SAFETY PRECAUTIONS CAUTION WARNING CAUTION. Thank you for purchasing ig5a Series Profibus Communication Module

Similar documents
SAFETY PRECAUTIONS CAUTION. WARNING Improper operation may result in serious personal injury or death.

Before using the product, thank you for using our Ethernet module board. Safety Instruction

SAFETY PRECAUTIONS CAUTION. WARNING Improper operation may result in serious personal injury or death.

Before using the product, thank you for using our MDLV-HP Pulse Encoder Interface Option Module. Safety Instruction

Thank you for purchasing ig5a Series DeviceNet Communication Module SAFETY PRECAUTIONS

Safety Instruction. This symbol indicates the possibility of injury or damage to property.

Safety PRECAUTIONS. Danger may be present. Read the message and follow the instructions carefully.

User Manual. RS485 Option Board for SV-iS5/iH Series. LG Industrial Systems

Before using the product, thank you for purchasing SV-iS7 DeviceNet option board. SAFETY PRECAUTIONS

SAFETY PRECAUTIONS. Throughout this manual we use the following two illustrations to make you aware of safety considerations:

User Manual. RNet Option Board SV-iS7 Series. LS Industrial Systems

Before using the product, thank you for purchasing MDLV-HP DeviceNet option board. SAFETY PRECAUTIONS

Before using the product, thank you for purchasing SV-iS7 CANopen option board. SAFETY PRECAUTIONS

CAUTION. WARNING Improper operation may result in serious personal. CAUTION Improper operation may result in slight to medium

over time. Improper wiring practices could result in drive malfunction due to loose terminal connections. Control Circuit Terminal Block Functions Dri

ABB Drives. User s Manual. Modbus Adapter Module RMBA-01

HITACHI. EH-150 series PLC EH-RTD8 Resistance Temperature Detective input module Instruction manual. Safety precautions

Installation and Setup. In This Chapter... Installing the H0 PSCM The Profibus Network Configuring the Module

Preface. Copyright 1997, Digital Electronics Corporation MS-DOS and Windows 95 are registered trademarks of the Microsoft Corporation.

User Manual. PROFIBUS-DP Option Board for SV-iS5 Series. LG Industrial Systems

PROFIBUS DP Interface Option "OPC-E1-PDP"

PROFIBUS-DP. Installation Manual. YASKAWA AC Drive Option PROFIBUS-DP

1) Examine exterior of package for signs of damage. Report any damage to shipping carrier.

GRAPHIC DIGITAL INDICATOR with PROFIBUS Interface CSD-912B-70. Instruction Manual EN

H Series PLC. ! : Indicates Compulsion. EH-150 Analog input module EH-AXH8M Instruction manual. Safety precautions DANGER CAUTION COMPULSION

YASKAWA AC Drive Option PROFIBUS-DP. Technical Manual

Safety PRECAUTIONS. Danger may be present. Read the message and follow the instructions carefully.

Installation and Setup

SK CU4-PBR-C Part number:

Before using the product, thank you for purchasing SV-iP5A CANopen option board. SAFETY PRECAUTIONS

The following conventions are used to indicate precautions in this manual.

Copyright: December 2017 Nidec Issue: E

User manual. MODBUS-RTU SV-iC5

Operator Manual for Profibus

RS485 MODBUS Module 8I8O

Profibus DP Interface Option "OPC-E1-PDP"

Profibus DP Expansion Board

ABB Drives. User s Manual Modbus Adapter Module FMBA-01

CEM M-RS485 INSTRUCTION MANUAL (M014B A)

SDM-6RO. Expansion Module 6 relay outputs. Manufactured for

Operating Manual. DMX Relay Card 3002R

MICRO-SCREEN DIN Controllers with DeviceNet Trip Output

SK TU4-PBR Part number:

Before using the product, thank you for using our MD100G Ethernet option module Safety Instruction

Installation Instructions

RS485 MODBUS Module 16I-M

RS485 MODBUS Module 6RO

MT8050iE series. Installation Instruction (1) (2)

Connection and configuration of a CDP with KACO NEW ENERGY inverters

Resolver to Digital Expansion Board

RDM172 Remote Display Module QUICK GUIDE

PROFIBUS Adapter. 20-COMM-P FRN 1.xxx. User Manual

RS 485 Mini Modbus 1AO

DIGITAL INPUT/OUTPUT RELAY INTERFACE BMS-IFDD01E

SDM-8AO. Expansion Module 8 analog outputs. Manufactured for

Serial PROFIBUS Interface

RS485 MODBUS Module 8AO

DVPPF02-SL PROFIBUS DP Slave Communication Module

SDM-8I8O. Expansion Module 8 digital inputs, 8 digital outputs. Manufactured for

GRAPHIC DIGITAL INDICATOR

Making Hazardous Operations Safe and Productive

INSTALLATION INSTRUCTIONS

PROFIBUS MODULE (CB15) English Operating Instructions. Contents. Warning and Caution Notes

DeviceNet Expansion Board

PROFIBUS DP Interface Card "OPC- F1-PDP"

AMAX-2750SY Series. 32-ch AMONet RS-485 Isolated Digital I/O Slave Modules. User Manual

BENCH-TOP DIGITAL MULTIMETER INSTRUCTION MANUAL

- 15G0078B110 - PROFIBUS MODULE INSTRUCTIONS FOR ASAC-0/ASAC-1/ASAB

USER MANUAL VIBRATION CONTROL RMA-POWER-BOX 107/230

RS485 MODBUS Module 8I8RO

Analog Input Installation Manual

Table of Contents Product Overview Before using the product Installation Procedure... 5

Digital ac/dc (24V) Input Module

BNI PBS Z001 BNI PBS Z001 BNI PBS Z001. Quick start guide

MPCR Series DeviceNet Technical Manual TDMPCRDNTM2-0EN 01/08 Subject to change without notice

FACTORY AUTOMATION MANUAL WCS-MBG110 WCS MODBUS RTU INTERFACE MODULE

Profibus DP Expansion Board

Digital DRIVE for Brushless motor MD Serial

SAFETY PRECAUTIONS. Always follow safety instructions to prevent accidents and potential hazards from occurring.

2 Table of Contents 1. TABLE OF CONTENTS. 1. Table of Contents Introduction Wiring Diagram Terminals Review...

User Manual Revision English

270 MHz Control Modules

Table of Contents 1 ABOUT THIS DOCUMENT GENERAL COPYRIGHT INFORMATION TERMS ABOUT THE GATEWAY PRODUCT FUNCTIO

BNI PBS Z001. IP67 module, Profibus IO-Link Master Short Guide

It is the installer's responsibility to follow all instructions in this manual and to follow correct electrical practice.

ADC7520 SERIES. 1600W Battery Chargers and Power Supplies

Multi-instrument Communication, MIC-2 MKII DIN Quick Start Guide

PS/IO Circuit Board Retrofit

CHAPTER MAINTENANCE AND TROUBLESHOOTING. In This Chapter... Maintenance and Inspection Troubleshooting...6 3

GENERAL PRECAUTIONS GENERAL DESCRIPTION... 6

G3 Series PROFIBUS DP Technical Manual

Serial Data DIN Fiber Link System

DCS-E 1kW Series, DLM-E 3kW & 4kW Power Supplies

Operation manual. HDOM-Profibus-V0. More options please visit;

Observe all necessary safety precautions when controlling the soft starter remotely. Alert personnel that machinery may start without warning.

[ ACD-NA ] User s Manual. O-Sung Electric Machinery Co., Ltd. 136, Hataemal-gil, Wollong-Myeon Paju-si, Gyeonggi-do, Korea

MU110-6U. Analog output module 6 channel. User guide

Operation Manual. Fieldbus system EX510-GPR1. PROFIBUS DP Compatible GW unit

1) Examine exterior of package for signs of damage. Report any damage to shipping carrier.

ATS CONTROLLER [ ACD-III ], [ ACD-III-C ] User s Manual. O-Sung Electric Machinery Co., Ltd.

Transcription:

SAFETY PRECAUTIONS Thank you for purchasing ig5a Series Profibus Communication Module SAFETY PRECAUTIONS Always follow safety instructions to prevent accidents and potential hazards from occurring. Safety precautions are classified into WARNING and CAUTION and their meanings are as follows: WARNING CAUTION Improper operation may result in serious personal injury or death. Improper operation may result in slight to medium personal injury or property damage. The indicated illustrations on the product and in the manual have the following meanings. Danger may be present. Read the message and follow the instructions carefully. Particular attention should be paid because danger of an electric shock may be present. Keep operating instructions handy for quick reference. Read the operating instructions carefully to fully understand the functions of the SV-iG5A series and to use it properly. CAUTION Be cautious, when handling the CMOS components of the communication module. Static may lead to malfunctioning of the product. Turn off the inverter power, when changing the communication cable. Otherwise, you may damage the module or a communication error may occur. Make sure to insert the Communication module connector to the inverter precisely. Otherwise, you may damage the module or a communication error may occur. Check the parameter unit before setting up the parameter. Otherwise, a communication error may occur. i

Table of Contents Table of Contents Chapter 1. Overview... 1 1.1What are the Benefits of Using Profibus option module?... 1 1.2Unpacking the drive... 1 Chapter 2. SV-iG5A Profibus Communication Option Module... 2 2.1Technical Data... 2 2.2Profibus Communication Option Module... 3 2.3Profibus Terminals... 4 2.4Control Terminals... 5 2.5Installation Procedure... 6 2.6Instruction for installation... 7 2.7Maximum distance according to the baudrate... 8 Chapter 3. Status Diagnostic and LED Indication... 9 3.1LED Status Indicator... 9 3.2Option Module Diagnostics according to LED status... 9 Chapter 4. Inverter Parameter... 12 4.1Profibus Communication Parameter List... 12 4.2Profibus Communication Parameters... 14 4.2.1 Communication option module name C1... 14 4.2.2 Operation setting method - drv... 14 4.2.3 Frequency setting method - Frq... 14 4.2.4 Selection of operation in lost command - I62... 14 4.2.5 Decision time for lost command - I63... 15 4.2.6 Version of Profibus option module C2... 15 4.2.7 Station ID setting C3... 15 4.2.8 LED indication for communication status C5... 16 4.2.9 The number of Para Status setting C30... 16 4.2.10 Para Status 1~8 C31~C38... 17 4.2.11 Number of Para Control setting C50... 17 4.2.12 Para Control 1~8 C51~C58... 18 4.2.13 Comm UpDate C99... 19 Chapter 5. GSD File (Electronic Data Sheets)... 20 ii

Chapter1. Overview Chapter 1. Overview This Profibus communication option module (abbreviated Profibus option module) allows a SV-iG5A inverter to be connected to Profibus network. 1.1 What are the Benefits of Using Profibus Option Module? Profibus option module allows a controlling and monitoring of inverter to be controlled via sequence program of PLC or Profibus Master Module. It helps to reduce the installation cost since multiple connections can be implemented with a communication line. In addition, the wiring is simple so installation time will be reduced and maintenance will be easier. Factory automation can be easily implemented because it can control the inverter with auxiliary devices of PLC and operates with top devices as PC, etc. 1.2 Unpacking the Drive The Profibus option module is delivered in a package that contains the following items. -. Profibus Communication Option Module (1) -. Profibus Communication Option Module User Manual (1) -. Fixing Screw M3 (2) 1

Chapter2. SV-iG5A Profibus Communication Option Module Chapter 2. SV-iG5A Profibus Communication Option Module 2.1 Technical Data Device Type Auto Baudrate Detect Synchronization Mode Freeze Mode Max. Input Length Max. Output Length Baudrate Support Modular Station Profibus DP Slave Supported mode Supported mode Supported mode 8 words 8 words 9.6K, 19.2K, 93.75K, 187.5K, 500K, 1.5M, 3M, 6M, 12M Supported Max. Module 2 Max. Connectable Number of Nodes LED Communication Connector Max. 32 nodes without repeater (including master module) 3 LEDs (ONLINE, ERR, and CPU) 5-pin removable connector Table 1 Technical Data 2

Chapter2. SV-iG5A Profibus Communication Option Module 2.2 Profibus Communication Option Module Status LED CPU Remote/Portabel KPD Connector Main Connector PNP/NPN Select Switch Fault Contactor Control Connector Terminal Resistor Select Switch Profibus Connector Figure 1 Profibus Communication Option Module Safety Connector Fault Contactor Connector 3

Chapter2. SV-iG5A Profibus Communication Option Module 2.3 Profibus Terminals 1 2 3 4 5 Figure 2 Profibus Terminals No. Signal Description 1 B1 Send/Receive data Plus 1 2 A1 Send/Receive data Negative 1 3 SH Shielded Ground 4 B2 Send/Receive data Plus 2 5 A2 Send/Receive data Negative 2 Table 2 Signal Description 4

Chapter2. SV-iG5A Profibus Communication Option Module 2.4 Control Terminals MO VR MG 24 P1 P2 CM P3 P4 V1 CM I AM FI FO CM Terminals Names of Terminal Electrical Information P1 ~ P4 Multi-function input terminal 1-4 - CM Common terminal - VR V1 I SA SB SC Power supply for Aux. volume resistor Voltage input terminal Current input terminal Output voltage: 12V Max. output current: 10mA Volume resistor: 1 ~ 5 kω Max. input voltage: -10V ~ +10V input 0 ~ 20mA input Internal resistor: 250 Ω Max. output voltage: 11[V] Max. output current: 10mA AM Multi-function analog output terminal MO Multi-function terminal (Open Collector) Below DC 26V, 100mA MG Aux. power supply common terminal - 24 Aux. 24V power supply Max. output current: 100mA 3A Multi-function relay output A Below AC 250V, 1A 3B Multi-function relay output B Below DC 30V, 1A 3C Multi-function relay common terminal - FI Pulse input terminal 0 ~ 50kHz FO Pulse output terminal 0 ~ 7 SA Safety input command A - SB Safety input command B - SC Safety Power Supply Max. output current: 10mA Table 3 Control Terminals Information Note 1) Tie the control wires more than 15cm away from the control terminals. Otherwise, it interfere the reinstallation of front cover. Note 2) Use copper wire rated 600V, 75 and higher. 5

Chapter2. SV-iG5A Profibus Communication Option Module 2.5Installation Procedure Remove the front cover (2, 3) of ig5a for Europe. Connect the Profibus option module (4) on the inner cover (5) of inverter. Mount the upper front cover (2) after connecting the profibus option module (4). Connect the communication and I/O signal cable to control the inverter. Fasten the screw on the upper front cover (3) after connecting cables. Profibus option module needs the Portable keypad (6) or Remote keypad for monitoring since the module is non-loader type. Step 1 Step 2 Step 3 2 1 3 5 4 Step 4 Step 5 6 Figure 3 Installation Steps 6

Chapter2. SV-iG5A Profibus Communication Option Module 2.6 Instruction for installation Warning) Make sure that connect Profibus option module after inverter power is disconnected. Do not install or remove Profibus option module while the power is ON. Otherwise, both Profibus option module and the inverter may be damaged. Install or remove Profibus option module when the condenser of the inverter has been fully discharged. When building a network, make sure to connect the termination resistor to reduce the noise at Profibus option module at the end of the network. Turn on the termination resistor switch on Profibus option module. Termination resistor 220 Ω and 1/8W will be connected between A1 and B1. Termination Switch OFF Termination Switch OFF Node 2 Node N - 1 Node 1 Node N Termination Resistor Switch ON 22 0 ohm 1/8 W Figure 4 Termination Resistor Termination Resistor Switch ON 22 0 ohm 1/8 W 7

Chapter2. SV-iG5A Profibus Communication Option Module 2.7 Maximum Distance according to the Baudrate Total BUS length of network is differed according to the baudrate. The communication is not guaranteed if the total distance exceeds the total BUS length. Baudrate Max. Segment Length Max. Extension Distance 12 Mbps 1,000 m / 3,278 feet 10,000 m / 32,786 feet 6 Mbps 1,000 m / 3,278 feet 10,000 m / 32,786 feet 3 Mbps 1,000 m / 3,278 feet 10,000 m / 32,786 feet 1.5 Mbps 1,000 m / 3,278 feet 10,000 m / 32,786 feet 500 kbps 400 m / 1,311 feet 4,000 m / 13,114 feet 187.5 kbps 200 m / 655 feet 2,000 m / 6,557 feet 93.75 kbps 100 m / 327 feet 1,000 m / 3,278 feet 19.2 kbps 100 m / 327 feet 1,000 m / 3,278 feet 9.6 kbps 100 m / 327 feet 1,000 m / 3,278 feet Table 4 Maximum Distance according to the Baudrate 8

Chapter3. Status Diagnostic and LED Indication Chapter 3. Status Diagnostic and LED Indication 3.1 LED Status Indicator Profibus Option Module have 3 kinds of LED. Refer to following table for troubleshooting information provided by there LEDs. LED Status Description CPU ERR ONLINE Steady (On) Steady (On) Steady (On) Power supply on the module OK after mounting the option module on the inverter. Module has a fault. Module is online. Table 5 LED Indication 3.2 Diagnostics according to LED status Option LED LED Module Cause Status Status CPU OFF Blinking every second Power supply fault Normal ERR OFF Normal No power supply or connection fault between inverter and Profibus option module Normal operation Normal operation Corrective Actions Check power supply. Check fault function of inverter. Check connector connection between Profibus option module and inverter. - - 9

Chapter3. Status Diagnostic and LED Indication ERR ON- LINE Blinking every second with CPU LED Blinking every 2 seconds Blinking every 3 second OFF Communication error with inverter CONFIG ERROR Configuration information changed Off-Line Communication is not available between inverter and option module. Configuration Data is incorrect setting between Master and Inverter. Station ID, number of Status, and number of Control value is changed by Keypad. Communication is not started from master. Communication connector has a fault. There is no master in the network. Check fault function of inverter. Check connector connection between Profibus option module and inverter. Check configuration information set in master and inverter. Perform Comm Update or reset the inverter if Station ID (C 3), number of Status (C 30), and number of Control (C 50) are changed. Start the communication from Master. Check the connection between pin number of connector and termination resistor. There is no designated master or master has a fault. 10

Chapter3. Status Diagnostic and LED Indication ON On-Line Wrong Station ID Network Configuration Fault IO Data Exchange state Table 6 Diagnostics according to LED Status Check the station ID between designated Profibus option module station ID set in configuration tool and station ID set in keypad of inverter. In addition, check that station ID is unique in the network. Check that it exceeds max. length of segment. Check that number of station exceeds 32 stations including repeater in a segment. Check that the number of station exceeds 126 stations including repeater in a network. - 11

Chapter4. Inverter Parameter Chapter 4. Inverter Parameter 4.1 Profibus Communication Parameter List Code drv Frq C 1 Name of Parameter Operation Setting Method Frequency Setting Method FieldBus Option Name Default Value 1. Fx/Rx- 1 0. Keypad- 1 Range Description 0. Keypad Select No.4 FieldBus if you 1. Fx/Rx-1 want to command the operation of inverter via 2. Fx/Rx-2 Profibus. 3. RS485 4. FieldBus 0. Keypad-1 Select No.9 FieldBus if you want to command the frequency of inverter via Profibus. 1. Keypad-2 2. -10~10V 3. 0~10V 4. 0~20mA 5. "2" + "4" 6. "3" + "4" 7. RS485 8. Digital Volume 9. FieldBus 10. Pulse - - PnEt is indicated when Profibus option module is mounted. C 2 Comm. Option Module Version - - S/W version of Profibus option module is indicated. 12 C 3 Station ID Setting C 5 FBus LED - - 1 1 ~ 125 - LED status of Profibus option module is displayed.

Chapter4. Inverter Parameter C30 Number of Para Status Setting 3 0~8 Table 7 Inverter Parameters Set the number of Status used. C31 Para Status-1 h000a 0~hFFFF Set the address of status C32 Para Status-2 h000e 0~hFFFF read from Profibus master. C33 Para Status-3 h000f 0~hFFFF C34 Para Status-4 h0000 0~hFFFF C35 Para Status-5 h0000 0~hFFFF C36 Para Status-6 h0000 0~hFFFF C37 Para Status-7 h0000 0~hFFFF C38 Para Status-8 h0000 0~hFFFF Number of Set the number of Control. C50 2 0~8 Para Control C51 Para Control-1 h0005 0~hFFFF Set the address of control C52 Para Control-2 h0006 0~hFFFF C53 Para Control-3 h0000 0~hFFFF C54 Para Control-4 h0000 0~hFFFF C55 Para Control-5 h0000 0~hFFFF C56 Para Control-6 h0000 0~hFFFF C57 Para Control-7 h0000 0~hFFFF C58 Para Control-8 h0000 0~hFFFF Comm Update 0. No C99 I62 I63 Selection of Operation in Lost Command Decision Time for Lost Command 0. No 0. None 1.0 sec 1. Yes controlled by Profibus master. Use when comm. update Profibus option module. 0 is displayed automatically after comm. update if C99 set to 1. 0. None Set the inverter operation 1. Free-Run when Lost Command is 2. Dec occurred. 0.1 ~ 120.0 sec Set the decision time for Lost Command. 13

Chapter4. Inverter Parameter 4.2 Profibus Communication Parameters 4.2.1Communication option module name - C 3 FBus ID It displays the name of option module installed on the inverter. It displays PnEt when Profibus option module is installed correctly and it has no fault. 4.2.2 Operation setting method - drv It sets the operation setting method of inverter. To control inverter operation through Profibus communication, set drv to 4. 4.2.3 Frequency setting method - Frq It sets the frequency setting method of inverter. To control inverter frequency through Profibus, set Frq to 9. 4.2.4 Selection of operation in lost command - I62 drv Frq I62 I63 Operation setting method Frequency setting method Selection of operation in Lost Command Decision time for Lost Command It designates operation method when communication is lost during decision time for Lost command. To use this function, drv have to be set to 4 (FieldBus) or Frq to 9 (FieldBus). Selection of operation in Lost Command 0 (None) Continuing operation 1 (FreeRun) Free run to stop 2 (Stop) Deceleration to stop 14

Chapter4. Inverter Parameter 4.2.5Decision time for lost command - I63 To use this function, drv have to be set to 4 (FieldBus) or Frq to 9 (FieldBus). drv Frq I62 I63 Operation setting method Frequency setting method Selection of operation in Lost Command Decision time for Lost Command If communication restarts in a decision time of Lost Command, it is not recognized for error. (1) Communication Status Lost Command Lost Command Decision time for Lost Command Decision time for lost Command 1 Recognition of Lost Command Figure 5 Lost Command Recognition 4.2.6 Version of Profibus option module C2 It displays the version of Profibus option module installed on the inverter. 4.2.7 Station ID setting C3 C3 C99 Station ID setting Comm Update It sets Station ID of Profibus option module. It can set station ID from 1 to 125. Station ID cannot be duplicated. Check if Station ID is not 15

Chapter4. Inverter Parameter duplicated in the network. If station ID is changed, ERR LED on the Profibus option module is flickered every 3 seconds. The number of changed Para Control must be applied to Profibus option module. Set C99 (Comm Update) to 1 when Station ID had been changed. 4.2.8 LED indication for communication status C5 Profibus communication option module have 3 LEDs, (blank), ONLINE, ERR, and CPU, on the keypad in order from left to right. It indicates communication status by On/Off. C5 Status Example) 0101 - LED type Keypad Value Blank ON-LINE (Green) ERR (Red) CPU (Green) 0 1 0 1 Status Reserved ON OFF ON 4.2.9 The number of Para Status setting C30 C30 Number of Para Status setting C31~C38 Para Status1~Status8 setting This parameter determines that inverter sends how many status information to master through Profibus communication. It can set the number from 0 to 8. Para Status has to be set as the number of Para Status. (from C31 to C38 as preset number) For example, If C30 sets to 3, Para Status set from C31 to C33. If C30 sets to 6, Para Status set from C31 to C36. If C30 (the number of Parameter status) is changed, ERR LED on Profibus option module is flickered every 3 seconds. If Number of Para Status setting is changed, set C99(Comm Update) to 1 to apply the changed number of Para Status to Profibus option module. 16

Chapter4. Inverter Parameter 4.2.10 Para Status 1~8 C31~C38 C30 Number of Para Status setting C31~C38 Para Status1~Status8 setting It determines that what status information will be sent to master through Profibus communication. Para Status 1~8 sets with the type of inverter address. The address is for inverter common area and inverter keypad parameter. If keypad parameter address is used, it will be inputted the type of (h0a x h1000) + ( Group number x h100) + ( Code number ). For example, if maximum frequency of No. 21 at F group set to Para Status-1, it has to be set to ha215. h0a x h1000 + h02 x h100 + h15(dec 21) = ha215 Group Group Number DRV 1 F 2 H 3 IO 4 COM 5 4.2.11 Number of Para Control setting C50 C50 Number of Para Control setting C51~C58 Para Control 1 ~ Control 8 setting C99 Comm Update It determines that master sends how many control information to inverter through Profibus communication. It can set the number from 0 to 8. Para Control has to be set as the number of Para Control. (From C51 to C58 as preset number) For example, If C50 sets to 2, Para Status set from C51 to C52. If C50 sets to 5, Para Status set from C51 to C55. 17

Chapter4. Inverter Parameter If C50 (the number of Para Control) is changed, ERR LED on Profibus option module is flickered every 3 seconds. If Number of Para Control setting is changed, set C99(Comm Update) to 1 to apply the changed number of Para Control to Profibus option module. 4.2.12 Para Control 1~8 C51~C58 C50 Number of Para Control setting C51~C58 Para Control 1~Control 8 setting It determines that what control information will be sent to inverter through Profibus communication. Para Control 1 ~ 8 sets with the type of inverter address. The address is for inverter common area and inverter keypad parameter. If keypad parameter address is used, it will be inputted the type of (h0a x h1000) + ( Group number x h100) + ( Code number ). For example, if maximum frequency of No.34 at IO group set to Para Control-1, it has to be set to ha422. h0a x h1000 + h04 x h100 + h22 (Dec 34) = ha422 Group Group Number DRV 1 F 2 H 3 IO 4 COM 5 18

Chapter4. Inverter Parameter 4.2.13 Comm UpDate C99 C3 C30 C50 C99 Station ID setting The number of Para Status setting The number of Para Control setting Comm UpDate After changing Station ID, the number of Para Status, and the number of Para Control, set the Comm Update to 1. The changed value will be applied to Profibus option module after Comm Update. 19

Chapter 5. GSD File Chapter 5. GSD File (Electronic Data Sheets) It contains the information of Profibus option module. The profibus configuration software needs GSD file. You can download GSD file from technical support in LSIS website. (http://eng.lsis.biz) 20

Warranty Warranty Maker Model No. Customer Information Sales Office (Distributor) LS Industrial Systems Co., Ltd. Installation Date SV-iG5A Warranty Profibus Communication Period Option Module Name Address Tel. Name Address Tel. Warranty period is 12 months after installation or 18 months after manufactured when the installation date is unidentified. However, the guarantee term may vary on the sales term. IN-WARRANTY service information If the defective part has been identified under normal and proper use within the guarantee term, contact your local authorized LS distributor or LS Service center. OUT-OF WARRANTY service information The guarantee will not apply in the following cases, even if the guarantee term has not expired. Damage was caused by misuse, negligence or accident. Damage was caused by abnormal voltage and peripheral devices malfunction (failure). Damage was caused by an earthquake, fire, flooding, lightning, or other natural calamities. When LS nameplate is not attached. When the warranty period has expired. A