IB IL 24/48 DOR 2/W-XC-PAC

Similar documents
IB IL 24 DI 16 IB IL 24 DI 16-PAC

ILBIB24DO16-DSUB. Inline Block IO Module for INTERBUS With 16 Digital Outputs; Bus Connection via D-SUB Connectors

IB IL 120 DI 1. Function. INTERBUS Inline Terminal With One Digital Input in the 120 V AC Voltage Area. Data Sheet 5764B

IBS IL 24 BK RB-T-2MBD

ILBPB24DO32. Inline Block IO Module for PROFIBUS With 32 Digital Outputs. AUTOMATIONWORX Data Sheet 6889_en_04. Description

PHOENIX CONTACT - 11/2007. This data sheet is only valid in association with the IB IL SYS PRO UM E user manual.

This data sheet is only valid in association with the IL SYS INST UM E user manual.

IB ST 24 AO 4/EF. INTERBUS-ST analog output module, 4 outputs, 0-10 V, ±10 V, 0-20 ma, 4-20 ma. Data sheet. 1 Description

FLM DI 8 M12. Function. Fieldline Modular Device With Eight Digital Inputs. Data Sheet

IB IL AO 2/SF... Inline terminal with two analog outputs. AUTOMATION Data sheet 6655_en_06. 1 Description

IBS IL 24 RB-LK-2MBD:

PHOENIX CONTACT Features

ETD-BL-1T-230(-PT) Multifunctional time relay with various functions and adjustable times. Data sheet. 1 Description

PSR UC/ESAM4/3X1/1X2/B

PSR DC/ESP4/2X1/1X2

VAL-CP-1S-175. Extract from the online catalog. Order No.:

PSR-MS60. Safety relay for emergency stop, safety door and light grid monitoring. Data sheet. 1 Description

8 24 V DC, 8 24 V DC,

ETD-BL-1T-OFF-CC- 10S

VAL-CP-3S-350. Extract from the online catalog. Order No.:

PSR-SCP- 24DC/URM4/4X1/2X2/B PSR-SPP- 24DC/URM4/4X1/2X2/B

PSR-PC50. SIL 3 coupling relay for safety-related switch on. Data sheet. 1 Description

VersaPoint I/O Module

IB IL IB IL PAC

IL CAN BK-TC-PAC. Extract from the online catalog. Order No.:

MINI MCR-SL-UI-REL(-SP)

PSR-PS21. SIL coupling relay. Data sheet. 1 Description

PT 2-PE/S- 24AC-ST. Extract from the online catalog. Order No.:

PSR-PC20. SIL coupling relay. Data sheet. 1 Description

ILB DN 24 DI16 DO16. Inline Block IO Module for DeviceNet With 16 Digital Inputs and 16 Digital Outputs. AUTOMATIONWORX Data Sheet 6885_en_05

Rexroth Inline terminal with one analog output

PLC-OPT-230UC/ 24DC/2

PT 2X2-24DC-ST. Extract from the online catalog. Order No.:

PSR-SCP- 24DC/SSM/2X1 PSR-SPP- 24DC/SSM/2X1

PHOENIX CONTACT - 07/2006

PLC-RSC- 24DC/21 Order No.:

PHOENIX CONTACT - 10/2006

MINI MCR-SL-UI-2I(-SP)(-NC)

PLC-RSC- 24UC/21. Extract from the online catalog. Order No.:

EMD-FL-C-10. Electronic monitoring relay for overcurrent and undercurrent monitoring of direct and alternating current in single-phase networks

PLC-OPT- 24DC/230AC/1

AXL E IOL AO1 U M12 R

MINI MCR-SL-UI-2I. Configurable signal duplicator. Data sheet. 1 Description

MINI MCR-SL-CVS NC

QUINT-PS/ 1AC/24DC/ 5

IL CAN BK-TC-PAC. Extract from the online catalog. Order No.:

RAD-DOR4-IFS. I/O extension module, 4 digital relay outputs. INTERFACE Data sheet. 1 Description

PT 2X2-HF-24 DC-ST. Extract from the online catalog. Order No.:

PSR-SCP- 24DC/SDC4/2X1/B PSR-SPP- 24DC/SDC4/2X1/B

MINI MCR-SL-RPS-I-I. Repeater power supply, active. Data sheet. 1 Description

QUINT-PS-3x AC/24DC/10

PLC-RSC- 24DC/21. Extract from the online catalog. Order No.:

PHOENIX CONTACT - 01/2008

MINI MCR-SL-PT100-UI-200

TRIO-DIODE/12-24DC/2X10/1X20

FL MC 2000T. Fiber optic converter for 10/100Base-Tx to single- or multi-mode fiberglass with SC-duplex and ST connections. Data sheet 3379_en_B

MINI MCR-SL-PT100-UI(-SP)(-NC)

TRIO-PS/1AC/24DC/20. Extract from the online catalog. Order No.:

QUINT-PS/1AC/24DC/10. Extract from the online catalog. Order No.:

PT 5-HF- 5 DC-ST. Extract from the online catalog. Order No.:

EMD-SL-LL-230. Electronic monitoring relay for level monitoring of conductive liquids. INTERFACE Data sheet _en_04. 1 Description.

PHOENIX CONTACT - 05/2007

PHOENIX CONTACT - 11/2008

PHOENIX CONTACT - 01/2007

DEK-REL- 5/I/1. Extract from the online catalog. Order No.:

MINI MCR-SL-PT100-UI. Active resistance thermometer measuring transducer. Data sheet. 1 Description

MINI MCR-SL-UI-2I-NC. Extract from the online catalog. Order No.:

PLC-RSC- 24DC/ Extract from the online catalog. Order No.:

ASI QUINT /2.4 EFD

AXL E PB DIO16 M12 6P

PI-EX-ME-2NAM/COC-24VDC

MINI-PS AC/10-15DC/8

TT-2-PE- 24DC. Extract from the online catalog. Order No.:

RAD-DO8-IFS. I/O extension module, eight digital transistor outputs. Data sheet. 1 Description

Installation / Control Technique

QUINT-PS AC/24DC/10

IBS ST 24 BK-T INTERBUS-S. Data Sheet. Bus Terminal Module. Product Description

PI-EX-ME-2NAM/COC-120VAC

PLC-OSC-120UC/ 24DC/ 2

IBS ST (ZF) 24 BK LB-T

PSI-MODEM-SHDSL/PB. Broadband PROFIBUS extender, SHDSL PROFIBUS leased line modem. Data sheet _en_03. 1 Description. 1.

QUINT-PS/ 1AC/24DC/20/CO

PHOENIX CONTACT - 01/2010. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

TT-2-PE-M-24DC. Extract from the online catalog. Order No.:

FL MC 2000E (SM40) LC

Extract from the online catalog

MINI-DC-UPS/12DC/4. Extract from the online catalog. Order No.:

IB IL RS 232 IB IL RS 232-PAC

QUINT-BUFFER/24DC/24DC/40

RSTI-EP Slice I/O. Digital Output Module

PHOENIX CONTACT - 06/2007. DANGER OF EXPLOSION! Remove an item only when it is not connected to power or if it is located in the non-explosive area.

TT-SLKK5/ 24DC. Extract from the online catalog. Order No.:

QUINT-DC-UPS/24DC/10. Extract from the online catalog. Order No.:

QUINT-PS/24DC/48DC/ 5

Extract from the online catalog

SAFETY RELAY YRB-4EML-31S MAIN FEATURES

PHOENIX CONTACT - 08/2009. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

PSI-MODEM-SHDSL/SERIAL

AXL BK PN (-ME) Axioline bus coupler for PROFINET IO. Data sheet. 1 Description

Extract from the online catalog

Transcription:

Inline digital output terminal, version for extreme conditions, 2 relay PDTs Data sheet 8463_en_01 PHOENIX CONTACT 2015-08-12 1 Description The terminal is designed for use within an Inline station. It has two floating relay PDTs which are independent of each other. Thanks to special engineering measures and tests, the terminal can be used under extreme ambient conditions. Features Two relay outputs Floating connections for 2 actuators Nominal current of each output: 2 A Total current of the terminal: 4 A Segment voltage U S connected Diagnostic and status indicators Can be used under extreme ambient conditions Extended temperature range of -40 C... +70 C (see Tested successfully: use under extreme ambient conditions ) Painted PCBs WARNING: Undefined system state By default, the position of the relay contacts on the module is not defined. To prevent undesired system states, perform a complete cycle (on/off) before connecting the segment voltage. This data sheet is only valid in association with the IL SYS INST UM E user manual. Make sure you always use the latest documentation. It can be downloaded from the product at phoenixcontact.net/products.

2 Table of contents 1 Description... 1 2 Table of contents... 2 3 Ordering data... 3 4 Technical data... 3 5 Additional tables... 6 5.1 Maximum switching current for ohmic load depending on the switching voltage... 6 5.2 Power dissipation... 6 5.3 Limitation of simultaneity, derating... 7 5.4 Air clearances and creepage distances... 7 6 Tested successfully: Use under extreme ambient conditions... 8 7 Internal circuit diagram... 9 8 Special features of the terminal...9 8.1 Switching a voltage equal to the segment voltage... 9 8.2 Switching a voltage unequal to the segment voltage... 9 9 Local status and diagnostic indicators... 10 10 Terminal point assignment...10 11 Connection notes and examples... 11 12 Process data... 11 8463_en_01 PHOENIX CONTACT 2

3 Ordering data Description Type Order No. Pcs./Pkt. Inline digital output terminal, version for extreme conditions, complete with accessories (connector plug and labeling field), 2 relay PDTs, gold contact, 5-48 V DC, 2 A IB IL 24/48 DOR 2/W-XC-PAC 2701214 1 Accessories Type Order No. Pcs./Pkt. Labeling field, width: 12.2 mm (Marking) IB IL FIELD 2 2727501 10 Insert strip, Sheet, white, unlabeled, can be labeled with: Office printing systems, Plotter: Laser printer, Mounting type: Insert, Lettering field: 62 x 10 mm (Marking) Connector, for digital 1, 2 or 8-channel Inline terminals (Connector/ Adapter) Zack Marker strip, flat, Strip, white, unlabeled, can be labeled with: Plotter, Mounting type: Snap into flat marker groove, for terminal block width: 6.2 mm, Lettering field: 5.15 x 6.15 mm (Marking) ESL 62X10 0809492 1 IB IL SCN-8 2726337 10 ZBF 6:UNBEDRUCKT 0808710 10 Zack Marker strip, flat, white, for terminal block width: 6.2 mm (Marking) ZBF 6:SO/CMS 0808778 1 Flat zack marker sheet, white, for terminal block width: 6.2 mm (Marking) ZBFM 6:SO/CMS 0803650 1 Flat zack marker sheet, Sheet, white, unlabeled, can be labeled with: Plotter, Mounting type: Snap into flat marker groove, for terminal block width: 6.2 mm, Lettering field: 5 x 5.5 mm (Marking) ZBFM 6/WH:UNBEDRUCKT 0803618 10 Inline distance terminal, complete with accessories IB IL DOR LV-SET-PAC 2861645 1 Documentation Type Order No. Pcs./Pkt. Application note, English, The safety-related segment circuit AH EN IL SAFE - - Data sheet, English, INTERBUS addressing DB GB IBS SYS ADDRESS - - Application note, English, Using distance terminal blocks and interference suppression measures on inductive loads AH EN IB IL DOR - - 4 Technical data Dimensions (nominal sizes in mm) 140,5 119,8 71,5 Width Height Depth Note on dimensions 12.2 mm 119.8 mm 71.5 mm Housing dimensions 8463_en_01 PHOENIX CONTACT 3

General data Color green Weight 63 g (with connector) Operating mode Process data mode with 2 bits Ambient temperature (operation) -25 C... 55 C (Standard) -40 C... 70 C (Extended, see section Tested successfully: use under extreme ambient conditions in the data sheet.) Ambient temperature (storage/transport) -40 C... 85 C Permissible humidity (operation) 10 %... 95 % (according to DIN EN 61131-2) Permissible humidity (storage/transport) 10 %... 95 % (according to DIN EN 61131-2) Air pressure (operation) 70 kpa... 106 kpa (up to 3000 m above sea level) Air pressure (storage/transport) 70 kpa... 106 kpa (up to 3000 m above sea level) Degree of protection IP20 Protection class III, IEC 61140, EN 61140, VDE 0140-1 Connection data Designation Inline connector Connection method Spring-cage connection Conductor cross section solid / stranded 0.08 mm²... 1.5 mm² / 0.08 mm²... 1.5 mm² Conductor cross section [AWG] 28... 16 Stripping length 8 mm Interface Inline local bus Connection method Transmission speed Inline data jumper 500 kbit/s Power consumption Communications power U L 7.5 V DC Current consumption from U L max. 30 ma Power consumption 0.23 W (at U L ) Relay output Number of outputs 2 Connection method Spring-cage connection Connection method Floating SPDT relay contact Nominal output voltage 48 V DC Output voltage range 5 V AC... 30 V AC 5 V DC... 60 V DC Maximum output current per channel 2 A Contact type 2 floating PDT contacts Contact material AgSnO 2, hard gold-plated Contact resistance 75 mω Switching voltage min. 10 mv (DC) max. 30 V AC (PELV (EN 61131)) max. 60 V DC (PELV (EN 61131)) Switching current min. 10 µa 2 A (30 V DC) 1 A (60 V DC) Limiting continuous current 2 A (at maximum ambient temperature) Switching capacity 60 W 62.5 VA (ohmic) Switching frequency 1 Hz (without load) ; 1 Hz (with load) Nominal power consumption 200 mw 8463_en_01 PHOENIX CONTACT 4

Relay output Coil resistance Typical response time Bouncing time Typical release time Service life, electrical Mechanical service life Common potentials 178 Ω ±10 % (at 20 C) typ. 20 ms 4 ms (for on and off) typ. 20 ms 10 8 cycles 2x 10 5 cycles all contacts floating Programming data (INTERBUS, local bus) ID code (hex) BD ID code (dec.) 189 Length code (hex) 2C Length code (dec.) 44 Process data channel 2 Bit Input address area 0 Bit Output address area 2 Bit Parameter channel (PCP) 0 Bit Register length (bus) 2 Bit For the programming data/configuration data of other bus systems, please refer to the corresponding electronic device data sheet (e.g., GSD, EDS). Configuration and parameter data in a PROFIBUS system Required parameter data Need for configuration data 3 Byte 4 Byte Error messages to the higher level control or computer system None Electrical isolation/isolation of the voltage areas Test section Relay contact / Bus logics Test voltage 1.5 kv, 50 Hz, 1 min Contact/contact 1 kv, 50 Hz, 1 min Contact / PE 1 kv, 50 Hz, 1 min To achieve electrical isolation between the logic level and the I/O area, supply these areas from separate power supply units. Interconnection of the power supply units in the 24 V area is not permitted (see also user manual). Approvals For the latest approvals, please visit phoenixcontact.net/products. 8463_en_01 PHOENIX CONTACT 5

5 Additional tables 5.1 Maximum switching current for ohmic load depending on the switching voltage Switching voltage (V DC) 10 2.0 20 2.0 30 2.0 60 1.0 Switching current (A) 5.2 Power dissipation Formula for calculating the power dissipation of the electronics P = 0,23 W + m x 0,14W + (I x 0,075) EL n 2 Li i = 1 Load current I L as a function of the switching voltage U S I L 3,0 A 2,0 1,0 0,3 0,1 10 30 100 V 200 2 1 Where: P EL Total power dissipation in the terminal i Continuous index n Number of set outputs (n = 1... 2) m Number of relays with controlled coil I Li Load current of output i Power dissipation of the housing P HOU = 1.2 W -25 C T A < +25 C P HOU = 1.2 W - [(T A - 25 C) x 0.02 W/ C] +25 C < T A +55 C Figure 1 1 DC, ohmic load 2 AC, ohmic load U S Load current I L as a function of the switching voltage U S Number of operations N as a function of the load current I L Where: P HOU T A Power dissipation of the housing Ambient temperature 100 x10 4 50 N 30 20 2 1 10 Figure 2 1,0 A 2,0 I L Number of operations N as a function of the load current I L 1 30 V DC, ohmic load 2 125 V AC, ohmic load 8463_en_01 PHOENIX CONTACT 6

5.3 Limitation of simultaneity, derating Derating when using the N/O contact Ambient temperature T amb Power dissipation of the housing Maximum load current 100 % simultaneity 50 % simultaneity 40 C 0.9 W 2.0 A 2.0 A 55 C 0.6 W 1.0 A 2.0 A 5.4 Air clearances and creepage distances Air clearances and creepage distances (according to EN 50178, VDE 0109, VDE 0110) Isolating distance Clearance Creepage distance Test voltage Relay contact/bus logic 1.5 mm 1.5 mm 1.5 kv, 50 Hz, 1 min. Contact/contact 1.5 mm 1.5 mm 1.0 kv, 50 Hz, 1 min. Contact/PE 3.1 mm 3.1 mm 1.5 kv, 50 Hz, 1 min. Relay/relay None 8463_en_01 PHOENIX CONTACT 7

6 Tested successfully: Use under extreme ambient conditions XC terminals have been tested successfully over 250 temperature change cycles in accordance with IEC 61131-2 in the range from -40 C to +70 C. The following conditions were observed: The Inline devices for all connecting cables were connected with a minimum conductor cross section of 0.5 mm² The Inline station was assembled on a wall-mounted horizontal DIN rail Fans were used to ensure continuous movement of air in the control cabinet The Inline station was not exposed to vibration or shock The Inline station was operated with a maximum of 24.5 V (ensured by using regulated power supply units) T max + 2 K 3 h + 30 min t 1 (3 + 0,6) K/min T min + 3 K 3 h + 30 min t 1 1 Figure 3 Temperature change cycle Temperature in the control cabinet/ambient temperature Cycle WARNING: The terminal is not approved for use in potentially explosive areas. The terminal is not approved for use in safety technology. 8463_en_01 PHOENIX CONTACT 8

7 Internal circuit diagram 8 Special features of the terminal? = > K I 2 + See also the information in the AH EN IB IL DOR application note. 7 7 5 7 8.1 Switching a voltage equal to the segment voltage The potential U S is available at terminal points 1.1 and 1.2. If you insert a jumper between 1.1 and 1.3 or 2.1 and 2.3, you connect the segment voltage potential to the main contact of the relevant relay and can therefore switch the connected load in a non-isolated manner. If you do not insert a jumper, you can switch the load in a floating manner. 8.2 Switching a voltage unequal to the segment voltage Different DC voltages Distance terminals are not required. Only floating switching of the load is permitted. Do not, therefore, attach any jumpers to the connector. Figure 4 Key: OPC Internal wiring of the terminal points Protocol chip (Bus logic including voltage conditioning) LED Relay $ & #! If the switch contact potentials and the segment circuit potential are two different DC circuits, Phoenix Contact recommends establishing a ground connection between the two power supply units. Switching an AC voltage within a DC segment circuit Place distance terminals in front of and behind the relay terminal block. The distance terminals interrupt the potential jumpers. As a result, no segment voltage is present at terminal points 1.1 and 2.1. It is only possible to switch the connected load in a floating manner. Electrically isolated area I/O area including relay contact isolated from the logic area including the relay coil Explanation for other used symbols has been provided in the IL SYS INST UM E user manual. 8463_en_01 PHOENIX CONTACT 9

9 Local status and diagnostic indicators 10 Terminal point assignment 1 D 2 1.1 1.1 2.1 2.1 Figure 5 Local status and diagnostic indicators 1.2 1.2 2.2 2.2 Designation Color Meaning D Green Diagnostics (bus and logic voltage) 1... 2 Yellow Status of the outputs (relay has picked up) 1.3 1.4 1.3 2.3 1.4 2.4 2.3 2.4 Function identification Figure 6 Terminal point assignment Pink Housing/connector color Green housing Green, unprinted connector Terminal point Assignment 1.1 / 2.1 Segment voltage U S 1.2 Relay N/C contact Relay 1 1.3 Relay main contact Relay 1 1.4 Relay N/O contact Relay 1 2.2 Relay N/C contact Relay 2 2.3 Relay main contact Relay 2 2.4 Relay N/O contact Relay 2 8463_en_01 PHOENIX CONTACT 10

11 Connection notes and examples NOTE: Damage to the electronics Use the terminal within the PELV range (EN 61131) up to a maximum of 30 V AC or 60 V DC. N/C contact Main contact N/O contact 1.1 2.1 1.2 1.3 1.4 2.2 2.3 2.4 12 Process data Assignment of the terminal points to the output process data (Byte.Bit) view 0.1 0.0 N/O contact 2 (contact 2.4) Possible bit combinations N/O contact 1 (contact 1.4) 0 0 open open 0 1 open closed 1 0 closed open 1 1 closed closed Status indicator LED 2 1 The LED lights up if the corresponding N/O contact is closed. Figure 7 Actuator connection; floating connection For the assignment of the illustrated (byte.bit) view to your INTERBUS control or computer system, please refer to the DB GB IBS SYS ADDRESS data sheet. 1.1 2.1 1.2 2.2 1.3 2.3 1.4 2.4 Figure 8 Actuator connection; non-isolated connection Hauptkontakt/ Main contact Figure 9 1.3 Output relay contacts 1.2 1.4 Öffnerkontakt/ N/C contact Schließerkontakt/ N/O contact 8463_en_01 PHOENIX CONTACT GmbH & Co. KG 32823 Blomberg Germany 11 phoenixcontact.com