Sicherheit, auf die Sie sich verlassen können

Similar documents
Sicherheit, auf die Sie sich verlassen können

Industrial Plugs & Receptacles

Sicherheit, auf die Sie sich verlassen können

Providing flexible power supply and signal connection there, where it is needed even in hazardous areas for the Zones 1and 2.

Terminal Boxes Series 8118

Ex-control switch Typ 292 without and Typ 293 with measuring instrument

2.3. Ex-Linear light fittings for fluorescent lamps. ellk W 58 W / ellm W 36 W (Zone 1, 2, 21, 22)

Emergency Luminaire for Fluorescent Lamps Series EXLUX 6009

Linear Luminaire with LED Series EXLUX 6002/1 Version IIB+H2

Load Disconnect Switches and Motor Switches

Throughwiring. single-ended. twin-ended

2.2. Ex-Linear LED light fittings. ellk/m 92 LED 400/800 / ellk/m 92 LED 400/800 V-CG-S / NE / NIB-HT / NIB-CSA (Zone 1, 2, 21, 22)

Sales: Malux Finland Oy, P.O.Box 69, FI Porvoo, Phone , Fax ,

exlink Mining Electrical connectors for mining

INSTALLATION TECHNOLOGY MADE EASY

Industrial Light Fittings. for harsh and arduous environment

Control Stations & Switches: Switches, Circuit Breakers and "Break Glass" Call Points SWE Series: 16 and 20 A Switches Increased Safety

Product manual plug, sockets and coupler 16 A.- Z0251

Linear Luminaire with LED Series 6012/5

ATX MRE Series 16 and 32 Amp Multiple Socket Outlets Stationary and Portable. Increased Safety

Ex Junction Boxes & Control Stations

SolConeX Wall-Mounted Socket, 16 A

3.2. Ex-d/e Cable Glands Metal Design. For Zone 1, 2, 21 and 22 according EN :2012 / IEC : 2011

MRE Series 16 and 32 Amp Multiple Socket Outlets Stationary and Portable. Increased Safety

Grounding Monitoring Device Series 8485

SolConeX extra-low voltage flange socket

Junction Boxes & Enclosures JBEP and ECEP Series: Undrilled Fiberglass Reinforced Polyester Enclosures Increased Safety

Linear Luminaire with LED Series 6412/5

Cable End Boxes Series 8146

Grounding Monitoring Device Series 8485

5 Fieldbus Technology

Technical Datasheet. Connectors, Plugs & Sockets. Table of Contents. Selection Guide 2. 16A Range (ELCX ) 3. 32A Range (ELCX

Minimum cross sectional area of Conductor mm²

Switch rated plugs and receptacles with NEMA 4X protection

Conveyor Belt Alignment Switches from IDEM

Position Switches Series 8070

Grounding Systems / Ground Monitoring Device Series 8146/5075 and 8125/5071

M C. Ex d M-0... control, monitoring and signalling devices

TABLE OF CONTENTS. IEC and IEC Pin and Sleeve Devices. IEC and IEC Mechanical Interlocks. Manual Disconnect Switches

Inductive dual sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933

Tubular Light Fitting with LED Series 6036

Termination Board FC-GPCS-SAI16-PF. Features. Assembly. Function. Connection. SAI-1620m HART 24 V DC (I), 24 V DC (II) Fault. Zone 0, 1, 2 Div.

LED lighting for heavy industrial areas Champ Pro PLL LED Luminaires. Champ Pro PLL. LED luminaires for heavy industrial areas

Inductive sensor Dual sensors with extended temperature range NI4-DSU35TC-2Y1X2/S97

Pin & Sleeve. EUREKA-HD Series WATERPROOF SPLASHPROOF. Heavy duty Industrial Wiring Devices

Ex emergency pull-wire switches Ex ZS 71

DECONTACTOR METAL 20 A/32 A/63 A/125 A/200 A

Resistance thermometer With spring-loaded tip Model TR55

Wastewater Solutions. Featuring Meltric s DECONTACTOR TM Series Switch-Rated Plugs, Receptacles and Electrical Connectors. meltric.

Ex-CELL Stainless Steel and Painted Steel Enclosures

Control Units Ex e in Stainless Steel LCS*.*

I Ex-Installation switch I

30 A / 50 A / 90 A / 150 A / 250 A

GRP Flameproof Visual Signal Xenon or Steady LED

Electrical Apparatus. for harsh environments

Inductive sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933

Inductive sensor with analog output BI15-M30-LI-EXI

D-Sub SEaled subminiature D connectors, 2.54 mm pitch

ECE Cert.fic te of Con ormity

Safety switches with separate actuator

Junction Boxes & Enclosures JBEA and ECEA Series: Aluminum Enclosures Increased Safety

Cable Glands 757, BVE and 737 Series: Blanking Plugs, Adaptors and Reducers Increased Safety and Flameproof

SIZE 1, 2 AND 3 POLYAMIDE PRE-DRILLED CONTROL STATIONS

IECEx Certificate of Conformity

DECONTACTOR METAL 20 A/30 A/50 A/90 A

Inductive sensor For rotary actuators NI4-DSU35TC-2Y1X2

Inductive sensor NI3-EG08K-Y1-H1341

Inductive sensor BI1.5-EG08-Y1-H1341

Threaded resistance thermometer Miniature design Model TR10-D

Digital Output Module 4-Channel Version for Zone 1 Series 9475/

Cable distribution systems

Han R 23. Circular Connector. Certified acc. to DIN EN ISO 9001 in design/ development, production, installation and servicing.

Threaded thermocouple Miniature design Model TC10-D

Compact plugs and receptacles standard or high temperature rated

Safety switches for hinged doors

TO ALL OUR CUSTOMERS 1. NEW ADVANCE GRP SERIES - 16A-32A-63A INTERLOCKED SOCKETS IN THERMOSET TING MATERIAL

Operating instructions (Safety-related part ATEX and IECEx) Inductive NAMUR sensors NN504A NN505A NN506A NN507A /00 08/2015

Inductive sensor BI1.5-EG08-Y1-H1341

DECONTACTOR FOR INDUSTRY 30 A / 50 A / 90 A / 150 A / 250 A

Operating Manual / IEC. Explosion-Proofed Junction Boxes, Polyester. Wallücker Bahndamm 7 DE Kirchlengern

IECEx Certificate of Conformity

Pneumatic Control/Feedback

Installation Equipments

IEC H.P. Rated Pin and Sleeve Sequential contacts engagement during mating and un-mating IEC configurations specific to each voltage and

SKX 12 SKX 15. Zone. make your work surroundings safer IP 66

K1F003MCH cam ammeter switch - 3 circuits A - for Ø 22 mm

DISCONNECTABLE MOTOR SWITCH AC-3 UP TO 45 kw

Bayonet resistance thermometer Model TR53

Inductive sensor For rotary actuators NI4-DSU35-2Y1X2-H1140

Safety switches with manual mechanical delay and separate actuator

K1D004ACH cam switch - 4-pole A - for Ø 22 mm

Sensor boxes SRBC. Festo core product range Covers 80% of your automation tasks

DS185 1G FS Box Switch Cover. Features. Description. Manufacturer Information EATON CROUSE-HINDS SERIES GTIN

Flow Measurement SITRANS F US Inline

P Series PlexPower Distribution Panelboards Increased Safety

K1K015NZ4 cam stepping switch - 2-pole A - screw mounting

Cable Glands. Description Introduction to Cable Glands 399. EEXe Series EEXe Series. A2F, E1FX/E2FX, E1FW/E2FW and T3 Series

ATX JBEA and ECEA Series Aluminum Enclosures Increased Safety

Leviton Products Referenced in the Rockwell Automation ENCOMPASS Program

Pneumatic Control/Feedback

Transcription:

Explosion protected plugs & receptacles Sicherheit, auf die Sie sich verlassen können Extended Temperature Range Ex-plugs & receptacles 16 A and 63 A for Zone 1 and 21 www.crouse-hinds.de EATON 2.1.1

in with GHG51 IEC 60309 plugs and interlocks for hazardous environments Eaton's Crouse-Hinds GHG 51 series IEC 60309 plugs are IP66 rated and engineered to provide secure, safe and waterproof connections in the toughest conditions. Even tougher. Now with an expanded temperature range of -55 C to +55 C for use in extreme conditions. Expanded temperature range Easy to install Impact resistant enclosure Low engagement force IP66 compliant when plugged in Self-cleaning lamellar contacts Low transition resistance between plug and receptacle 2.1.2 EATON www.crouse-hinds.de

Overview s Applications: For extreme low temperatures (Yamal) For extreme high temperatures (Middle East) Where complete protection against dirt, dust and water jets is required In areas prone to vibration, hard use, and abuse In environments that demand safety, ease of use, reliability, and durability Ideal for hazardous areas or heavy duty industrial applications, such as: chemical/petrochemical, refineries, shipyards, military, marine/marina environments, pulp and paper, heavy manufacturing, wastewater treatment, portable power Features: Voltage, configured, colour coded Watertight Impact- and corrosion-resistant Innovative finger lock keeps cord grip secured Positive grommet seal system at cord entry Lockout/tagout High grade nickel-plated brass pins Multi-lam sleeve bands, nickel plated beryllium copper Certifications and compliances: IEC60309-1 and IEC60309-2 IEC/EN 60079 IP66 IEC 60529 II 2G/Ex db eb IIC/IIB Gb II 2D Ex tb IIIC/IIIB Db Standard materials: Enclosure - polyamide External hardware - stainless steel Contacts - brass, nickel-plated beryllium copper Contact carrier - glass fibre reinforced nylon PA66 s Applications: To supply power to portable or fixed electrical equipment, such as welders, motor generator sets, compressors, conveyors, portable tools, lighting systems, and similar equipment In hazardous rated areas, damp or corrosive atmospheres, wet locations or hose down areas Features: Mechanically interlocked dead-front receptacle prevents plug from disengaging under load Enclosure has continuous form-in-place gasket Meets OSHA's lockout/tagout requirements - can be padlocked in "OFF" position Internal switch with full AC 3 switching ability (motor-load) Certifications and compliances: IEC60309-1 and IEC60309-2 IEC/EN 60079 IP66 IEC 60529 II 2G/Ex db eb IIC/IIB Gb II 2D Ex tb IIIC/IIIB Db Standard materials: Enclosure - glass fibre reinforced polyester (GRP) External hardware - stainless steel Contacts - brass, nickel plated beryllium copper Contact Carrier - glass fibre reinforced nylon PA66 www.crouse-hinds.de EATON 2.1.3

Ex-plugs & receptacles 16A 3/4/5-pole up to 690 V Technical data Ex-plugs & receptacles accd. to IEC 60309-1/2 16A (wall socket and plug) Marking accd. to2014/34/eu D II 2 G / Ex db eb IIC / IIB T6 /T5 Gb D II 2 D Ex tb IIIC / IIIB db Ec-Type Examination Certificate pending IECEx Certificate of Conformity pending Marking accd. to IECEx Ex db eb IIC / IIB T6 /T5 Gb Permissible ambient temperature -55 C up to +55 C Rated voltage up to 400 V, (3-pole) / 690 V, (4-pole) / 500 V, (5-pole) AC Rated current 16 A Frequency up to 400 Hz Rated making/rated breaking capacity AC3 accd. EN 60947-3 External fuse, max. Protection class accd. to EN 60598 Degree of protection accd. to EN 60529 U e 250 V / I e 16 A (3-pole) U e 690 V / I e 16 A (4-pole) U e 500 V / I e 16 A (5-pole) without thermal protection 16 A with thermal protection 35 A gg (rated current 16 A set to) I IP66 Cable gland 1 x M25 cable gland, 1 x M25 Ex-screw plug plastic or 2 x metal thread M20 with Ex-screw plug plastic Terminals 2 x 1-4 mm 2 Enclosure material Glass fibre reinforced polyester Cable gland Ø 8-19 mm (3-pole) / Ø 8-21 mm (4-pole) / 12-21 mm (5-pole) Terminals 1 x 1.0-2.5 mm 2 Enclosure material Polyamide Ordering details Voltage h Type Aux. contact Cable entry Weight ca. Low temp. High temp. Order No. -55 C up to +40 C -25 C up to +55 C Type 16 A 3-pole 110-130 V Type 16 A 3-pole 200-250 V 4 h 6 h M25 KU 1.2 kg X GHG 511 4304 R0001 M20 GE 1.2 kg X GHG 511 4304 R0002 M20 GE 1.2 kg X GHG 511 4304 R0102 M20 ME 1.3 kg X GHG 511 4304 R3001 M20 ME 1.3 kg X GHG 511 4304 R3101 M20 GM 1.3 kg X GHG 511 4304 R3003 M20 GM 1.3 kg X GHG 511 4304 R3103 0.35 kg X X GHG 511 7304 R0001 M25 KU 1.2 kg X GHG 511 4306 R0001 M20 GE 1.2 kg X GHG 511 4306 R0002 M20 GE 1.2 kg X GHG 511 4306 R0102 M20 ME 1.3 kg X GHG 511 4306 R3001 M20 ME 1.3 kg X GHG 511 4306 R3101 M20 GM 1.3 kg X GHG 511 4306 R3003 M20 GM 1.3 kg X GHG 511 4306 R3103 0.35 kg X X GHG 511 7306 R0001 2.1.4 EATON www.crouse-hinds.de

Ex-plugs & receptacles 16A 3/4/5-pole up to 690 V plug Ordering details Voltage h Type Aux. contact Cable entry Weight ca. Low temp. -55 C up to +40 C Type 16 A 4-pole 200-250 V 380-415 V 480-500 V 600-690 V Type 16 A 5-pole 200-250 V 380-415 V 9 h 6 h 7 h 5 h 6 h Other voltage ranges and versions available on request, KU = 1 x plastic-cable gland M25, 1 x M25 Ex-screw plug plastic ME = 2 x metal thread M20 GE = 2 x plastic thread M20 without cable gland/screw plug GM = 2 x metal thread M20 with screw plug, with external earth bolt M6 High temp. -25 C up to +55 C Order No. KU 1.2 kg X GHG 511 4409 R0001 ME 1.3 kg X GHG 511 4409 R3001 ME 1.3 kg X GHG 511 4409 R3101 GM 1.3 kg X GHG 511 4409 R3003 GM 1.3 kg X GHG 511 4409 R3103 0.35 kg X X GHG 511 7409 R0001 KU 1.2 kg X GHG 511 4406 R0001 ME 1.3 kg X GHG 511 4406 R3001 ME 1.3 kg X GHG 511 4406 R3101 GM 1.3 kg X GHG 511 4406 R3003 GM 1.3 kg X GHG 511 4406 R3103 plug 0.35 kg X X GHG 511 7406 R0001 KU 1.2 kg X GHG 511 4407 R0001 ME 1.3 kg X GHG 511 4407 R3001 ME 1.3 kg X GHG 511 4407 R3103 0.35 kg X X GHG 511 7407 R0001 KU 1.4 kg X GHG 511 4405 R0001 ME 1.5 kg X GHG 511 4405 R3001 ME 1.5 kg X GHG 511 4405 R3101 0.35 kg X X GHG 511 7405 R0001 KU 1.2 kg X GHG 511 4506 R0001 ME 1.3 kg X GHG 511 4506 R3001 ME 1.3 kg X GHG 511 4506 R3101 GM 1.3 kg X GHG 511 4506 R3003 GM 1.3 kg X GHG 511 4506 R3103 0.35 kg X X GHG 511 7506 R0001 www.crouse-hinds.de EATON 2.1.5

Ex-plugs & receptacles 16A 3/4/5-pole up to 690 V Dimension drawing I Wiring diagram 90 X80 11 121 110 X100 11 147 7 7 Dimensions in mm 223 236 155 X115 175 X135 X = fixing dimensions 3-pole 4/5-pole 72 ~172 4 pole 76.5 5 pole 84 ~192 3-pole 4/5-pole without Aux. contact L1 N PE with L1 13 N PE without L1 L2 L3 PE with L1 L2 L3 13 N PE without L1 L2 L3 N PE with L1 L2 L3 13 N PE 1 P + N + PE 14 1P + AUX + N + PE 3P + PE 14 3P + AUX + PE 3P + N + PE 14 3P + N + AUX + PE 2.1.6 EATON www.crouse-hinds.de

Ex-plugs & receptacles 63 A 4- and 5-pole up to 690 V Technical data Ex-plugs & receptacles accd. to IEC 60309-1/2 63 A (wall socket and plug) Marking accd. to2014/34/eu D II 2 G / Ex db eb IIC / IIB T6 /T5 Gb D II 2 D Ex tb IIIC / IIIB db Ec-Typee Examination Certificate Pending IECEx Certificate of Conformity Pending Marking accd. to IECEx Ex db eb IIC / IIB T6 /T5 Gb Permissible ambient temperature -55 C up to+55 C Rated voltage Up to 400 V, (3-pole) / 690 V, (4-pole) / 500 V, (5-pole) AC Rated current 63 A Frequency Up to400 Hz Rated making / rated breaking capacity AC-3 accd. EN 60947-3 U e 690 V / I e 63 A External back up fuse Without thermal protection 63 A with thermal protection 80 A gg (rated current 63 A set to) Protection class accd. to EN 60598 I Degree of protection accd. to EN 60529 IP66 Enclosure colour Black Cable entry / enclosure drilling 1 x M50 cable gland, 1 x M50 Ex-screw plug plastic or 2 x M40 metal thread with 2 Ex-screw plug plastic Terminals 2 x 4-25 mm 2 / with ring cable lug 2) 1 x 35 mm 2 Enclosure material Glass fibre reinforced polyester cable gland Ø 19-34 mm Terminals 1 x 4-16 mm 2, cable lug 3) 1 x 25 mm 2 Enclosure material Polyamide 2) use supplied cable lugs 3) see accessories www.crouse-hinds.de EATON 2.1.7

Ex-plugs & receptacles 63 A 4- and 5-pole up to 690 V cap Ordering details Voltage h Type Aux. contact Cable entry Weight ca, Low temp. -55 C up to +40 C Type 63 A 4-pole 200-250 V 380-415 V 480-500 V 600-690 V Type 63 A 5-pole 200-250 V 380-415 V 9 h 6 h 7 h 5 h 6 h High temp. Order No. -25 C up to +55 C KU 8.1 kg X GHG 514 4409 R0001 ME 8.2 kg X GHG 514 4409 R3001 ME 8.2 kg X GHG 514 4409 R3101 0.9 kg X X GHG 514 7409 R0001 KU 8.1 kg X GHG 514 4406 R0001 ME 8.2 kg X GHG 514 4406 R3001 ME 8.2 kg X GHG 514 4406 R3101 GM 8.2 kg X GHG 514 4406 R3003 GM 8.2 kg X GHG 514 4406 R3103 0.9 kg X X GHG 514 7406 R0001 KU 8.1 kg X GHG 514 4407 R0001 ME 8.2 kg X GHG 514 4407 R3001 ME 8.2 kg X GHG 514 4407 R3101 GM 8.2 kg X GHG 514 4407 R3003 GM 8.2 kg X GHG 514 4407 R3103 0.9 kg X X GHG 514 7407 R0001 KU 8.1 kg X GHG 514 4405 R0001 ME 8.2 kg X GHG 514 4405 R3002 ME 8.2 kg X GHG 514 4405 R3102 0.9 kg X X GHG 514 7405 R0001 KU 8.1 kg X GHG 514 4506 R0001 ME 8.2 kg X GHG 514 4506 R3001 ja ME 8.2 kg X GHG 514 4506 R3101 GM 8.2 kg X GHG 514 4506 R3018 GM 8.2 kg X GHG 514 4506 R3118 0.9 kg X X GHG 514 7506 R0001 Other voltage ranges and versions available on request, KU = 1 x plastic-cable gland M25, 1 x M25 Ex-screw plug plastic ME = 2 x metal thread M20 GE = 2 x plastic thread M20 without cable gland/screw plug GM = 2 x metal thread M20 with screw plug, with external earth bolt M6 2.1.8 EATON www.crouse-hinds.de

Ex-plugs & receptacles 63 A 4- and 5-pole up to 690 V Dimension drawing I Wiring diagram 200 X184 10 226 9 wall socket 4/5-pole X = fixing dimensions plug 4/5-pole Dimensions in mm Ø 110 475 370 X276 ca. 272 without L1 L2 L3 PE with L1 L2 L3 13 N PE without L1 L2 L3 N PE with L1 L2 L3 13 N PE 3P + PE 14 3P + AUX + PE 3P + N + PE 14 3P + N + AUX + PE www.crouse-hinds.de EATON 2.1.9

Eaton s Crouse-Hinds Business The safety you rely on. See the complete offering of Hazardous and Industrial Products at www.crouse-hinds.de. U.S. (Global Headquarters): Eaton's Crouse-Hinds Business 1201 Wolf Street Syracuse, NY 13208 (866) 764-5454 FAX: (315) 477-5179 FAX Orders Only: (866) 653-0640 CrouseCustomerCTR@Eaton.com For more information: If further assistance is required, please contact an authorized Eaton Distributor, Sales Office, or Customer Service Department. Australia Phone +61-2-8787-2777 Fax +61-2-9609-2342 crousehindsanz@eaton.com China Phone +86-21-2899-3600 Fax +86-21-2899-4055 ECHsales@eaton.com Great Britain Phone +44-247-630-89 30 Fax +44-247-630-10 27 sales5@eaton.com India Phone +91-124-4683888 Fax +91-124-4683899 cchindia@eaton.com Canada Toll Free +1-800-265-0502 Fax +1-800-263-9504 Fax orders only: +1-866-653-0645 Korea Phone +82-2-3484-6783 Fax +82-2-3484-6778 CCHK-sales@ cooperindustries.com Mexico/Latin America/ Caribbean Phone +52-555-804-4000 Fax +52-555-804-4020 mxmercadotecnia@ cooperindustries.com Spain Phone +34-9-37362710 Fax +34-9-37835055 sales.cch.es@ cooperindustries.com Middle East (Dubai) Phone +971-4-427-2522 / 2500 Fax +971-4-429-8521 CHMEsales@Eaton.com The Netherlands Phone +31-10-2452145 Fax +31-10-2452121 CHRD_mail@Eaton.com Norway Phone +47-32-244600 Fax +47-32-244646 CHLIoffice@eaton.com Singapore: Phone +65-6645-9888 Fax +65-6297-4819 CHSI-Sales@Eaton.com Turkey Phone +90-216-464-20-20 Fax +90-216-464-20-10 infoegturkey@eaton.com Russia Phone +7-495 510-24-27 Fax +7-495 510-24-28 info@cooper.ru.com www.cooper-russia.ru Eaton s Crouse-Hinds Business Neuer Weg Nord 49 D-69412 Eberbach Phone +49 (0) 6271/806-500 Fax +49 (0) 6271/806-476 E-mail info-ex@eaton.com Internet www.crouse-hinds.de Eaton 1000 Eaton Boulevard Cleveland, OH 44122 United States Eaton.com Changes to the products, to the information contained in this document, and to prices are reserved; so are errors and omissions. Only order confirmations and technical documentation by Eaton is binding. Photos and pictures also do not warrant a specific layout or functionality. Their use in whatever form is subject to prior approval by Eaton. The same applies to Trademarks (especially Eaton, Moeller, and Cutler-Hammer). The Terms and Conditions of Eaton apply, as referenced on Eaton Internet pages and Eaton order confirmations. 2016 Eaton Corporation All Rights Reserved Printed in Germany Publication No. BR 300 8000 September 2016 Eaton s Crouse-Hinds Business 1201 Wolf Street Syracuse, NY 13208 (866) 764-5454 CrouseCustomerCTR@Eaton.com Eaton is a registered trademark. All other trademarks are property of their respective owners. 2.1.10 EATON www.crouse-hinds.de