Translational Computed Tomography: A New Data Acquisition Scheme

Similar documents
Comparison of Probing Error in Dimensional Measurement by Means of 3D Computed Tomography with Circular and Helical Sampling

An Acquisition Geometry-Independent Calibration Tool for Industrial Computed Tomography

2D Fan Beam Reconstruction 3D Cone Beam Reconstruction

Advanced Reconstruction Techniques Applied to an On-Site CT System

Quality control phantoms and protocol for a tomography system

DEVELOPMENT OF CONE BEAM TOMOGRAPHIC RECONSTRUCTION SOFTWARE MODULE

Discrete Estimation of Data Completeness for 3D Scan Trajectories with Detector Offset

High-resolution X-ray CT Inspection of Honeycomb Composites Using Planar Computed Tomography Technology

Scaling Calibration in the ATRACT Algorithm

AUTOMATED HIGH SPEED VOLUME COMPUTED TOMOGRAPHY FOR INLINE QUALITY CONTROL

Improvement of Efficiency and Flexibility in Multi-slice Helical CT

Adapted acquisition trajectory and iterative reconstruction for few-views CT inspection

HIGH-SPEED THEE-DIMENSIONAL TOMOGRAPHIC IMAGING OF FRAGMENTS AND PRECISE STATISTICS FROM AN AUTOMATED ANALYSIS

Non-Stationary CT Image Noise Spectrum Analysis

Top-level Design and Pilot Analysis of Low-end CT Scanners Based on Linear Scanning for Developing Countries

Multi-slice CT Image Reconstruction Jiang Hsieh, Ph.D.

Fiber Composite Material Analysis in Aerospace Using CT Data

Digital Laminography and Computed Tomography with 600 kv for Aerospace Applications

Reconstruction Methods for Coplanar Translational Laminography Applications

CT Reconstruction with Good-Orientation and Layer Separation for Multilayer Objects

TESTING OF THE CIRCLE AND LINE ALGORITHM IN THE SETTING OF MICRO-CT

Towards full-body X-ray images

Registration concepts for the just-in-time artefact correction by means of virtual computed tomography

Suitability of a new alignment correction method for industrial CT

APPLICATION OF RADON TRANSFORM IN CT IMAGE MATCHING Yufang Cai, Kuan Shen, Jue Wang ICT Research Center of Chongqing University, Chongqing, P.R.

3D X-ray Laminography with CMOS Image Sensor Using a Projection Method for Reconstruction of Arbitrary Cross-sectional Images

17th World Conference on Nondestructive Testing, Oct 2008, Shanghai, China

VJ Technologies Inspection Services Division. By Bob Maziuk, February 2015

3D Computed Tomography (CT) Its Application to Aerospace Industry

Spiral ASSR Std p = 1.0. Spiral EPBP Std. 256 slices (0/300) Kachelrieß et al., Med. Phys. 31(6): , 2004

Advanced Image Reconstruction Methods for Photoacoustic Tomography

Continuous and Discrete Image Reconstruction

Methods for Quantitative Characterization of Large-Scale High Energy Computed Tomography Systems

MEDICAL IMAGING 2nd Part Computed Tomography

Comparison of Reconstruction Methods for Computed Tomography with Industrial Robots using Automatic Object Position Recognition

Ultrasonic Multi-Skip Tomography for Pipe Inspection

HIGH RESOLUTION COMPUTED TOMOGRAPHY FOR METROLOGY

GE s Revolution CT MATLAB III: CT. Kathleen Chen March 20, 2018

Tomographic Reconstruction

Identification of Shielding Material Configurations Using NMIS Imaging

Radiology. Marta Anguiano Millán. Departamento de Física Atómica, Molecular y Nuclear Facultad de Ciencias. Universidad de Granada

Reconstruction from Projections

Generalized Filtered Backprojection for Digital Breast Tomosynthesis Reconstruction

Physics 102: Lecture 17 Reflection and Refraction of Light

Combining Analytical and Monte Carlo Modelling for Industrial Radiology

2D Fan Beam Reconstruction 3D Cone Beam Reconstruction. Mario Koerner

Central Slice Theorem

Non-Destructive Failure Analysis and Measurement for Molded Devices and Complex Assemblies with X-ray CT and 3D Image Processing Techniques

Frequency-based method to optimize the number of projections for industrial computed tomography

INDUSTRIAL SYSTEM DEVELOPMENT FOR VOLUMETRIC INTEGRITY

Lab 10 - GEOMETRICAL OPTICS

Lab 9 - Geometrical Optics

Recognition and Measurement of Small Defects in ICT Testing

Coordinate Measuring Machines with Computed Tomography

MULTI-PURPOSE 3D COMPUTED TOMOGRAPHY SYSTEM

Advanced Computed Tomography System for the Inspection of Large Aluminium Car Bodies

Implementation of a backprojection algorithm on CELL

Digital Image Processing

Robot-based real-time ultrasonic tomography for industrial NDT applications

Emission Computed Tomography Notes

SPECT reconstruction

Material for Chapter 6: Basic Principles of Tomography M I A Integral Equations in Visual Computing Material

USING cone-beam geometry with pinhole collimation,

Strategy. Using Strategy 1

Three-Dimensional Laser Scanner. Field Evaluation Specifications

Algebraic Iterative Methods for Computed Tomography

Medical Image Reconstruction Term II 2012 Topic 6: Tomography

Optimal threshold selection for tomogram segmentation by reprojection of the reconstructed image

2. Equipment, specimens and inspection procedures

Novel evaluation method of low contrast resolution performance of dimensional X-ray CT

CIVA Computed Tomography Modeling

DUE to beam polychromacity in CT and the energy dependence

ULTRASONIC TESTING AND FLAW CHARACTERIZATION. Alex KARPELSON Kinectrics Inc., Toronto, Canada

Scatter Correction Methods in Dimensional CT

Light, Photons, and MRI

Cover Page. The handle holds various files of this Leiden University dissertation

TEAMS National Competition Middle School Version Photometry Solution Manual 25 Questions

AUTOMATED 4 AXIS ADAYfIVE SCANNING WITH THE DIGIBOTICS LASER DIGITIZER

The Role of Linear Algebra in Computed Tomography

Process Monitoring using Three Dimensional Computed Tomography and Automatic Image Processing

Tomographic X-ray data of a walnut

Physical Optics FOREWORD

Selective Space Structures Manual

A Projection Access Scheme for Iterative Reconstruction Based on the Golden Section

Industrial Computed Tomography Innovations

18th World Conference on Nondestructive Testing, April 2012, Durban, South Africa

Chapter 12 Notes: Optics

Light: Geometric Optics

Wieblinger Weg 92a, Heidelberg, Germany, Phone: , Fax: ;

Iterative and analytical reconstruction algorithms for varying-focal-length cone-beam

DD2429 Computational Photography :00-19:00

Process Monitoring using three dimensional Computed Tomography and Automatic Image Processing

X-ray Industrial Computed Laminography (ICL) Simulation Study of Planar Objects: Optimization of Laminographic Angle

Building Reliable 2D Maps from 3D Features

XRADIA microxct Manual

The PolyCT Increasing the sample throughput using multiple rotation axes

Enhancement Image Quality of CT Using Single Slice Spiral Technique

2-D Reconstruction Hannes Hofmann. 2-D Reconstruction. MB-JASS 2006, March 2006

Investigating the influence of workpiece placement on the uncertainty of measurements in industrial computed tomography

X-ray tomography. X-ray tomography. Applications in Science. X-Rays. Notes. Notes. Notes. Notes

Transcription:

2nd International Symposium on NDT in Aerospace 2010 - We.1.A.3 Translational Computed Tomography: A New Data Acquisition Scheme Theobald FUCHS 1, Tobias SCHÖN 2, Randolf HANKE 3 1 Fraunhofer Development Center X-ray Technology A Cooperative Department of IIS Erlangen and IZFP Saarbrücken Dr.-Mack-Straße 81, 90762 Fürth, Germany 2 Fraunhofer Institute for Integrated Circuits IIS, Department Process Integrated Inspection Systems Am Wolfsmantel 33, 91058 Erlangen 3 Julius-Maximilians-University Würzburg Faculty for Physics and Astronomy Chair for Materialcharacterization by X-ray Microscopy Am Hubland, 97074 Würzburg Abstract. Today, most computed tomography (CT) systems acquire projection data from several hundred to thousands of directions by employing multi-row (2-D) or flat-panel detectors (cone-beam for 3-D imaging). It is important to notice the following fact: modern CT systems all rely on a rotational movement. The most widely utilized reconstruction algorithms, as for instance the well-known Feldkamp method, are based on filtered back projection (FBP). These algorithms afford a series of projection images covering an angular range of at least 180. 1. Introduction Today, X-ray Computed Tomography (CT) is widely used in non-medical applications, e.g. for industrial non-destructive testing (NDT) or as a tool in research and development laboratories [1, 2]. Although, various CT data acquisition methods have been developed to meet the different applications, today, all systems are based on a rotation of the object. Alternatively, this can be achieved by rotating the detector and the source of x-rays around the object, but mathematically both methods are equivalent. Licence: http://creativecommons.org/licenses/by-nd/3.0 1

detector parallel X-rays y 180 rotation θ object x translation source Figure 1: Scheme of the classical parallel beam geometry. The conventional data acquisition for CT imaging requires transmission measurements from at least 180 view angle. In industrial non-destructive testing, usually the X-ray source and the respective detector are fixed and the object is rotated mechanically in-between. The CT principle is shown in fig. 1 by its most simple realization, the classical translations-rotational data acquisition scheme. In order to increase the scan speed, today most systems use a fan-beam-type or even cone-beam geometry, and acquire more than one slice during a single rotation by employing multi-row or flat-panel detectors (for a comprehensive introduction into Computed Tomography in general, see e.g. [3]). A well-known alternative to physically truthful 3-D image reconstruction is a technique called digital Tomosynthesis which requires a co-planar movement of X-ray source and detector on each side of the object. While the number of acquired images as well as the view angles are limited and minimized for data acquisition during a Tomosynthesis measurement (in comparison to the rotational 3-D CT), the resulting image quality is accordingly worse, and most often, Tomosynthesis is not an equivalent substitute for a fully 3-D CT. Nevertheless, in reality there are numerous objects which are desirable to be inspected by X-ray CT but do not allow for a rotational movement, like e.g. very heavy objects which cannot be accessed from all directions. For instance, such an object could be a pipe, positioned in the corner of a building (fig. 2) or a cable channel located inside a wall. 2

tube wall region of interest duct walls gap Figure 2 - left hand side: A pipe located in the corner of a room. This object is inaccessible to the conventional 180 view angle data acquisition by rotating an X-ray source and a detector. If there is enough space left between the pipe and the wall to insert a thin linear detector array or a flat panel detector, a Translational CT data acquisition as proposed in this contribution, is feasible. Right hand side: The virtual cross-section examined in the simulation study. The grey circles indicate smaller pipes within a large tube, the green dots mark cables. Several internal details like cracks, bore holes or missing wires are included. 2. Material and Method Within this contribution, we propose a new data acquisition method called Translational CT [4]. The new technique is based on a linear, translational-only movement of the X-ray source (fig. 3). Given a certain distance of the source x S to the object, each detector position y defines a different ray angle θ with respect to the object. This allows for acquiring a set of various view angles. Or, seen from a single detector position, each source distance corresponds to another projection. After recording transmission images for a manifold of different source-to-object distances the single data sets are merged by sorting the rays according to their angular orientation. Thereby, the t-coordinate describes the shortest distance of the X-ray to the center of the field of measurement (FoM). The new method is derived from the observation that both, the direction (the angle) and the shortest distance of each ray with respect to the object changes, if the distance between the X-ray source and the detector is modified. In other words: the rotational movement is substituted by one or more linear movements of the X-ray source towards the object to be inspected. The new translational data acquisition scheme is mathematically described in a 2-D plane by the following two equations: First, there is a relation between the ray angle θ, the source position x S and the associated detector channel y: y tanθ =. x R S + 2 M Secondly, the distance t is given as a function of the ray angle and the source position. θ ( x ) = x sinθ + R ( sinθ cosθ ) t. S S M 3

Each single ray is defined by the two parameters, t and θ. Using the two equations, the region within the complete parameter space, which is covered by the translational movement, can be determined. source x θ t x S 2R M detector Figure 3: Scheme for data acquisition with linear translation of the source only. The operating expense is much less compared to a rotational set-up. The detector (green vertical line) is fixed behind the object. The blue circle (radius R M ) indicates the field of measurement (FoM), which encloses the cross-section of any object therein. As can be seen from the red arrows, the angle of the rays travelling through the object changes as the tube is moved towards or away from the object. y The ray hitting the detector s surface at exactly 90 is referred as the central ray of the X-ray source (hereby the x-direction is defined). The angle of the central ray with respect to the fixed object does not change while the source is translated, thus no additional information is acquired. Deliberately, the central ray is shifted to the edge of the FoM. In consequence, the regions next to the central ray are expected to yield the poorest image quality. Further, it is obvious, that the angular range of rays which can be achieved by translational-only movement is restricted to less than 90 in the limit of an infinitely long detector and the source positioned adjacent to the object (x S = 0). Fig. 4. demonstrates this matter of fact. 4

+1 t R M Increasing source distance 0 Single source position θ π 0,25 0,5 0,75 1,0 1 Figure 4: θ - t -diagram demonstrating the part of the full data range necessary for reconstruction of single slice (sinogram). For each angle between 0 and 180 the distance of the ray to the center of the field of measurement should vary between -1 and +1. With a single translation, a limited part of the 180 -sinogram is filled. Principally, a single Translation cannot deliver all angular directions within 180 In order to overcome this intrinsic weakness of the translational approach, we implemented an extended data acquisition scheme employing two translations (fig. 5). source S 1 detector 2 y 2 = x 1 detector 1 source S 2 y = 1 x 2 Figure 5: A straight forward extension of the translational method. The translational movement is applied twice with 90 angular offset. The second translation yields data in the gap for view angles between 90 and 180. Virtual data were generated for a phantom which resembles a pipe with several details inside, e.g. smaller pipes or cables (fig. 2). During each linear translation of the X-ray source, 200 positions were sampled, with 0.1 spacing relative to the radius of the FoM which is taken as unit: R M = 1. Thus, the source-to-object distance varied between 0 and 19.9, which is equivalent to approximately 10 times the diameter of the object. The virtual detector was simulated with 512 pixel and 0.01 pixel-to-pixel increment. Thus, the linear dimension of the detector is equivalent to approximately 2.5 times the object s diameter. In 5

the case of two linear movements (fig. 4), both were simulated with identical parameters, as described above. For comparison, a complete set of data were simulated in parallel beam geometry (fig. 1). Explicitly, for each of 200 angular positions within 180 range the FoM (diameter 2 in arbitrary units) the attenuation profile was sampled by 256 parallel rays with a distance of 0.01. The reconstruction was carried out with a complete 180 data set, as well as with reduced angular ranges of 120 and 90 degree in order to compare the degradation of image quality with the respective results for the translational technique. For image reconstruction a state-of-the art ART (algebraic reconstruction technique) algorithm was used throughout the whole study [5]. From fig. 4 it is obvious, that a straight forward filtered backprojection approach would only lead to inferior image quality due to the intrinsic incompleteness of the projection data. All images have 256 by 256 pixels with 0.01 by 0.01 pixel size relative to the FoM. 3. Results Fig. 6 shows the reconstruction from a conventional rotation-based data acquisition in parallel beam geometry. The image quality for the complete angular range of 180 is perfect, while rapidly degrading when the range is reduced to 120 and 90. The angular range utilized can be directly seen from the contour of the wall of the outermost tube. Figure 6: Reconstructions from parallel beam data with an angular range of 180, 120 and 90 degrees, respectively (from left to right). All images were reconstructed with an algebraic reconstruction technique ART. Fig. 7 shows the respective results of the Translational CT technique with one translation only respectively two translations with 90 angular offset. 6

Figure 7: Reconstructions from translational data acquired during one translation (0, left hand side) and during two translations in orthogonal directions (0 and 90, right hand side) Obviously, the image quality obtained by a single translation is not sufficient (fig. 7, left hand side). By adding a second translation, with the direction of source movement shifted by 90, the image quality improved significantly (fig. 7, right hand side). As predicted, the least information can be derived along the central rays (upper left corner). Apart from this, the simulated bundles of four by four cables are depicted clearly (left side), as well as the larger tubes including the slits and holes (bottom right). At this point, it is necessary to emphasize that the same standard ART reconstruction was applied to all data-sets. Yet there has not been made any adaption or optimization for the translational case. Nevertheless, the results achieved with two translations are already comparable to a rotation about 90 angular range, which is equivalent to 100 projections according to the parameters used in this study. 4. Summary and Outlook We have shown by simulations that imaging of cross-sections based on CT reconstruction is feasible with a translation type movement of the X-ray source only. Without rotation of the object or the equipment we were able to depict the details within most parts of the section of a large pipe. It has to be noted that the details in the object under examination are characterized by a high contrast with respect to the background. A quantitative interpretation of the reconstructed pixels is still a little bit more difficult. The simple way of data acquisition, proposed in this paper, should enable 2-D and 3- D imaging of those objects, which are commonly thought as not accessible to CT measurements, e.g. pipes in a close distance to other objects or the structure inside of walls or large machinery. An extension to a 3-D Translational CT imaging by making use of 2-D flat panel detectors goes without saying. Of course, our new technique can be used in all cases, including those, where the object is accessible from all sides, but a rotational mechanical set-up is difficult to achieve, e.g. for on-the-field measurements of pipelines, power generators, cable channels or electrical equipment. Since the translational set-up is simple and straight forward (cf. fig. 8), it 7

can be preferable to the mechanically more complex and expensive rotational set-up. One particularly promising application of the Translational CT is the 3-D inspection of freight containers, which are typically too large and too heavy to be rotated. 2 200 cm 20 cm Detector 1 Object 3 1 : translation of source - sampling of magnification 2 : rotation of whole set-up - two or three directions of view 3 : lateral translation of detector alignment Figure 8: Proposed set-up for a system realizing the Translations CT method. Adjustment of the set-up is simple and straight forward. Since the linearity of a typical translational axis (1) is highly accurate, the main issue is the alignment of the flat panel detector orthogonal to the direction of the source movement. Nevertheless, the image quality achieved by Translational CT method is worse compared to a complete parallel beam data set, measured during a 180 rotation of the object or the X-ray source and the detector, respectively. Future efforts will be made in improving the quality of the Translational CT reconstructions by exploring several ways: - taking into account a-priori knowledge about the object - applying non-equidistant sampling of the source positions - considering more sophisticated acquisition geometries, for instance three translations at 0, 45 and 90 (cf. fig. 9) - optimizing the translational scan parameters in general, i.e. necessary dimensions of the detector and the source travel distance 8

source S 45 inaccessible region region of interest detector Figure 9: Proposed set-up for a system realizing the Translations CT method. Further mathematical analysis of the translational data acquisition will help to optimize the scan parameters. Since the results of the simulation study are very encouraging, current efforts aims at a specification and realization of a prototype Translational CT system. Its novel capabilities will be explored in various applications, in particular in inspecting parts of an aircraft like the tail fin and the elevators which cannot be assessed by rotational CT data acquisition. In addition, application of the Translational CT for testing issues in the field of civil engineering is highly promising, too. References [1] T. Fuchs, T. Schön, R. Hanke, et al., Progress towards quantitative computed tomography as a tool for industrial inspection, European Conference on Materials and Structures in Aerospace 2008, 26 27 May 2008, VDI-Berichte 2028; pp. 425-430 [2] T. Fuchs and R. Hanke, Task-driven design of X-ray systems for industrial inspection, IEEE Nuclear Science Symposium and Medical Imaging Conference, NSS/MIC 2008, Dresden, Germany, 19-25 October 2008; pp. 523-527 [3] A.C. Kak and M. Slaney, Principles of Computerized Tomographic Imaging, IEEE Press, 1988 [4] European patent pending [5] G. Gordon, et al., Algebraic reconstruction techniques (ART) for three-dimensional electron microscopy and x-ray photography, J. Theoret. Biol. 29 (1970), pp. 471-481. 9