The NGAL Test Application Note for Abbott Architect c8000

Similar documents
The NGAL Test Application Note for Roche Modular P

Beckman Coulter System Reagent, AU400/AU400 e AMPHETAMINES EMIT II PLUS, Semi-Quantitative (500 ng/ml Cutoff) Cat. No.: OSR9C229 Reagent ID: 520

Beckman Coulter System Reagent, AU400/AU400 e ETHYL ALCOHOL EMIT II PLUS Cat. No.: OSR9K229 Reagent ID: 524

QMS AMIKACIN ASSAY APPLICATION Beckman Coulter AU400, AU480, AU640, AU680, AU2700, AU5400, AU5800

DRI ETHYL ALCOHOL ASSAY APPLICATION Beckman Coulter AU400, AU480, AU640, AU680, AU2700, AU5400, AU5800

Beckman Coulter System Reagent, AU400/AU400 e URINE GLUCOSE Cat. No.: OSR6x21 Reagent ID: 021

Beckman Coulter System Reagent, AU400/AU400 e URINE CALCIUM ARSENAZO Cat. No.: OSR6x117 Reagent ID: 117

Beckman Coulter System Reagent, AU400/AU400 e URINE CREATININE Cat. No.: OSR6x78 Reagent ID: 078

DRI METHADONE METABOLITE ASSAY APPLICATION BECKMAN COULTER AU400, AU480, AU640, AU680, AU2700, AU5400, AU5800

Beckman Coulter System Reagent, AU400/AU400 e LITHIUM Cat. No.: OSRT056 Reagent ID: 600

Beckman Coulter System Reagent, AU400/AU400e URINE AMYLASE Cat. No.: OSR6x06 Reagent ID: 006

DRI CREATININE-DETECT APPLICATION BECKMAN COULTER AU640, AU680

DRI OXYCODONE APPLICATION BECKMAN COULTER AU480, AU680, AU5800

CEDIA METHADONE APPLICATION Beckman Coulter AU480 & AU680

CEDIA BARBITURATES APPLICATION Beckman Coulter AU480, AU680

DRI ph-detect APPLICATION BECKMAN COULTER AU640, AU680

Beckman Coulter System Reagent, AU400/AU400 e ACETAMINOPHEN EMIT tox TM Cat. No.: OSR7A229 Reagent ID: 517

Beckman Coulter System Reagent, AU400/AU400 e METHOTREXATE EMIT Cat. No.: SYVA 6L119 Reagent ID:

Beckman Coulter System Reagent, AU400/AU400 e THYROXINE (T4) Cat. No.: Microgenics Cat. No Reagent ID: #

Beckman Coulter System Reagent, AU400/AU400 e ALKALINE PHOSPHATASE (IFCC) Cat. No.: OSR6x04 Reagent ID: 004

BICARBONATE (CO2), AU400/AU400 e System reagent: OSR6x37 Reagent ID: 037

Protein Quantification Kit (BCA Assay)

Reference Guide for the Value Assignment Web v

LIGHT SOURCE Quartz-iodine lamp 12V-20W.

BCA protein assay kit for low concentrations. For measuring total protein concentration of pure proteins, extracts or lysates.

4 plate fully automated ELISA analyzer Reagent system. Open (Human tests predefined) Throughput (max.) Up to 7 plates / run Reaction / reading system

UV-6 Series Double Beam UV/Vis Spectrophotometers

ab BCA protein assay kit reducing agent compatible (test tube)

E21 Alarm List E Photometric Data Error (A) 3117 Lamp Off Error 3118 Lamp Dark Error 3120 Sample Probe (FA) Error (Up-Down) (A, B)[A, B, C, D

FULLY AUTOMATED 2 MICROPLATE ANALYZER

Product Correction Urgent Immediate Action Required

1 plate fully automated ELISA analyzer Reagent system. Open (Human tests predefined) Throughput (Max.) 1 plate /run Barcode reader

COBAS INTEGRA 400 plus

Procedure of calculation step-by-step with an example of our insulin assay data

ELECTIVES MODULES. Implement. Electives. Setup. Troubleshooting. Basics

Electrophoresis File Run Summary

FACA-1240 Auto Chemistry Analyzer User s Manual

UV / VIS SPECTROPHOTOMETER

Novaspec Pro User Manual

WIZ Panel SOFTWARE OPERATING MANUAL. Verified: TM X

FAQs: Quality Systems Manual (QSM) Version 5.0

Data Sheet. Item Specification Comment

StudyDoc Report Writing Manager

NanoPhotometer TM USER MANUAL Version 2.0

BIOWAVE DNA USER MANUAL

RIDASCREEN Aflatoxin M1

NANO SPECTROPHOTOMETER

CHLORINE DIOXIDE (0 to 5.00 mg/l) Method 10126

Phone:

MAKE THE CHANGE FOR BETTER NEONATAL SCREENING. Introducing the new AutoDELFIA immunoassay system for newborn screening

6 th International Conference on Applied Informatics Eger, Hungary, January 27 31, MMA Technology. Robert Tornai

NEW IMPROVED SCREENING PLATFORM MATERNAL FETAL HEALTH

MAKE THE CHANGE FOR BETTER NEONATAL SCREENING. Introducing the new AutoDELFIA immunoassay system for newborn screening

John Calleja Melbourne Pathology Services. Gold Coast 20th Sept 2013

Determination of suppressor with CVS using the calibration technique «smartdt» with dynamic addition volumes

Determination of suppressor with CVS using the calibration technique smartdt with dynamic addition volumes

Revelation Program User Manual

Version 1.1 March 2017

BOECO MODEL S-30 LIFE SCIENCE ANALYSER OPERATING MANUAL

ADVIA 360, ADVIA 560, and ADVIA 560 AL Systems

Blood Hemolysis Detector User Manual

Validation of a Direct Analysis in Real Time Mass Spectrometry (DART-MS) Method for the Quantitation of Six Carbon Sugar in Saccharification Matrix

Lab ID 406. Your Parameters. Institution: Analyte. WBC Siemens Advia 120 Siemens 10 9 /L. RBC Siemens Advia 120 Siemens /L

Harris: Quantitative Chemical Analysis, Eight Edition CHAPTER 05: QUALITY ASSURANCE AND CALIBRATION METHODS

Microplate Readers INSTRUMENTS. Description Catalog # Description DAR800 SF2100 SF4700

Policy # MI_SER_GAL Department of Microbiology. Page Quality Manual TABLE OF CONTENTS

QAM-I-102 Operation and Calibration of the Autoanalyzer

Gen5 & Gen5 Secure User's Guide

Use the AccuSEQ Software v2.0 Custom Experiment mode

GENOVA MK3 LIFE SCIENCE ANALYSER OPERATING MANUAL

Skyla VB1 Quick Reference Guide

TL6 Ultra Micro-volume Spectrophotometer

S800 Spectrawave Visible Diode Array Spectrophotometer

Radiometer AQT90 FLEX Troponin I ERROR CODES

Semi-auto Chemistry Analyzer User s Manual SACA-19900

µl Spectrophotometer USER MANUAL

Abacus plus. Hematology Analyzer. User s Manual release

Declaration of Conformity

Model 680 Microplate Reader Instruction Manual Catalog Numbers

User s Manual. TBS-380 Mini-Fluorometer. Operating Manual. Dated: 08/14/2007 Rev. E

UM-AJV Abacus Junior Vet User s Manual

All About PlexSet Technology Data Analysis in nsolver Software

DSX Automated ELISA System

CH142 Spring Spectrophotometers with Vernier Data Acquisition Software

MILLIPLEX Analyst User Guide V 3.4

QuantiFERON -TB Gold In-Tube (v2.17.3*) Analysis Software Instructional Guide

QUICKStart Guide APT Versions 3.0 through 3.3

Hematology Analyzer. User s Manual. Revision 2.17

TOSOH CORPORATION BIOSCIENCE DIVISION

Troubleshooting Guide

Diving into a new dimension: Quality meets efficiency

VersaWave. Technical Specification

Tech Note. Estimating Relative Potency for CVB using Gen5 Software. Background

Error-Bar Charts from Summary Data

Microplate Systems. Absorbance Microplate Readers 366. Performance Validation and Software Tools 368. Microplate Washer 370

The Detection Flags and Primary Flags Fields in QuanLynx and TargetLynx Version 4.1

Curve Correction in Atomic Absorption

Thermo Scientific Multiskan FC User Manual

myvirena.com Training Guide

LABIntegrity StudyDoc Change Description Page 1 of 19. This bug has been fixed.

Transcription:

The NGAL Test Application Note for Abbott Architect c8 General parameters Name: NGAL Assay number: *1 Assay version: 1 Assay type: Photometric Assay availability: Enabled Cal version: 1 Reaction definition Reaction mode: End Up Main read time: 27-28 Primary wavelength: 572 Secondary wavelength: Color correction read time: - Last read required: 33 Blank read time: 19-2 Absorbance range:. -. blank type: Blank assay: Self blank Reagent/ Reagent: NGAL R1 reagent volume: 12 R1 water volume: R1 dispense mode: Type Diluent name: Saline R2 reagent volume: R2 water volume: R2 dispense mode: Diluent dispense mode: 4 Type Type Dilution name volume Diluted sample Diluent volume Water volume Dilution factor volume Normal 1 : 1, Rerun 1 15, 15, 1 : 8, Rerun 2 6, 1 : 1, Validity checks Reaction check type: Rate RATIO Read time A range: 32-33 Read time B range: 19 - Calculation limit:,1-9,9 Minimum absorbance: Rate linearity %:,15 Maximum absobance variation: 2 *1: To be defined by operator. Version: 1 Revision date: 3.1.211 The NGAL Test Application Note for Abbott Architect c8 Page 1 of 7

Calibration parameters Calibration method: Spline Use cal factor from: Factor: Full interval hours: Adjustment interval hours: Adjustment type: None Adjustment level: Expected cal factor:, Default ordering type: Full Expected factor tolerence %:, Blank absorbance range:. -. Span: Span absorbance range:, -, Maximum curve fit:, set name: *1 Replicates: 3 Cal level Concentration volume Diluted sample Diluent volume Water volume volume Blank Cal.1 Cal.2 Cal.3 Cal.4 Cal.5 15 6 15 3 5 Smart wash Cal level Reagent/Assay Wash Volume Replicates Wash protocol Results parameters Flag range specification: Linearity range: 25-5 Gender Age Normal range Extreme range - - Interpretation parameters Result units Result concentration unit: Result decimal places: ng/ml Correlation factor: Intercept: 1,, *1: To be defined by operator. The Application Note applies to the quantitative determination of NGAL in human urine and EDTA plasma. The performance data shown were obtained by the manufacturer. Each individual laboratory should validate its test system. Version: 1 Revision date: 3.1.211 The NGAL Test Application Note for Abbott Architect c8 Page 2 of 7

Performance for NGAL Test Reagent Kit Sensitivity Reagent calibrator instrument parameter Lot. RD23,3,25,2 The NGAL Test Lot.RD23 Abbott Architect c8 2.4/12/4 P19-2/27-28 572nm Spline ng/ml 15 ng/ml 6 ng/ml 15 ng/ml 3 ng/ml 5 ng/ml -,6,141,627,158,2341,2826 Unit:delta Abs Calibration Curve ng/ml -,3 15 ng/ml 151, 6 ng/ml 66,7 15 ng/ml 1515,3 3 ng/ml 334,7 5 ng/ml 5, delta Abs,15,1,5, ng/ml 1 ng/ml 2 ng/ml 3 ng/ml 4 ng/ml 5 ng/ml NGAL conc. [ng/ml] Recovery ng/ml - 15 ng/ml 11% 6 ng/ml 11% 15 ng/ml 11% 3 ng/ml 11% 5 ng/ml 1% Re-run Normal 4773, Re-run 413,5 (Saline) Recovery 87% Re-run-2 4556,5 ( diluent) Recovery 95% Version: 1 Revision date: 3.1.211 The NGAL Test Performance on Abbott Architect c8 Page 3 of 7

Within Run Imprecision / Specificity Reagent QC fluid -25ng/mL / Control Low,High / QC Panel Low, The NGAL Test Lot.RD23 Abbott Architect c8 2.4/12/4 P19-2/27-28 572nm Spline QC Fluid Control Low Control High Specificity 25ng/mL Lot.1831 Lot.1831 1 18 22 52 H917 Architect c8 Recovery 2 26 22 5 Control Low 194,9 29,4 17% 3 22 21 51 Control High 485,2 59,1 15% 4 24 29 59 Panel Low 11,2 121,9 111% 5 3 219 58 Panel Medium 313,4 341,7 19% 6 28 28 511 Panel High 873,2 951,9 19% 7 26 22 59 8 3 21 519 9 24 24 55 1 26 21 59 11 23 - - 12 25 - - 13 29 - - 14 27 - - 15 24 - - 16 26 - - 17 23 - - 18 26 - - 19 29 - - 2 18 - - N 2 1 1 Mean 25,2 29,4 59,1 Max 3, 22, 52, Min 18, 22, 5, SD 3,3811 6,239 6,5566 CV% 13,42% 2,96% 1,29% Version: 1 Revision date: 3.1.211 The NGAL Test Performance on Abbott Architect c8 Page 4 of 7

Linearity ~ 15ng/mL Dilution Saline, diluent Abbott Architect c8 2.4/12/4 P19-2/27-28 572nm Spline 15 1 5 5 1 15 Dil.levels Theoretical Measured Recovery Dil.levels Theoretical Measured Recovery 15ng/mL - Saline 15ng/mL - diluent 1,,, 2, 1,,, 2,5 9, 1, 15, 128, 85% 9, 1, 15, 158, 15% 8, 2, 3, 269,5 9% 8, 2, 3, 39,5 13% 7, 3, 45, 426, 95% 7, 3, 45, 457, 12% 6, 4, 6, 569,5 95% 6, 4, 6, 611,5 12% 5, 5, 75, 735, 98% 5, 5, 75, 762, 12% 4, 6, 9, 879,5 98% 4, 6, 9, 922, 12% 3, 7, 15, 138, 99% 3, 7, 15, 171, 12% 2, 8, 12, 1191, 99% 2, 8, 12, 1227,5 12% 1, 9, 135, 1334, 99% 1, 9, 135, 1375, 12%, 1, 15, 1491,5 99%, 1, 15, 1523,5 12% 15 1 5 5 1 15 Version: 1 Revision date: 3.1.211 The NGAL Test Performance on Abbott Architect c8 Page 5 of 7

Linearity ~ 5ng/mL & Prozone Dilution 6 4 2, QC fluid Saline, diluent Abbott Architect c8 2.4/12/4 P19-2/27-28 572nm Spline 2 4 6 6 4 2 2 4 6 Dil.levels Theoretical Measured Recovery Dil.levels Theoretical Measured Recovery Dil.levels Theoretical Measured Mark 5ng/mL - Saline 5ng/mL - diluent Prozone - diluent 1,,, -5, 1,,, 5, 1,,,, 9, 1, 5, 446,5 89% 9, 1, 5, 55,5 11% 9, 1, 4 4196, 8, 2, 1, 884, 88% 8, 2, 1, 126,5 13% 8, 2, 8 5, >5 7, 3, 15, 1395,5 93% 7, 3, 15, 1518,5 11% 7, 3, 12 5, >5 6, 4, 2, 1925, 96% 6, 4, 2, 222, 11% 6, 4, 16 5, >5 5, 5, 25, 2468, 99% 5, 5, 25, 2541,5 12% 5, 5, 2 Error 4, 6, 3, 2994, 1% 4, 6, 3, 352, 12% 4, 6, 24 Error 3, 7, 35, 3525, 11% 3, 7, 35, 3617, 13% 3, 7, 28 Error 2, 8, 4, 438,5 11% 2, 8, 4, 4152, 14% 2, 8, 32 Error 1, 9, 45, 4618, 13% 1, 9, 45, 4661,5 14% 1, 9, 36 Error, 1, 5, 4998,5 1%, 1, 5, 5, 1%, 1, 4 Error 4 5 5 8 6 4 2 1 2 3 4 Version: 1 Revision date: 3.1.211 The NGAL Test Performance on Abbott Architect c8 Page 6 of 7

Interferences Dilution Hemoglobin, Bilirubin, Intrafat diluent Abbott Architect c8 2.4/12/4 P19-2/27-28 572nm Spline Hemoglobin: C-Bilirubin: F-Bilirubin: Intrafat: 2% 2% 2% 2% 1% % -1% 1% % -1% 1% % -1% 1% % -1% -2% 1 2 3 4 5 Hemoglobin [mg/dl] -2% 6 12 18 24 3 C-Bilirubin [dg/ml] -2% 6 12 18 24 3 F-Bilirubin [dg/ml] mg/ml Deviation mg/ml Deviation mg/ml Deviation %,%,%,% 1-1,1% 6,% 6 -,6% 1 2 -,6% 12,2% 12,5% 2 3-1,3% 18,5% 18 1,3% 3 4-1,7% 24 1,1% 24 % 4 5,3% 3 3,2% 3 2,7% 5-2% 1 2 3 4 5 Intrafat [%] Deviation,% 1,1% 2,3% 1,8%,8% -,3% Version: 1 Revision date: 3.1.211 The NGAL Test Performance on Abbott Architect c8 Page 7 of 7