INSTALLATION PROCEDURE FOR THE INNOVEC IPT POWERED PRINTING TOTALISOR

Similar documents
Panel Indicators. NEW 4~20mA Panel Display. Process Indicators INTECH INSTRUMENTS.

USER INSTRUCTION MANUAL FOR LOADCELL TRANSMITTER MODEL TDC/I/0550 (SOFTWARE: VER2A) INDEX

GFC114. Low Power Flow Computer FEATURES

GFC111-MB. Flow Computer With RS485 MODBUS FEATURES 1. DESCRIPTION APPLICATIONS

NETRONICS HS3500 CONTROLLER

ph Meter & Controller Model: NANO-PCD1

MODEL 715AN QUADRATURE DEGREES COUNTER

Xi4 Quick Reference Guide

NF770 Temperature Compensation Liquid Flow Computer

Vorne Industries. 87/415 Rate Monitor Display User's Manual Industrial Drive Itasca, IL (630) Telefax (630)

OPERATING MANUAL FOR SMIT-301MH STREAM SELECTOR

OPERATING MANUAL FOR STREAM SELECTOR

Digital Torque Screwdriver Model STC2-G

12-36 VDC/12-24 VAC Power Option 4-Digit Display, 0.56 (14.2 mm) or 1.20 (30.5 mm)

NF760 Batch Controller

Vorne Industries. Model 77/232 Serial Input Numeric 3" Display User's Manual

MONARCH 9416 XL QUICK REFERENCE

Vorne Industries. 2000S Series Serial Input Alphanumeric Display User's Manual

Introduction Page 1. Power Supply Requirements & Hardware Options Page 2. External Connectors (Functions & Pinouts) Page 2

S-14 S-14. Compact Digital Multimeter. Compact Digital Multimeter

OPERATING INSTRUCTION

RS3000 SERIES BILL ACCEPTORS

Able Systems Limited Northwich, Cheshire, England

Environdata FA ma Converter Guide

DM-918 OPERATIONS MANUAL AUTORANGING MULTIMETER

Trident and Trident X2 Digital Process and Temperature Panel Meter

EPSON P R O D U C T I N F O R M A T I O N G U I D E 2/02

Y800 Plus Frequency, Rate & Period Meter With dual, independently field-scalable channels

E102 - Advanced Strain Gauge Transducer Display Interface. Contents

Stellar Instruments. SC1 Controller & Display System. General User s Manual. Copyright 2013 Stellar Instruments 1

TRACKER 240 SERIES. Load Cell and Weighing Indicators. A Precision Measurement Instrument with Outstanding Features

ME6008M Batch Monitor Printer Driver Unit

Two Door Controller GEN-045

INTRINSICALLY SAFE DUPLEXER PROTECTION. ELECTRONICS, INC Vulcan Road Apopka, Florida MOTOR INSTRUCTION MANUAL

DOT MATRIX PRINTER SP6000 SERIES

Intrinsically safe batch controller Batching Master 110i

Autoranging True RMS Multimeter User Manual

Quick Installation Guide Direct and Transfer Thermal Printer

USERS' GUIDE. to the. ABLE SYSTEMS Ap25-24S, Ap25-32S & Ap25-40S. Panel Mounting Printers

LCI User Manual mantracourt.com

ELECTRONIC DISPLAYS INC. 135 S. CHURCH STREET ADDISON, ILL

Installing Sentor. Hardware Installation

7SR242 Duobias Multi-Function 2-Winding Transformer Protection Relay

2 Table of Contents 1. TABLE OF CONTENTS. 1. Table of Contents Introduction Wiring Diagram Terminals Review...

LAUREL. Laureate Dual-Channel Pulse Input Totalizer With Two Independently Scalable Input Channels & Presets ELECTRONICS, INC. Features.

AD-8923-BCD. Remote Controller (BCD) INSTRUCTION MANUAL 1WMPD

FLÄKTGROUP OFFERS A WIDE RANGE OF PER- MANENT MAGNET MOTORS (PM) AND FREQUENCY CONVERTERS FOR PLUG FANS. POWER RANGE IS FROM 0,8 KW TO 15 KW.

PC2004 PRESSURE CONTROLLER

High Voltage DC Meter

D7000 SERIES MODBUS TCP/IP ETHERNET INTERFACE MODULES

ES-362U PRESETTABLE MASTER TIMER

genesis TECHNICAL MANUAL Two-Door Controller GEN-045

Installation & Operation

2 in 1 LAN Tester and Multimeter Model:

LAUREL ELECTRONICS, INC.

Contents. Temperature & Process Measurement Indicators Setup Guide

DT1 Series 2.1 SINGLE CHANNEL TALKING DIALLER # N761. INSTALLATION MANUAL 3 rd EDITION.

SP2200. Installation Manual. Ticket Printer. Software Version 1.3

OPERATING MANUAL K. C. Kew Electronics Athletics Timing Processor ATP-201D

PIX-55. Atomic Time Clock. Operation Manual

Digital Keypad Introduction

CDN503 HIGH DENSITY I/O ADAPTER USER GUIDE

POWER SERIES Plus Watt-VAR / Watt-Power Factor Digital Switchboard Meter User s Manual IM2492WVPF-1

Programming and Installation Manual

One station Impact Printer. Model: WP-300 Version : 1.03

TC Type Range Conformity Error. J -210 C to +760 C (-347 F to F) ±0.09 C (±0.16 F) K -244 C to C (-408 F to F) ±0.1 C (±0.

Digital Frequency Divider INSTRUCTION MANUAL CONTENTS. 1. Working Principle Installation Setting Up Technical Data 4.

Matrix printer uni-bit. Application areas

USER GUIDE. to the CP130. Thermal Printer

180 Series Keypad. Handbook. Revision 2.1

Mounting the Model 2601

DUAL COLOUR DISPLAY DC PROCESS INDICATOR. Product Manual

LAUREL. Laureate Digital Panel Meter for Process and Ratiometric Signals ELECTRONICS, INC. Features. Description

Vorne Industries. 87/708 Master Clock Display User's Manual

SHPFI Smart Frequency to Current Converter & Pulse Scaler Installation and Operating Instructions

FG-7000 Digital Force Gauge Operation Manual

Model DT-315P DIGITAL STROBOSCOPE INSTRUCTION MANUAL

1/32-DIN TEMPERATURE CONTROLLER INSTALLATION, WIRING AND OPERATION MANUAL FORM 3882

MODEL SW6000 & SM6100 CENELEC INSTRUCTIONS

Installation & Operation Guide

The IQ240 panel mount load cell indicator is a precision digital indicator for load cell and strain gauge applications.

THERMAL PRINTER SPEC BAS Basic Features. 1.) Type : PANEL Mounting or DESK top type. 2.) Printing Type : THERMAL PRINT

DIGITAL TORQUE METER MODEL TME2

POWER Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

UDC 1000 and UDC 1500 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS

Veeder-Root brand Series C628 Rate Meter (C628-4XXX)

INSTRUCTIONS FOR MODEL 1000 DIGITAL PROCESS INDICATOR AND ALARM

HIGH-VOLTAGE DC METER

MODEL : AP-8220 U Receipt Printer User s Manual

OPERATING MANUAL AND TECHNICAL REFERENCE

FEMA ELECTRÓNICA. Series MAG983-X. COUNTERS for IMPULSE signals MAG983-1 MAG983-2 MAG983-3 MAG USER S MANUAL (HT0695-r050705)

DTY-EPS DTY-EPU. w e DTY-EPP- - w e. t y. q DTY-EPU PSU-BR DTY-EPP-CC- L DTY-EPS. ZD1 ZD4 Tr1 Tr4

BT BATTERY TOTALISER. Universal Mount Series I N S T R U C T I O N M A N U A L

CDN502 HIGH DENSITY I/O ADAPTER USER GUIDE

5000 Series Audio Matrix

NFC110. Flow Computer For Low Pulses FEATURES

Manual. Water Vend Controller Model ESDI WARNING! ELECTRICAL SHOCK HAZARD! AUTHORIZED PERSONNEL ONLY. EXPOSED 120 VAC ON CIRCUIT BOARD

TTP-244 / TTP-244 Plus THERMAL TRANSFER / DIRECT THERMAL BAR CODE PRINTER USER S MANUAL

User s Guide. LDB-RTU Meters for Modbus RTU. Shop online at omega.com. For latest product manuals:

Instruction Manual. AlfaSPID Controller - ROT

Transcription:

INSTALLATION PROCEDURE FOR THE INNOVEC IPT POWERED PRINTING TOTALISOR Suite 5, 56-6 Chandos Street, St. Leonards NSW 065/PO Box 35 Spit Junction NSW 088 Australia Phone +6 9906 758 www.innovec.com page

IPT POWERED TOTALISOR CALIBRATION PROCEDURE Thank you for purchasing an Innovec product. The IPT totalises flow in increments of one litre and 0. litres, displays the total on an 6 digit 0mm alphanumeric LCD backlit display and prints out the batch total, master total, time, date, client name (header one), Job name (header two) on a 40 column dot matrix printer set for double height printing which is incorporated into the instrument. It is housed in a panel mounting enclosure measuring 44mm wide x 44mm high x 45mm deep. The count values are stored in non-volatile EEPROM memory for a minimum period of 0 years. The instrument incorporates two counters, an 8 Digit foreground (batch total), which is normally displayed and a background total (master total). The K factor is a number of eight characters [00.000000]. Run Mode Functions: Up button displays the current time Down button displays the current date Mode button displays the current master total Step - Panel Installation The instrument is supplied in 44mm x 44mm x 45mm deep aluminium enclosure with sealed weatherproof front and is designed to be panel mount mounted with a panel cut out of 38mm high by 38mm wide. To mount, the instrument should be slid into the hole from the front and the 4 brackets fixed to the side and tightened to hold the instrument firmly in place. Step - Electrical Connection The instrument has been supplied with a two-part screw terminal (male and female) for easier installation which has a ten (0) way plug for signal and a ten (0) way plug for power and output relay connection. The instrument is supplied as either an AC or DC powered instrument. As an AC powered instrument it has a universal input primary which can be connected to 85 to 65VAC 50Hz to 60 hertz single phase supply. As a DC powered instrument it has a 30watt DC to DC convertor which provides 500VDC isolation from input to output. Before connecting power to the instrument always check the label for the supply the instrument has been configured for: For a nominal 40VAC operation connect AC power to: (a)terminal 8 is 40VAC supply (b)terminal 9 is neutral supply (c) Terminal 0 is ground supply For a nominal 5VAC operation connect AC power to: (a)terminal 8 is 5VAC supply (b)terminal 9 is neutral supply (c) Terminal 0 is ground supply For a nominal 4VDC (8-36VDC) operation, connect DC power to: (a)terminal 8 is 4VDCsupply (b)terminal 9 is 0VDC supply (c) Terminal 0 is ground supply Suite 5, 56-6 Chandos Street, St. Leonards NSW 065/PO Box 35 Spit Junction NSW 088 Australia Phone +6 9906 758 www.innovec.com page

Step Input Connection Input Signal used Input Connection Switch settings used for this function CHI + - 3 4 5 6 7 8 CMOS Logic signal 3 off off off off on off off off Open Collector or Reed switch 3 off off off off on off on off Namur Proximity (set loop supply out to 8 volts) 8 3 off off on on on off off off Switch or Reed Switch with debounce circuit (00Hz max) 3 off off off off on off on on Coil (0mv P-P minimum) 3 off on off off off off off off Coil (low impedance mv pp minimum) 3 on on off off off off off off CMOS Logic signal for vortex or magnetic flow meters Open Collector or Reed switch hall effect sensors or positive displacement flow meters with reed switch output Namur Proximity - positive displacement flow meters with wire proximity output not yet available Coil (0mv P-P minimum) millivolts signal from turbine meter Step 3 - Reset Button Connection The instrument accepts a reset from a clean contact (contact closure). The fore ground total can be reset by a normally open push button connected across terminal seven (7) reset input and terminal () internal 0VDC. Holding this switch closed for a minimum of 5 seconds will also reset the background total. Step 4 - Using the 4VDC loop supply The 4VDC loop supply is available on terminal eight (8) but is limited to a current capacity of approximately 5mA. It is not available in this application. Note: for the Namur sensor this loop supply needs to be adjustable to 8 volts coming soon Step 5 - Using the Printer The printer detects the paper running out, and the displays the message paper out Please refer to appendix for information regarding care of the printer including, changing of paper rolls and the print ribbon. Step 6 - Instrument Calibration All functions of the instrument are programmable from the four touch buttons mounted on the circuit board. Mode Prog/Run Print To enter the programming mode press: The display shows: Prog/Run Suite 5, 56-6 Chandos Street, St. Leonards NSW 065/PO Box 35 Spit Junction NSW 088 Australia Phone +6 9906 758 www.innovec.com page 3

SET UP It is necessary to push in sequence: UP BUTTON then DOWN BUTTON then UP BUTTON again. (This is a simple ACCESS code) You are now in the programming mode. The instrument displays: DP This is the decimal point position. The decimal point can be adjusted for NO decimal (00) point for the display of units of measure or a decimal point (0.0) for the display or 0. measurement units. Pushing the up button will cause the number to increment. If the up button is being pushed the DP increments. If no changes are required or when you have selected the required display decimal point position, please press: To show: Mode KFACTOR This is the K-factor that the instrument uses to calculate the flow in litres. This is displayed for approximately 3 seconds before displaying the actual K factor value. As you have entered K Factor programming point you will notice the right most digit is flashing. The flashing digit designates that this is the digit that can be changed. Pressing the up button will cause this digit to increment from 0 to 9 and back to 0. Pressing the down button ( ) will cause (the controllable digit to move one decimal place to the left) the second most digit from the right to flash and the right most digit is now stationary. To enter the K factor it is first necessary to calculate this value. Divide (for one litre) by the calibration factor of your flow sensor. If your flow sensor has a factor of 7, then divide by 7 = 0.4867. This is the factor you should enter. Enter the value This can be changed using the up or down button. Pressing the up button causes the flashing digit (right most digit [digit ] (the right hand digit when viewed from the front) to increment. If the up button is kept pressed after digit has incremented to 9 then 0 and continuously to 9. Pressing the down button causes the digit being changed to increment left. If you were changing digit zero (0) [the right most digit] by pressing the down button once you will now be on digit one [the second digit from the right], and so on. If no changes are required, or when you have selected the required K-factor, please press. Mode To show TIME Suite 5, 56-6 Chandos Street, St. Leonards NSW 065/PO Box 35 Spit Junction NSW 088 Australia Phone +6 9906 758 www.innovec.com page 4

This is the current time that the instrument uses when printing a total value. This is displayed for approximately 3 seconds before displaying the actual time value in 4hour format. 0:00 The time can be changed using the up button. As you have entered time programming point you will notice the right most digit is flashing. The flashing digit designates that this is the digit that can be changed. Pressing the up button will cause this digit to increment from 0 to 9 and back to 0. Pressing the down button ( ) will cause (the controllable digit to move one decimal place to the left) the second most digit from the right to flash and the right most digit is now stationary. Pressing the down button causes the digit being changed to increment left. If you were changing digit zero (0) [the right most digit] by pressing the down button once you will now be on digit one [the second digit from the right], and so on. If no changes are required, or when you have selected the required time value, please press. Mode To show Date This is the current date that the instrument uses when printing a total value. The date is in European format [days/month/years]. This value is displayed for approximately 3 seconds before displaying the actual date value. 3 0 008 The date can be changed using the up button. As you have entered date programming point you will notice the right most digit is flashing. The flashing digit designates that this is the digit that can be changed. Pressing the up button will cause this digit to increment from 0 to 9 and back to 0. Pressing the down button ( ) will cause (the controllable digit to move one decimal place to the left) the second most digit from the right to flash and the right most digit is now stationary. Pressing the down button causes the digit being changed to increment left. If you were changing digit zero (0) [the right most digit] by pressing the down button once you will now be on digit one [the second digit from the right], and so on. If no changes are required, or when you have selected the required time value, please press. To show MODE TEXT 0 N This is the first character of the first line of header text of 4 characters wide that the instrument uses when printing. Note: The instrument has the ability to print a two lines of header on the users printing ticket. This text is programmable by the user as: Suite 5, 56-6 Chandos Street, St. Leonards NSW 065/PO Box 35 Spit Junction NSW 088 Australia Phone +6 9906 758 www.innovec.com page 5

A first line of 4 characters [marked text 0 to text 4] meant for the Clients name. A second line of 6 characters [marked text 5 to text 40] meant for the clients job or application name. The Units of measurement name is also programmable and has been allocated eight (8) characters and is found at location Text 4 to 48 [a blank space is one character]. Print sample Innovec Controls Pty Ltd Truck No 3 Date 3-0-08 Time 7:56 hrs Batch Total 00000963.5 Litres Master Total 00000963 Litres The text value can be changed using the up or down button. Pressing the up button causes digit (the right hand digit when viewed from the front) to increment. If the up button is kept pressed after digit has incremented to 9 it will continue through the alphabet from letter A to letter Z. If the up button is released at any time and pressed again incrementing will restart. Pressing the down button causes digit (the right hand digit when viewed from the front) to decrement. If the down button is kept pressed after digit has decremented to 0 it will jump to the last letter of the alphabet Z and decrement down to letter A. If no changes are required, or when you have selected the required character, please press. To show MODE TEXT 0 N This is the second character of the first line of header text. Pressing the MODE button will continue up to text 4 to complete the first line of text that the instrument uses when printing. Continuing to press the MODE button will take you through the second header (test 5 to text 40). Still continuing to press the MODE button will take you through the units of measurement header (test 4 to text 48). After displaying text 48 the instrument will cycle back to the beginning To show MODE DP And you have returned to the beginning of the menu. If you have finished configuring the instrument then press: Suite 5, 56-6 Chandos Street, St. Leonards NSW 065/PO Box 35 Spit Junction NSW 088 Australia Phone +6 9906 758 www.innovec.com page 6

Prog/Run The instrument returns to run mode and all variables are written to non-volatile memory. [It should be noted that if none of the buttons are pressed in a twelve (0) second period the instrument will revert back to run mode without saving any variables to the non-volatile memory.] If a mistake has been made you can cycle through the variables using the button marked: Mode Run Mode Functions. In run mode (when the instrument is operating normally and not being programmed) the push buttons have alternative functions which are: Up button: Displays the current time while the up button is depressed. Down button: Displays the current date while the down button is depressed. Mode button: Displays the background total while the mode button is depressed. Suite 5, 56-6 Chandos Street, St. Leonards NSW 065/PO Box 35 Spit Junction NSW 088 Australia Phone +6 9906 758 www.innovec.com page 7

Rear view of instrument screw terminal arrangement 3 4 5 6 7 8 9 0 3 4 5 6 7 8 9 0 Terminal Terminal Terminal 3 Terminal 4 Terminal 5 Terminal 6 Terminal 7 Terminal 8 Terminal 9 Terminal 0 Terminal Terminal Terminal 3 Terminal 4 Terminal 5 Terminal 6 Terminal 7 Terminal 8 Terminal 9 Terminal 0 Input common (internal 0VDC) input minus input plus Initiate print reset input Not used 85 to 40VAC VAC common supply Ground supply Dip switch DS (located at rear of printer) setting for correct operation Switch Switch Switch 3 Switch 4 On On Off Off Suite 5, 56-6 Chandos Street, St. Leonards NSW 065/PO Box 35 Spit Junction NSW 088 Australia Phone +6 9906 758 www.innovec.com page 8

First line of text (header one) 3 4 5 6 7 8 9 0 3 4 5 6 7 8 9 0 3 4 I N N O V E C C O N T R O L S P T Y L T D Second line of text (header two) 5 6 7 8 9 30 3 3 33 34 35 36 37 38 39 40 T R U C K N O 3 Third line of text (Units of measurement) 4 4 43 44 45 46 47 48 L I T R E S Sample header for the user to fill out [you will find it easier to program when following this map] 3 4 5 6 7 8 9 0 3 4 5 6 7 8 9 0 3 4 Second line of text (header two) 5 6 7 8 9 30 3 3 33 34 35 36 37 38 39 40 Third line of text (Units of measurement) 4 4 43 44 45 46 47 48 L I T R E S Suite 5, 56-6 Chandos Street, St. Leonards NSW 065/PO Box 35 Spit Junction NSW 088 Australia Phone +6 9906 758 www.innovec.com page 9

Appendix : Care of the printer 3. OUTER APPEARANCE AND EXPLANATION OF EACH PART 3. Outer Appearance and Explanation of Each Part Suite 5, 56-6 Chandos Street, St. Leonards NSW 065/PO Box 35 Spit Junction NSW 088 Australia Phone +6 9906 758 www.innovec.com page 0

3. Explanation of Each Part Interface Connector Connected to various hosts via cables. On connection, confirm beforehand that power Supply of the host and the printer are OFF. The power cable, also, is held in this Connector. Make sure to connect FG terminal with an earth. Do not connect this terminal with the Lines except for an earth. Feed Switch With this switch pressed, paper is fed. Use this to insert paper and to put space. With pushing this switch, power is turned on, and self -print function is conducted. 3 Paper Lamp Lights up when paper has become scarce or run out. (Only when Paper Near End/Paper End function has been set.) Put out when paper has been inserted. 4 Knob Use this to set paper or to open the front cover on changing of paper. 5 Front Cover Open/close this on setting or changing of paper. 6 Ribbon Cover Open/close this to change ink ribbon. This opens when the left side of the front face is pulled forward. 7 Mounting bracket Use this to fix the main body to a rack, etc. 8 Paper Holder Paper setting. Suite 5, 56-6 Chandos Street, St. Leonards NSW 065/PO Box 35 Spit Junction NSW 088 Australia Phone +6 9906 758 www.innovec.com page

4.3 Panel Opening/Closing 4.3. Opening/Closing of Front Panel () Applying your finger on the projection on the left side of the front panel, pull it forward when the lock is released. It opens by about 80, centred on the fixed axis. () For closing, pressing the front panel, tightly close it until click sound is heard. Also, confirm, on closing, that paper is free of slackening. 4.3. Opening/Closing of Ribbon Cover () When paper is out of the front cover, cut it of f. () Applying your finger on the dent on the left side of the ribbon cover, pull it forward. It opens by about 80 centring on the fixed axis. (3) For closing, pressing the ribbon cover, close it tightly. 4.4 Paper Feeding With the LF switch pressed once, paper is fed by one line. Paper is fed while it is continuously pressed. To feed paper, do not pull it forcibly. Use the LF switch. During pressing the LF switch, the data can not be received. 4.5 Setting Ribbon Cassette () Open the ribbon cover. Be sure to turn off power before opening it. () In case the paper is out from front cover, cut the paper or remove this paper. (3) Confirming the correct direction of a new ribbon cassette, insert ribbon between the printing head and the Platen and press cassette down from the knob side. (4) Turning the ribbon cassette knob in the arrowed direction, remove slack. (5) On replacing a ribbon cassette, pull it out as holding the "PULL" part. Suite 5, 56-6 Chandos Street, St. Leonards NSW 065/PO Box 35 Spit Junction NSW 088 Australia Phone +6 9906 758 www.innovec.com page

In case the ribbon cassette is kept setting in printer for a long time, this could make the paper dirty. And in case of continuous printing under low temperature, light print may be occurred due to the Characteristic of the ink. Do not conduct printing with no ribbon cassette, this may damage a print head. Replace ribbon cassette before wearing out completely. Use exclusive ribbon cassette. 4.6 Setting Printing Paper () Open the front cover. () Cut the edge of Printing Paper as the following drawing. (3) Insert the paper into the paper insertion of the printer mechanism. When auto loading function is specified, paper is loaded automatically. When auto loading function is not specified, push the LF switch until the paper enters the printer mechanism. (4) By holding the paper holder in the arrowed direction, insert paper roll and make sure paper holder hold the roll. (5) Eliminating slack on the printing paper, close the front panel. (6) To change paper, as holding the paper holder in the arrowed direction, re-move the core. Remove, at this time, excessive paper by using the LF switch. After setting the paper, press LF switch once. Then, printer goes to data input printing mode. Keeping the paper winding direction correct. While replacing of paper, do not send data from host terminal. Do not pull the paper in reverse direction of paper feed. This may cause abnormality of print head. In case the paper is fed diagonally in paper supplying side or paper removing side, paper jam may occur. In this case, turn OFF the power switch immediately and pull out the excessive paper slowly at straight direction. Suite 5, 56-6 Chandos Street, St. Leonards NSW 065/PO Box 35 Spit Junction NSW 088 Australia Phone +6 9906 758 www.innovec.com page 3

4.8 Paper near End Sensor, Paper End Sensor, and Mechanical Alarm 4.8. Paper near End When the paper is getting low, the paper near end is detected and printing is stopped. Power supply to the printing solenoid and motor is immediately stopped and BUSY PE signals are outputted to the host. When data still exists in the input buffer, the remaining data in the buffer is printed before stopping. Discharge remaining paper with the LF switch, set new paper and push the LF switch. Then normal print mode is created after cancellation of BUSY and PE output. This function can be selected by Dip Switch setting. Suite 5, 56-6 Chandos Street, St. Leonards NSW 065/PO Box 35 Spit Junction NSW 088 Australia Phone +6 9906 758 www.innovec.com page 4

7. DIP SWITCH SETTING DS Switch Function Off On Factory Setting Number Character Direction Normal Inverted Off CR command Ignore CR CR+LF Off 3 Reset In Disable Enable On 4 Memory Switch Disable Enable Off Changes in setting are according to destination. Hex. Dump mode is not available with 4 columns version. Serial Printer Switch # Function OFF ON Factory setting Bit length 8 bits 7 bits OFF Parity NO YES ON 3 Parity Conditions Odd Even OFF 4 Baud rate See table below See table below OFF 5 Baud rate See table below See table below ON Baud Rate (bps) Setting Switch #,00,400 4,800 9,600 4 OFF ON OFF ON 5 OFF OFF ON ON * DS setting is available only for Serial interface Suite 5, 56-6 Chandos Street, St. Leonards NSW 065/PO Box 35 Spit Junction NSW 088 Australia Phone +6 9906 758 www.innovec.com page 5