ERF910. RF Repeater. Synco living

Similar documents
RF adapter plugs, dimming

Heating Circuit Controller

Heating Circuit Controller

Room Temperature Controller

Mobile Data Collector

Resistance measuring module

RMZ782B RMZ783B. Extension Modules. Building Technologies HVAC Products. Synco 700. for heating controller RMH760B

TXM1.8T. Triac module Used for Thermic and motor-driven actuators (AC 24 V) TX-I/O

QXA2000 QXA2001. Condensation Monitor QXA2001 QXA2000 AQX2000

Power supply module, bus connection module

Universal Modules. Synco 700. Extension modules for use with controls of the Synco 700 family. Use

RMZ792. Bus Operator Unit. Building Technologies HVAC Products. Synco 700

Web interface BACnet/IP

Semi flush-mounted room temperature controllers with LCD

OCI Service tool. As of ACS790 V9.00. Service case with software and service interface

Electromotoric actuators

RMZ782B RMZ783B. Extension Modules. Building Technologies HVAC Products. Synco 700. for heating controller RMH760B

Room sensors QFA4160 QFA41 D AQF4150 AQF3153. Symaro. for relative humidity and temperature with calibration certificates

Network node WTT56.. A6V _en--_c Building Technologies

Island bus expansion module

Extension module for lighting control

Status display unit with P-bus connection

Immersion Temperature Sensors

Room unit with PPS2 interface

USB-KNX Interface OCI702. USB-KNX interface with cables and service bag

Communication module to connect M-bus devices to POL6xx.xxx controllers.

Extension module Integration of existing PTM I/O modules in Desigo Used with PXC50...D, PXC100...D or PXC200...D

RXM39.1. PL-Link IO Block. Desigo TRA. Use with PXC3 series room automation station

Room unit with PPS2 interface

TXM1.8U TXM1.8U-ML. Universal modules TX-I/O

TXM1.8U TXM1.8U-ML. Universal modules TX-I/O

Semi flush-mounted room temperature controllers with LCD

Room Temperature Controller

SEH62.1. Digital Time Switch

Duct Sensors. Building Technologies HVAC Products. Symaro. for relative humidity and temperature with calibration certificates

Room Temperature Controllers

Semi Flush-mount Room Temperature Controllers with LCD

SAX.. ACVATIX Electromotive actuators for valves. with a 20 mm stroke

Electrical Actuators

Rotary actuators for ball valves

Electrical Actuators

RXB39.1. Room controller RXB. Communicating room controller for fan-coil applications FC-13

Electrical Actuators

Room unit with PPS2 interface

Room unit with PPS2 interface

M-bus web server. Meters and Energy Cost Allocation WTV676-HB6035

TXM1.8RB. TX-I/O Blinds module

Rotary version, three-position control

RMZ790. Operator Unit. Building Technologies. Synco 700

s Climatix AHU ext. module 14 I/O POL955.XX/XXX Climatix

Universal Controller

Electrical actuators

Digital input modules

Fast running actuators for air dampers

Communication over Modbus protocol Connection with multiple controllers Application upgrade by using an SD 1) card or a USB stick

QAX50.1 QAX50.5 QAX51.1 QAX51.5. Flexible room unit. Desigo RXC

RXC39.5. Room controller. Building Technologies. Desigo RXC. Communicating room controller for fan-coil applications

Electromotive actuators for combi valves

Electromotoric actuators

M-bus RF gateway. Meters and Energy Cost Allocation WTT563-0C0000

OCI Service Tool. Siemens Building Technologies HVAC Products. ACS plant operating software and OCI700 service interface

Interface converter for VAV compact controllers

Network nodes with gateway

RDF301 RDF CE1N3171en 02 Jun 2010 Building Technologies

Master room unit for RRV controllers

Handheld Tool for VAV compact and modular controllers

CLIMATIX STEQ, STCM DATASHEET FOR CONTROLLING, SWITCHING AND MONITORING FUNCTIONS. POWER SUPPLY RELAY OUTPUTS. Power supply. 4.

OEM. Room unit QAA822 with2- wire interface. Building Technologies CLIMATIX TM. For use with Climatix controllers

Electromotoric actuators

Air damper actuators

VAV compact controller KNX / PL-Link

Room Temperature Controller with 7-Day Time Switch, LCD and opt. Remote Temperature Sensor

AEW Pulse Adapter. Building Technologies

Electromotoric actuators

VAV modular controller

Temperature Controller

AEW36.2. Pulse Adapter. Building Technologies. Siemeca AMR

RXL24.1. Room controller RXL. Communicating controller for chilled ceiling and radiator applications CC-02

QVE3000.0xx QVE3100.0xx. Flow sensor. for liquids in DN10 25 pipes

Weekday / weekend room temperature controller

M-Bus Central Unit. Use

OZW V3.0. Web server. For Synco TM, Synco TM living

Cube LAN Gateway. Operating manual BC-LGW-O-TW

Central control unit

7-day room temperature controller

Switching module for AC V and up to three load stages, with manual switching

BACnet/IP Web Interface

RTT2 ROOM TEMPERATURE SWITCH. Mounting and operating instructions

VAV compact controller

7-day room temperature controller

TXM1.8U TXM1.8U-ML. Universal modules TX-I/O

PXM20-E. Operator unit BACnet auf Ethernet/IP DESIGO PX

RТTH DUAL ROOM SWITCH

Super universal modules

DESIGO RX Individual room controllers. for fan-coil systems, chilled ceilings and radiators, with LONMARK-compatible bus communications

Airflow Pressure Sensor

Switching and Monitoring Device

9283P01. Extension module. Integration of existing PT-I/O modules in Desigo Used with PXC50...D, PXC100...D or PXC200...D

QMX3.P30 QMX3.P70 QMX3.P02 QMX3.P34 QMX3.P74 QMX3.P37. Wall-mounted sensors and room operator units for KNX PL-Link, KNX S-mode and KNX LTE-Mode

Room automation station

Transcription:

2 704 Synco living RF Repeater ERF910 Wireless RF repeater for extending plant RF communication based on KNX standard (868 MHz, bidirectional) Mains-powered AC 2 V (with external power pack) Use For integration into the Siemens Synco living system Extending and ensuring RF coverage in the Siemens Synco living system Especially suited for: Renovation projects (old buildings, museums, churches, historical buildings, etc.) Difficult wall-mounting situations (sandstone, glass, etc.) New houses and buildings CE1N2704en 15.01.2009 Building Technologies

Equipment combinations The RF repeater is designed for use with the Siemens Synco living system. For more detailed information about equipment combinations, refer to the Data Sheet covering the central apartment unit (CE1N2707en). Ordering When ordering, please give quantity, product name and type reference. Scope of delivery Each ERF910 is supplied complete with power pack, fixing material and Mounting Instructions. Product documentation The Operating and Commissioning Instructions for the ERF910 are contained in the product documentation of the central apartment unit. Functions Main function Binding Status query RF binding test Supply state Error and maintenance messages In operation, the ERF910 repeats the RF telegrams from the devices attuned to it. The binding is used by the ERF910 to sign on at the central apartment unit, thus ensuring integration into the RF system. The binding process is triggered via the multifunction button. It is indicated by the multifunction LED. The multifunction button can be used to query the state of power supply. Availability of power is indicated by the multifunction LED. The multifunction button can be used to trigger a binding test. This test is made to check the radio link to the central apartment unit. The test is indicated by the multifunction LED. After triggering the binding test, delivery of the RF telegrams is indicated for 2 hours by the multifunction LED. The multifunction button can be used to reset the ERF910 to the default state as supplied. Then, the ERF910 must be reintegrated into the system. All error and maintenance messages are forwarded to the central apartment unit where they appear on the display. The following error messages are delivered by the ERF910: Error messages Communication error (no communication for one hour) 2 / 6

Operating and indicating elements Multifunction LED Multifunction button 2704Z01 Overview of functions of the indicating and operating elements of the ERF910: Multifunction LED Power supply Binding process Delivery of RF telegrams Multifunction button Status query power supply RF binding test Binding Disconnect device from the system Restoring the supply state For more detailed information about the functions and operation of the ERF910, refer to the product documentation covering the central apartment unit. Notes on engineering and operation Mounting location To ensure optimum operation of the ERF910, the following conditions must be observed: The ERF910 must be mounted inside the house or building, close to a power outlet (connecting cable of power pack: 3 m) The permissible environmental conditions must be observed ERF910 and power pack must not be exposed to dripping water For notes relating to engineering and mounting RF devices of the Siemens Synco living system, refer to Data Sheet CE1N2708en. The base must be fitted on a flat wall Minimum clearance at the bottom should be 60 mm to ensure that the repeater s cover can be easily opened 60 mm 2704Z02 3 / 6

There must be sufficient clearance by the power outlet to ensure that the power pack can be easily plugged in and removed 150 mm 2704Z03 Installation Commissioning Maintenance Disposal Note Mounting with the base: The ERF910 can be fitted to most commercially available recessed conduit boxes or directly on the wall. Mount the ERF910 first and then plug in the power pack. Prior to commissioning, check to ensure that the ERF910 is correctly fitted to the wall and that the power pack is correctly connected. The ERF910 is maintenance-free. In terms of disposal, the ERF is classified as electronic scrap conforming to the European Directive 2002/96/EG (WEEE) and must not be disposed of as domestic waste. The relevant national legal regulations must be complied with. The unit must be disposed of through the relevant channels. Local and currently valid legislation must be observed. Warranty Application-related technical data are only warranted in connection with the Siemens Synco living system. For equipment combinations, refer to the Data Sheet of the central apartment unit. When using the ERF together with third-party devices, correct functioning must be ensured by the user. In that case, Siemens will assume no responsibility for service and warranty. 4 / 6

Technical data power pack Type Operating voltage primary side Rated voltage secondary side Rated current secondary side Length of prefabricated connecting cable AC 2 V, 50 Hz AC 7.5 V 100 ma 3 m Technical data ERF910 Power supply Power consumption max. 0.2 VA RF Frequency Range Protocol 868 MHz (bidirectional) typically m inside buildings KNX RF compatible Electrical connections Screw terminals for 1.5 mm 2 (connections interchangeable) Standards Protection Environmental compatibility conformity to EMC directive - Immunity, Emissions Low-voltage directive - Electrical safety RTTE (Radio & Telecom. Equipment) - Wireless communication Safety class III to EN 607 Housing IP40 1) to EN 60529 Degree of pollution 2 to EN 607 Environmental product declaration CE1E2704en provides information on environmentally compatible product design and assessment (RoHS compliance, composition of substances, packaging, environmental benefit and disposal) 2004/108/EC - EN 61000-6-1, EN 61000-6-3 2006/95/EC - EN 60950-1 1999/5/EC - EN 0220-2, EN 1489-1, EN 1489-3 ISO 14001 (Environment) ISO 9001 (Quality) SN 36350 (Environmentally compatible products) 2002/95/EC (RoHS) Dimensions Weight Housing material Housing color Unit complete with accessories refer to Dimensions 0.384 kg plastic ASA+PC white NCS S 0502-G Environmental conditions operation transport storage EN 60721-3-3 EN 60721-3-2 EN 60721-3-1 Climatic conditions class 3K5 class 2K3 class 1K3 Temperature 0 +50 C -25 +70 C -20 +65 C Humidity 5 95 % r.h. <95 % r.h. 5 95 % r.h. (noncondensing) Mechanical conditions class 3M2 class 2M2 class 1M2 Elevation above sea level min. 700 hpa, corresponding to max. 00 m above sea level 1) Completely mounted 5 / 6

Connection diagram Power pack ERF910 1 AC 2 V 2 2704A01 The connections are interchangeable Dimensions Dimensions in mm ERF910 22 mm 1 mm 84 mm 2701M01a 42 42 28 28 TOP 42 2702M01 76 mm 84 mm 28 28 12 4,2 42 Power pack 74 55 44,5 2704M01 45 6 / 6 2006-2009 Siemens Switzerland Ltd Subject to change