Ademco Vista-20SE/First Alert FA-162C Program Sheet

Property of Monitronics Inc

Property of Monitronics Inc

First Alert FA160C/162C Installer Notes M. Leuck

Installer Notes 4110DL/XM, Vista 10, Vista-20, Via-30PSE

VISTA-20BAY PROGRAMMING GUIDE SECURITY SYSTEM SINCE 1946

Ademco/Protection One 250P1-1 Programming Form

VISTA-20SEa. 3-Partition Security System. Programming Form. V20SEaPRV1 9/98

3 6HFXULW\6\VWHP 3URJUDPPLQJ)RUP K4332 9/99 BYPASS NOT READY ARMED READY 4 MAX 5 TEST 6 BYPASS 7INSTANT 8 CODE 9CHIME READY ARMED

DAYLIGHT SAVINGS TIME START/END MONTH [ 0 ]0 = Disabled; 1 = Enabled. 1 Start End

CUSTOMER INFORMATION

Programming Default Tables

Property of Monitronics Inc

4140XMPT2 PROGRAMMING FORM

FA168CPS / FA168CPSSIA FA148CP / FA148CPSIA

*00 INSTALLER CODE Enter 4 digits, 0-9 [4140] *28 POWER UP IN PREVIOUS STATE [1=yes] 0=no; "1" for UL.

LYNX Security System 3URJUDPPLQJ)RUP 6XPPDU\RI&RQQHFWLRQV. Features Q.E.D. programming for quick enrollment of devices.

VISTA-128BP/VISTA-250BP Programming Form

VISTA-50P VISTA-50PUL

ADEMCO LYNXR-ENSIA Security System

ADEMCO VISTA-48A Security Systems

5HDG\*XDUG56HULHV 6H XULW\6\VWHPV 3URJUDPPLQJ*XLGHIRU5HDG\*XDUG5DQG 5HDG\*XDUG5(1 K /01 OFF AWAY STAY AUX

&RPPHUFLDO)LUHDQG%XUJODU\ 3DUWLWLRQHG6HFXULW\6\VWHP ZLWK6FKHGXOLQJ

Created by: Alarm System Store Quick Start Guide. for Interlogix NetworX NX4, NX6 & NX8

4XLFN6WDUW*XLGH. LYNXR is not intended for UL985 Household Fire applications.

Commercial Burglary Partitioned Security System With Scheduling. Programming Guide. K5894PRV4 6/04 Rev A

1HWZRU;1;( Table of Contents. General Description...2. Ordering Information...2. Feature Definitions...3. Programming the LED Keypads...

APX32EN Security Systems

Control Panel ICP-SOL2-P/ICP-SOL3-P. en Quick Reference Guide

3DUWLWLRQHG6HFXULW\6\VWHPV ZLWK6FKHGXOLQJ

I-NX8V2-IM Rev F Dec NetworX Series NX-8V2 Control Panel Installation and Setup

Commercial Fire and Burglary Partitioned Security System with Scheduling. Programming Guide. K0376PRV5 2/11 Rev. A

VISTA 12a / 48a TECHNICAL TRAINING. The Best in Security plus Everyday Convenience & Control

2 IDS LCD Keypad User Manual C Issued March 2009

RANGER 9000E DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

High Security and Access System EVO48 V2.1 EVO192 V2.1

Series. NX-8-EUR Control Panel. Installation manual

Lynx Plus Security System

MCM Electronics MCM Electronics MCM Electronics. The Icon Series. Installation and Programming Information. Icon 8 Version 5.0

Important Notice. Customer Information. 2 WisDom User Manual

ADEMCO VISTA SERIES VISTA-20P / VISTA-20PSIA VISTA-15P / VISTA-15PSIA Security Systems

NetworX Series NX-8V2 Control Panel Installation and Startup

Safecom Solution-16 Quick Reference Guide ISSUE 1.10

IDS1200 INSTALLER MANUAL. Summary of Operation 2 IDS1200 INSTALLER MANUAL - NO B ISSUED AUGUST 2002 VER 1.18

IDS. Users Guide to Keypad Functions S E C U R I T Y MANUAL NO D ISSUED NOVEMBER 2002 VERSION 2.

DAS 250L CONTROL COMMUNICATOR INSTALLATION MANUAL

Contents. 4. Disarming the Control Panel How to Disarm with a User Code How to Disarm using a Key-Switch or Remote...

Quick Start: 2. Connect AC power first and then the battery. 3. Configure the keypad (see page 44).

Installation Instructions

Programming Worksheets

VISTA-40. Programming Guide. 2-Partition Security System. Single Partition and 2-Partition Programming Forms N7001PRV4 7/98

NX-148 LCD KEYPAD INSTALLATION MANUAL

PROGRAMMING HELP GUIDE

D1260/D1260B. Owner's Manual. Keypad

Telephone and Reporting Setup in ElkRP

Modules Programming Guide. paradox.com

IDS X-Series User Manual E Issued June 2013

DSC programming for the Alexor and Impassa

EVOHD. Programming Guide. Version

FOCUS 200 PLUS A CCC #: _ / / _ / ( _ ) _ - 35(/,0,1$5< -8/< Security Services CUSTOMER CONTROL UNIT TELEPHONE NUMBER:

Digiplex EVO High Security and Access System What s New EVO192 V2.7

Solution 16 plus. User Guide Security System

Control Panel Solution 2000 / 3000

AMAX panel. AMAX panel 2100 AMAX panel 3000 AMAX panel 3000 BE AMAX panel en Operation Manual

2 4PI175 issue 1_6/01. How to unset system in alarm. Programs 1, 2 and 3. Access codes. How to operate Personal Attack

GEM-P9600 CONTROL PANEL/COMMUNICATOR

Bosch solution 6000 cheat sheets

Control Panels D9412GV4/D7412GV4. en Owner's Manual

Control Panels B9512G/B8512G/B6512/B5512/B4512/B3512. en Owner's Manual

SILENCING AN ALARM. When the alarm bell or siren is sounding, enter your user code or present your keyfob to your keypad.

INPUTS: Are 10K end of line monitored, with a response time of 300 ms. Alarm triggers SIREN, STROBE and REPORTING (depending on setup)

VISTA-50PADT VISTA-50PADTUL

Developer s Guide. PC54O1 Serial Interface Module Version 1.0

THE OPERATOR INTRODUCTION 2 ACCESSING YOUR SYSTEM 2 FUNCTIONS OF THE "OPERATOR" 3 PROGRAMMING/CHANGING ACCESS CODES 12 ACTIVATING EMERGENCY ALARMS 13

INSTALLATION MANUAL. Table of Contents. General Description Position Dip Switch Settings Enrolling the NX216-E Expander...

MG/SP Series (V4.9/V5.1) What s New

i Note Intrusion Control Panel Solution 64 Release Notes for Version Release Notes March, 2007

VoiceNav User Manual

Table of Contents. Phone number configuration...15 Alarm Phone numbers, 1, 2 & Divert phone numbers 1, 2 &

XT30/XT50 PROGRAMMING PART 1. Slide 1. Slide 2. Slide 3. Objectives. XT30/XT50 Basic Training Programming- Part 1. Accessing the Programmer

Emergency Dialer DIAL-ALERT MODEL: AD-105.

SECURITY MODULE CG3 User Manual

Silencing an Alarm Note: Area Systems

SUPERPLEX. User s Manual. High performance, simplified wireless home security controller. Products that work. Software Release: V2.

Security System. Owner s Manual

Installation Quick Start Guide

LCD User Station User Manual

Modules Programming Guide

DAS ALPHA NUMERIC LCD CODEPAD INSTALLATION MANUAL

REMOTE KEYPAD with NFC Tag (KPT-32N, KPT-32N-F1)

(To modify t he installer code, ref er to section [ 1000], Installer Code Programming on page 21) 1234 or

Solution 144 Security Systems

SOFTWARE VERSION 3.10

R A D I O N I C S. D7212B Control/Communicator Program Entry Guide C 9/95

FSK TX CELLULAR PLUS. Installation and Programming Guide. Tel:

DAS LCD ALPHA NUMERIC CODEPAD

Silencing an Alarm Note: Area Systems

XR150/XR350/XR550 USER S GUIDE

NX-1248E LCD KEYPAD Installation and Setup

Agility Installation Quick Start Guide 1

Transcription:

Enter Program Master Code + 8 + 0 + 0 (Display should show 20) or Power down then back up and press * and # within 1 minute (If exiting programming you can re-enter within 1 minute by pressing * and #) Move to Location View Location * + Location # + Location (Display will read off one digit at a time) Exit Program 1. *98 OR 2. *99 if needing to re-enter programming later by Code + 8 + 00 *20 Master Code I _ 4 _I _ 1 _I _ 1 _I _ 1 _I *21 Quick Arm Enable I _ 1 _I 0 = No *22 RF System Type I _? _I 0 = None 5700 Sensors are added as hardwire zones 10 to 18 1 = 5700 (4281) Receiver 4281L receiver adds 4 zones, 4281M and 4281H add 8 zones 2 = 5800 (5881) Receiver *23 Force Bypass Enable I _ 0 _I 0 = No *24 RF House Code I _ 0 _I _ 0 _I 00 = Disabled / 01-31 Used only with 5700 series wireless 5804BD keyfob and 5827BD Keypad *25 Output Relay Module I _ 0 _I 0 = None 1 = 4219 Relay/Zone Expander 2 = 4229 Relay/Zone Expander 3 = 4204 Relay Module *26 4284/4285 Voice Module Code I _ 0 _I _ 0 _I 00 = Disabled (Allows access to Voice module) 1st digit = 1 to 9 2nd digit = # + 11 = * or # + 12 = # *27 Output to Long Range Radio I _ 0 _I 0 = No *28 Single Alarm Sound/Zone I _ 0 _I 0 = No *29 Fire Sounder Timeout I _ 1 _I 0 = Yes 1 = No Fire Timeout *30 Alarm Bell Timeout I _ 2 _I 0 = None 1 = 4 minutes 3 = 12 minutes 2 = 8 minutes 4 = 16 minutes *38 Entry Delay I _ 2 _I 1 = 20 seconds 4 = 60 seconds Exit Delay = Entry + 15 seconds 2 = 30 seconds 5 = 90 seconds 3 = 45 seconds *39 Audible Exit Warning I _ 1 _I 0 = No *40 PABX Access Code I I I I I (If 9 is needed to dial add here) *41 Primary Phone (12 digits) I I I I I I I I I I I I I End Phone with * # + 11 = * # + 12 = # # + 13 = 2.5 second pause *42 Secondary Phone I I I I I I I I I I I I I (This system does not support pagers) *43 Subscriber Account I I I I I Hex A = # + 10 B = # + 11 C = # + 12 D = # + 13 E = # + 14 F = # + 15 *45 Phone Sys Select I _ 1 _I 0 = Pulse Dial 1 = DTMF Dial 2 = Pulse Dial, CS on Watts Line 3 = DTMF Dial, CS on Watts Line *46 Report Format I _ 7 _I 0 = 3/1, 4/1 Ademco L/S Standard 1 = 3/1, 4/1 Radionics Standard 2 = 4/2 Ademco L/S Standard 3 = 4/2 Radionics Standard 6 = 4/2 Ademco Express 7 = Contact ID 8 = 3/1, 4/1 Ademco L/S Expanded 9 = 3/1, 4/1 Radionics Expanded

*47 Split/Dual Reporting I _ 0 _I (use 6 for pagers) To Primary Phone To Secondary Phone 0 = All Reports Backup only 1 = Alarms, Restore, Cancel All Other Reports 2 = All Reports except Open/Close, Test Open/Close, Test 3 = Alarms, Restore, Cancel All Reports 4 = All Reports except Open/Close, Test All Reports 5 = All Reports (Dual Reporting) All Reports *48 15 Sec Burg Dial Delay I _ 0 _I 0 = No *49 Periodic Test Message I _ 3 _I 0 = None 1 = 24 Hours 2 = Weekly 3 = Monthly *50 Sescoa/Radionics I _ 0 _I 0 = No *51 Confirmation of Arming Ding I _ 0 _I 0 = No 2 = Yes for RF Arming (keyfobs etc) *52 Zone 3 Response I _ 0 _I 0 = 400 ms 1 = 10 ms Must use 6139 Alpha Keypad here *56 Zone Assignments 1. Enter Zone to program (01 to 96) (* for next, # for previous menu) Hardwire Zones 05 and 06 4219/4229 Expander Zones 10 to 17 Police Panic Zone 07 Duress Zone 08 Receiver Trouble Zone 09 Wireless Zones 10 to 39 (Depends on receiver capacity) Fire Panic Zone 95 Medical Panic Zone 96 2. This shows current summary of Zone programming (* for next, # for previous menu) 3. Enter Zone Type (* for next, # for previous menu) 00 = Zone Disabled 08 = 24 hour Aux/Medical 01 = Delay Zone 09 = Fire 02 = Do not Use 10 = Interior Delay 03 = Perimeter/Instant 20 = Arm-Stay (RF only) 04 = Interior Follower/Motions 21 = Arm-Away (RF only) 05 = Trouble by Day/Alarm by Night 22 = Disarm (RF only) 06 = 24 hour Silent/Holdup 23 = No Alarm Response 07 = 24 hour Police Panic 4. Enter Report Code (* for next, # for previous menu) (10 in first section gives a report of A0) Hardwire Zones will advance to step 8, for Wireless Zones continue (If it doesn't go to next steps check if Receiver has been programmed in *22) 5. Enter type of Sensor 3 for Supervised RF (most sensors are RF) 4 for Un-Supervised RF 5 RF Button Type (Keyfobs/Panics etc)

6. Enter Loop number (Some older systems) (* for next, # for previous menu) 7. Serial Number Programming Door Switch Internal switch Loop 2, external sensor Loop 1 Glassbreak Loop 1 Smoke Detectors Loop 1 Motions Loop 1 Keyfobs (Each button = 1 zone) Loop 1 Bottom Right Button Loop 2 Top Right Button Loop 3 Top Left Button Loop 4 Bottom Left Button Press 1 and enter serial number or trip sensor twice, 1 st time to learn, 2nd to confirm Note: Serial number found on sticker on of sensor This shows ready to learn This shows Serial Number either manually entered or learned This may appear showing sensor was confirmed by activating twice 8. This is the new programming of sensor (* for next, # for previous menu) 9. Normally press 0 to return to start or 1 if if customer has 6139 keypad *60 Trouble Report Code I _ 1 _I _ 0 _I *61 Bypass Report Code I _ 0 _I _ 0 _I *62 AC Loss Report Code I _ 1 _I _ 0 _I *63 Low Bat Report Code I _ 1 _I _ 0 _I *64 Test Report Code I _ 0 _I _ 0 _I *65 Open (Disarm)/Exit Alarm I _ 0 _I _ 0 _I 1st digit = Opening Report 2nd digit = Exit Alarm *66 Away/Stay Report Code I _ 0 _I Away I _ 0 _I Stay *67 RF Xmtr Low Bat Report Code I _ 0 _I _ 0 _I *68 Cancel Report Code I _ 1 _I _ 0 _I *69 Group Restore Trouble/RF/Bypass I _ 0 _I *70 Alarm Restore Report Code I _ 0 _I *71 Trouble Restore Report Code I _ 0 _I _ 0 _I *72 Bypass Restore Report Code I _ 0 _I _ 0 _I *73 AC Restore Report Code I _ 0 _I _ 0 _I *74 Low Bat Restore Report Code I _ 0 _I _ 0 _I *75 RF Low Bat Restore Report Code I _ 0 _I _ 0 _I *82 Custom Alpha Editing *83 Sequential Mode *91 Option Selection I _ 0 _I 0 = None 4 = AAV 2-way module enable (4 turns off siren sounds during 2-way) *92 Reports per Armed Period I _ 0 _I 0 = 10 per armed period 1 = Unlimited per Armed period

*94 Download Phone Number I _1 _I _ 8 _I _0 _I _ 0 _I _6 _I _ 8 _I _2 _I _ 1 _I _6 _I _ 9 _I _0 _I I *95 Ring Count I _# 15 _I (0 to #15 #15 = Answer Machine) *96 Reinitialize Download (No Value needed, keypad will just beep) *97 Default Panel (No Value needed, keypad will beep and default panel) *98 Exits Program Mode (Will not allow re-entry with Installer Code + 8 + 0 + 0) *99 Exits Program Mode (Will allow re-entry with Code + 8 + 0 + 0) *80 Output Device Programming (If 4204 Relay or 4229 Zone Expander is used) 1. Enter Device to program (01 to 04) (* for next, 00 to exit) 2. This shows summary of current Relay START programming (* for next, # for previous menu) (What starts the Relay) 3. This shows summary of current Relay STOP programming (* for next, # for previous menu) (What stops the Relay) 4. Enter what Relay will do when activated (* for next, # for previous menu) 0 = No Response (or skip) 1 = Close for 2 seconds 2 = Close and stay closed 3 = Continuous Pulse On/Off 5. Enter what will start the Relay (optional) (* for next, # for previous menu) 0 = Not Used (or skip) 1 = on an Alarm 2 = on a Zone Fault (or Keyfob button) 3 = on a Trouble 6. Enter Zone List from *81 which STARTS Relay (optional) (* for next, # for previous menu) 0 = Not Used (or skip) 1 = Zone List 1 2 = Zone List 2 3 = Zone List 3 7. Enter Zone Type that will START the Relay (optional) (* for next, # for previous menu) 00 = Not Used (or skip) 31 = End of Exit Time 01 = Entry/Exit Zone 32 = Start of Entry Time 03 = Perimeter/Instant Zone 33 = Any Burglar Alarm 04 = Interior Follower/Motions 34 = Code + # + 7 Key Entry 05 = Trouble by Day/Alarm by Night 35 = Code + # + 8 Key Entry 06 = 24 hour Silent/Holdup 36 = Bell Timeout or Disarm 07 = 24 hour Police Panic 37 = 2x Bell Timeout or Disarm 08 = 24 hour Aux/Medical 38 = Chime 09 = Fire 39 = Any Fire Alarm 10 = Interior Delay 40 = Bypassing 20 = Arm-Stay 41 = AC Power Failure 21 = Arm-Away 42 = System Low Battery 22 = Disarming

8. Enter Zone List that will STOP the Relay (optional) (* for next, # for previous menu) 0 = Not Used/Skip 1 = Zone List 1 2 = Zone List 2 3 = Zone List 3 9. Enter Zone Type that will STOP the Relay (optional) (* for next, # for previous menu) 10. This shows summary of new Relay START programming (* for next, # for previous menu) 11. This shows summary of new Relay STOP programming (* for next, # for previous menu) 12. Enter next Relay/Device to program or 00 to exit *81 Zone Lists for Output Devices 1. Enter Zone List to program (01 to 03) or 00 to Quit (* for next, # for previous menu) 2. Enter Zone Number to add to List (01, 02 etc) or 00 to Quit (* for next, # for previous menu) Multiple Zones can be added (example: 01* 03* 25*etc) 3. If deleting a Zone List enter (01 to 03) or 0 to skip (* for next, # for previous menu) 4. If deleting Zone within Zone List enter 1 or 0 to skip (* for next, # for previous menu) 4a. If 1 was entered from previous step enter here then 00 (* for next, # for previous menu) Multiple Zones can be deleted (example: 01* 03* 25*etc) 5. Enter next Zone List to program or 00 to Quit (* for next, # for previous menu)

Monitronics Monitoring and Service: 1-800-447-9239 Ademco Via-30/Via-30P Quick Reference Guide Arm Away User Code + AWAY key (2), the ARM light will turn on and the display will show AWAY Note: If system shows NOT READY press to view open zones Arm Stay User Code + STAY key (3), the ARM light will turn on and the display will show STAY Disarming / Silencing Alarms Instant Doors Zone Bypassing User Codes User Code + OFF key (1) If turning off an alarm enter 4 digit code + OFF key (1) again to clear display User Code + INSTANT (7) to arm system Entry/Exit doors will arm instant and motion detectors will be bypassed (display will show both STAY and INSTANT) User Code + BYPASS key (6) + zone (05 to 35) Note: Fire/Smoke Detector Zones cannot be bypassed Enter MASTER CODE + CODE key (8) Enter User to program (2 to 7) Enter new 4-digit User Code (Keypad will beep if command is successful) To delete a code Enter MASTER CODE + CODE key (8) Enter User to delete (3 to 7) then wait 3 seconds (Keypad will beep if command is successful) Master Code can only be changed by a Service Tech or by remote downloading Door Chimes Master Code + CHIME (9), if activated the display will show CHIME, repeat to turn Chimes OFF Trouble Display Panic Buttons NO AC = Loss of AC power to the system LOW BAT = Main panel has a low battery, if LOW BAT appears with a zone number that zone has low battery CHECK = There is a problem with a wireless zone, fire zone or the main systems wireless receiver By holding down a combination of numbers will activate the Police, Fire and Medical Panics Press and # at same time for Police Panic Press 1 and at the same time for Fire Panic Press 3 and # at the same time for Medical Panic Note: The Fire and Medical Panics may be reversed or disabled on some systems Do not pause more than 2 seconds between each keypress or system will ignore above commands