HZS 352 Touch Room Unit

Similar documents
HZS 351 Room Touch Control Panel

ETT 352 Touch Operating Panel

ETT 312 Build-In Touch Terminal

TAE 1921 Touch Display Unit

TAE 1921 Touch Display Unit

ICA 012 S-DIAS Interface Module CAN

ISE 021 S-DIAS Interface Module RS232 / RS485

KL 181 S-DIAS +24 V Potential Distributor Module

TO 161 S-DIAS Digital Output Module

DM 161 S-DIAS Digital Mixed Module

TSY 041 Training System Extension Motion

AO 081 S-DIAS Analog Output Module

RO 051 S-DIAS Relay Output Module

SI 021 S-DIAS SSI Interface Module

VI 021 S-DIAS VARAN Control Module

PS 101 S-DIAS Power Supply Module

HZS Internal Controller Expansion

SE 051 S-DIAS Splitter Ethernet

AI 046 S-DIAS Analog Input Module

Connection Cables for Operating Devices

PC 521 Data Recording PC

ETT 412 Touch Operating Panel Technical Manual

ETT 731 Build-in Terminal Touch

Expansion Module HZS 541-1S

HZS 772 Touch Operating Panel

MDM 011-Z1 Regen Resistor

ETT 771 Build-in Touch Terminal

C-DIAS Serial Interface CSI 021

ETT 732 Touch Operating Panel

DC S-DIAS Axis Module

VARAN Splitter Module VSV 043

1 Safety instructions. 2 Device components. 3 Function. Smart Control IP. Art. No. SC 1000 IP. Operating instructions

Keyboard Unit Sigmatek

HZS Solar Module

VARAN Splitter PROFINET VSP 042

PC 400 Control Cabinet PC

C-DIAS Digital Input Module CDI 161 with 16 inputs

IP Address Settings Quick Guide

VARAN Bus Coupler Module VBC 021 For connecting two VARAN bus systems

HZS 771 Touch Operating Panel

ISOMETER isoev425 with coupling device AGH420

F1000 User's Manual. (Version: V1.01)

TOP - 1. Instruction Manual. Version 1.0 Produced in Jan. 2004

Operating Instructions 12/2010 MN Z-EN XV-152 MICRO PANEL

Control Panel CP600-eCo CP604, CP604-B

AP 701 Access Panel. Features and Functions

IGLOO IGLOO EASY INSTRUCTION MANUAL

IGLOO IGLOO EASY INSTRUCTION MANUAL

Device technology. Supply Bus voltage V DC. Current consumption via bus. Accuracy in the range 300 1,000 ppm 1,000 2,000 ppm 2,000 5,000 ppm

Control Panel CP600 CP651, CP651-WEB

VARAN Splitter PROFINET VSP 044

VARAN Splitter Module VSV 041

User Manual. Rack Mount Display Monitor - 4K RMP-161-4K17. 7U 17.3 inch Rack Mount Display Monitor

Technical Data. C-DIAS-MULTI l/o MODULE CIO 013

Protected VARAN Digital Mixed Module PVDM 086

Control Panel CP600 CP635, CP635-B, CP635-WEB

LCD MODULE SPECIFICATION. Model : CT57M3224A _ - Revision 01 Engineering Jackson Fung Date 22 July 2016 Our Reference

DTP170. Colour Touch Screen Installation Manual. contents

Technical Data Sheet OPUS A3 STANDARD Basic

Control Panel CP600 CP635-FB, CP635-FW

ISOMETER isoev425/isoev425hc with coupling device AGH420

User Manual. Rack Mount Display Monitor RMP-161-F17A. 6U 17.3 inch Rack Mount Display Monitor. Options : - AV, S-video input - Touchscreen

EX-RC1 Remote I/O Adapter

27 Industrial Chassis Monitor

2 Device description. 2 Device description 2.1 Function. 2.1 Function. 2.2 Intended use. 2.3 Device versions

Room unit with PPS2 interface

PRELIMINARY. USB1 / USB2 USB host interface to read data via memory stick. Bus Out (system bus) For connection to a router

Product Information. DCM Standard indoor stations TK IS A 514 A.. TK IS A 514 AD.. (Design)

VTPC190V / VS / VDC / VSDC

Technical Data Sheet OPUS A8 ECO Full

Profibus DP slave. dual ported RAM 2Kbyte. Maximum length for I/O data. Maximum length for output data. Status display

C-DIAS EtherNet/IP Slave CIP 022

RS-FS-N01 Wind speed transmitter user's Guide (485type)

EX-RC1 Remote I/O Adapter

Technical Data Sheet OPUS A8 ECO Basic

Auxiliary Board MP-Bus HZS 562

EX-RC1 Remote I/O Adapter

Temperature controller Ducted systems

SCHOTT FLM 4 Fiber Lighting Modul. Operating Instructions

RXTH DUAL ROOM SENSOR / SWITCH

C-DIAS-Temperature Recording module CAI x Temp. inputs 50 C to +150 C

Display Panel BAT 100 LSN. en Operation Guide

Product and Applications Description. Example of Operation. Installation Instructions WARNING. Note. Application Programs

MVS RAIL ELECTRONIC FAN SPEED CONTROLLER. Mounting and operating instructions

Installation and Operation Guide

MU110-6U. Analog output module 6 channel. User guide

Technical Data Sheet OPUS A6 ECO Full

1. Safety Precautions (Read these precautions before use.)

EY-RU 355: Room operating unit, ecounit355

RST ROOM TEMPERATURE TRANSMITTER. Mounting and operating instructions

HARDWARE MANUAL ENGLISH

USER MANUAL. User Manual 17 / 19 LCD. NVP117 / NVP119 1U LCD Console Drawer. Options : - AV / DVI-D / HDMI / Audio - Full Range KVM - DC power

Operating Manual UMB ISO Converter ISOCON Order Number: 8160.UISO

Room unit with PPS2 interface

1. PRODUCT INTRODUCTION Description 1-2. Feature...

VARAN Manager PCI Insert module PCV 521 Versatile Automation Random Access Network

15 TFT-LCD Monitor Operation Manual

C-DIAS Analogue Output Module CAO 082 for eight ±10V DC respectively eight 0 20mA DC outputs

CAN Repeater CAN-CR200, CAN-CR220, CAN-CR210/FO

Technical Data Sheet OPUS A6 ECO Basic

Transcription:

HZS 352 Touch Room Unit Date of creation: 25.04.2014 Version date: 25.03.2016 Article number: 06-895-352-E

Publisher: SIGMATEK GmbH & Co KG A-5112 Lamprechtshausen Tel.: 06274/4321 Fax: 06274/4321-18 Email: office@sigmatek.at WWW.SIGMATEK-AUTOMATION.COM Copyright 2014 SIGMATEK GmbH & Co KG Translation from German All rights reserved. No part of this work may be reproduced, edited using an electronic system, duplicated or distributed in any form (print, photocopy, microfilm or in any other process) without the express permission. We reserve the right to make changes in the content without notice. The SIGMATEK GmbH & Co KG is not responsible for technical or printing errors in the handbook and assumes no responsibility for damages that occur through use of this handbook.

TOUCH ROOM UNIT HZS 352 Touch Room Unit HZS 352 The HZS 352 is an intelligent terminal for programming and visualization of automated processes. As a room-operating device, the terminal is equipped with temperature sensor. A resistive touch screen serves as the input medium for process data and parameters. The output is shown on a 3.5" TFT color display. To save energy, the display is deactivated in sleep mode. When the screen surface is touched, the terminal is activated and then deactivated a few minutes after the last input. With the LSE mask editor, graphics can be created on the PC, then stored and displayed on the terminal. Data is exchanged over a CAN bus. The two-part HZS 352 is mounted on the wall in a flush-mounted box or mounted in a panel via the screw bosses in the corner of the operating terminal. 25.03.2016 Page 1

HZS 352 TOUCH ROOM UNIT Contents 1 Technical Data... 3 1.1 Performance Data... 3 1.2 Temperature Sensor:... 3 1.3 Electrical Requirements... 3 1.4 Terminal... 4 1.5 Environmental Conditions... 4 1.6 Display... 5 1.7 Miscellaneous... 5 2 Mechanical Dimensions... 6 3 Connector Layout... 7 4 Mounting Instructions... 9 4.1 Wall Mounting... 9 4.2 Panel Mounting... 10 5 CAN Bus Setup... 12 5.1 CAN Bus Station Number... 12 5.2 Number of CAN Bus Participants... 12 5.3 CAN Bus Data Transfer Rate... 12 6 CAN Bus Termination... 13 7 Cleaning the Touch Screen... 14 Page 2 25.03.2016

TOUCH ROOM UNIT HZS 352 1 Technical Data 1.1 Performance Data SDRAM Flash Interfaces Terminating resistor Data rate Display Resolution Control panel 8-Mbyte 1-Mbyte 1x CAN bus (fixed terminal strip) 120 settable with DIP-Switch maximum 1 Mbit/s 3.5" TFT color display 320 x 240 Pixel 4-wire touch screen (analog resistive) 1.2 Temperature Sensor Number 1 Resolution 12-bit Temperature resolution 0.1 C Accuracy ±0.5 C Temperature measurement range 0... +50 C 1.3 Electrical Requirements Supply voltage +18-30 V DC Current consumption typically 50 ma maximum 100 ma 25.03.2016 Page 3

HZS 352 TOUCH ROOM UNIT 1.4 Terminal Operating unit dimensions 93.3 x 93.3 x 12.1 mm (W x H x D) Installation depth of supply in a flush-mounted box. Installation measurements with panel mounting Material 29 mm (installation of supply in flush-mounted box D = 65 mm) in accordance with ÖNORM E8606-1 52 x 52 x 30 mm (W x H x D) Corner hole clearance 81.3 plastic color: RAL9010 Weight circa 120 g 1.5 Environmental Conditions Storage temperature -10... +70 C Operating temperature 0... +55 C Humidity 10-80 %, non-condensing EMV product norm EN 61000-6-1 EMC stability EMC stability according to EN 61000-6-2 (industrial area) according to EN 61000-6-3 (living area) Protection type EN 60529 supply unit installed in flush-mounted box complete unit installed mounting in a panel IP20 IP30 IP30 Page 4 25.03.2016

TOUCH ROOM UNIT HZS 352 1.6 Display Type 3.5 LC graphic display Resolution 320(RGB) x 240 Pixel size Number of pixels Active surface Color depth Backlighting 0.219 x 0.219 mm 320*3 (RGB) x 240 pixels 70.08 x 52.56 mm 24 bits 6x LED, white, regulatable Contrast 400:1 Touch Brightness resistive typically 350 cd/m² Visible field left, right 70, below 70, above 60 1.7 Miscellaneous Article number 05-895-352 Hardware version 1.x 25.03.2016 Page 5

HZS 352 TOUCH ROOM UNIT 2 Mechanical Dimensions Page 6 25.03.2016

TOUCH ROOM UNIT HZS 352 3 Connector Layout 25.03.2016 Page 7

HZS 352 TOUCH ROOM UNIT X1: Supply Terminal (Weidmüller LSF-SMT 5.00/05/180 3.5SN BK TU) Pin Function 1 CAN B (HIGH) 2 CAN A (LOW) 3 n.c. 4 +24 V 5 GND n.c. = do not use Connectable Leads Wiring min. max. Connection dimensions 0.13 mm² 1.5 mm² Conductor cross-section AWG AWG 24 AWG 16 Single wire 0.2 mm² 1.5 mm² Fine-stranded with end sleeve 0.25 mm² 1.5 mm² End sleeve with collar 0.25 mm² 0.75 mm² X2: USB Device 1.1 (Type Mini-B) (for service purposes only) Pin Function 1 +5 V 2 D- 3 D+ 4 n.c. 5 GND S1: CAN Bus Termination (1-pin DIP-Switch) ON => CAN bus termination with 120 Page 8 25.03.2016

TOUCH ROOM UNIT HZS 352 4 Mounting Instructions 4.1 Wall Mounting The supply component is installed and wired in a flush-mounted box with a diameter of 65 mm. It is thereby important to ensure the flush-mounted box is mounted flush with the wall. Before installing, check whether or not the CAN bus (termination resistance switchable via the DIP switch) is required. After the electrical installation, the supply unit is mounted at the location using countersunk screws. The operating terminal is the simply inserted into the flush-mounted box. 25.03.2016 Page 9

HZS 352 TOUCH ROOM UNIT 4.2 Panel Mounting Page 10 25.03.2016

TOUCH ROOM UNIT HZS 352 The room unit is inserted through the cut-out of the panel and secured using 4 screws on the backside. Scheme 25.03.2016 Page 11

HZS 352 TOUCH ROOM UNIT 5 CAN Bus Setup This section explains how to correctly configure the CAN bus. The following parameters must first be set: Station number and data transfer rate. 5.1 CAN Bus Station Number Each CAN bus station is assigned its own station number. With this station number, data can be exchanged with other stations connected to the bus. In a CAN bus system however, each station number can only be assigned once! 5.2 Number of CAN Bus Participants The maximum number of participants on the CAN bus depends on the cable length, termination resistance, data transfer rate and the drivers used in the participants. With a termination resistance of 120, at least 100 participants are possible. 5.3 CAN Bus Data Transfer Rate Various data transfer rates (baud rates) can be set on the CAN bus. The longer the bus line is, the lower the data transfer rate that must be selected. Value Baud Rate Maximum Length 0 615 Kbits/s 60 m 1 500 kbit/s 80 m 2 250 Kbits/s 160 m 3 125 Kbits/s 320 m 4 100 Kbits/s 400 m 5 50 Kbits/s 800 m 6 20 kbits/s 1200 m 7 1 Mbit/s 30 m These values apply to the following cable: 120 Twisted Pair. Note: For the CAN bus protocol: 1 kbit/s = 1 kbaud. Page 12 25.03.2016

TOUCH ROOM UNIT HZS 352 6 CAN Bus Termination In a CAN bus system, both end modules must be terminated. This is necessary to avoid transmission errors caused by reflections in the line. The termination is made by an internal 120 resistor between CAN A (LOW) and CAN B (HIGH). 25.03.2016 Page 13

HZS 352 TOUCH ROOM UNIT 7 Cleaning the Touch Screen CAUTION! Before cleaning the touch screen, the terminal must first be turned off to avoid unintentionally triggering functions or commands! ATTENTION! Avant de nettoyer l'écran tactile, le terminal doit d'abord être éteint afin d éviter un déclanchement involontaire des commandes! The terminal's touch screen can only be cleaned with a soft, damp cloth. A screen cleaning solution such as an anti-static foam, water with a mild detergent or alcohol should be used to dampen the cloth. The cleaning solution should be sprayed onto the cloth and not directly on the terminal. The cleaning solution should not be allowed to reach the terminal electronics, for example, through the ventilation slots. No erosive cleaning solutions, chemicals, abrasive cleansers or hard objects that can scratch or damage the touch screen may be used. If the terminal comes in contact with toxic or erosive chemicals, carefully clean the terminal immediately to prevent corrosion! To ensure the optimal function of the terminal, the touch screen should be cleaned at regular intervals! Pour garantir le fonctionnement optimal du terminal, le terminal doit être nettoyé régulièrement! To extend the lifespan of the touch screen as much as possible, using the fingers to operate the terminal is recommended. Pour prolonger la durée de vie de l'écran tactile on recommande d utiliser les doigts pour l opérer. Page 14 25.03.2016

TOUCH ROOM UNIT HZS 352 Documentation Changes Change date Affected page(s) Chapter Note 18.06.2014 3 1.1 Performance Data 1.2. Temperature Sensor 1.6 Display Table updated 5 08.10.2014 3 1.3 Electrical Requirements changed to +18-30 V DC 25.03.2016 5 1.6 Display Table updated 25.03.2016 Page 15

HZS 352 TOUCH ROOM UNIT Page 16 25.03.2016