TCP305A & TCP312A AC/DC Current Probes Instructions

Similar documents
P5200A Series High Voltage Differential Probes. Installation and Safety Instructions & Product Documentation CD

RSA306B Real-Time Spectrum Analyzer Installation and Safety Instructions

RM3100 Rackmount Kit for the AFG3000 and AFG3000C Series Arbitrary Function Generators

1103 Power Supply (SN B and Above) Instruction Manual

Instructions. RM2000B Rackmount Kit

Instructions. P MHz 10X Passive Probe

Instruction Manual. CT-4 High-Current Transformer

A Amp AC/DC Current Probe Instructions

RSA306 Real-Time Spectrum Analyzer Installation and Safety Instructions

RSA306 Real-Time Spectrum Analyzer Installation and Safety Instructions

Instructions. TLA5Fxxx, TLA6Fxx, & TLA7Fxx PowerFlex Field Upgrade Kits for TLA5000, TLA600, and TLA700 Logic Analyzers

A Amp AC Current Probe Instructions

TekExpress DiiVA Automated Solution

Instructions. RM3000 Rackmount Kit for TDS3000 Series Oscilloscopes

DAS 9200 Mainframe System Upgrade

TG700 TV Signal Generator Platform PC Tools Technical Reference

TLA5Fxxx, TLA62F0x, & TLA7Fxxx PowerFlex Field Upgrade Kit Logic Analyzers Instructions

TETRIS 2500 High Impedance Active Probe. Instruction Manual

WFM520UP and WVR520UP WFM5200 Waveform Monitor and WVR5200 Waveform Rasterizer Upgrade Kit Instructions

Model P4017 Single Channel USB Oscilloscope. Quick Start Guide

P344 4-lane MIPI DPhy Stimulus Generator Data Sheet & User Manual. January Rev 1.31

PMT 201A-RO High Impedance Passive Probe. Instruction Manual

OM GHz, OM GHz Optical Modulation Analyzer Installation and Safety Instructions

Instructions. P GHz 10X Active Probe

MiniModules. Reference Manual. Series R CT 3002 V 1.0 MiniModule USB Service Adapter and Software

Contents. HP E1586A Rack Mount Terminal Panel User s Manual

Quick Start/Installation Guide

RIGOL. Quick Guide. DP800A Series Programmable Linear DC Power Supply. Aug RIGOL Technologies, Inc.

RSA5100B Series Real-Time Signal Analyzers RSA5BUP Option 300 High Performance Real Time Upgrade Instructions

KHT 6000 C HV-Probe Calibrator. Instruction Manual

General Warranty. For more details, please refer to the user manual on the supplied CD, it can also be downloaded at

DPO70000/B and DSA70000/B and Above Power Supply Replacement Kit Instructions

TDSUSBF USB 2.0 Test Fixture Socket Upgrade Kit

38 MHz Passive Voltage Probe R&S RT-ZP1X

DS1000B Series Digital Oscilloscope

DC 100 A Current Probe

and above SSD Remote Mounting Kit Instructions

PMT 221A High Impedance Passive Probe. Instruction Manual

User's Guide. Phase Sequence and Motor Rotation Tester Model

9040/9040UK. Users Manual. Phase Rotation Indicator

DC 100 A Current Probe

designed for OMICRON Lab PML 111O High Impedance Passive Probe Instruction Manual

User s Guide. RP7000S Series Single-Ended Active Probe. Nov RIGOL Technologies, Inc.

87421/22A Power Supply. Operating and Service Manual

Agilent Technologies E5339A 38-Pin Low-Voltage Probe

TLA7S08 & TLA7S16 Serial Analyzer Modules PCI Express Instruction Manual

DM3058/DM3058E Digital Multimeter

Power Quality Recorder

MFA-0801 & MFA-1201 D-M-E Smart Series Low Voltage Temperature Control System. User s Manual. D-M-E Company

, , and and above Rackmount Kits Instructions

TDS5000B Series SATA Hard Disk Drive Replacement Kit Instructions

P7313SMA Differential Probe

374 FC/375 FC/376 FC. Clamp Meter. Safety Information

50 Amp AC/DC Current Probe PA-655 INSTRUCTION MANUAL 安培交流 / 直流電流探測鉗. DC 500KHz. 5mA 50A.

SLA Battery Capacity Analyzer

P7700 Series TriMode Probes

Sentry Series Video Quality Monitors Installation and Safety Instructions

User s Guide. 600A AC Clamp Meter. Model 38387

Power Quality Recorder

Automated Tuner System Power Distribution Hub

RSA6000A Series TDS5000B Series DSA8200 Hard Disk Drive Adapter Upgrade Kit XX Instructions

GPS Synchronization Module

General Warranty. For more details, please refer to the user manual on the supplied CD, it can also be downloaded at

Keysight 42941A Impedance Probe Kit

PML 791-RO Low-Z Passive Probe. Instruction Manual

User Guide. Control Box. RoscoLED TM.

PageBot for Kindle 3. User Guide. Adaptive Switch Interface.

User's Guide. Extech AM A AC Analog Clamp Meter

USER GUIDE. AXIS T8120 Midspan 15 W 1-port ENGLISH

DSA8300 Digital Serial Analyzer TekScope and Connectivity Software Installation

RSA503A and RSA507A Real-Time Spectrum Analyzers Installation and Safety Instructions

Solar Combiner Enclosure

Economy Single Channel Output DC Power Supply

Service Manual. P GHz Active Probe

3.5 TFT LCD CCTV Service Viewer with Wristband LCD35SV

Swifty User Guide. USB Switch Interface Model: SW2.

E2K-F. Flat Capacitive Sensor with a Thickness of Only 10 mm. Flat Proximity Sensor. Ordering Information. Sensors [Refer to Dimensions on page 4.

WA4204-G2/G3 and WA4304-G2/G3

Quick Start Guide CJB1950ALAAB

Swifty User Guide. USB Switch Interface Model: SW2. Table of Contents.

User s Guide. 600A True RMS AC/DC Clamp Meter. Model 38389

DCS-E 1kW Series, DLM-E 3kW & 4kW Power Supplies

DPO-UP Upgrades for MSO70000/C/DX, DSA70000/B/C/D, DPO70000/B/C/ D/DX/SX, DPO7000/C, MSO5000/B, and DPO5000/B Series Instruments Instructions

XBDM. 1015LV, 1020LV, 1030LV, 1020HV Models USER & INSTALLATION MANUAL BYPASS DISTRIBUTION MODULE

RSA5100A Series Real-Time Signal Analyzers Declassification and Security Instructions

General Warranty. For more details, please refer to the user manual, it can be downloaded at

PP007-WR-1 PP007-WR-2 PP007-WS-1 PP007-WS-2. Operator s Manual. PP007 Passive Probe

MFP5G, MFP8G, & MFP12G D-M-E Smart Series Mainframes

Simple Logger II Series

OPERATING MANUAL LOW-VOLTAGE DISCONNECT PANELS LVD400 & LVD600 SERIES

USB 3.0 Spectra

CMSA-100 Manual. Cinema Media Server Automation

TDSPTD Protocol Trigger and Decode Application Online Help

Installation Manual. TLA700 Series Logic Analyzer

Tapio User Guide. ios and USB Switch Interface.

Visit us at

Lotus DX. sit-stand workstation. assembly and operation instructions. MODEL # s: LOTUS-DX-BLK LOTUS-DX-WHT

Mini-DVI-WP Series WALL PLATE MINIATURE MULTIMODE FIBER OPTIC DVI TRANSMISSION SYSTEM

Agilent 70612B K18 Switch Matrix

FCA3000, FCA3100, and MCA3000 Series Connectivity Installation Manual

Transcription:

xx ZZZ TCP305A & TCP312A AC/DC Current Probes Instructions www.tektronix.com *P071303200* 071-3032-00

Copyright Tektronix. All rights reserved. Licensed software products are owned by Tektronix or its subsidiaries or suppliers, and are protected by national copyright laws and international treaty provisions. Tektronix products are covered by U.S. and foreign patents, issued and pending. Information in this publication supersedes that in all previously published material. Specifications and price change privileges reserved. TEKTRONIX and TEK are registered trademarks of Tektronix, Inc. Contacting Tektronix Tektronix, Inc. 14150 SW Karl Braun Drive P.O. Box 500 Beaverton, OR 97077 USA For product information, sales, service, and technical support: In North America, call 1-800-833-9200. Worldwide, visit www.tektronix.com to find contacts in your area.

Warranty Tektronix warrants that this product will be free from defects in materials and workmanship for a period of one (1) year from the date of shipment. If any such product proves defective during this warranty period, Tektronix, at its option, either will repair the defective product without charge for parts and labor, or will provide a replacement in exchange for the defective product. Parts, modules and replacement products used by Tektronix for warranty work may be new or reconditioned to like new performance. All replaced parts, modules and products become the property of Tektronix. In order to obtain service under this warranty, Customer must notify Tektronix of the defect before the expiration of the warranty period and make suitable arrangements for the performance of service. Customer shall be responsible for packaging and shipping the defective product to the service center designated by Tektronix, with shipping charges prepaid. Tektronix shall pay for the return of the product to Customer if the shipment is to a location within the country in which the Tektronix service center is located. Customer shall be responsible for paying all shipping charges, duties, taxes, and any other charges for products returned to any other locations. This warranty shall not apply to any defect, failure or damage caused by improper use or improper or inadequate maintenance and care. Tektronix shall not be obligated to furnish service under this warranty a) to repair damage resulting from attempts by personnel other than Tektronix representatives to install, repair or service the product; b) to repair damage resulting from improper use or connection to incompatible equipment; c) to repair any damage or malfunction caused by the use of non-tektronix supplies; or d) to service a product that has been modified or integrated with other products when the effect of such modification or integration increases the time or difficulty of servicing the product. THIS WARRANTY IS GIVEN BY TEKTRONIX WITH RESPECT TO THE PRODUCT IN LIEU OF ANY OTHER WARRANTIES, EXPRESS OR IMPLIED. TEKTRONIX AND ITS VENDORS DISCLAIM ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. TEKTRONIX' RESPONSIBILITY TO REPAIR OR REPLACE DEFECTIVE PRODUCTS IS THE SOLE AND EXCLUSIVE REMEDY PROVIDED TO THE CUSTOMER FOR BREACH OF THIS WARRANTY. TEKTRONIX AND ITS VENDORS WILL NOT BE LIABLE FOR ANY INDIRECT, SPECIAL, INCIDENTAL, OR CONSEQUENTIAL DAMAGES IRRESPECTIVE OF WHETHER TEKTRONIX OR THE VENDOR HAS ADVANCE NOTICE OF THE POSSIBILITY OF SUCH DAMAGES. [W2 15AUG04]

Table of Contents General safety summary... ii Compliance Information... iv Safety Compliance... iv Environmental Considerations... vi TCP305A & TCP312A AC/DC Current Probes... 1 Connect and Degauss... 1 Slider and Conductor Jaw... 2 Ground Lead... 3 Related Documentation... 4 Specifications... 4 Standard Accessories... 4 Recommended Accessories... 4 TCP305A & TCP312A AC/DC Current Probes i

General safety summary General safety summary Review the following safety precautions to avoid injury and prevent damage to this product or any products connected to it. To avoid potential hazards, use this product only as specified. Only qualified personnel should perform service procedures. While using this product, you may need to access other parts of a larger system. Read the safety sections of the other component manuals for warnings and cautions related to operating the system. To avoid fire or personal injury Connect and disconnect properly. Do not connect or disconnect probes or test leads while they are connected to a voltage source. Connect and disconnect properly. De-energize the circuit under test before connecting or disconnecting the current probe. Connect and disconnect properly. Connect the probe output to the measurement instrument before connecting the probe to the circuit under test. Connect the probe reference lead to the circuit under test before connecting the probe input. Disconnect the probe input and the probe reference lead from the circuit under test before disconnecting the probe from the measurement instrument. Observe all terminal ratings. To avoid fire or shock hazard, observe all ratings and markings on the product. Consult the product manual for further ratings information before making connections to the product. Do not connect a current probe to any wire that carries voltages above the current probe voltage rating. Do not operate without covers. Do not operate this product with covers or panels removed. Do not operate with suspected failures. If you suspect that there is damage to this product, have it inspected by qualified service personnel. Avoid exposed circuitry. Do not touch exposed connections and components when power is present. ii TCP305A & TCP312A AC/DC Current Probes

General safety summary Do not operate in wet/damp conditions. Do not operate in an explosive atmosphere. Keep product surfaces clean and dry. Terms in this manual These terms may appear in this manual: WARNING. Warning statements identify conditions or practices that could result in injury or loss of life. CAUTION. Caution statements identify conditions or practices that could result in damage to this product or other property. Symbols and terms on the product These terms may appear on the product: DANGER indicates an injury hazard immediately accessible as you read the marking. WARNING indicates an injury hazard not immediately accessible as you read the marking. CAUTION indicates a hazard to property including the product. The following symbol(s) may appear on the product: TCP305A & TCP312A AC/DC Current Probes iii

Compliance Information Compliance Information This section lists the safety and environmental standards with which the instrument complies. Safety Compliance EC Declaration of Conformity Low Voltage Compliance was demonstrated to the following specification as listed in the Official Journal of the European Communities: Low Voltage Directive 2006/95/EC. EN 61010-1: 2001. Safety requirements for electrical equipment for measurement control and laboratory use. EN 61010-2-032: 2002. Particular requirements for handheld current clamps for electrical measurement and test equipment. U.S. Nationally Recognized Testing Laboratory Listing UL 61010-1:2004, 2 nd Edition. Standard for electrical measuring and test equipment. IEC 61010-2-032:2002. Particular requirements for handheld current clamps for electrical measurement and test equipment. Canadian Certification CAN/CSA-C22.2 No. 61010-1:2004. Safety requirements for electrical equipment for measurement, control, and laboratory use. Part 1. CAN/CSA-C22.2 No. 61010-2-032-04, 2 nd Edition. Particular requirements for handheld and hand-manipulated current sensors for electrical measurement and test equipment. Additional Compliances IEC 61010-1: 2001. Safety requirements for electrical equipment for measurement, control, and laboratory use. IEC 61010-2-032: 2002. Particular requirements for handheld current clamps for electrical measurement and test equipment. Equipment Type Test and measuring equipment. iv TCP305A & TCP312A AC/DC Current Probes

Compliance Information Pollution Degree Description A measure of the contaminants that could occur in the environment around and within a product. Typically the internal environment inside a product is considered to be the same as the external. Products should be used only in the environment for which they are rated. Pollution Degree 1. No pollution or only dry, nonconductive pollution occurs. Products in this category are generally encapsulated, hermetically sealed, or located in clean rooms. Pollution Degree 2. Normally only dry, nonconductive pollution occurs. Occasionally a temporary conductivity that is caused by condensation must be expected. This location is a typical office/home environment. Temporary condensation occurs only when the product is out of service. Pollution Degree 3. Conductive pollution, or dry, nonconductive pollution that becomes conductive due to condensation. These are sheltered locations where neither temperature nor humidity is controlled. The area is protected from direct sunshine, rain, or direct wind. Pollution Degree 4. Pollution that generates persistent conductivity through conductive dust, rain, or snow. Typical outdoor locations. Pollution Degree Pollution Degree 2 (as defined in IEC 61010-1). Note: Rated for indoor use only. Installation (Overvoltage) Category Descriptions Terminals on this product may have different installation (overvoltage) category designations. The installation categories are: Measurement Category IV. For measurements performed at the source of low-voltage installation. Measurement Category III. For measurements performed in the building installation. Measurement Category II. For measurements performed on circuits directly connected to the low-voltage installation. Measurement Category I. For measurements performed on circuits not directly connected to MAINS. Measurement category: CAT II TCP305A & TCP312A AC/DC Current Probes v

Compliance Information Environmental Considerations This section provides information about the environmental impact of the product. Product End-of-Life Handling Observe the following guidelines when recycling an instrument or component: Equipment recycling. Production of this equipment required the extraction and use of natural resources. The equipment may contain substances that could be harmful to the environment or human health if improperly handled at the product s end of life. To avoid release of such substances into the environment and to reduce the use of natural resources, we encourage you to recycle this product in an appropriate system that will ensure that most of the materials are reused or recycled appropriately. This symbol indicates that this product complies with the applicable European Union requirements according to Directives 2002/96/EC and 2006/66/EC on waste electrical and electronic equipment (WEEE) and batteries. For information about recycling options, check the Support/Service section of the Tektronix Web site (www.tektronix.com). Restriction of Hazardous Substances This product is classified as an industrial monitoring and control instrument accessory, and is not required to comply with the substance restrictions of the recast RoHS Directive 2011/65/EU until July 22, 2017. vi TCP305A & TCP312A AC/DC Current Probes

TCP305A & TCP312A AC/DC Current Probes TCP305A and TCP312A Current Probes are designed to work with the TCPA300 Current Probe Amplifier. These instructions briefly describe the probes. For more information, refer to the TCPA300/400 Amplifiers & TCP300/400 Series AC/DC Current Probes User Manual that ships with the amplifier. WARNING. To reduce risk of shock or fire, refer to the TCPA300/400 Amplifiers & TCP300/400 Series AC/DC Current Probes User Manual before using the probe. Connect and Degauss To connect the current probe to the amplifier, align the red dots on the two connectors and gently push the probe connector in. Do not twist the connector. To disconnect the probe, first pull back the collar and then pull out the connector. Degauss the probe before you take measurements: Close the probe slider, press the PROBE DEGAUSS AUTOBALANCE button on the amplifier, and then wait 5 seconds for the LED to turn green. See your amplifier manual for complete details. TCP305A & TCP312A AC/DC Current Probes 1

TCP305A & TCP312A AC/DC Current Probes Slider and Conductor Jaw 1. When the slider is in the closed (locked) position, you can degauss the probe. 2. Move the slider to the unlocked position to insert and remove conductors to and from the jaw. 3. The jaw can accept a 5 mm (0.2 in) diameter maximum conductor size. WARNING. To prevent probe damage, do not force conductors larger than 5 mm (0.2 in) diameter into the jaw. 4. Close the jaw around the conductor and lock the slider. When you are taking measurements, keep your fingers behind the demarcations on the probe, and away from the shaded area. WARNING. Do not connect the current probe to any wire that carries voltages or currents that exceed the rating of the probes. 2 TCP305A & TCP312A AC/DC Current Probes

TCP305A & TCP312A AC/DC Current Probes Ground Lead The 6-inch ground lead grounds the shield around the probe transformer at the probe end of the cable. This allows you to move the ground connection closer to the circuit you are measuring, thereby improving high frequency response. The ground lead clips onto the ground connector on the bottom of the probe. The ground lead on the current probes is intended to be used in high dv/dt environments. The probes have a grounded shield between the conductor under test and the current sense transformer. Any capacitively-coupled current will then flow in the ground instead of the transformer windings. When you take high frequency measurements, connect the probe ground lead to the probe ground connector and attach the alligator clip directly to RF ground to improve EMI rejection at high frequencies (2 MHz and above). This will reduce ringing and help bypass capacitively-coupled RF currents which can flow into the probe cable. In some cases, it may be helpful to move the ground lead or reposition the probe away from noise sources in the circuit under test. TCP305A & TCP312A AC/DC Current Probes 3

TCP305A & TCP312A AC/DC Current Probes Related Documentation The TCPA300/400 Amplifiers & TCP300/400 Series AC/DC Current Probes User Manual, Tektronix part number 077-1183-xx, contains a complete list of specifications, accessories, and operating information for the probes. It is a pdf file that is included on the documentation CD that ships with the amplifiers. The manual can also be downloaded from the Tektronix Web site. To download manuals and other product information, go to www.tektronix.com/manuals. Specifications TCP305A: DC 50 MHz, 50 A DC TCP312A: DC 100 MHz, 30 A DC Standard Accessories The following accessories are shipped with the probes: Accessory Tektronix part number Probe ground lead, 6 inch length 119-3521-xx Instruction sheet 071-3032-xx Certificate of traceable calibration Recommended Accessories The following accessories can be ordered for your probes: Accessory Deskew fixture High frequency current loop Travel case Tektronix part number 067-1478-xx 067-2396-xx 016-1922-xx 4 TCP305A & TCP312A AC/DC Current Probes