ITdumpsFree. Get free valid exam dumps and pass your exam test with confidence

Similar documents
NS0-180 netapp

Testpassport. Банк экзамен

Actual4Test. Actual4test - actual test exam dumps-pass for IT exams

Actual4Test. Actual4test - actual test exam dumps-pass for IT exams

NetApp. Number: NS0-156 Passing Score: 800 Time Limit: 120 min File Version: 1.0.

NS0-191 netapp. Number: NS0-191 Passing Score: 800 Time Limit: 120 min.

NetworkAppliance NS NetApp Certified Data Administrator, ONTAP.

PASS4TEST. IT Certification Guaranteed, The Easy Way! We offer free update service for one year

Exam Questions NS0-180

Exam Questions NS0-157

ns0-157 Passing Score: 700 Time Limit: 120 min File Version: 1.0

Netapp Exam NS0-157 NetApp Certified Data Administrator, Clustered Data ONTAP Version: 11.0 [ Total Questions: 302 ]

NS0-171.network appliance

FlexArray Virtualization

Clustered Data ONTAP 8.2

Exam Questions NS0-156

EXAM - NS NetApp Certified Implementation Engineer - SAN, Clustered Data ONTAP. Buy Full Product.

PASS4TEST. IT Certification Guaranteed, The Easy Way! We offer free update service for one year

NS Number: NS0-507 Passing Score: 800 Time Limit: 120 min File Version: NS0-507

Netapp Exam NS0-506 NetApp Certified Implementation Engineer - SAN, Clustered Data ONTAP Version: 6.0 [ Total Questions: 65 ]

Cluster Management Workflows for OnCommand System Manager

Network- Appliance EXAM - NS NetApp Certified Implementation Engineer - SAN, Cluster-Mode. Buy Full Product

Cluster Management Workflows for OnCommand System Manager

OnCommand Unified Manager 6.1 Administration Guide

Upgrading a single-controller FAS22xx system with internal storage to another single-controller system by copying volumes

NS0-506 Q&As NetApp Certified Implementation Engineer - SAN, Clustered Data ONTAP

A Thorough Introduction to 64-Bit Aggregates

Clustered Data ONTAP 8.3

EXAMGOOD QUESTION & ANSWER. Accurate study guides High passing rate! Exam Good provides update free of charge in one year!

Installation and Cluster Deployment Guide for KVM

NetApp NS0-156_formatted

High Availability and MetroCluster Configuration Guide For 7-Mode

OnCommand Unified Manager 6.1

Controller Hardware Upgrade Express Guide

Cluster Management Workflows for OnCommand System Manager

Outline: ONTAP 9 Cluster Administration and Data Protection Bundle (CDOTDP9)

Clustered Data ONTAP 8.2 High-Availability Configuration Guide

Clustered Data ONTAP 8.2

Installation and Cluster Deployment Guide for VMware

Installation and Cluster Deployment Guide

NetApp Encryption Power Guide

ITBraindumps. Latest IT Braindumps study guide

A Thorough Introduction to 64-Bit Aggregates

Exam Questions HPE0-S37

Abstract. Data Classification. Technical Report. Roy Scaife, NetApp Version March 2016 TR-4375

A. Both Node A and Node B will remain on line and all disk shelves will remain online.

OnCommand System Manager 3.1.2

Exam Name: VMware Certified Professional on vsphere 5 (Private Beta)

ONTAP 9 Cluster Administration. Course outline. Authorised Vendor e-learning. Guaranteed To Run. DR Digital Learning. Module 1: ONTAP Overview

How to Configure NVIDIA GPU M6 Cards with Citrix XenDesktop 7.7 and vsphere 6.0 in FlexPod Datacenter with Cisco B-Series Servers

NetApp Encryption Power Guide

StoreOnce 6500 (88TB) System Capacity Expansion Guide

NetApp Encryption Power Guide

MetroCluster IP Installation and Configuration Guide

PASS4TEST. IT Certification Guaranteed, The Easy Way! We offer free update service for one year

Installation and Cluster Deployment Guide for KVM

Disks and Aggregates Power Guide

OnCommand System Manager 3.1.1

Data ONTAP 7-Mode Administration (D7ADM)

Data ONTAP 8.2 Storage Management Guide For 7-Mode

NetApp AFF A700 Performance with Microsoft SQL Server 2014

Exam Questions ns0-507

FlexPod Express with Microsoft Windows 2016 Hyper-V and FAS2600

Testkings NS q

Data ONTAP 7-Mode Administration Course D7ADM; 5 Days, Instructor-led

NS0-158 netapp. Number: NS0-158 Passing Score: 800 Time Limit: 120 min.

Cluster Switch Setup Guide for Cisco Switches. May _A0_UR006

FlexArray Virtualization

Introduction to NetApp E-Series E2800

Clustered Data ONTAP 8.3 Administration and Data Protection Workshop

Clustered Data ONTAP Administration and Data Protection

64-Bit Aggregates. Overview and Best Practices. Abstract. Data Classification. Technical Report. GV Govindasamy, NetApp April 2015 TR-3978

FlexArray Virtualization Implementation Guide for Third- Party Storage

RapidData Migration Solution

VMWARE VREALIZE OPERATIONS MANAGEMENT PACK FOR. NetApp Storage. User Guide

BraindumpsVCE. Best vce braindumps-exam vce pdf free download

Copy-Free Transition Guide

Data ONTAP 8.1 High Availability and MetroCluster Configuration Guide For 7-Mode

MetroCluster Service and Expansion Guide

Data ONTAP 7.3 Documentation Roadmap

Installation and Cabling Guide

Virtual Storage Console, VASA Provider, and Storage Replication Adapter for VMware vsphere

FlexPod Express with Microsoft Windows Server 2012 R2 Hyper-V: Small and Medium Configurations

MAX Data 1.1 Installation and Setup Guide. November _A0

DumpExam. The best exam dump, valid dumps PDF, accurate exam materials provider

PASS4TEST IT 인증시험덤프전문사이트

Hitachi HH Hitachi Data Systems Implementer File(R) Services-NAS.

Hitachi HQT Hitachi Data Systems Certified Professional - NAS installation HAT.

Data ONTAP 8.2. Upgrade and Revert/Downgrade Guide For 7-Mode. Updated for NetApp, Inc. 495 East Java Drive Sunnyvale, CA U.S.

NAS for Server Virtualization Dennis Chapman Senior Technical Director NetApp

Data ONTAP 7-Mode Administration

Installation and Cluster Deployment Guide for VMware

Vmware 3V VMware Certified Advanced Professional Data Center Virtualization Design.

Installation and Cluster Deployment Guide for KVM

NetworkAppliance NS Network Application FAS900 Pre-Sales Engineer. Download Full Version :

FlexPod Express with VMware vsphere 6.7U1 and NetApp AFF A220 with Direct- Attached IP-Based Storage

Data Ontap 7.3 Command Manual Page Reference Volume 2

VMware Horizon View 5.2 on NetApp Clustered Data ONTAP at $35/Desktop

PASS4TEST IT 인증시험덤프전문사이트

Dell EMC NX3340 and NX3240 Network Attached Storage System using Windows Storage Server Troubleshooting Guide

Transcription:

ITdumpsFree http://www.itdumpsfree.com Get free valid exam dumps and pass your exam test with confidence

Exam : NS0-180 Title : NetApp Certified Storage Installation Engineer, Clustered Data ONTAP Vendor : Network Appliance Version : DEMO Get Latest & Valid NS0-180 Exam's Question and Answers 1 from Itdumpsfree.com. 1

NO.1 Advanced Drive Partitioning (ADP) is available for which three NetApp systems? (Choose three.) A. FAS80XX with SAS and SATA disks B. FAS25XX with SSD disks C. FAS80XX with SATA disks D. FAS25XX with SATA disks E. FAS80XX with SSD disks Answer: B,D,E ADP supported platforms: B, D: 2200, 2500 (Internal drives): Root Data Slice (HDD), Root Data Slice (AFF - All Flash FAS) E: 3200, 6200, 8000 ( 48 drives) : Root Data Slice (AFF - All Flash FAS) Example ADP configuration: FAS8040 All-Flash (36 x 800GB SSD) Reference: NETAPP DATAONTAP 8.3 ADP ROOT DISK-SLICE DEEP-DIVE http://www.datacenterdan.com/blog/netapp-dataontap-83-adp-root-disk-slice-deep-dive NO.2 Click the Exhibit button. You are asked to install a new cluster with six FAS8060 nodes. While running Config Advisor, you see the messages shown in the exhibit. The customer does not want ACP cabled on their cluster. Which two actions would allow the installation to be completed successfully? (Choose two.) A. Advise NGS that the customer has a controller in an unsupported state. B. Advise the customer that they must acknowledge that they are not using ACP on the installation. C. Advise the sales team that the customer is operating without ACP and that the customer is asking you to leave it that way. D. Advise the customer that the error will cause the controller to not operate properly and create an unsupported state. Answer: B,C After you cable the SAS connections, you have the option to cable the Alternative Control Path (ACP) connections. You should use the ACP protocol because it enables Data ONTAP to manage and control the SAS disk shelf storage subsystem NO.3 A customer learns that a certain NetApp tool allows remote data collection, intelligent core file handling, and notification of down storage controllers for technical support analysis and troubleshooting. Get Latest & Valid NS0-180 Exam's Question and Answers 2 from Itdumpsfree.com. 2

What is the name of this tool? A. RSA B. HWU C. Synergy D. HW Assist Answer: A Remote Support Agent (RSA) is a remote diagnostics data collector that is embedded directly into the storage controller's remote management device firmware. Remote Support Agent enables a NetApp support engineer to remotely request an automated upload of log files, core files, and other diagnostic information stored in the storage controller and to remotely trigger an on-demand AutoSupport collection. Incorrect: Not B: The Hardware Universe (HWU) application is NetApp's system configuration solution. Not C: NetApp Synergy is a complete design, deployment and documentation tool. The program enables you to build a very accurate, detailed model of a NetApp storage system. You can represent most aspects of a storage deployment including the hardware configuration and the sizing of all storage containers, including aggregates, volumes, qtrees and LUNs. Reference: Clustered Data ONTAP 8.2, Remote Support Agent Configuration Guide, Page 5 NO.4 What are two supported cluster interconnect switches for the FAS8040 nodes? (Choose two.) A. Cisco Catalyst 2960 B. Cisco NX5596 C. NetApp CN1610 D. NetApp CN1601 Answer: B,C Cisco NX5596 is a cluster interconnect switch. NetApp CN1610 is a cluster interconnect switch that can be used for FAS8040 nodes. Incorrect: Not A: The Cisco Catalyst 2960 is not a cluster interconnect switch. Not D: NetApp CN1601 is a cluster management switch. Reference: Clustered Data ONTAP 8.3, Express Setup Guide for 80xx Systems NO.5 You want to create a data volume on aggr0 and you receive a message with the following warning: ''Warning: You are about to create a volume on a root aggregate. This may cause severe performance or stability problems and therefore is not recommended. Do you want to proceed?'' What is the reason for this severe performance or stability problem? A. Controller failover and storage failover are separate processes that must occur in parallel, otherwise problems will arise. B. The performance load generated by the data volume can be very strong, so it should not be shared with vol0 on aggr0, requiring a separate aggregate for it. Get Latest & Valid NS0-180 Exam's Question and Answers 3 from Itdumpsfree.com. 3

C. The performance load generated by the vol0 cannot be shared with any other volume on aggr0, requiring a dedicated aggregate for it. D. Controller failover and storage failover are separate processes that must occur at different times, otherwise problems will arise. Answer: B One possibly cause is Disk I/O contention on the data volume. The root volume in Cluster-Mode is used to store and update various tables of the replicated database. Crucial information regarding the locations of LIFs, volumes, aggregates, and different jobs required to run in the cluster are stored in these tables. If a root aggregate has very busy data volumes, the disks in the aggregate will experience higher latency. When a node is unable to update its copy of the replicated database fast enough, it will consider itself unhealthy and stop serving all the data until it can catch up. This is extremely disruptive and affects all the volumes on the node, even if the cause is related to the data volumes stored on the root aggregate only. Reference: Why is a warning displayed when attempting to create one or more data volumes in the root aggregate in Data ONTAP Cluster-Mode? https://kb.netapp.com/support/index?id=3013563&page=content&locale=en_us NO.6 Which two statements are true regarding SSDs? (Choose two.) A. SSDs are only available in 400 GB sizes. B. SSDs must be in different RAID groups than HDDs. C. SSDs are available for multi-disk carrier shelves. D. The Maintenance Center is not available for SSDs. Answer: B,D Incorrect: Not A: There are, for example, 100 GB, 200 GB, and 800 GB SSD sizes. Not C: Disks in multidisk carriers always have the Data ONTAP disk type of MSATA. Get Latest & Valid NS0-180 Exam's Question and Answers 4 from Itdumpsfree.com. 4