SIA-B. Overcurrent & Earth Fault Protection Relay for Secondary Distribution. Dual & Self Powered / Standard CTs. Main characteristics

Similar documents
SIL-A. Overcurrent and Earth Fault Relay for Primary and Secondary Distribution. Main characteristics

SIA-C. Overcurrent and Earth Fault Protection Relay for Secondary Distribution. Dual & Self Powered. Main characteristics

Function permission: yes/no. Operating range: 0.10 to 30 xin (step 0.01) Operating time: 0.02 to 300 s (step 0.01 s) Activation level 100%

INSTALLATION & COMMISIONING GUIDE

SIA/SIL. Secondary and Primary Distribution Protection Relays. Specialized in self powered relays IEC 61850

Protection relay for secondary distribution

SIA-C. Overcurrent and Earth Fault Protection Relay for Secondary Distribution. Dual & Self Powered. Main characteristics

SIA C. Self-powered overcurrent relay USER MANUAL

Index POWER T&D. SIA-B (Dual & Self powered) OC&EF Protection for Secondary Distribution with specific transformers... 20

GENERAL CATALOGUE. Equipments. Devices. fanox.com

U lity network. system Q sys. Interconnected P sys. P load Q load. P gen Q gen. Generator network

ISO 9001:2000 SIL A. Overcurrent and Earth-Fault relay USER S MANUAL SER S MANUAL

INTRODUCTION. The PL-50 MO and PM-250 families represent the. PM-250-H: Horizontal box. PM-250-V: Vertical box

SIA/SIL. Secondary and Primary Distribution Protection Relays. Specialized in self powered relays IEC 61850

SIL. Protection relays for primary and secondary distribution

ISO 9001:2000 SIL A. Overcurrent and Earth fault relay INSTALLATION GUIDE. Guia_SIL-A_Rev / 48

SIA B Self and Dual powered Overcurrent & Earth Fault Protection Relay USER S MANUAL L

ADDITIONAL INFORMATION MODBUS INSTRUCTION MANUAL. Request publication Request publication DNP 3.0 INSTRUCTION MANUAL

MiCOM P124 T&D. Self and Dual Powered Overcurrent Relays

Protection Relays PHASE & RESIDUAL OVERCURRENT

MiCOM P123R. Overcurrent Relays P123R/EN AD/A11. Upgrade Documentation

NPW800R RETROFITTING. Power and Volatge Protection Relay

Request publication Request publication DNP 3.0 INSTRUCTION MANUAL. Request publication

VIP 40/45 VIP 400/410

MiCOM P124. Self and Dual Powered Overcurrent Relays. Protection Relays

Bus Bar Protection Relay B-PRO 4000

SR489 SR489. Generator Management Relay. Economical protection, metering, and monitoring functions for small and medium sized generators.

GE Power Management. UR F60 Feeder Management Relay An integrated feeder protection and metering solution

Transformer Protection Relay

ATS Automatic transfer switches Advanced version

BF

GE Multilin 350 Feeder Protection Relay Specifications

REL52002 Easergy P3U30, 4L, 4U, 16DI/8DO, Uaux: V, DI: V, RS-485

7SR242 Duobias Multi-Function 2-Winding Transformer Protection Relay

02/11/2015

ADDITIONAL INFORMATION MODBUS INSTRUCTION MANUAL Request publication Request publication

SEL-487B. A Powerful Solution for Busbar Differential Protection. Bus Differential and Breaker Failure Relay

Advanced distribution feeder solution with integrated protection, monitoring, and control

METERING INSTRUMENTS AND CURRENT TRANSFORMERS

DIGITAL RELAY OF PROTECTION AND AUTOMATION SERIES PC83 AND PC830

7SR11 and 7SR12 Settings and Instruments

PROTECT Electronics Co. Ltd

EDR-3000 Eaton Distribution Relay

Remote communication options include IEC Ethernet communications or Modbus (RS485).

VAMP 11F. Overcurrent Protection Relays. Protection

BF 79 81

SYMAP R Plug in Variants FI, MI, 87M, TI Technical data

REL52001 Easergy P3U30, 4L, 4U, 16DI/8DO, Uaux: V, DI: V, 2 x RJ-45

BF Option. BESTNet BESTNet BESTNet BESTNet BESTNet BE1-700C DIGITAL OVERCURRENT PROTECTIVE RELAY ADVANTAGES

DGSZV-EP DIGITAL GALVANIC LONGITUDINAL DIFFERENTIAL PROTECTION. Application field

EDR-3000 Eaton Distribution Relay

GRE130. Protection and Control for MV Systems

MiCOM P111 Numerical three phase and earth fault overcurrent relay description

www. ElectricalPartManuals. com Protective Relays PROTECTION AND CONTROL FUNCTIONS ADVANCED CAPABILITIES

Maximize process uptime with the SEL-patented motor thermal model.

RTU560. CT/VT Interface 560CVT10. Meter Operation. Application. Characteristics. Data Sheet CT/VT Interface 560CVT10. Instantaneous Meter Values

100% electricity. Automatic transfer switch controllers ATL series

MiCOM P122C Time-Overcurrent Protection

NewCode. Comprehensive Motor Protection and Control Relay. Relay Field Input and Output LEDs. LED Fault Indicators

BE1-951 OVERCURRENT PROTECTION SYSTEM ADVANTAGES

F650 Firmware Release Notes / History (Rev 10)

Type MVTT 14 and MVTT 15: Static Digital Time delay relays

Combined Overcurrent and Earth-fault Relay SPAJ 140 C. Product Guide

SIPROTEC easy 7SJ45 Numerical Overcurrent Protection Relay Powered by CTs

GRE120. Motor Protection and Control for MV Systems

Overcurrent and Arc Protection by Reyrolle Alexander Erokhin. 21, 2017 I Berlin

FP-5000 Feeder Protection

MIN II. Complete numerical ground directional protection. Digital Energy Multilin. Protection and Control. Monitoring and Metering.

Product Sheet ECO. Types ECG, AMF Technical data. product sheet eco ecg-amf - technical data gb v1.0.docx

PM800 series. Applications

MPR-4 SERIES NETWORK ANALYSER USER MANUAL

FP-5000 Series Multi-functional Microprocessor-based Feeder Protective Relay

Type SDR reclosers plus controllers and type B-2 recloser bypass switch assembly usa.siemens.com/mediumvoltage

MIFII-N. GE Consumer & Industrial Multilin. Single Phase Digital Feeder Protection with Recloser Instruction manual GEK C

GRD130 - FEATURES APPLICATION

Relion 605 series. Self-powered feeder protection REJ603 Product Guide

Section 4 Ground-Fault Protection Devices

AUGUST 2001 APPLICATION AND COMMISSIONING MANUAL MIT161 RELAY EASUN REYROLLE LIMITED

Products Portfolio. Pole mounted Vacuum Recloser

MiCOM P521. Fast feeder differential protection

NPI800 NPI800R. First Handling Guide. Phase and earth overcurrent relay

SDR recloser. A PH Fault B PH Fault C PH Fault. Ground Fault. SGF Lockout Aux Power OK. Recloser OK

TECHNICAL DATA SHEET. ProVU 4 Advanced Temperature Controller. Features. Description

Iso DIN. User Manual. 1 channel Earth Fault Monitoring

MULTIFUNCTION MICROPROCESSOR PROTECTION RELAY TYPE IM30-G DATA BASE

A low-cost, economical solution for distribution feeder protection

Relion 615 series Line Differential Protection and Control RED615 Ver. 2.0 Technical Presentation

Technical Specificaions. kwh Energy Meter

VAMP 11V. Voltage and Frequency Protection Relays. Protection

Earth-fault Relay SPAJ 110 C. Product Guide

RELAYABLE POWER. AQ 200 series protection, control, measurement and monitoring IEDs

MiCOM P12x/y AREVA T&D. Three phase and earth fault overcurrent relays

MiCOM P111. Three phase and earth fault overcurrent relays

Feeder Protection Relay REF 610. Product Guide

TFS 2100 Traveling Wave Fault Location System

www. ElectricalPartManuals. com Protective Relays HIGHLIGHTS PROTECTIVE FUNCTIONS ixp-420 Transformer Protection Relay

Relion 615 series Transformer Protection and Control RET615 Ver. 2.0 Technical Presentation

Three phase and earth fault overcurrent relays

Residual overvoltage relay

SACE Emax 2 Specification guide

Transcription:

SIA-B Overcurrent & Earth Fault Protection Relay for Secondary Distribution Dual & Self Powered / Standard CTs Main characteristics The SIA-B is an protection relay with self powered and dual powered (Self-powering + Auxiliary power) options. The relay is self powered using the operating current through three /1 (<2VA) standard current transformers fitted on the lines. These transformers are also used to obtain current measurements. Besides, SIA-B relay can be used with auxiliary power supply (24-230 Vac/dc). The relay can be also supplied by a USB cable connected to the laptop, with the USB KITCOM adapter or an standard power bank. Multiple options for powering and communication Internal commissioning battery included. 50_1, 50/51, 50G_1, 50/51G, 49, SHB, PGC protection functions. Micro USB front port connection (Modbus RTU protocol) for local communication. Remote communication through rear RS485 port (Modbus RTU or DNP 3.0 selectable by general setting) as optional. 49T function available through configurable inputs. 52 function to control the state of the circuit breaker. 50_2, 50G_2, CLP, 46, 50BF and trip block for switch disconnector as optional. Specific test menu is provided. High electromagnetic compatibility. ProtecTions 50 Instantaneous Phase 50/51 Inverse time phase 50G Instantaneous Neutral 50/51G Inverse time neutral 46 Negative Sequence instant. 49 Thermal image CLP Cold Load Pick-up SHB Second Harmonic Blocking 50BF Circuit Breaker opening failure 52 Circuit Breaker monitoring 49T External trip TB Trip Block protection The installation and subsequent maintenance of external batteries is eliminated. The operating costs of the centre are reduced. Really low start-up levels: 75 ma in three phase system /160 ma in single phase system. The line opening mechanism is activated by means of a striker PRT, operated by the energy supplied by the relay. There are 4 configurable LEDs. When the relay is switched off, their previous states can be checked by powering the relay up (by self-powering the relay, through USB cable, auxiliary voltage or pressing commissioning battery). The SIA-B is fitted with the demand of current (load data profiling) with the following characteristics: Number of records: 168 Recording mode circular Sampling rate (interval): configurable through communications: 1 60 min. Non-volatile RAM memory in order to store up to 1.024 events, disturbance fault recording (DFR- 20 fault reports and 10 oscillographic records in COMTRADE format), maintaining date & time thanks to its internal RTC (Real Time Clock) even without power supply. 26

Technical specifications SIA-B Functions diagram SIA-B Battery 5Vdc Tx Rx Events 50 SHB 50* 46* 50/51 49 CLP* RTC (1 ms) DFR Setting table 50G 50G* 50/51G Power Demand Leds config. PGC TB* 52 50BF* 49T* Vaux* RTC Trip RS485* Out config. Input config. Test Hmi LCD 20x2 7 keys * optional * Available through configurable inputs 3 CT power supply-measurement Rigid neutral Connections diagram SIA-B 27

Technical specifications SIA-B Excessive repeated openings: Technical parameters SIA-B Function 50_1 Function 50_2 (*) Function 50G_1 Function 50G_2 (*) Function 50/51 Function 50/51G Operating range: 0.10 to 20 x In (step 0.01 x In) Operating time: 0.02 to 300 s (step 0.01 s) Activation level 100% Deactivation level 95% Without SHB permitted: ± 30 ms or ± 0.5% (greater of With SHB permitted: ± 50 ms or ± 0.5% (greater of Operating range: 0.10 to 10 x In (step 0.01 x In) Operating time: 0.02 to 300 s (step 0.01 s) Activation level 100% Deactivation level 95% Without SHB permitted: ± 30 ms or ± 0.5% (greater of With SHB permitted: ± 50 ms or ± 0.5% (greater of Operating range: 0.10 to 7 x In (step 0.01 x In) Curves: IEC 60255-151 and IEEE Operating time: IEC Inverse curve, IEC very inverse curve, IEC extremely inverse curve, IEC long time inverse, IEEE Inverse curve, IEEE very inverse curve, IEEE extremely inverse curve. Defined time: 0.02 to 300 s (step 0.01 s) Dial (TMS): 0.01 to 1.5 (step 0.01) Curve, activation level 110% Curve, deactivation level 100% Defined time, activation level 100% Defined time, deactivation level 95% Without SHB permitted: ± 30 ms or ± 5% (greater of With SHB permitted: ± 50 ms or ± 5% (greater of Operating range: 0.05 to 7 x In (step 0.01 x In) Curves: IEC 60255-151 and IEEE Operating time: IEC Inverse curve, IEC very inverse curve, IEC extremely inverse curve, IEC long time inverse, IEEE Inverse curve, IEEE very inverse curve, IEEE extremely inverse curve. Defined time: 0.02 to 300 s (step 0.01 s) Dial (TMS): 0.01 to 1.5 (step 0.01) Curve, activation level 110% Curve, deactivation level 100% Defined time, activation level 100% Defined time, deactivation level 95% Without SHB permitted: ± 30 ms or ± 5% (greater of With SHB permitted: ± 50 ms or ± 5% (greater of Function 49 Function SHB Function 52 Function CLP (*) Function 46 (*) Function 49T Function TRIP BLOCK (*) Function 50BF (*) Programmable logic control (PGC) Settings tables Events Disturbance Fault Recording (DFR) Function Enable: yes/no Tap: 0.10 to 2.40 xin (step 0.01) ζ heating: 3 to 600 minutes (step 1 min) ζ cooling: 1 to 6 x ζ heating (step 1) Alarm level: 20 to 99% (step 1 %) Trip level: 100% Trip reset: 95% of alarm level ± 5% regarding theoretical value Function Enable: Yes/No Current Tap: 5% to 50% (step 1%) Reset Time: 0.00 to 300 s (step 0.02 s) Maximum number of openings: 1 to 10000 (step 1) Maximum accumulated amps: 0 to 100000 (M(A²)) (step 1) Opening time: 0.02 to 30 s (step 0.01 s) Closing time: 0.02 to 30 s (step 0.01 s) Excessive repeated openings: 1 to 10000 (step 1) Repetitive openings/time: 1 to 300 min (step 1 min) Function Enable: Yes/No Settings group: 1 to 4 (step 1) No load time: 0.02 to 300 s (step 0.01 s) Cold Load Time: 0.02 to 300 s (step 0.01 s) CLP activation threshold: 60 ma CLP reset threshold: 80 ma Function Enable: Yes/No Operating range: 0.10 to 7.00 xin (step 0.01) Curves IEC 60255-151 and IEEE Operating time: IEC Inverse curve, IEC very inverse curve, IEC extremely inverse curve IEC long time inverse, IEEE Inverse curve, IEEE very inverse curve, IEEE extremely inverse curve. Defined time : 0.02 to 300 s (step 0.01 s) Dial (TMS): 0.01 to 1.5 (step 0.01) Curve, activation level 110% Curve, deactivation level 100% Defined time, activation level 100% Defined time, deactivation level 95% Available through configurable inputs Blocking: Yes/No Blocking limit: 1.5 to 20 x In (step 0.01) Function Enable: yes/no Opening fault time: 0.02 to 1.00 s (step 0.01 s) Open circuit breaker activation threshold: 60 ma Function Pickup configurable: Equipment trip, activation of the opening fault input, circuit breaker open control activation. OR4, OR4_LATCH, OR4_PULSES, OR4_TIMERUP, OR4_PULSE, NOR4, NOR4_TIMERUP, NOR4_PULSE, NOR4_PULSES, AND4, AND4_LATCH, AND4_PULSES, AND4_TIMERUP, AND4_PULSE, NAND4, NAND4_ TIMERUP, NAND4_PULSE. 4 settings tables: Activated by inputs or by general settings 1024 events (*) Optional depending on model 20 fault reports, 16 events in each 10 Oscillographic records (50 cycles each) 28

Technical parameters SIA-B Demand of current with the following characteristics: Number of records: 168 Recording mode circular Sampling rate (interval): configurable through communications: 1 60 min Record format: Load Data Profiling (Current Date/Time Demand) IMAX (in interval) IMAX (actual) IA IB IC IN Trip output For Striker: 24 Vdc-135 mj 3 changeover outputs (output 1, output 2 and output 3): Signaling outputs 250 Vac 8 A 220 Vdc 8 A 3 inputs: They are activated by short-circuiting the Signaling inputs terminals without external supply Frequency 50/60Hz Fundamental values (DFT) Current Sampling: 16 samples/cycle measurement Accuracy of ±2% on a band of ±20% over the nominal current and ±4% or ± 5mA (greater of both) over the rest of the range. Micro USB front port: Modbus RTU Communication RS485 port: Modbus RTU or DNP3.0 Serial (*) Power supply 24-230 Vac/dc +10 % / 20% With USB KITCOM adapter or standard power bank Battery supply Internal commissioning battery Self-power from Three phase self-power level: current I > 75mA Operating temperature: -40 to 70ºC Environment Storage temperature: -40 to 80 ºC Humidity: 95% Transformers Power supply and measurement CT /1 Metallic box Panel Mounting Mechanical Height x Width: 90 x 245 (mm) features Depth: 139.4 (mm) IP-54 Weight 3 Kg. (*) Optional depending on model 29

Dimensions and cutout SIA-B PANEL CUTOUT 30

Technical specifications SIA-B Technical parameters SIA-B SIA-B 1 Overcurrent & Earth Fault Protection Relay - Dual & Self Powered PROTECTION FUNCTIONS 50_1 + 50/51 + 50G_1 + 50/51G + PGC PHASE MEASUREMENT In= 1 A: (0.10-30.00 A) 1 0 A F C D 0 2 3 2 A B C D C NEUTRAL MEASUREMENT In= 1 A: (0.05-16.00 A) NET FREQUENCY Defined by General Settings POWER SUPPLY Self-powered + Commissioning battery Self-powered + 24-230 Vac/dc (Dual) + Commissioning battery ADDITIONAL FUNCTIONS + 49 + SHB + 4 Settings groups + LDP + DFR + 52 + 49 + SHB + 4 Settings groups + LDP + DFR + 52 + 46 + Trip Block for switch disconnector + 50_2 + 50G_2 + CLP + 50BF COMMUNICATIONS USB (Modbus RTU) USB (Modbus RTU) + RS485 (Modbus RTU or DNP3.0 Serial) INPUTS AND OUTPUTS 4 LEDs + Trip (Striker) + 3 Outputs + 3 Inputs MECHANICAL ASSEMBLY Extended Horizontal Assembly LANGUAGE English, Spanish and German English, Spanish and Turkish English, Spanish and French English, Spanish and Russian ADAPTATION Standard CTs /1 Example of ordering code: SIA B 1 1 0 F C 0 3 2 A C SIA B 1 1 0 F C 0 3 2 A C 31