEY BENEFITS APPLICATIONS

Bus Bar Protection Applications Seminar

The engine for substation automation. g Power Management. The Universal Relay. The Universal

Bus Differential and Breaker Failure Relay. Advanced bus protection with built-in breaker failure detection

N60 Network Stability and Security Relay

C60. Multilin BREAKER PROTECTION SYSTEM. Breaker Monitoring and Control for Substation and Industrial Automation KEY BENEFITS APPLICATIONS FEATURES

Bus Protection Application Challenges

Bus Differential and Breaker Failure Relay. Advanced bus protection with built-in breaker failure detection

T60. Multilin TRANSFORMER PROTECTION SYSTEM. Full-Featured, Multiple-Winding Transformer Protection KEY BENEFITS APPLICATIONS FEATURES

MiCOM Agile P746. Grid Solutions. Key Benefits. Numerical Busbar Protection. A Combination of Speed, Security and Selectivity. About MiCOM P40 Agile

C70. Multilin CAPACITOR BANK PROTECTION SYSTEM. Capacitor Banks Protection & Control KEY BENEFITS APPLICATIONS FEATURES

UR Universal Relay Series

N60 Network Stability and Synchrophasor Measurement System

Multilin G60. Grid Solutions. Comprehensive Protection for Generators. Protection and Control. Advanced Communications.

C30. Controller System. Instruction Manual AF2. GE Grid Solutions. Product version: 7.6x GE publication code: AF2 (GEK A)

Multilin F60. Advanced Protection, Control & Automation for Distribution Feeders. Protection & Control. Communications.

F650 - More than Feeder Protection & Control. GE Consumer & Industrial Multilin

F60. Multilin FEEDER PROTECTION SYSTEM. Advanced Protection, Control and Automation for Distribution Feeders KEY BENEFITS APPLICATIONS FEATURES

Busbar protection REB 670

Multilin T60. Grid Solutions. Protection & Control. Full-Featured, Multiple-Winding Transformer Protection. Communications. Monitoring & Metering

Multilin F60. Grid Solutions. Advanced Protection, Control & Automation for Distribution Feeders. Protection & Control. Advanced Communications

GE Multilin 350 Feeder Protection Relay Specifications

High-speed transformer differential protection for up to five terminals

UR Universal Relay Series

UR Universal Relay Series

SR489 SR489. Generator Management Relay. Economical protection, metering, and monitoring functions for small and medium sized generators.

www. ElectricalPartManuals. com C60 Breaker Management Relay UR Series Instruction Manual GE Industrial Systems C60 Revision: 2.9X

MiCOM P521. Fast Feeder Differential Protection

IDM DATA ACQUISITION SYSTEM

DS Agile C264. Grid Solutions. Dual-bay Modular Substation Controller. Multi-function Controller. Automation and Control. Advanced Communication

Relion 615 series Line Differential Protection and Control RED615 Ver. 2.0 Technical Presentation

MiCOM P521. Fast feeder differential protection

Substation Automation Products. Generator protection REG670/650 Relion 670 and 650 series

750/760 Feeder Management Relay Instruction Manual

Distributed bus protection application in a platform for process bus deployment in the SMART SUBSTATION

MiCOM P721 & P723. Numerical High Impedance Differential Relay. Protection Relays. Customer Benefits

Deploying Digital Substations: Experience with a Digital Substation Pilot in North America. Harsh Vardhan, R Ramlachan GE Grid Solutions, USA

MiCOM P122C Time-Overcurrent Protection

SEL Time-Domain Link (TiDL ) Technology

Perfect protection smallest space

Bus Bar Protection Relay B-PRO 4000

Advanced Line Differential Protection, Automation, and Control System. Combine subcycle line protection with traveling-wave fault locating

Transformer Protection and Control RET630 Numerical transformer protection in medium voltage networks

Substation Automation Products. High impedance differential busbar protection REB650 Relion 650 series

Protection, Automation, and Control System. Combine subcycle line protection with complete substation bay control

SR750/760 Feeder Management Relay

Substation Automation Products. Transformer protection RET670/650 Relion 670 and 650 series

Mehta Tech, Inc. TRANSCAN IED For Multi-Function, Multi-Speed Recording

Protection, Monitoring, and Control System for Distribution Substations ALARM HISTORY SYSTEM COMM. On-Line Documentation TRANSFORMER 12 MW

UR Universal Relay Series

MIN II. Complete numerical ground directional protection. Digital Energy Multilin. Protection and Control. Monitoring and Metering.

SIPROTEC 5 V7.8 Protection, automation and monitoring for digital substations

SEL Real-Time Automation Controller (RTAC)

Industrial & Plant Communication Applications Seminar. April 3, 2006 College Station TX

SR 469 Motor Management Relay

Release 5.83 of the Universal Relay (UR) series introduces improvements for general and protection functions. Highlights of version 5.

SR 750 Feeder Management Relay

SOLUTIONS FOR AN EVOLVING WORLD RFL GARD Protective Relay & Communications System RFL GARD SFPLC 1

Packaged Solutions. Grid Solutions. Value Added Solutions for Protection, Control and Automation Applications. Flexible and Expandable

Relion 615 series Transformer Protection and Control RET615 Ver. 2.0 Technical Presentation

Recloser Controller for feeder protection and automation siemens.com/distribution-automation

SIPROTEC 7SC80 Feeder Protection and Automation Answers for infrastructure and cities.

A low-cost, economical solution for distribution feeder protection

INTELLIGENT ELECTRONIC DEVICE DATA EXTRACTION AT HYDRO ONE. Sheng Hsu Senior Protection & Control Engineer Hydro One

Automation System Solutions

1. Project Description

Substation Automation Products. Line differential protection RED670 Relion 670 series

UR Plus Series. Revision 1.73 Release Notes. GE Digital Energy. Overview. GE Publication Number: GER Summary. Copyright 2013 GE Multilin Inc.

Designing a new IEC substation architecture

Npefm!681F! !!!681F!Gjcfspqujd!Usbotdfjwfs! Gjcfspqujd!Ofuxpsl!Tpmvujpo!! Model 570E Features. The Fiberoptic Communications Specialists

SIPROTEC 5 Application Note. Breaker-and-a-half solutions. SIP5-APN-002, Edition 2.

SOLKOR-N (7SR18) Feeder Differential Protection. Make the ight choice! Choose EYROLLE Protection

UNITROL 5000 Excitation Systems for Medium and Large Synchronous Machines

Grid Automation Controller COM600 How it fits into the Smart Grid?

Version 7.6x Release Notes

MiCOM P124 T&D. Self and Dual Powered Overcurrent Relays

NEO 3000 Substation System THE FAMILY OF EQUIPMENT DEDICATED FOR POWER UTILITIES. Energy Sector

Transcription:

KEY BENEFTS Easily meet stability requirements - sub-cycle trip time (average of 0.75 power cycle, maximum 1 power cycle) Dependable and secure - Performance backed up by many years of field experience Cost effective alternative to high impedance schemes Scaleable and expandable architecture to protect up to 24 feeders Engineered solution available - Use highly experienced Multilin application engineers to develop a busbar protection system Breaker Failure option Maintenance cost savings and simplification - Modular construction,common hardware, reduced stock of spare parts, plug & play modules APPLCATONS Re-configurable multi-section busbar with up to 24 feeders (8, 1, 24 feeder configurations available) FEATURES Protection and Control Multi-zone bus differential protection with restrained and unrestrained function Sub-cycle tripping time Fast and reliable CT saturation detection Check-zone functionality Dynamic Bus Replica Breaker failure protection End fault protection OC and TOC Undervoltage function for supervision purposes Communications Networking options - Ethernet-fiber (optional redundancy), RS422, RS485, G.703, C37.94 Multiple protocols - EC 1850, DNP 3.0 Level 2, Modbus RTU, Modbus TCP/P, EC 0870-5-104 Direct /O - Exchange of binary data between URs Use high speed communications to reduce wiring and installation costs - Exchange inputs and outputs between relays to achieve relay-to-relay interaction Cost effective and flexible access to information - Multiple communication options and protocols Reduce installation space requirements through compact design - Multifunction device that integrates protection and control functions, programmable pushbuttons and status LEDS, communication interfaces Application flexibility - Multiple /O options, programmable logic (FlexLogic ), modularity, customize to specific requirements Reduce system event analyzing time and cost - Sequence of event reports, oscillography, RG-B time synchronization Breaker monitoring - Monitor breaker conditioning through analog /O, rich metering, and trip counters Embedded EC 1850 Protocol - No external protocol converters required Single Bus, Double Bus (with transfer schemes), Triple Bus configurations Monitoring and Metering solator monitoring (up to 48) and alarming Metering - current, voltage, frequency Oscillography - 4 samples/cycle, up to 4 records Event Recorder - 1024 time tagged events, with 0.5 ms scan of digital inputs User Programmable Fault Reports User nterface and Programming Front panel display and keypad for local access; RS232 port for local PC access User programmable local display, LEDs and pushbuttons Customize protection and control functions with FlexLogic, FlexCurves, and FlexElements ncludes Enerista LaunchPad - Simple relay setup and programming Multi-language - French, Chinese, Russian option 117

Protection and Control The B90 Bus Differential System provides fast and secure low impedance bus protection for reconfigurable L, H, and EH busbars. Use one B90 to protect up to 8 feeders and use three or more B90s together in a centralized phase segregated architecture to protect up to 24 feeders. Many busbar applications such as single, double, triple, breaker-and-a-half with or without transfer bus are possible. The B90 is ideally suited in applications where high impedance schemes were typically used. Bus Differential Protection The B90 provides fast and secure low impedance bus protection with sub-cycle tripping time averaging 0.75 cycles. t incorporates patented algorithms that works with only 2ms of saturation free currents, and takes advantage of the high sampling rate of 4 samples per cycle to provide exceptional through-fault stability. Multiple phase-segregated zones of differential protection is available in the B90 The primary protection is based on differential and directional protection principles, and uses a dedicated CT saturation mechanism for extra throughfault stability. This mechanism is capable of detecting saturation of CTs as quickly as two milliseconds into an external fault. With no CT saturation detected, the relay uses only the differential principle for faster operation. Reduce overall system costs with the B90 since there is no need for dedicated, or interposing, CTs. The B90 includes advanced features, such as breaker failure, CT trouble detection, under-voltage supervision, and dynamic bus replica. Due to its extreme flexibility, which includes a CT ratio mismatch of up to 32:1 between terminals, the B90 is the ideal solution in a wide variety of bus differential applications. The B90 can be equipped with an optional redundant dual power supply for increased reliability in all critical protection applications. Architecture The B90 is based on a centralized phasesegregated architecture that does not rely on extensive communications between EDs, an approach that increases overall reliability. This architecture allows for great flexibility and is scalable to any low impedance busbar protection application, all in a relatively small form factor. Each unit in the system is capable of exchanging digital states quickly and reliably over a dedicated, redundant fiber optics connection. The B90 communication capability allows the user to distribute input and output contacts freely in various EDs. The B90 protection system can incorporate as few as one unit and as many as five units to accommodate a wide range of applications. This scalability and flexibility allows for optimum hardware utilization with an overall lower system costs then was previously possible. A single B90 configuration is available to protect up to 8 feeders. A more typical B90 configuration for non-re-configurable busbars without breaker fail protection consists of three URs. This configuration can protect up to 24 feeders. Each B90 in the system can also be configured to support multiple /O configurations (up to 48 inputs and up to 18 outputs on each unit). f breaker failure, isolator monitoring functions, and more /O points are needed, Functional Block Diagram Typical B90 configurations. Breaker position & trip 50 27 50 50 27 50 51 51 51 51 50BF 50BF 50BF 50BF ZONE 1 ZONE 2 solator position solator Monitoring & Dynamic Bus Replica Metering: A,, Hz ZONE 3 ZONE 4 B90 BUS DFFERENTL SYSTEM 83752 A3.CDR ANS DECE NUMBERS AND FUNCTONS DECE NUMBER 27 50 50/74 50/87 51 50BP FUNCTON Undervoltage nstantaneous Overcurrent CT Trouble Unrestrained Bus Differential Time Overcurrent Breaker Fail 118

an additional B90 can be added into the system. A fifth unit can also be added for even more /O capabilities. The standard features offered by all URs, including multiple SCADA interface options, wide area network integration, multiple communication mediums and protocols, extensive offering of /O options, put the B90 ahead of an average busbar relay, making it an ideal and economical solution for substation integration and automation. Dynamic Bus Replica The B90 provides a dynamic bus replica for each zone of differential protection. Built-in programmable logic removes the need for external auxiliary relays, and provides the ability to include or exclude currents dynamically from the differential zone. This allows the B90 to follow the actual busbar configuration with no external switching of CT circuits required. The B90 also avoids blind and overtripping spots in simple bus configurations. Reliability is increased and costs reduced by eliminating auxiliary relays that would otherwise be used for switching physical currents. The ability to monitor auxiliary switches and a contact discrepancy alarm, also provides increased security. Breaker Failure Protection Three-pole breaker failure (BF) protection is available. The B90 system provides for up to 24 BF elements that can respond to currents and/or auxiliary contacts. The current sensors with fast reset time and three separate settings for low-set, hi-set and supervision are implemented in the phase EDs. The BF can be initiated internally from the busbar protection or externally via input contacts or communications. A re-trip function is also included. Backup Protection Backup protection is available with instantaneous and time overcurrent functions for each current input of the B90 system. For supervision purposes, an undervoltage function is also provided for each voltage input of the B90 system. The B90 can be used as a SCADA gateway for backup analog and/or high-impedance legacy products found in an existing installation. OC Functions: One OC function is incorporated for each CT input of the relay. Up to 24 OCs are available for trip Bus currents and important logic signals related to external fault. Despite very fast and severe CT saturation, the B90 remains stable. supervision or other user-configurable applications. Backup Overcurrent Protection: One TOC function is incorporated for each CT input of the relay. Up to 24 TOCs are available for backup protection. The TOC function can use standard or userprogrammable curves. oltage Supervision: One undervoltage element is available per each T input of the relay. This function may be used to supervise (release) the current-based protection functions for extra security. End Fault Protection Faults between a line-side CT and an open CB cannot be cleared by the bus protection. Moreover, the main bus differential protection must not respond to these faults. This requirement is accomplished by using a CB position for the dynamic bus replica image in order to terminate the zone on a CB rather than a CT if the CB is open. As a result, a dead-zone is created between the CT and CB. The End Fault Protection (EFP) feature is provided to detect faults in dead-zones. One EFP element is provided per each CT input. The element can be configured to trip a remote breaker via communications channels. Check-Zone The B90 provides for multiple zones of differential protection. One zone can be configured to encompass the entire busbar in order to act as a supervisory check zone for other zones of protection. CT Trouble Monitoring One CT trouble monitoring function is provided for each zone of differential protection. The element is a definite time TOC function responding to a differential current. The CT trouble element shall be used in conjunction with undervoltage supervision or a check zone. Monitoring and Metering The B90 includes comprehensive recording, metering, and monitoring functions that reduce the need for dedicated Digital Fault Recorders and Sequence of Event Recorders. Troubleshooting is made easy with recording of differential and restraining currents, and other signals key to relay performance High accuracy metering and fault recording of voltage and current on a per circuit basis are built into the relay as a standard feature. Current parameters are available as total waveform RMS magnitude, or as fundamental frequency RMS magnitude and angle (phasor). Diagnostics features such as oscillography and event recording, combined with Enerista software tools, significantly reduce troubleshooting time and simplify report generation in the event of a system fault. 119

Oscillography Configure up to 4 oscillography channels to monitor any physical /O point or internal digital and analog variables. The waveform traces and digital states provide a visual display of the busbar and operational data captured during specified triggered events. Sampling rates are up to 4 samples/cycle and 4 fault records can be stored on the unit. Event Recorder Capture the last 1024 events, with 0.5ms scan of digital inputs, to provide SOE recorder functionality. Consolidate the event records from multiple devices using Enerista software tools and use the RG-B time synchronization feature to synchronize all events across a system of URs for even more accurate analysis and troubleshooting. solator Monitoring Each B90 provides up to 48 isolator monitoring functions. f more isolators are to be monitored an extra ED can be added. Both normally open and closed auxiliary contacts are used for isolator monitoring. Standard contact discrepancy logic is implemented to cope with invalid positions of the auxiliary switches. An acknowledgeable discrepancy alarm is produced that can be configured to block selected protection functions. Also, a signal is produced to block switching operations in the substation as long as the bus image is not resolved by the B90. The bus image is refreshed every two power system cycles. User nterface and Programming The B90 front panel provides extensive local HM capabilities. The local display is used for monitoring, status messages, fault diagnosis, and relay configuration. User configurable messages that combine text with live data, can be displayed when user defined conditions are met. A keypad is also provided for easy access and changes to relay settings. Replace external indicator lights with 48 user programmable LEDs to display key status information. An additional 14 pre-programmed LEDs and custom LED labeling are available. Use the LEDs to provide a local visual status of the bus. For a typical B90 system, over 100 LEDs are available. An RS232 port for local PC access is provided on the front panel for convenient access to the relay through Enerista LaunchPad. The Ethernet port allows for even easier access to the relay over the network. User-Programmable Push Buttons Perform manual control, operate breakers, or lock out functions, with the userprogrammable pushbuttons. Replace external switches and bi-stable relays by using mechanically latching outputs controlled from the pushbuttons. The B90 can be ordered with 7 user programmable control pushbuttons (3 standard, 4 optional) and 12 large user-programmable push buttons (optional). The control action of each push button is fully programmable and its operation can be logged directly in the Sequence of Events recorder to enhance troubleshooting. The push buttons can be easily labeled for added clarity of functionality. Multi-Language The B90 supports multiple languages. French, Chinese, Russian language options are available on the local display, front panel, and Enerista setup software, as well as the product instruction manual. Easily switch between English and an additional user selectable language on the local display. FlexLogic, FlexCurves The B90 comes with powerful configuration and programming tools. These include: FlexLogic : simplifies the programming and use of the B90 and enables powerful but flexible protection and control solutions FlexCurves : define additional custom curve shapes Typical Wiring The B90 is a multi-ed protection scheme. Each ED may be ordered with different hardware components and must be wired accordingly. The following drawing illustrates the principles behind a typical B90 wiring. A B C 5 GE Multilin B90 BUS DFFERENTL SYSTEM ED 1 ED 2 CURRENT NPUTS 8H 5 1 C C1 G5 G G1 5 5 1 C C1 F 1b F 1c F 2b F 2c F 3b F 3c F 4b F 4c F 5b F 5c F a F b F c F 7a F 7b F 7c CURRENT NPUTS 8H 5 5 1 C C1 G5 G G1 5 5 1 C F 1b F 1c F 2b F 2c F 3b F 3c F 4b F 4c F 5b F 5c F a F b F c F 7a F 7b CURRENT NPUTS 8H 5 5 1 C C1 G5 G G1 5 5 F 1b F 1c F 2b F 2c F 3b F 3c F 4b F 4c F 5b F 5c F a F b F1 GE Multilin B90 BUS DFFERENTL SYSTEM ED 4 DGTAL /O H F1 F2 F3 F4 F5 F CONTACT N F7a CONTACT N F7c CONTACT N F8a CONTACT N F8c COMMON F7b SURGE F1b F1c F2b F2c F3b F3c F4b F4c F5b F5c F a Fb Fc F7a F7c F8a F8c F7b F8b 83751 A2.CDR C1 F 7c 1 F c F 7a ED 3 C F 7b C1 F 7c 120

Multiple Settings Groups Six separate setting groups can be stored in the B90's non-volatile memory. An easy to use and fully programmable mechanism is provided to instantly switch the active settings. Multiple settings groups apply to all the protection elements. Communications The B90 supports a wide range of communication mediums and protocols to support new and existing communication infrastructures. Seamless, fast and secure inter-ed messaging with line, transformer, generator and other UR EDs, reduces wiring and increases flexibility for breaker failure initialization, tripping and other applications. Networking options include Ethernet-Fiber with optional redundancy and RS485 interfaces. With the advent of high-speed relay-to-relay communication LANs, performing inter-device control signaling via remote /O over the LAN can eliminate a great deal of inter-device control wiring. Protocols supported by the B90 include EC1850, DNP 3.0, Modbus RTU, Modbus TCP/P, and EC0870-5-104. These protocols make it easy to connect to a utility automation system and are integrated into the B90, removing the need for external protocol converter devices. nteroperability With Embedded EC 1850 Protocol EC 1850 is the new international standard for information exchange and interoperability between intelligent devices within a substation. Use the B90 with EC 1850 to lower the costs and simplify the engineering, commissioning, operating, and maintenance associated with substation protection and control applications. EC 1850 is built on over 7 years of GE leadership in UCA 2.0 implementation. EC 1850 allows for the seamless connection of EDs from multiple vendors. n addition to device interoperability, these protocols are designed to control the substation via a LAN instead of through discrete wiring to an RTU. Peer-to-peer communication over Ethernet enables distributed control with several EDs and eliminates the need for an RTU to remote SCADA master. High-speed message transfer eliminates the need for large and costly hard-wired interconnection. Direct /O Messaging This feature allows for the exchange of binary information between a number of UR EDs over a dedicated fiber (single or multimode), RS422, G.703 or C37.94 interface. No switching equipment is required as the EDs are connected directly in a ring or redundant (dual) ring configuration. Enerista The Enerista Suite is an industry leading set of software programs that will simplify every aspect of using the B90 relay. Tools to instantly monitor the status of the busbar and view the magnitude of any power quantities measured by the B90 relay are available. Also, the ability to analyze the cause of any faults using the powerful COMTRADE and the Sequence of Event viewers in the Enerista UR Setup program is included with each relay. Enerista LaunchPad Enerista LaunchPad is a powerful software package that provides users with all of the setup and support tools needed for configuring and maintaining all GE Multilin products. Also included is a document archiving system that will ensure that all manuals, application notes, and other necessary documentation are always up-todate and available when needed. iewpoint Monitoring iewpoint Monitoring is a software application that will provide Monitoring, Control, Trending, Alarming and Fault Data Recording functionality needed for substation applications. This easy to use program can be configured to give complete visibility, control, and automated retrieving and archiving of all Event Records and Waveforms files from GE Multilin devices in minutes. iewpoint Maintenance iewpoint Maintenance is a set of tools designed specifically for individuals responsible for diagnosing faults, maintaining and troubleshooting GE Multilin devices after commissioning. With a single click of the mouse, this software provides users with a simplified report that shows the cause of any power system faults or problems. This software will also enhance the security of the relay by providing reports that will document any changes have been made to the configuration of the devices. iewpoint Engineer iewpoint Engineer is a set of tools that will reduce the amount of time required to program, test and commission UR relays. The Graphical FlexLogic Editor will improve efficiency in programming UR's by combining the creating of control diagrams, documenting of logic, and programming of relays into one easy step. The Real-Time FlexLogic Analyzer will then simply commissioning and troubleshooting by displaying the status of each part of the equations as they change state. Enerista ntegrator Enerista ntegrator is the tool to use to send data that is measured by GE Multilin devices to new or existing HM, SCADA, or DCS system. This software can greatly reduce the time required to integrate GE Multilin devices with the Energy Management or Plant Operations Systems. Also included is a tool that will detect any new Events or Waveform files created by all the relays and automatically save them into a permanent historical archive, which will give a station wide Sequence of Event record. B90 Guideform Specifications For an electronic version of the B90 guideform specifications, please visit: /specs, fax your request to 905-201-2098 or email to literature.multilin@ge.com. 121

B90 Bus Differential System Ordering B90 - * ** - H * * - F**- H**- L**- N**- S**- U**- W** For Full Sized Horizontal Mount Base Unit B90 Base Unit CPU E RS485 + RS485 G RS485 + 10BaseF H RS485 + Redundant 10BaseF Software Options 0* Without Breaker Failure 1* With Breaker Failure (With Engineered Solution Only) *0 8-feeders, 4 1-phase zones *1 1-feeders, 4 1-phase zones *2 24-feeders, 4 1-phase zones *4 8-feeders, 4 1-phase zones, EC1850 *5 1-feeders, 4 1-phase zones, EC1850 * 24-feeders, 4 1-phase zones, EC1850 Mount H Horizontal (19" rack) User nterface C English P English with additional 4 small and 12 large programmable pushbuttons A Chinese B Chinese with additional 4 small and 12 large programmable pushbuttons D French G French with additional 4 small and 12 large programmable pushbuttons R Russian S Russian with additional 4 small and 12 large programmable pushbuttons Power Supply H 125 / 250 AC/DC L 24-48 (DC only) CT/T DSP 8F 8F 8F Standard 4CT/4T 8H 8H 8H Standard 8CT 8K 8K 8K Standard 7CT/1T Digital /O XX XX XX XX XX No module 4A 4A 4A 4A 4A 4A 4 Solid State (No Monitoring) MOSFET Outputs 4B 4B 4B 4B 4B 4B 4 Solid State (oltage w/opt Current) MOSFET Outputs 4C 4C 4C 4C 4C 4C 4 Solid State (Current w/opt oltage) MOSFET Outputs 4L 4L 4L 4L 4L 4L 14 Form-A (No Monitoring) Latchable Outputs 7 7 7 7 7 7 8 Form-A (No Monitoring) Outputs A A A A A A 2 Form-A (oltage w/ opt Current) & 2 Form-C Outputs, 8 Digital nputs B B B B B B 2 Form-A (oltage w/ opt Current) & 4 Form-C Outputs, 4 Digital nputs C C C C C C 8 Form-C Outputs D D D D D D 1 Digital nputs E E E E E E 4 Form-C Outputs, 8 Digital nputs F F F F F F 8 Fast Form-C Outputs G G G G G G 4 Form-A (oltage w/ opt Current) Outputs, 8 Digital nputs H H H H H H Form-A (oltage w/ opt Current) Outputs, 4 Digital nputs K K K K K K 4 Form-C & 4 Fast Form-C Outputs L L L L L L 2 Form-A (Current w/ opt oltage) & 2 Form-C Outputs, 8 Digital nputs M M M M M M 2 Form-A (Current w/ opt oltage) & 4 Form-C Outputs, 4 Digital nputs N N N N N N 4 Form-A (Current w/ opt oltage) Outputs, 8 Digital nputs P P P P P P Form-A (Current w/ opt oltage) Outputs, 4 Digital nputs R R R R R R 2 Form-A (No Monitoring) & 2 Form-C Outputs, 8 Digital nputs S S S S S S 2 Form-A (No Monitoring) & 4 Form-C Outputs, 4 Digital nputs T T T T T T 4 Form-A (No Monitoring) Outputs, 8 Digital nputs U U U U U U Form-A (No Monitoring) Outputs, 4 Digital nputs Transducer /O 5A 5A 5A 5A 5A 5A 4 dcma nputs, 4 dcma Outputs (select a maximum of 3) 5C 5C 5C 5C 5C 5C 8 RTD nputs 5D 5D 5D 5D 5D 5D 4 RTD nputs, 4 dcma Outputs 5E 5E 5E 5E 5E 5E 4 dcma nputs, 4 RTD nputs 5F 5F 5F 5F 5F 5F 8 dcma nputs nter-relay Communications 2A C37.94SM, 1300nm single-mode, ELED, 1 channel single-mode (use U slot if redundant 2B C37.94SM, 1300nm single-mode, ELED, 2 channel single-mode power supply option is chosen) 7A 820 nm, multi-mode, LED, 1 Channel 7B 1300 nm, multi-mode, LED, 1 Channel 7C 1300 nm, single-mode, ELED, 1 Channel Ordering Note: This order code is valid for the latest version of UR hardware 7D 1300 nm, single-mode, LASER, 1 Channel and firmware version 4.0 and later. The older hardware and previous 7H 820 nm, multi-mode, LED, 2 Channels firmware versions are still available and may be ordered through the usual 7 1300 nm, multi-mode, LED, 2 Channels channels. n addition, upgrade kits are available for users who wish to take 7J 1300 nm, single-mode, ELED, 2 Channels advantage of the features in the newer models. 7K 1300 nm, single-mode, LASER, 2 Channels Please see the GE Multilin On-Line Store (/onlinestore) 7M Channel 1 - RS422; Channel 2-1300 nm, multi-mode, LED 7R G.703, 1 Channel for the most up to date ordering information. 7S G.703, 2 Channels 7T RS422, 1 Channel Protocol Note: EC 1850 replaces UCA 2.0 as of UR firmware version 4.4. 7W RS422, 2 Channels For applications requiring the original UCA 2.0 protocol, please specify the 73 1550 nm, single-mode, LASER, 2 Channels pre-v4.4 UR firmware version at the time of ordering. 75 Channel 1 - G.703; Channel 2-1550nm, Single-mode LASER 7 EEE C37.94, 820 nm, multimode, LED, 1 Channel 77 EEE C37.94, 820 nm, multimode, LED, 2 Channel Accessories: nteractive UR Training CD-ROM available. isit / trainingcd to order. Engineered B90 solutions available: Please contact GE Multilin for more details. Accessorize your B90 122