DI-154RS DI-195B. User's Manual. The way PC-based instrumentation should be. 4-Channel Data Acquisition Module

Similar documents
DI-148U. User's Manual. The way PC-based instrumentation should be. 8-Channel USB Data Acquisition Starter Kit. Manual Revision B

DI-148U DI-148U-SP. DI-158 Series. User's Manual. The way PC-based instrumentation should be. 8-Channel USB Data Acquisition Starter Kit

DI-148U DI-148U-SP. DI-158 Series. User's Manual. The way PC-based instrumentation should be. 8-Channel USB Data Acquisition Starter Kit

DI User's Manual. The way PC-based instrumentation should be. 8-Channel USB Data Acquisition Starter Kit. Manual Revision B

The way PC-based instrumentation should be

DI-2108-P. User's Manual. The way PC-based instrumentation should be. 8-Channel High Speed USB Data Acquisition System with Programmable Gain

DI-4108 and DI User's Manual. The way PC-based instrumentation should be

DI User's Manual. The way PC-based instrumentation should be. 8-Channel USB Voltage and Thermocouple Data Acquisition System.

DI-718B Series. DI-718Bx Series. User's Manual. The way PC-based instrumentation should be. 8 Channel Data Logger with Signal-Conditioned Inputs

Installation Guide. Installation Instructions for Models: DI-148 Series DI-158 Series DI-710 Series DI-715B Series DI-718B(x) Series.

WINDAQ Acquisition. ActiveX Controls and XControls

ADAM-5511 Quick Start

TB-100 ControLynx Terminal Block

INSTALLATION INSTRUCTIONS 5" SINGLE CHANNEL ULTIMATE TACH

PRODUCT CONTENTS... 3 II. REQUIRED MATERIALS... 3 III. OVERVIEW... 3 IV. BENCH LAYOUT...

SCIENCEWORKSHOP 750 INTERFACE. Instruction Sheet for the PASCO Model CI Introduction

DI-788 Data Acquistion System

PCI Serial Card 2 Port RS-422/RS-485 PCI Serial Card with Terminal Block Connectors PCI2S422TB Instruction Manual Actual product may vary from photo

ANC Series RS-422 Serial Communications Adapter

Instruction Manual. Balanced Audio Upgrade Installation. iport IW-21/IW-22 Upgrade Kits. Balanced Audio Upgrade Kit. (iport IW-21)

DCM Digital Control Modules

SIAC-PS 3G SIGNAL ISOLATOR WITH POWER SUPPLY (PART NO. 8890) INSTALLATION INSTRUCTIONS

62533 Ethernet Adapter

I/O SIGNAL CONDITIONER

G-RAID 2 Installation Guide

MODEL No. SW1X8 RS422 SWITCHER

DIN-191 and DIN-192 SERIES CONVERTER BOXES USERS MANUAL

Secured Series: Hub Plus Kit Single Door Controller Package Installation Manual

USER MANUAL. MODEL 1225 ParaLink TM Parallel Short Range Modem. SALES OFFICE (301) TECHNICAL SUPPORT (301)

Industrial Ethernet Ethernet to Serial Gateways Ethernet to Serial Converters for Modbus, Red lion and other protocols

EASON TECHNOLOGY. IO8 & IO24 Break-Out Module

Owner s Manual. TSD-DCPDV DC Power Distribution with Fixed & Variable Outputs. TSD-DCPDV DC Power Distribution. AtlasSound.com

MODEL USB-DA12-8E Eight Channel Digital to Analog Converter USER MANUAL

SA SERIES Arlingate Lane, Columbus, Ohio (614)

OP8/16 Optoisolated Digital Input Board User's Manual

OPERATING AND SERVICE MANUAL. Universal Interface Device 47

OPERATING AND SERVICE MANUAL. Universal Interface Device 47

WR-5e Remote Control

ACLD Channel Opto-isolated Digital Input Board

Owner s Manual. TSD-DCPDV DC Power Distribution with Fixed & Variable Outputs. TSD-DCPDV DC Power Distribution. AtlasIED.com

User Guide. DMXSM-H18 Splitter. DMXSM-H81 Merger. Document Release Aug Revision B

Resolver to Digital Expansion Board

R & D SPECIALTIES SERIES 100 RO CONTROLLER USERS MANUAL. 2004, by R & D Specialties, Inc. All Rights Reserved.

Transport Pro FireWire and USB Portable Hard Drive

DCS-E 1kW Series, DLM-E 3kW & 4kW Power Supplies

PWRcheck Spring City Drive Waukesha, WI

Data Acquisition Software and Hardware Demonstration Guide

DataPort 250 USB 2.0 Enclosure User s Guide (800)

Model P4017 Single Channel USB Oscilloscope. Quick Start Guide

PV3500. Fuel Site Controller. Service Manual OPW Fuel Management Systems Manual M Rev. 1

FA-2448 SIX POSITION Filter Wheel

User Guide DMX TESTER

Model GX-2001 Data Logging Software. User s Guide

OPERATING INSTRUCTIONS FOR MODEL ST-15 5-DIGIT SPORTS TIMER

TDM-150 TIMER DISPLAY

SATA II HDD Canister KISS DA 435 Quick Reference Guide

PCLD-8751 PCLD User Manual

OPERATIONS MANUAL PCM-DOC

Bluetooth USB User Guide. Revision A July 12, 2006 Part Number GC

ES-600 Ozone Controller Operation Manual

AirPro Surveyor 2 Manual

COBALT C INSTALLATION GUIDE RFID CONTROLLER ESCORT MEMORY SYSTEMS. High Frequency Passive Radio Frequency Identification Controller

Data Acquisition. Software and Hardware. Demonstration Guide. For: NetDAQ Logger for Windows Hydra Logger for Windows Trend Link for Fluke

TDM-170 TIMER DISPLAY

SC-9

DV-HDA-12AUD 1x2 HDMI Distribution Amplifier Manual

RS422 PORT SWITCHER REMOTE CONTROL PANEL

Signatech. Intensity Controller Manual MS210 / MS220 / CS410 / CS420

CHAPTER 2 CHAPTER 1 INTRODUCTION

User's Guide. MiniTec TM Series Model MN25 MultiMeter

SLUG DATA-LOGGER MANUAL. YieldPoint Inc. JULY 2009

Omnitron Systems Technology, Inc. 1. iconverter. 19-Module Managed Power Chassis User s Manual

HydroLynx Systems, Inc. Model 50386D Decoder Instruction Manual

Ashly WR-5 Remote Control

Woolich Racing. USB ECU Interface User Guide

Model 282 Total Interface Isolation Module Reference Manual Rev. A Print Table of Contents 1.0 General Description 2.

User Guide. Model Temperature Datalogger Kit Model Temperature and Humidity Datalogger Kit Model SW276 Datalogging Software SW276

Instruction Guide. 2 Channel Ultra ATA/100 PCI Card PCI2IDE100. The Professionals Source For Hard-to-Find Computer Parts. Revised: December 5, 2002

OPERATION MANUAL. Decision Group Inc. SMARTLAB USB 16 CHANNELS RELAY OUTPUT 16 CHANNELS PHOTO ISOLATOR INPUT BOARD

MusicTel-Net/Net+ Installation and Operation Manual

CTI 2551-A 8-CHANNEL ISOLATED THERMOCOUPLE INPUT MODULE INSTALLATION AND OPERATION GUIDE. Version 1.3 CTI Part # * *

JTAGjet. series SIGNUM SYSTEMS CORPORATION. USB 2.0 Driver for JTAGjet and ADM51. Installation Instructions

Serial Converters WTS 1201/-CP. RS-232 to IEEE b Wireless Converter with WEP Encryption, and External Antenna

Quick Start Guide. Model 0260 Secondary Electronics

Eco Sensors OZONE CONTROLLER Model OS-6 Instructions for Use. General and New Features

Power Quality Recorder

Universal Switch Panel USP-KEYSERVER. User Manual

Integrated Stepper Drive & Motor

AMAX-2750SY Series. 32-ch AMONet RS-485 Isolated Digital I/O Slave Modules. User Manual

Page/Talk Industrial Desk Sets

PMDX-108-Output. 8-Channel Isolated Output Board for PC parallel port pins 2-9. User s Manual

4-Channel Thermometer

MPP200 User s Manual

Excelis HD QUICK START GUIDE. 73 Mall Drive, Commack, NY (P)

EDG Port Industrial 10/100 Mbps Ethernet Switch. User Manual

LPG STM 94442A User s Manual

MULTIPLEXER MX4. Operation and Installation Manual. Pacific Micro Systems

LB-HDMI/DE LINK BRIDGE TM HDMI AUDIO DE-EMBEDDER SYSTEM

PIM-Mini Pulsed Current Source Operation Manual

User Manual. For more information, visit

Transcription:

The way PC-based instrumentation should be DI-154RS 4-Channel Data Acquisition Module DI-195B 2-Channel Serial Port I/O Module with Signal Conditioned Inputs User's Manual Manual Revision L Software Release Level 1 Copyright 2005 by DATAQ Instruments, Inc. The Information contained herein is the exclusive property of DATAQ Instruments, Inc., except as otherwise indicated and shall not be reproduced, transmitted, transcribed, stored in a retrieval system, or translated into any human or computer language, in any form or by any means, electronic, mechanical, magnetic, optical, chemical, manual, or otherwise without expressed written authorization from the company. The distribution of this material outside the company may occur only as authorized by the company in writing. DATAQ Instruments' hardware and software products are not designed to be used in the diagnosis and treatment of humans, nor are they to be used as critical components in any life-support systems whose failure to perform can reasonably be expected to cause significant injury to humans. 241 Springside Dr. Akron, Ohio 44333 U.S.A. Telephone: 330-668-1444 Fax: 330-666-5434 Designed and manufactured in the United States of America

Warranty and Service Policy Product Warranty DATAQ Instruments, Inc. warrants that this hardware will be free from defects in materials and workmanship under normal use and service for a period of 90 days from the date of shipment. DATAQ Instruments' obligations under this warranty shall not arise until the defective material is shipped freight prepaid to DATAQ Instruments. The only responsibility of DATAQ Instruments under this warranty is to repair or replace, at its discretion and on a free of charge basis, the defective material. This warranty does not extend to products that have been repaired or altered by persons other than DATAQ Instruments employees, or products that have been subjected to misuse, neglect, improper installation, or accident. DATAQ Instruments shall have no liability for incidental or consequential damages of any kind arising out of the sale, installation, or use of its products. Service Policy 1. All products returned to DATAQ Instruments for service, regardless of warranty status, must be on a freight-prepaid basis. 2. DATAQ Instruments will repair or replace any defective product within 5 days of its receipt. 3. For in-warranty repairs, DATAQ Instruments will return repaired items to the buyer freight prepaid. Out of warranty repairs will be returned with freight prepaid and added to the service invoice.

Table of Contents DI-154RS/DI-195B User s Manual Warranty and Service Policy... iii 1. Introduction... 1 DI-154RS... 1 DI-195B... 1 WINDAQ/Lite Waveform Recording Software and WINDAQ Waveform Browser Playback and Analysis Software... 1 Help... 1 Conventions Used in the Documentation... 2 General Conventions... 2 Mouse Conventions... 2 WinDaq Operating Modes... 2 2. Getting Started... 3 Installing the Hardware... 3 Installing WinDaq Software... 3 Menu Items Created During Installation... 4 3. Connecting Input Signals... 5 DI-154RS... 5 Input Signal Considerations... 6 DI-195B... 7 Input Signal Considerations... 7 Table of Contents v

DI-154RS/DI-195B User s Manual 1. Introduction This manual contains information designed to familiarize you with the features and functions of the DI-154RS and the DI-195B serial port data recording modules. DI-154RS The DI-154RS is a portable, four-channel data recording module that communicates through the computer s RS-232 (or serial) port. It can record data at rates of up to 240 samples per second with 12 bits of measurement accuracy. The DI-154RS is powered directly from the computer to which it is connected (through the RS-232 cable) and is equipped with four analog input channels and three digital input channels. DI-195B The DI-195B is a two-channel data recording module that communicates through the RS-232 (or serial) port. It can record data at rates of up to 240 samples per second with 12 bits of measurement accuracy. The DI-195B is powered by the included wall outlet-type adapter, which can be plugged into any single-phase, 120 volt, 60 Hz AC source. It features two, signal-conditioned, differential, bipolar analog inputs (screw terminal access, maximum measurement range is defined by the DI-5B modules). The DI-195B allows you to plug any two DI-5B signal conditioning modules into its backplane. The DI-5B signal conditioning modules then filter, isolate, amplify, and/or convert virtually any industrial signal that is applied into a high level analog voltage, perfectly suited for recording. WINDAQ/Lite Waveform Recording Software and WINDAQ Waveform Browser Playback and Analysis Software The WINDAQ software shipped with all DATAQ Instruments serial port products includes WINDAQ/Lite waveform recording software and WINDAQ Waveform Browser playback and analysis software. WINDAQ/Lite waveform recording software can be used to record waveforms directly and continuously to disk while monitoring a real time display of the waveforms on-screen. It operates and displays waveform signals in real time at the full sample rate of the instrument being used. WINDAQ/Lite is limited to a 240 Hz maximum throughput rate when recording to disk. WINDAQ Waveform Browser playback software (also known as WWB ) offers an easy way to review and analyze acquired waveforms. A built-in data file translator allows the user to display multiple waveforms acquired by WINDAQ/Lite or any of a wide range of data acquisition packages. The software s disk-streaming design allows data files of any length to be graphically displayed rapidly, in normal or reverse time directions. Seven standard cursorbased measurements, frequency domain, and statistical analysis functions help simplify waveform analysis and interpretation. Both WINDAQ/Lite and WINDAQ Waveform Browser are available for download free-of-charge from our web site (www.dataq.com). Click here to open the Fast Start guide to recording and reviewing waveforms. Help Both the WINDAQ/Lite and the WINDAQ Waveform Browser software utilize context-sensitive help. For help with any particular function, simply highlight the menu item in the WINDAQ software and press the F1 key. This will take you immediately to the help topic most relevant to that menu item. The help files may also be accessed through the Help menu in the Software. Help files are updated regularly and may be installed through our web site if desired. Introduction 1

DI-154RS/DI-195B User s Manual Conventions Used in the Documentation Before using WINDAQ software, please read this section to understand some of the terms and notational conventions used here and in the Help Files. General Conventions Commands you choose are given with the menu name preceding the command name. For example, the phrase Choose File Open tells you to choose the Open command from the File menu. This naming convention describes the sequence you follow in choosing a command - first you select the menu, then you choose the command. Mouse Conventions In general, most mouse actions require only the left mouse button. For example, carrying out a menu command or working in a dialog box requires only the left mouse button. Since the majority of mouse procedures are done with the left mouse button, we will not specify which mouse button to click, drag, or double-click in the procedure unless the action uses the RIGHT mouse button. For example, Double-click the right mouse button anywhere in the bottom annotation line to move the cursor to the lowest displayed waveform valley. Point means to position the mouse pointer until the tip of the pointer rests on what you want to point to on the screen. For example, Point to the View menu. Click means to press and immediately release the mouse button without moving the mouse. For example, To display the menu that contains the command you want, click the menu name in the menu bar. Double-click means to click the mouse button twice in rapid succession. For example, Double-click the icon to start the program. Drag means to press the mouse button and hold it down while you move the mouse; then release the button. For example, Drag down to Data Cursor to enabled the cursor for on-screen display. WINDAQ Operating Modes WINDAQ waveform recording software has three operating modes: Setup, Record, and Standby. Each operating mode shares many features with the other two, but specific modes may restrict features or disable some functions altogether. WINDAQ Recording Software starts in the SET UP operating mode. In SET UP mode you can configure data acquisition parameters such as the number of acquired channels, channel gain, and channel offset and customize the real time display. SET UP operating mode provides access to most data acquisition functions and adjustments including control of the real time display screen's scaling and offset functions. The SET UP mode displays data in real time but does not store data to disk. This mode limits sample rate only by the capabilities of the hardware. In other words, you can sample as fast as your instrument will allow. When in this mode, the Status: area of the bottom annotation line displays SET-UP. The RECORD operating mode stores, or streams, data to disk. Activate the RECORD mode by selecting Record from the File menu. You can use all waveform recording features and functions (with some restrictions) while in the RECORD mode except the following: Channel-specific operations (i.e., channel number, gain, offset) and sample rate adjustments. Waveform information continuously streams to disk while the real time display remains active. RECORD mode limits sample rate to 240 Hz maximum throughput when using WINDAQ/Lite but does not limit the sample rate when using WINDAQ/Pro or Pro+ (limit determined by hardware). When in RECORD mode, the Status: area of the bottom annotation line displays RECORD. Use the STANDBY operating mode to temporarily suspend (pause) waveform recording to disk. Select Stop in the File menu to enter STANDBY mode. You can use all waveform recording features and functions except channel-specific operations (i.e., channel number, offset, etc.) and sample rate adjustments. The STANDBY mode displays data in real time while waveform recording to disk has been stopped. When in this mode, the Status: area of the bottom annotation line displays STBY. Start and stop as many times as desired during a data acquisition session. Introduction 2

DI-154RS/DI-195B User s Manual 2. Getting Started The following items are included with each instrument purchase. Verify that you have the following: DI-154RS or DI-195B instrument. Communications cable designed to connect the instrument to your computer s serial port (the DI-195B AC power adapter is integrated into the serial cable). The WINDAQ Resource CD-ROM, which includes this documentation which covers the hardware aspects of the DI-154RS, and DI-195B serial port modules and also documents WINDAQ/Lite waveform recording software and WINDAQ Waveform Browser playback and analysis software. If you purchased a DI-195B, you should also have one or two DI-5B plug-in modules. Note that these are extracost items not included with the purchase of the DI-195B kit, but are required for operation. If an item is missing or damaged, call DATAQ Instruments at 330-668-1444. We will guide you through the appropriate steps for replacing missing or damaged items. Save the original packing material in the unlikely event that your unit must, for any reason, be sent back to DATAQ Instruments. Installing the Hardware NOTE: Before installing WINDAQ software, you should already have the hardware connected to the PC s serial port. Use the following procedure to connect the DI-154RS, or DI-195B module to your computer. DI-154RS and DI-195B Serial Port Connection: 1. Connect the male end of the communications cable to the 9-pin female connector on the DI-154RS or DI-195B module. 2. Connect the other end of the communications cable to your computer s serial or COM port. 3. If you purchased the DI-195B, plug the AC power adapter into any standard 120V, 60Hz wall outlet. Installing WINDAQ Software 1. Insert the WINDAQ Resource CD into your CD-ROM drive and close the drive tray. For most users, the Windows auto-run feature will automatically display a list of options. If you do not see this list of options after a reasonable period of time, double-click the My Computer icon on your desktop and then double-click your CD- ROM icon to manually display the list of options. 2. Choose the Install Software for Starter Kits (DI-154, DI-194, DI-195B) radio button and click OK. 3. Choose the Install WinDaq Starter Kit Software for the DI-154 or DI-195B radio button and click OK. 4. The Welcome dialog box allows you to cancel the installation. Click OK to continue. 5. Read the License agreement and either Accept and Continue to continue the installation or Do not accept and stop to cancel the installation. 6. Select the folder (default is C:\DATAQ) you would like to place the files in and click OK. 7. Specify the Starter Kit you are installing and click OK. Getting Started 3

DI-154RS/DI-195B User s Manual 8. Specify the COM port you have connected the Starter Kit to and click OK. Installing to a nonexistent COM Port or to an incorrect COM Port requires the software to be uninstalled and re-installed. 9. Select the Program Manager Group to save shortcuts to in the Windows Menu (default is WINDAQ) and click OK. 10. WINDAQ/XL may be installed in the WINDAQ/XL Software dialog box. WINDAQ/XL requires a key from DATAQ Instruments, Inc. Click Yes to install or No to continue. 11. Advanced CODAS Analysis Software may be installed in the Advanced CODAS Analysis Software dialog box. Advanced CODAS requires a key from DATAQ Instruments, Inc. Click Yes to install or No to continue. 12. Installation is complete. Click OK to exit the installation program. Both WINDAQ/Lite and WINDAQ Waveform Browser may be run from the Windows Menu as specified in Step 9 (default is Start > Programs > WINDAQ). Menu Items Created During Installation The Sample Files Folder contains 8 different sample files to illustrate the versatility of WINDAQ Software. These samples are WINDAQ Waveform Browser Files that can be measured, analyzed, and manipulated in any way that you please. The WINDAQ XY Viewer icon runs the XY Viewer software. This program allows the user to generate a multi-channel XY plot in real time. The WINDAQ Lite Data Acq DI-154 (or DI-195B) icon runs the WINDAQ/Lite Data Acquisition Software. The WINDAQ Waveform Browser icon runs the WINDAQ Waveform Browser Software. The DATAQ Web page icon links directly to the DATAQ Instruments, Inc. home page. The How to program DI1xx icon links to the UltimaSerial internet page providing information for programming the DI-1xx. The License icon provides the Software Agreement License in text format. The Meter icon runs the Meter software which may be run while WINDAQ/Lite is running. This program reports waveform data values in a digital display format. Getting Started 4

DI-154RS/DI-195B User s Manual 3. Connecting Input Signals To connect signals to the DI-154RS or DI-195B, insert the stripped end of a signal lead into the desired terminal directly under the screw. Tighten the pressure flap by rotating the screw clockwise with a small screwdriver. Make sure that the pressure flap tightens only against the signal wire and not the wire insulation. Do not overtighten. Tug gently on the signal lead to ensure that it is firmly secured. Loosen Screwdriver Tighten Pressure flap Signal lead DI-154RS All user connections are made to the 8-port screw terminal connector as follows: CH 1: Channel 1 analog input. CH 2: Channel 2 signal input. CH 3: Channel 3 signal input. CH 4: Channel 4 signal input. Connecting Input Signals 5

DI-154RS/DI-195B User s Manual Gnd: Signal ground. Dig 0: Digital input 0. Dig 1: Digital input 1. Dig 2: Digital input 2. Your DI-154RS comes with the on-board waveform generator configured to provide a sample input signal. The onboard waveform generator is enabled by connecting a jumper wire between the CH 1 and Dig 2 inputs. Input Signal Considerations The DI-154RS is not an isolated product. This means that it is susceptible to common mode voltages that could cause damage to the device. Such damage is not covered by the product s warranty. Please read the following carefully before using the product and do not hesitate to contact DATAQ Instruments if you have any questions. The DI-154RS can tolerate a maximum applied voltage of only ±20V peak without damage. Although you may be certain that the signal you want to measure is lower than this level, a common mode voltage (CMV) with an unknown value may combine with your signal of interest to exceed this ±20V limit. In such instances, the product will be damaged. Especially in heavy industrial application environments, you should verify that a CMV does not exist before connecting and using the DI-154RS. We suggest the following procedure: 1. Prepare the device under test (DUT) as though you were about to make measurements. This includes the connection of any relevant power supplies, computer connections, etc. Do not make ANY signal connections between your DUT and your data acquisition instrument. Connect the DI-154RS to the serial port of your PC. The field side where the input signal connection is made should not have anything connected to it at this time. 2. Test for the presence of a CMV using a digital volt meter (DVM) in the following manner (fig. 1): a. Connect one lead of the DVM to the shell of the GND terminal of the DI-154RS' input signal connector. b. Connect the other DVM lead to each of several points on your DUT: To the DUT's chassis ground connection; To the DUT's signal common; To the DUT's signal output. c. Measure and record the voltage you see in each of the measurements made in 2b using both the DC and AC settings of your DVM. d. Should any reading obtained in 2c exceed 15VDC or 10.6VRMS, DO NOT CONNECT SIGNALS to your data acquisition instrument. A common mode voltage exists that can potentially destroy the instrument. You must determine the source of the CMV and eliminate it before making any measurement. Feel free to contact DATAQ Instruments for guidance. Figure 1: DUT signal signal common chassis V To the GND terminal of the DI-154RS Connecting Input Signals 6

DI-154RS/DI-195B User s Manual DI-195B All user connections are made to the two, four-port screw terminal connectors. This connector not used (excitation and power is supplied by the wall outlet power adapter/serial communications cable). DATAQ INSTRUMENTS INC DI-195B REV A 1997 GND DIN GND PWR Channel 1 Inputs (EX = Excitation) Channel 2 Inputs (EX = Excitation) EX- IN- IN+ EX+ EX- IN- IN+ EX+ CH1 CH2 U1 U2 JP3 JP4 CHANNEL 1 D1 D2 D3 D4 CHANNEL 2 C1 C2 R1 R4 R2 R3 U3 C3 U4 U5 C9 + + C6 + C7 + C8 C5 Q1 Y1 + R5 C10 D6 R6 R7 D5 R8 R9 R10 + D7 U6 Q2 JP7 P1 C4 Connect male-end of serial communications cable here. Connect other end of serial communications cable to PC's COM port. Plug adapter into any standard 120V, 60Hz, single-phase outlet. IN+ and IN- are the signal input terminals for each channel. EX+ and EX- are excitation voltage outputs for those transducers that require excitation. Obviously, you'll want to tailor the DI-5B signal conditioning modules used in the instrument to the kind of input signals you wish to record. Input Signal Considerations Model DI-195B requires one or two 5B-style signal conditioning modules for proper operation. These modules provide a variety of input signal configurations, as defined by the specific module used. A common feature of all 5B modules is built-in input-to-output isolation. This feature allows the DI-195B to tolerate common mode voltages as high as 1000VDC or peak AC. Further, 5B-style modules will tolerate up to 240vrms normal mode voltage (applied continuously across the module's input terminals). The common mode and normal mode specs of 5B modules allow the 195B to tolerate a wide range of measurement abuse and still perform as expected, or at the very least, not fail. Connecting Input Signals 7

DATAQ Instruments, Inc. 241 Springside Drive Akron, Ohio 44333 Telephone: 330-668-1444 Fax: 330-666-5434 E-mail: support@dataq.com Direct Product Links (click on text to jump to page) Data Acquisition Data Logger Chart Recorder Thermocouple Oscilloscope