B. AVM321S/AVM322S: 1000N Actuator with analog SUT positioner

Overview of types. Technical data

Electric Actuators Type 5824 (without fail-safe action) Type 5825 (with fail-safe action)

Power consumption In operation At rest For wire sizing

9.5 nominal torque 4.5 W 16 VA. Min. 30 nominal voltage Min. 30 Nm. Reversible with switch By mounting. MIN (minimum position)

Preliminary ILEA A/B SERIES IOM. ILEA A/B Series electric actuators ILEA-Axx ILEA-Bxx TABLE OF CONTENTS. ILEA-A/B_IOM_NoRev_ No Rev

Functional data Nominal torque min. 180 in lb [20 NM] Communicative control Cloud: (call for clientapi )

MBM - Modular I/O system IP20

SRQ24A. Technical data. Safety notes. Rotary actuator for ball valves Torque 16Nm Nominal voltage AC/DC 24V Control: Open-close Running time 9s

Powermite 599 MT Series SAS Electronic Valve Actuator 24 Vac or 24 Vdc, Proportional Control

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Operating and installation instructions

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Contact protection relay

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electrical actuator AME 855

See «Overview of types» 90 s / 60 mm 150 s / 100 mm Manuelle Auslösung der Adaption durch Drücken der Taste «Adaption» oder mit dem PC-Tool

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Functional data Factory settings Variable Setting Torque Inhibiting torque

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

IQM & IQML RANGE CONTROL AND MONITORING FACILITIES. Publication E420E issue 7/02

Inductive sensor Dual sensors with extended temperature range NI4-DSU35TC-2Y1X2/S97

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency. Draft

Magforce STD/STG/STW/SKD/SKS/STN

Inductive sensor For rotary actuators NI4-DSU35TC-2Y1X2

Electric Actuators with Process Controllers

GEMÜ 9468 Motorized quarter turn actuator

Functional data Communicative control Cloud: (call for clientapi ) Angle of rotation 90

ML7421A,B Electric Linear Valve Actuators

Functional data Communicative control Cloud: (call for clientapi ) Angle of rotation 90

MVE5xxR. Globe Valves Actuators with Emergency Fail Safe Function DESCRIPTION POWER SUPPLY [N] APPLICATION AND USE OPERATION

Technical data sheet. Technical data

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

MME/MOE Intelligent Electric Actuators About Ontrac

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Inductive sensor NI3-EG08K-Y1-H1341

Data Sheet T 6493 EN. TROVIS 6400 Automation System TROVIS 6493 Compact Controller. For panel mounting (front frame 48 x 96 mm/1.89 x 3.

Power consumption In operation At rest For wire sizing. Torque Inhibiting torque. 150 s / C Sound power level Motor

02/11/2015

Technical data sheets

Digital Output Module 4-Channel Version for Zone 1 Series 9475/

Digital Output Module 8-Channel Version for Zone 1 Series 9475/

Inductive dual sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933

Limit switches Instrument sensors

Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG R0011

Technote. Frese OPTIMA Compact actuators DN10-DN32. Application. Features thermic actuators. Features motoric actuators. Approval.

Electrical Rotary Drive

Functional data Position indication reflective visual indicator (snap on) Communicative control Cloud: (call for clientapi )

Inductive sensor BI5-EM18-Y1X-H1141

PGR-3200 MANUAL INSULATION MONITOR

Electromotive actuators for combi valves

Magnetic Field Sensor Magnetic-inductive Proximity Sensor BIM-EG08-Y1X

TA-MC Actuators. Actuators High performance proportional actuators

Digital Output Module 8-Channel Version for Zone 2 Series 9475/

Inductive sensor BI1.5-EG08-Y1-H1341

Standard Options. Model 4100 Position Indicating Meter. Three Phase Motor Control. Positran Transmitter

Inductive sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933

AS-Interface I/O Module

Products no longer available

Speed Controller ZSU A01

Digital Output Module 8-Channel Version for Zone 2 Series 9475/

Inductive sensor with analog output BI15-M30-LI-EXI

1.5 Solid State Relays

Thermistor motor protection relays CM-MSS.12 and CM-MSS.13

InReg Volume flow controller Pa

Relay actuators & Status indicating modules

DMA Actuator drives for - Motorised Butterfly Valve DMK - Motorised throttle DML

DMA Actuator drives for - Motorised Butterfly Valve DMK - Motorised throttle DML

Open/close controller for AC drives UMS 5 UMS U5 UMS 5P

Switching and controlling in the switch cabinet

Digital Positioner 8049

ACExC 01.2 Modbus TCP/IP

EE360. High-End Moisture in Oil Transmitter. Typical applications. Features EE360 EE360. (+34)

ACOPOSinverter P74. User's Manual. Version: 2.20 (August 2016) Model no.: Original instruction

Magnetic field sensor Magnetic-inductive Proximity Sensor BIM-M12E-Y1X

NKQB24-1, NKQX24-1 On/Off, Fail-Safe, Operation, Direct Coupled, 24V

Power consumption In operation At rest For wire sizing. Torque Inhibiting torque. 150 s / C Sound power level Motor

PSR-SCP- 24DC/SDC4/2X1/B PSR-SPP- 24DC/SDC4/2X1/B

AV24-MFT AV24-MFT2 AV24-MFT2-C105. Power consumption In operation For wire sizing N 1700 N Control Control signal Y Operating range

MSR178DP. Description. Features. Specifications

Control unit SG-EFS 104/2W. EN Operating instructions. Innovative by tradition. Version SG-EFS 104/2W 24 V=/~

Operating Instructions. Intrinsically Safe Isolation Relay for Switches Model: REL manual_rel-6_0505

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Products no longer available

Digital Output Module 4-Channel Version for Zone 1 Series 9475/

Operating Instructions

Inductive sensor For rotary actuators NI4-DSU35-2Y1X2-H1140

Miniature Circuit-Breaker IEC Series 8562

Inductive sensor BI1.5-EG08-Y1-H1341

Available with actuator function: POWER OPEN - POWER CLOSE FAILSAFE MODULATING FAILSAFE MODULATING. Overview

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Magnetic Field Sensor for pneumatic cylinders BIM-INT-Y1X-H1141

More than safety. Joystick Switches

Polymer Electric. Operating Instructions. Control Unit SG-RST 153. Version 0.3

Use. Functions. OpenAir TM. Linear version, modulating, AC 24 V

Transcription:

ARI-PREMIO Plus 2G Electric thrust actuator with fail-safe function Electric thrust actuator with fail-safe function ARI-PREMIO Plus 2G Electric thrust actuator with fail-safe function ARI-PREMIO Plus 2G 9 kn Features 2 torque switches Max. permissible ambient temperature 0 C to +50 C (32 F to +122 F) (other temperatures on request) Enclosure IP 65 Additional devices available Travel indicator Inductive switch for detecting the triggered fail-safe function Automatic clamping of the spring unit to restore the fail-safe function Edition 01/15 - Data subject to alteration - Regularly updated data on www.ari-armaturen.com! Data sheet 000034 englisch (english)

ARI-PREMIO Plus 2G 9 kn Electric thrust actuator with fail-safe function Working principle The fail-safe unit, which is located between the actuator and the valve, consists of four gas springs that are held over a toggle mechanism and an electro-adhesive magnet during normal operation. The fail-safe unit works in normal operation without any moving parts and virtually no wear. In control mode the actuator closes up the valve with 15kN thrust force. Putting into operation / Voltage return When connecting the power supply, the fail-safe unit is tensioned over the built-in electronics unit. Since the actuator during the clamping process does not follow the control signal, the fail-safe controller provides a signal for the clamping process for the parent control (refer to wiring diagram output Prelo ). After the fail-safe unit is cocked, the actuator goes to the normal operation. The scope of operation of the actuator and the electronics respectively are available with all the variables. Further informations about the individual functions refer to quick guide or operating and installation instructions. Power failure / mains interruptions of the fail-safe controller Upon interruption of power supply for the fail-safe controller triggers the electro-adhesive magnet and the fail-safe unit moves the driving spindle. Depending on the travel and the temperature achieved the fail-safe unit 9 kn closing force (refer to table at Technical Data ). 2 Edition 01/15 - Data subject to alteration - Regularly updated data on www.ari-armaturen.com!

ARI-PREMIO Plus 2G 9 kn Technical data Technical data Type ARI-PREMIO Plus 2G 9 kn Thrust force / Closing force kn 9 kn (at 50 mm) Closing direction extending Travel distance max. mm 50 mm Duty classification acc. to EN 60034-1 Control speed mm/s S3-80% ED / max. 1200 c/h (at +70 C) 0,20 / 0,31 / 0,38 / 0,79 adjustable Fail-safe speed mm/s 100 mm/s Supply voltage V 24 V AC/DC Motor type BLDC (Brushless DC motor) Power consumption VA max. 65 (depends on the operating speed) Torque switch 2 pcs. included internally Enclosure EN 60529 IP 65 Max. storage temperature C -20 C... +80 C Max. permissible ambient temperature Hand operating device Operation Max. cable cross section Mounting position Characteristics at control signal failure Gear lubricant C 0 C... +50 C other temperatures on request (For outdoor use and sub-zero temperatures, a heating is recommended!) Yes (engageable) optional: 3-point: 12 V DC/AC to 250 V DC/AC 0 to 10 V DC: load resistance 500 kohm resolution 12 Bit 4 to 20 ma DC: load resistance 125 Ohm resolution 12 Bit Supply voltage: 2,5 mm² 3-step input: 2,5 mm² Input signals: 2,5 mm² Any, except: motor not hanging downwards The actuator must be supported at horizontal orientation! adjustable with slide switch: OPEN, STOP, CLOSE Molyduval Valenzia H2 Weight kg 27 kg Aditional voltage refer to page 4 Accessories refer to page 4-5 Edition 01/15 - Data subject to alteration - Regularly updated data on www.ari-armaturen.com! 3

Additional voltage Switching power supply for ARI-PREMIO Plus 2G 9 kn Voltage V - Hz 90-264 V AC 47-63 Hz 127-370 V DC Power consumption VA max. 65 Accessories Type Binary feedback Electronic position indicator Heating ARI-PREMIO Plus 2G 9 kn Type Relay board Type Analog output card Heating resistor 2 intermediate positions, - to set by switch, - changeover contacts 250 V, 3 A ohm resistive load, 6 A inductive load 1 failure signal and 1 warning signal, - changeover contacts 30 V AC/DC, 2A analogue output for position feedback, 4-20 ma switchable to 0-10V invertable galvanic isolation between the mains voltage and feedback signal active 230 V AC, 115 V AC, 24 V AC/DC; 15 W automatic switching circuit 4 Edition 01/15 - Data subject to alteration - Regularly updated data on www.ari-armaturen.com!

ARI-PREMIO Plus 2G 9 kn Accessories Relay board Relais (potential-free changeover contact) Operating voltage U B max. 1 (open) 1 (close) 3 warning 4 failure 250 V, 3 A ohm resistive load, 6 A inductive load 30 V AC/DC, 2A max. cable cross section 2,5 mm² 1,5 mm² Contact material Storage temperature -40 C... +85 C -40 C... +85 C Operating temperature (Note temperature range for the entire actuator!) Features: Setting of the switching points over push buttons zero-potential changeover contacts 2 intermediate positions or end positions 1 Collective failure message at: - Control signal failure - Position can not be reached (Motor-/gear failure) - Blocking (actual) - Actuator is not intialised - Voltage failure 1 Collective warning message at: - Hand operating device - Blockage (identified) - Position can not be reached - Maintenance - Internal temperature exceeded - ED management active - Silent running - to small travel during initialization Gold Analog output card Output control signal Y U Measuring resistance (load resistance) 0-10 V DC Signal resolution Output control signal Y I Measuring resistance (load resistance) 4-20 ma DC, active Signal resolution Features: for position transmitter max. 2 kohm 12 Bit max. 500 Ohm 12 Bit Edition 01/15 - Data subject to alteration - Regularly updated data on www.ari-armaturen.com! 5

Thermal characteristic: Gas springs of the fail-safe unit ARI-PREMIO Plus 2G 9 kn Thermal characteristic / Fail-safe force depending on the travel 16000 14000 12000 Thrust force (N) 10000 8000 6000 4000 2000 thrust force extended at 50 mm nominal travel necessary force for clamping max. operating force of the actuator 0 0 C 10 C 20 C 30 C 40 C 50 C Temperature ( C) Fail-safe force depending on the travel (at 0 C) 14000 12000 10000 Thrust force (N) 8000 6000 4000 2000 0 0 10 20 30 40 50 Travel (mm) 6 Edition 01/15 - Data subject to alteration - Regularly updated data on www.ari-armaturen.com!

Wiring diagram: ARI-PREMIO Plus 2G 9 kn ARI-PREMIO Plus 2G 9 kn Wiring diagram ARI-PREMIO Plus 2G standard Accessories Sensor Input Preloading Output signal 24VDC Option ARI-PREMIO Plus 2G 24V AC/DC analog red blue HZ Heating resistor Relay Relay board Y out Analog output card Edition 01/15 - Data subject to alteration - Regularly updated data on www.ari-armaturen.com! 7

ARI-PREMIO Plus 2G 9 kn Dimensions 9 kn with fail-safe function Nominal travel 50 mm 9 kn A (mm) 210 B (mm) 184 C (mm) 90 Ø D1 (mm) 130 X (mm) 200 H (mm) 1029 h (Nominal travel) (mm) 50 L (Column) (mm) 641 Technology for the Future. G E R M A N Q U A L I T Y V A L V E S ARI-Armaturen Albert Richter GmbH & Co. KG, D-33756 Schloß Holte-Stukenbrock, Tel. +49 52 07 / 994-0, Telefax +49 52 07 / 994-158 or 159 Internet: http://www.ari-armaturen.com E-mail: info.vertrieb@ari-armaturen.com 8 Edition 01/15 - Data subject to alteration - Regularly updated data on www.ari-armaturen.com!