Digital Quick-Response Thermometer

Similar documents
GMH Operating Manual for Digital Quick-Response Thermometer

Manometer. (Over- /Under- And Difference Pressure) Operating Manual GDH

Hygro-/Thermometer. Operating Manual GFTH 95

GREISINGER electronic GmbH D Regenstauf, Hans-Sachs-Straße 26 phone: / , fax: / ,

GREISINGER electronic GmbH D Regenstauf, Hans-Sachs-Straße 26

GREISINGER electronic GmbH D Regenstauf, Hans-Sachs-Straße 26 phone: / , fax: / ,

GREISINGER electronic GmbH D Regenstauf, Hans-Sachs-Straße 26

Operating Manual Digital Quick Response Thermometer GMH 3210 For Thermocouple Probes Type J, K, N, S, T from Version 1.0

GREISINGER electronic GmbH D Regenstauf, Hans-Sachs-Straße 26

GREISINGER electronic GmbH. D Regenstauf, Hans-Sachs-Straße 26. T-Logg 100. T-Logg 100 E

Precision thermometer

Digital Precision Hand-held Measuring Device

Hand-held measuring device with alarm function

GREISINGER electronic GmbH. D Regenstauf, Hans-Sachs-Straße 26. T-Logg 120 W -... T-Logg 120 K -...

Digital Precision Hand-held Measuring Device

Universal interface adapter for GMSD / GMxD - sensor

GHM Messtechnik GmbH Standort Greisinger Hans-Sachs-Str. 26 D Regenstauf +49 (0) 9402 / (0) 9402 /

GMH to 1300 mbar absolute Version 4.7

Operating manual. GTL - Configuration tool. Please keep the manual for future use.

GREISINGER electronic GmbH D Regenstauf, Hans-Sachs-Straße 26

Operating manual GTL 142 GTL 152. Temperature probe. Please keep the manual for future use.

Operating Manual Configuration software for EASYBus devices

Precision thermometer

Operating Instructions for Hand-held Conductivity Measuring Units. Model: HND-C110

English. Operating Manual. Conductive point level switch MLR120. Retain for later reference. Companies / brands of GHM

USER MANUAL VIBRATION CONTROL RMA-POWER-BOX 107/230

English. Operating manual. Universal transmitter UT125. Save for later reference. Companies / brands of GHM

Polymer Electric. Operating Instructions. Control Unit SG-EFS 1X4 ZK2/1 8k2. Version 3

LCD LCDS LCDRI CONTROLLER OPERATING MANUAL

-auto Power Off- T1/T2/T1-T2

Operating Instructions Differential Pressure Transducer PS27

DPX-620III 6-Ch. dimmer pack. user manual

GIR 230 TC Version 1.1

D610H, D610H MKII, D610S, D610T dimmer pack. user manual

Electronic Temperature Controller. Instruction Manual Version

DDC-6, DDC-12 LCD DMX controller. user manual

Operating Instructions

TETRIS 2500 High Impedance Active Probe. Instruction Manual

Instruction Manual FB-606 FB-606 TF. Infrared Manual Remote Control. LJU Automatisierungstechnik GmbH

TVAC25100 TVAC25110 User manual

D1210H dimmer pack. user manual

CMC III Temperature/Humidity Sensor

Englisch. Operating Manual. Operating Software GHMware Retain for further references. Unternehmen / Marken der GHM

HP4 headphone amplifier. user manual

Operating instructions. Standstill monitor A / / 2011

Classic Flanger effects pedal. user manual

Temperature & Humidity Datalogger

CMC III Universal Sensor

D-SEED effects pedal. user manual

DDS 405 digital dimmer and switcher. user manual

Kvaser USBcan Light User s Guide

Operating instructions. Speed monitor D / / 2014

Polymer Electric. Operating Instructions. Control Unit SG-RST 153. Version 0.3

DMX Splitter 4 MKIII 19" DMX splitter. user manual

Operation Manual Series W-500

LED Commander 16/2 DMX controller. user manual

Operating Instructions PRO-AB /6.15. Leakage Current Measuring Adapter

DIGITAL SOUND 8922 Owner s manual Sound level meter

Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016

Compact universal controllers

Operating instructions. Switching amplifier DN0210 DN / / 2015

Manual. Polaron SMPS Watt power supply for chargers. No. S2024. Copyright Graupner/SJ GmbH

Operating Instructions VEGAMET 381

DDS-405 LC DMX 4 Ch. Dimmer dimmer pack. user manual

PTB 01 ATEX 2064 U, IECEx PTB U. Example / Beispiel / Exemple: Type Operating Instructions

GREISINGER electronic GmbH D Regenstauf, Hans-Sachs-Straße 26

PF LED Profile. User Manual

UP-1-1 Channel Dimmer. User manual. dimmer pack

KHT 6000 C HV-Probe Calibrator. Instruction Manual

UC102 basic version with display and knob UC102BL version with display, knob and backlight UC102DK version without knob and display

NL-324BTR User manual (60706)

Blitzer Strobe. User Manual. Order code: EQLED366

Type ME43. Quickstart

Control unit SG-EFS 104/2W. EN Operating instructions. Innovative by tradition. Version SG-EFS 104/2W 24 V=/~

TC100 Precision Thermocouple Calibrator

Kvaser Mini PCI Express HS v2 User s Guide

UP-1-1 Channel Dimmer dimmer pack. user manual

Crossfire. User Manual. Order code: EQLED061

Vector Beam White. User Manual. Order code: LEDJ265

UV Power Flood. User Manual. Order code: EQLED029

DS 96/48 PK. Digital indicator. Manual 42/33-90 EN Rev. 00 DIM

RS Stock No Instruction Manual RS Input Data Logging Thermometer

English. Operating manual. Limit switch GS125. Keep for future reference. Ventures / brands of GHM

INSTRUCTION MANUAL. Models: H200 Single Channel K, J, T, E, R Thermometer

LED Pixel Rail Drive 640 controller. user manual

Wireless Module and RS-485 Module INSTRUCTION MANUAL P

Kvaser PCIEcan HS v2 User s Guide

Polymer Electric. Operating Instructions. Control Unit SG-TRS 3X8. Version 1

PTZ Control VMC Joystick

DMX LED Starcloth Systems

DM-918 OPERATIONS MANUAL AUTORANGING MULTIMETER

PTB 01 ATEX Example / Beispiel / Exemple. Type Operating Instructions

Operating and Installation Manual. EASYLAB Expansion modules Type EM-TRF for 230 V AC mains voltage

BlueBox. Installation and user manual

ZF LED Zoom Fresnel. User Manual

TA18 active subwoofer. user manual

PowerPlant Tuner tuner pedal with power distribution. user manual

English. Instruction and operation manual S 505. Dew point meter (portable)

Valid for item nos.: (1-zone) (2-zone) (4-zone) (6-zone) HPS-C-Slot Hotrunner controllers Operating manual

Operation manual SERIES Z60-000

Transcription:

H56.0.01.6C-06 Digital Quick-Response Thermometer Operating Manual GTH 1170 WEEE-Reg.-Nr. DE93889386 GHM Messtechnik GmbH Standort Greisinger Hans-Sachs-Str. 26 D-93128 Regenstauf +49 (0) 9402 / 9383-0 +49 (0) 9402 / 9383-33 info@greisinger.de

H56.0.01.6C-06 Operating Manual GTH 1170 Page 2 of 6 CONTENTS 1 GENERAL NOTE... 2 2 SAFETY... 3 2.1 INTENDED USE... 3 2.2 SAFETY SIGNS AND SYMBOLS... 3 2.3 SAFETY GUIDELINES... 3 3 PRODUCT SPECIFICATION... 4 3.1 SCOPE OF SUPPLY... 4 3.2 OPERATION AND MAINTENANCE ADVICE... 4 4 NOTES TO FUNCTIONS OF DEVICE... 4 4.1 IN GENERAL: MEASURING TEMPERATURE WITH THERMOCOUPLES... 4 4.2 MIN-/MAX VALUE MEMORY... 4 4.3 HOLD FUNCTION... 4 4.4 OFFSET AND SCALE ADJUSTMENT... 4 5 CONFIGURATION OF THE INSTRUMENT:... 5 5.1 AUTO POWER OFF TIME... 5 5.2 DISPLAY UNIT: CHOICE OF THE TEMPERATURE DISPLAY UNIT... 5 5.3 DISPLAY RESOLUTION: CHOICE OF THE TEMPERATURE DISPLAY RESOLUTION... 5 6 SYSTEM MESSAGES:... 6 7 SPECIFICATION... 6 8 RESHIPMENT AND DISPOSAL... 6 8.1 RESHIPMENT... 6 8.2 DISPOSAL INSTRUCTIONS... 6 1 General Note Read this document carefully and get used to the operation of the device before you use it. Keep this document within easy reach near the device for consulting in case of doubt. Mounting, start-up, operating, maintenance and removing from operation must be done by qualified, specially trained staff that have carefully read and understood this manual before starting any work. The manufacturer will assume no liability or warranty in case of usage for other purpose than the intended one, ignoring this manual, operating by unqualified staff as well as unauthorized modifications to the device. The manufacturer is not liable for any costs or damages incurred at the user or third parties because of the usage or application of this device, in particular in case of improper use of the device, misuse or malfunction of the connection or of the device. The manufacturer is not liable for misprints.

H56.0.01.6C-06 Operating Manual GTH 1170 Page 3 of 6 2 Safety 2.1 Intended Use The safety requirements (see below) have to be observed. The device must be used only according to its intended purpose and under suitable conditions. Use the device carefully and according to its technical data (do not throw it, strike it, ) Protect the device from dirt. 2.2 Safety signs and symbols Warnings are labelled in this document with the followings signs: Caution! This symbol warns of imminent danger, death, serious injuries and significant damage to property at non-observance. Attention! This symbol warns of possible dangers or dangerous situations which can provoke damage to the device or environment at non-observance. Note! This symbol point out processes which can indirectly influence operation or provoke unforeseen reactions at non-observance. 2.3 Safety guidelines This device has been designed and tested in accordance with the safety regulations for electronic devices. However, its trouble-free operation and reliability cannot be guaranteed unless the standard safety measures and special safety advises given in this manual will be adhered to when using the device. 1. Trouble-free operation and reliability of the device can only be guaranteed if the device is not subjected to any other climatic conditions than those stated under "Specification". 2. If the device is transported from a cold to a warm environment condensation may cause in a failure of the function. In such a case make sure the device temperature has adjusted to the ambient temperature before trying a new start-up. 3. If there is a risk whatsoever involved in running it, the device has to be switched off immediately and to be marked accordingly to avoid re-starting. Operator safety may be a risk if: - there is visible damage to the device - the device is not working as specified - the device has been stored under unsuitable conditions for a longer time. In case of doubt, please return device to manufacturer for repair or maintenance. 4. Warning: Do not use this product as safety or emergency stop devices or in any other application where failure of the product could result in personal injury or material damage. Failure to comply with these instructions could result in death or serious injury and material damage.

H56.0.01.6C-06 Operating Manual GTH 1170 Page 4 of 6 3 Product Specification 3.1 Scope of supply The scope of supply includes: Device GTH1170, incl. 9V battery block Operating Manual 3.2 Operation and maintenance advice Battery operation: If bat is shown in the lower display the battery has been used up and needs to be replaced. However, the device will operate correctly for a certain time. If bat is shown in the upper display the voltage is too low to operate the device; the battery has been completely used up. The battery has to be taken out, when storing device above 50 C. We recommend taking out battery if device is not used for a longer period of time. Treat device carefully. Use only in accordance with above specification. (do not throw, hit against etc.). Protect plug and socket from soiling. Make sure that sensor and device are always subjected to the same temperature, i.e. try to avoid holding sensor plug in your hand for a longer period of time as well as subjecting device to an additional heat source as this may result in measuring inaccuracies. 4 Notes to Functions of Device 4.1 In General: Measuring Temperature With Thermocouples Temperature differences between the instrument and the probe connector may produce measuring errors. Therefore wait after connecting or touching the connector until the temperatures have adjusted. (can take up to 15 mins. ) The device is suitable to measure large temperature ranges. But consider the allowable range of your probe! When measuring air temperature the probe has to be dry. Otherwise the cold due to the evaporation causes to low measuring. 4.2 MIN-/MAX Value Memory watch MIN value (Lo): press key Mode shortly once display changes between Lo and MIN value watch MAX value (Hi): press key Mode shortly once again display changes between Hi and MAX value restore current value: press key Mode shortly once again current value is displayed clear MIN-/MAX- value: press key Mode for 2 seconds MIN and MAX value are cleared. The display shows shortly CLr. 4.3 Hold Function By shortly pressing the Hold key the currently measured value is frozen, The display changes between Hld and the frozen value Pressing the key Hold shortly once again resets the display to the current value. Please note: Measuring keeps on running in the background, the MIN/MAX values are updated continuously. 4.4 Offset and Scale Adjustment The offset and scale adjustment is mainly intended to be used to compensate errors of the external temperature probes. The display value is given by following formula: unit = C: Display = (measured value - offset) * ( 1 + scale adjustment [%] ) unit = F: Display = (measured value - 32 F - offset) * ( 1 + scale adjustment [%] ) + 32 F

H56.0.01.6C-06 Operating Manual GTH 1170 Page 5 of 6 To adjust a measuring offset and scale proceed like follows: 1. Switch off the instrument. 2. Press the Hold key while switching on the instrument. Keep Hold key pressed until OFS appears in the display (about 3 seconds). 3. Press Mode or Hold key, the currently selected offset adjustment appears. 4. Choose the desired value by pressing Mode or Hold key. (max. input range: ±5.0 C or ±9.0 F) 5. Enter by pressing On/Off-key: SCL appears in the display 6. Press Mode or Hold key, the currently selected scale adjustment appears 7. Choose the desired value by pressing Mode or Hold key. (max. input range: ±5.00%) The input is displayed in %. example: scale adjustment is 4.00 => scale is increased by 4.00% => Scale = 104% At a measured value of 100.0 (without offset correction) the instrument would show 104.0 8. Store the values by pressing On/Off key. Please note: If during the changing of the offset adjust no key is pressed within 20 seconds, the input will be aborted. Eventually made changes won t be stored! 5 Configuration Of The Instrument: To configure the instrument proceed like follows: 1. Switch off the instrument. 2. Press the Mode key while switching on the instrument, keep Mode key pressed until PoF appears (about 3 seconds). 5.1 Auto Power Off Time The auto power off time is entered in minutes. If no key is pressed during a measuring, the instrument switches itself off automatically after the entered period of time. 3. Press Mode or Hold key, the currently selected power off time will be displayed (off, 1..120min) 4. Enter the desired time by pressing Mode or Hold key. Possible input: off: The auto power off function is deactivated (permanent operation) 1...120: auto power off time in minutes. 5. Confirm the value by pressing On/Off key, Uni appears in the display 5.2 Display Unit: Choice of the temperature display unit C or F 6. Press Mode or Hold key, the currently selected unit will be displayed ( C or F) 7. Enter the desired unit by pressing Mode or Hold key. 8. Confirm the value by pressing On/Off key, res appears in the display 5.3 Display Resolution: Choice of the temperature display resolution 1 or 0.1 9. Press Mode or Hold key, the currently selected resolution will be displayed (1 or 0.1 ) 10. Enter the desired resolution by pressing Mode or Hold key. 0.1 : Display 0.1 C or 0.1 F. When exceeding the display range (>199.9 ) the display automatically changes to 1 resolution 1 : Display with 1 C or 1 F resolution 11. Confirm the value by pressing On/Off key. The vales will be stored, the instrument will restart (segment test). Please note: If during the configuration no key is pressed within 20 seconds, the configuration will be aborted. Eventually made changes won t be stored!

H56.0.01.6C-06 Operating Manual GTH 1170 Page 6 of 6 6 System Messages: Er. 1 = measuring range has been exceeded Er. 2 = meas. values have fallen below perm. range Er. 7 = System fault - the device has detected a system fault (defective or far outside allowable ambient temperature range) --- = No temperature probe connected or probe defective If the symbol "BAT is displayed at the left side of display, the battery is weak, measuring can be continued for a certain time. If bat is displayed in the main display the battery is used up and needs to be replaced. Measuring is no more possible. 7 Specification Measuring range: -65,0... +199,9 C, resolution 0,1 C resp. -85,0... +199,9 F, resolution 0,1 F -65... +1150 C, resolution 1 C resp. -85... +1999 F, resolution 1 F Precision: (±1 Digit) -65,0...+199,9 C: ±0,05 % of meas. value ±0,2% full scale (at nominal temperature = 25 C) -65... +1150 C: ±0,1 % of meas. value ±0,2 % full scale Temperature drift: 0,01 %/K Point of comparison: ±0,3 C Probe connection: standard flat-pin plug suitable for all NiCr-Ni (type K) probes Offset- and Scale: digital offset and scale adjustment via menu setting Measuring frequency: 3 measurings per second Display: approx. 13 mm high, 3½-digit LCD Operation elements: 3 keys for ON/OFF, min-/max-value display, hold Min-/Max-value memory: Min and max measured value is stored Hold key: the current measuring will be frozen Operating conditions: -25... 50 C; 0... 80 %RH (non-condensing) Storage temperature: -25... 70 C Power supply: 9V battery type JEC 6F22 (in scope of supply) Power consumption: approx. 150 µa Low battery warning: "BAT" automatically displayed if battery is low Auto off function: when the Auto Off Function is activated, the device switches automatically off, if keypad is not attended for a longer time (selectable 1...120min). Housing: impact resistant ABS-housing: approx.106 x 67 x 30 mm (H x W x D) Weight: approx. 135g incl. battery EMC: The device corresponds to the essential protection ratings established in the Regulations of the Council for the Approximation of Legislation for the member countries regarding electromagnetic compatibility (2004/108/EG). Additional fault: <1% 8 Reshipment and Disposal 8.1 Reshipment All devices returned to the manufacturer have to be free of any residual of measuring media and other hazardous substances. Measuring residuals at housing or sensor may be a risk for persons or environment Use an adequate transport package for reshipment, especially for fully functional devices. Please make sure that the device is protected in the package by enough packing materials. 8.2 Disposal instructions Batteries must not be disposed in the regular domestic waste but at the designated collecting points. The device must not be disposed in the unsorted municipal waste! Send the device directly to us (sufficiently stamped), if it should be disposed. We will dispose the device appropriate and environmentally sound.