Imaging protocols for navigated procedures

Similar documents
[PDR03] RECOMMENDED CT-SCAN PROTOCOLS

icatvision Quick Reference

CT Protocol Clinical Graphics Move Forward 3D motion analysis service

Slide 1. Technical Aspects of Quality Control in Magnetic Resonance Imaging. Slide 2. Annual Compliance Testing. of MRI Systems.

Advanced Visual Medicine: Techniques for Visual Exploration & Analysis

WayPoint Navigator (software version 4.5)

WayPoint Navigator (software version 4.5)

Automatic Subthalamic Nucleus Targeting for Deep Brain Stimulation. A Validation Study

Breast MRI Accreditation Program Clinical Image Quality Guide

Leksell SurgiPlan. Powerful planning for success

CRANIAL TRAJECTORY PLANNING

Optimization of CT Simulation Imaging. Ingrid Reiser Dept. of Radiology The University of Chicago

Advances in Forensic Anthropology

Lucy Phantom MR Grid Evaluation

Biomet PMI. Patient-Matched Implants. CT Protocols

Computational Medical Imaging Analysis Chapter 4: Image Visualization

Catalog Numbers: CMB022, CMB022-AA, CMB022-UP, CMB033, CMB033-AA, CMB033-UP, CMB-CW, CMB-LK

(a Scrhon5 R2iwd b. P)jc%z 5. ivcr3. 1. I. ZOms Xn,s. 1E IDrAS boms. EE225E/BIOE265 Spring 2013 Principles of MRI. Assignment 8 Solutions

CTA HEAD Perfusion AqONE without and with IV Contrast

Leksell SurgiPlan Overview. Powerful planning for surgical success

Technical Publications

CT Basics Principles of Spiral CT Dose. Always Thinking Ahead.

Machine Learning for Medical Image Analysis. A. Criminisi

Brilliance CT Big Bore.

The protocols used to scan the musculoskeletal system are tailored to each patient and

Planmeca ProMax 3D Max CBCT unit

Video Registration Virtual Reality for Non-linkage Stereotactic Surgery

DICOM Correction Item

Profound understanding of anatomy

PLANMECA PROMAX 3D MID CBCT UNIT

HST.583 Functional Magnetic Resonance Imaging: Data Acquisition and Analysis Fall 2008

Technical Publications

Magnetic Resonance Elastography (MRE) of Liver Disease

Lab Location: MRI, B2, Cardinal Carter Wing, St. Michael s Hospital, 30 Bond Street

BLUEPRINT TM 3D Planning Software - v1.4 scan protocol

PH-03: Clinical Photography Production Checklist With The Sony Cybershot T-9 Digital Camera

Using New Features in CDR DICOM 3.5 Software

McKesson Radiology Display Protocol Manual

Solid Capabilities Are Built Into the Supria Plus. Putting You On The Path of High Quality, Cost-Effective CT Scanning

Medical Image Viewer Guide

Nuclear Associates and

icatvision Software Manual

ClinicalConnect TM eunity TM Training Guide

Shadow casting. What is the problem? Cone Beam Computed Tomography THE OBJECTIVES OF DIAGNOSTIC IMAGING IDEAL DIAGNOSTIC IMAGING STUDY LIMITATIONS

One Machine... Mac OS Compatible! Multiple Modalities. ProMax 3D & 3D s

EnSite NavX Navigation and Visualization Technology EnSite Fusion Registration Module Procedure Guide

M R I Physics Course

Improved Navigated Spine Surgery Utilizing Augmented Reality Visualization

RADIOLOGY AND DIAGNOSTIC IMAGING

FastPlan Reference Guide

DICOM VIEWER. Version 3.2. Software User Guide Revision 1.1. Copyright 2017, Brainlab AG Germany. All rights reserved.

Medical Image Synthesis Methods and Applications

How would, or how does, the patient position (chin extended) affect your beam arrangement?

Technical Publications

How to Adjust the 16-Bit CLUT (Color Look Up Table) Editor in OsiriX

Anatomic measurement accuracy: CT parameters and 3D rendering effects

Computer Aided Surgery 8:49 69 (2003)

Bone registration with 3D CT and ultrasound data sets

Digital Imaging and Communications in Medicine (DICOM) Supplement 167: X-Ray 3D Angiographic IOD Informative Annex

Page 1 of 9. Protocol: adult_other_adni3basichumanprotocol25x_ _ _1. 3 Plane Localizer. 3 Plane Localizer PATIENT POSITION

4/19/2016. Deborah Thames R.T. (R)(M)(QM) Theory & Technology and advancement in 3D imaging DBT

Design and performance characteristics of a Cone Beam CT system for Leksell Gamma Knife Icon

ECE1778 Final Report MRI Visualizer

A Virtual MR Scanner for Education

Qualitative Comparison of Conventional and Oblique MRI for Detection of Herniated Spinal Discs

REAL-TIME ADAPTIVITY IN HEAD-AND-NECK AND LUNG CANCER RADIOTHERAPY IN A GPU ENVIRONMENT

S. Guru Prasad, Ph.D., DABR

Tracked surgical drill calibration

PRODUCT DATA. Advanced 128

MSI 2D Viewer Software Guide

Optimisation of Toshiba Aquilion ONE Volume Imaging

MRI Physics II: Gradients, Imaging

1 Filter the search by entering search criteria; 2 Enter a range of dates in which to search. 3 You can filter the search by modality type.

Section 9. Human Anatomy and Physiology

DICOM Overview: Stability and Evolution

An investigation of the potential of rapid prototyping technology for image-guided surgery

BUZZ - DIGITAL OR WHITEPAPER

Image Acquisition Systems

Gamepad Controls. Figure 1: A diagram of an Xbox controller. Figure 2: A screenshot of the BodyViz Controller Panel. BodyViz 3 User Manual 1

New Technology Allows Multiple Image Contrasts in a Single Scan

TomoTherapy Related Projects. An image guidance alternative on Tomo Low dose MVCT reconstruction Patient Quality Assurance using Sinogram

Position accuracy analysis of the stereotactic reference defined by the CBCT on Leksell Gamma Knife Icon

Technical Publications

Data Fusion Virtual Surgery Medical Virtual Reality Team. Endo-Robot. Database Functional. Database

2 Michael E. Leventon and Sarah F. F. Gibson a b c d Fig. 1. (a, b) Two MR scans of a person's knee. Both images have high resolution in-plane, but ha

Corso di laurea in Fisica A.A Fisica Medica 4 TC

Fundamentals of CT imaging

SMARTBRUSH. Version 2.5. Software User Guide Revision 1.0. Copyright 2016, Brainlab AG Germany. All rights reserved.

New Enhanced Multi-frame DICOM CT and MR Objects to Enhance Performance and Image Processing on PACS and Workstations

Medical Image Registration

Digital Imaging and Communications in Medicine (DICOM) Supplement 116: 3D X-Ray Storage SOP Class

ThE ultimate, INTuITIVE Mr INTErFAcE

Technical Publications

Virtual Cath Lab (Free Evaluation) User Guide

How to draw and create shapes

Medical rapid prototyping technologies: state of the art and current limitations for application in oral and maxillofacial surgery

SCENARIA 64-Slice CT Putting Advanced CT Within Reach.

연구용유방초음파질관리 원광대학병원김혜원

Normalization for clinical data

Instructions for Display of Imaging Studies Using Stentor isite

Transcription:

9732379 G02 Rev. 1 2015-11 Imaging protocols for navigated procedures How to use this document This document contains imaging protocols for navigated cranial, DBS and stereotactic, ENT, and spine procedures as well as instructions for placing skin fiducial markers. Work from left to right in the following table to determine which imaging protocol to use and to locate that protocol within this document. Anatomy Procedures Software in which the scans can be used Protocol Location in document Cranial Tumor resection, shunt placement, and biopsy procedures without a stereotactic frame Synergy Cranial Cranial Classic (MACH) PoleStar Navigation Cranial A Page 3 Synergy Cranial (This protocol does not apply if you are using Synergy Cranial software version 2.2.x or earlier.) Cranial B Page 6 DBS and stereotactic procedures FrameLink StimPilot Cranial C Page 12 Synergy Cranial (This protocol does not apply if you are using Synergy Cranial software version 2.2.x or earlier.) Cranial D Page 16 ENT Anterior skull base and sinus procedures Fusion ENT LandmarX element LandmarX env ENT Page 20 Spine All navigated spine procedures Synergy Spine Synergy Spine and Trauma Spine 3D Synergy Experience TLIF Procedure Solution Spine Page 23 If your site is using software that is not listed in the table, contact Medtronic Navigation to obtain the imaging protocol that applies to your software. The most common scan protocols are highlighted in blue. If you have questions about which protocol to use, contact your local Medtronic Navigation Clinical Specialist or call technical support at +1 800 595 9709 or +1 720 890 3160. 9732379 G02 Rev. 1 Medtronic Navigation, Inc. 1

Use the following tables to record the software versions installed on each navigation system at your site. Medtronic Navigation system name Cranial software version FrameLink software version ENT software version Spine software version Date Medtronic Navigation system name Cranial software version FrameLink software version ENT software version Spine software version Date Medtronic Navigation system name Cranial software version FrameLink software version ENT software version Spine software version Date 2 Medtronic Navigation, Inc. 9732379 G02 Rev. 1

Cranial A protocol Cranial A protocol These requirements apply to scans that will be used in the following software: Procedures Procedures without a stereotactic frame Tumor resection Shunt placement Biopsy Software in which the scans can be used Synergy Cranial Cranial Classic (MACH) PoleStar Navigation Cranial A scan requirements Note: If you are using skin fiducial markers, follow the instructions for Fiducial marker placement for cranial scans on page 9. Contrast Contrast agents may be injected before scanning. Slices Scan contiguous slices. (Slice spacing must equal slice thickness. Make sure that there is no gap between slices.) 1 Correct: contiguous slices with no gap and no overlap 2 Incorrect: gap between slices 3 Incorrect: overlap of slices Use a constant slice thickness. Use a slice thickness of 1 mm or less, which usually produces the highest quality data set for surgical planning and navigation. - Any fractional slice thickness up to 3 mm is acceptable. However, as slice thickness increases, surgical planning and navigation performance can be impacted. - 3 mm is the largest slice thickness acceptable for cranial scans. Axial slices are preferred. Size and pixels Use a square image matrix of 256 x 256 pixels or 512 x 512 pixels. Use square pixels. Cranial A CT scans only Use a standard soft tissue algorithm. Do not use gantry tilt. Axial/helical scans are acceptable using a pitch ratio of 1:1. If you use helical scans, make sure that you do not see image artifacts in the reconstructed image slices. Use a circular (or square) field of view (FOV). Use the smallest FOV to encompass the region of interest, which is usually up to 25 cm (250 mm). Include the top of the head, the skull base, and the nose. If the scan will be merged with other scans using StealthMerge software, make sure that there is an air gap around the head. 9732379 G02 Rev. 1 Medtronic Navigation, Inc. 3

Cranial A protocol Cranial A MR scans only Scans to merge Scan region Do not use oblique slices. Scan along the axis of the magnet bore. Use single-echo scans. Do not use multi-echo scans. Any MR imaging sequence can be used to show anatomy/pathology. However, if the scans will be merged, MR-T1, MR-T2, MR-PD, FLAIR, and combinations thereof, have been evaluated and found effective for use with StealthMerge software. Other modalities such as SPGR, MPRAGE, and MRA have not been evaluated. Scans taken in the same Frame Of Reference as the MR-T1, MR-T2, MR- PD, or FLAIR may still be used if merged with Identity Merge. MR 3D volume acquisition is acceptable as long as the scan can be reconstructed in a way that conforms to all requirements of the imaging protocol. If you intend to merge two or more exams using StealthMerge software, ensure that multiple identifiable landmarks and the skull base are included in all of the scans to enable matching. CT, MR-T1, MR-T2, MR-PD, FLAIR, and combinations thereof, have been evaluated and found effective for use with StealthMerge software. Other modalities such as SPGR, MPRAGE, MEG, CTA, and MRA have not been evaluated. If you intend to merge O-arm exams with preoperative exams, you may use any imaging mode, except when using an O-arm O-1000 system. For O-arm O-1000 systems, use the high definition 3D or enhanced cranial 3D modes. Scan from the superior aspect of the horizontal portion of the mandible through the top or vertex of the cranium. Include an air gap above the superior aspect of the head. Include all fiducial markers, the ears, maxillary teeth, and the tip of the nose. Ensure that the tip of the patient's nose is included in the scan and that it is the most anterior point on the scan. Also, start the scan above any dental work to avoid creating artifacts. This image shows the typical scan region for cranial scans (unless the lesion is very low). Patient position Archive format Separate the patient s head from the scanner headrest with towels or foam. Use padding to prevent patient motion, but make sure that the padding does not distort the fiducial markers or the skin. Make sure that the patient's ears do not touch the sides of the headrest, and that they are not pushed away from their normal position. Archive the scan in an uncompressed file format. 4 Medtronic Navigation, Inc. 9732379 G02 Rev. 1

Cranial A protocol Cranial A scan examination The surgeon or imaging technologist should examine the completed scan to verify the following quality criteria: The patient image orientation is correct. The total pathology/region of interest is visible. The planned surgical target and entry points are visible. The tip of the patient's nose is included in the scan and should be the most anterior point on the scan. Having the tip of the patient s nose as the most anterior point on the scan is preferred for the Tracer registration method. The slice thickness is constant throughout the scan. No motion artifact is present. Rapidly scroll through the images to make sure they all line up. Be aware of phase encoding (ghost) artifacts. If necessary, work with radiology to reduce artifacts. The fiducial markers are clearly visible and are not distorted. No gantry tilt was used. All other aspects of the imaging protocol were followed. 9732379 G02 Rev. 1 Medtronic Navigation, Inc. 5

Cranial B protocol Cranial B protocol Procedures Procedures without a stereotactic frame Tumor resection Shunt placement Biopsy Software in which the scans can be used Synergy Cranial (This protocol does not apply if you are using Synergy Cranial software version 2.2.x or earlier.) Cranial B scan requirements Note: If you are using skin fiducial markers, follow the instructions for Fiducial marker placement for cranial scans on page 9. Contrast Contrast agents may be injected before scanning. Slices Scan contiguous slices. (Slice spacing must equal slice thickness. Make sure that there is no gap between slices.) 1 Correct: contiguous slices with no gap and no overlap 2 Incorrect: gap between slices 3 Incorrect: overlap of slices Use a constant slice thickness. Use a slice thickness of 1 mm or less, which usually produces the highest quality data set for surgical planning and navigation. - Any fractional slice thickness up to 3 mm is acceptable. However, as slice thickness increases, surgical planning and navigation performance can be impacted. - 3 mm is the largest slice thickness acceptable for cranial scans. Axial slices are preferred. Size Use a square or rectangular image matrix of up to 1024 x 1024 pixels. Note: Scans that are larger than 512 x 512 pixels cannot be used in Synergy Cranial software version 2.2.x or earlier. 6 Medtronic Navigation, Inc. 9732379 G02 Rev. 1

Cranial B protocol Cranial B CT scans only Cranial B MR scans only Scans to merge Scan region Use a standard soft tissue algorithm. Do not use gantry tilt. Axial/helical scans are acceptable using a pitch ratio of 1:1. If you use helical scans, make sure that you do not see image artifacts in the reconstructed image slices. Use a circular (or square) field of view (FOV). Use the smallest FOV to encompass the region of interest, which is usually up to 25 cm (250 mm). Include the top of the head, the skull base, and the nose. If the scan will be merged with other scans using StealthMerge software, make sure that there is an air gap around the head. Do not use oblique slices. Scan along the axis of the magnet bore. Use single-echo scans. Do not use multi-echo scans. Any MR imaging sequence can be used to show anatomy/pathology. However, if the scans will be merged, MR-T1, MR-T2, MR-PD, FLAIR, and combinations thereof, have been evaluated and found effective for use with StealthMerge software. Other modalities such as SPGR, MPRAGE, and MRA have not been evaluated. Scans taken in the same Frame Of Reference as the MR-T1, MR-T2, MR- PD, or FLAIR may still be used if merged with Identity Merge. MR 3D volume acquisition is acceptable as long as the scan can be reconstructed in a way that conforms to all requirements of the imaging protocol. If you intend to merge two or more exams using StealthMerge software, ensure that multiple identifiable landmarks and the skull base are included in all of the scans to enable matching. CT, MR-T1, MR-T2, MR-PD, FLAIR, and combinations thereof, have been evaluated and found effective for use with StealthMerge software. Other modalities such as SPGR, MPRAGE, MEG, CTA, and MRA have not been evaluated. If you intend to merge O-arm exams with preoperative exams, you may use any imaging mode, except when using an O-arm O-1000 system. For O-arm O-1000 systems, use the high definition 3D or enhanced cranial 3D modes. Scan from the superior aspect of the horizontal portion of the mandible through the top or vertex of the cranium. Include an air gap above the superior aspect of the head. Include all fiducial markers, the ears, maxillary teeth, and the tip of the nose. Ensure that the tip of the patient's nose is included in the scan and that it is the most anterior point on the scan. Also, start the scan above any dental work to avoid creating artifacts. This image shows the typical scan region for cranial scans (unless the lesion is very low). 9732379 G02 Rev. 1 Medtronic Navigation, Inc. 7

Cranial B protocol Patient position Archive format Separate the patient s head from the scanner headrest with towels or foam. Use padding to prevent patient motion, but make sure that the padding does not distort the fiducial markers or the skin. Make sure that the patient's ears do not touch the sides of the headrest, and that they are not pushed away from their normal position. Archiving the scan in an uncompressed file format is preferred. If you compress the scan, use a lossless compression method, such as, JPEG lossless or JPEG2000 lossless. Note: Compressed scans cannot be used in Synergy Cranial software version 2.2.x or earlier. Cranial B scan examination The surgeon or imaging technologist should examine the completed scan to verify the following quality criteria: The patient image orientation is correct. The total pathology/region of interest is visible. The planned surgical target and entry points are visible. The tip of the patient's nose is included in the scan and should be the most anterior point on the scan. Having the tip of the patient s nose as the most anterior point on the scan is preferred for the Tracer registration method. The slice thickness is constant throughout the scan. No motion artifact is present. Rapidly scroll through the images to make sure they all line up. Be aware of phase encoding (ghost) artifacts. If necessary, work with radiology to reduce artifacts. The fiducial markers are clearly visible and are not distorted. No gantry tilt was used. All other aspects of the imaging protocol were followed. 8 Medtronic Navigation, Inc. 9732379 G02 Rev. 1

Fiducial marker placement for cranial scans Fiducial marker placement for cranial scans Note: The following instructions apply to skin fiducial markers (960-991). If you are using a different kind of fiducial marker, follow these recommendations as well as any recommendations from the fiducial marker manufacturer. Although imaging may occur at any time prior to surgery, fiducial markers must remain fixed from the time of scanning until after registration in the navigation software. Instruct the patient not to remove or alter the position of the markers. If a marker falls off after the patient has been scanned, leave it off. Good fiducial marker placement Follow these best practices for fiducial marker placement for Touch-n-Go registration or PointMerge registration. Place 7 to 11 fiducial markers. Distribute the fiducial markers around the patient s head. Choose locations where the skin is taut. Avoid areas with loose skin such as the cheeks and under the eyes. Choose locations where the fiducial markers will not be depressed or shifted when the patient is lying in the scanner or when the patient is positioned for surgery. The mastoid behind the ear is an ideal location for fiducial markers. Place the markers high enough on the mastoid that the scan will encompass them. Place more fiducial markers near the surgical area of interest. It may be helpful to place 2 markers near each other on one side of the head to help the surgeon confirm correct image orientation. Examples of good fiducial marker placement 1 Good fiducial marker placement for anterior and lateral surgical approaches 2 Good fiducial marker placement for posterior surgical approaches 9732379 G02 Rev. 1 Medtronic Navigation, Inc. 9

Fiducial marker placement for cranial scans Poor fiducial marker placement Do not place all fiducial markers in one concentrated location or on one side of the head. Do not place fiducial markers in a symmetrical pattern. That is, do not place markers in the same locations on both sides of the head. Also, do not place the markers such that they form squares or triangles with equal-length sides. Do not place fiducial markers in a repeating pattern. Do not place fiducial markers in a straight line. 10 Medtronic Navigation, Inc. 9732379 G02 Rev. 1

Fiducial marker placement for cranial scans Placing fiducial markers To place the fiducial markers on the patient: 1. Choose a site where the skin is taut. Shave a small patch of hair (approximately one inch square) at the site where you will place the fiducial marker. 2. Clean the site with alcohol to strengthen the marker s adhesion to the skin. Allow the site to dry thoroughly. Note: If the patient is diaphoretic, you may wish to apply adhesive. 3. Remove the paper from the adhesive backing on the marker, and place the marker at the prepared site. Note: Make sure that the center dot is removed from the fiducial marker. 4. Mark the skin with an indelible ink pen through the hole in the center of the fiducial marker. 5. Place 7 to 11 markers in this manner. Distribute the markers around the patient s head as described in the best practices for fiducial marker placement. 6. Ensure positioning in the scanner does not shift any of the fiducial markers. 7. Image the patient according to the appropriate protocol given in this document. 9732379 G02 Rev. 1 Medtronic Navigation, Inc. 11

Cranial C protocol Cranial C protocol Procedures DBS and stereotactic procedures Software in which the scans can be used FrameLink StimPilot Cranial C scan requirements Note: If the patient has WayPoint anchors implanted for the STarFix platform, refer to the instructions for use of the anchors for additional scan requirements. WayPoint anchors and the STarFix platform are products of FHC, Inc. Contrast Contrast agents may be injected before scanning. Slices Scan contiguous slices. (Slice spacing must equal slice thickness. Make sure that there is no gap between slices.) 1 Correct: contiguous slices with no gap and no overlap 2 Incorrect: gap between slices 3 Incorrect: overlap of slices Use a constant slice thickness. Use a slice thickness of 1 mm or less, which usually produces the highest quality data set for surgical planning and navigation. - Any fractional slice thickness up to 3 mm is acceptable. However, as slice thickness increases, surgical planning and navigation performance can be impacted. - 3 mm is the largest slice thickness acceptable for use with the FrameLink and StimPilot software. Axial slices are preferred. Size and pixels Use a square image matrix of 256 x 256 pixels or 512 x 512 pixels. Use square pixels. Cranial C CT scans only Use a standard soft tissue algorithm. Do not use gantry tilt. Axial/helical scans are acceptable using a pitch ratio of 1:1. If you use helical scans, make sure that you do not see image artifacts in the reconstructed image slices. Use a circular (or square) field of view (FOV). Use the smallest FOV to encompass the region of interest, which is usually 28 cm to 32 cm (280 mm to 320 mm). Include AC/PC structures, target region, entry region (required for frameless scans), and stereotactic frame (required for the registration scan). 12 Medtronic Navigation, Inc. 9732379 G02 Rev. 1

Cranial C protocol Cranial C MR scans only Scans to merge Scan region Do not use oblique slices. Scan along the axis of the magnet bore. Use single-echo scans. Do not use multi-echo scans. Any MR imaging sequence can be used to show anatomy/pathology. However, if the scans will be merged, MR-T1, MR-T2, MR-PD, FLAIR, and combinations thereof, have been evaluated and found effective for use with StealthMerge software. Other modalities such as SPGR, MPRAGE, and MRA have not been evaluated. Scans taken in the same Frame Of Reference as the MR-T1, MR-T2, or MR-PD may still be used if merged with Identity Merge. MR 3D volume acquisition is acceptable as long as the scan can be reconstructed in a way that conforms to all requirements of the imaging protocol. If you intend to merge two or more exams using StealthMerge software, ensure that multiple identifiable landmarks and the skull base are included in all of the scans to enable matching. CT, MR-T1, MR-T2, MR-PD, FLAIR, and combinations thereof, have been evaluated and found effective for use with StealthMerge software. Other modalities such as SPGR, MPRAGE, MEG, CTA, and MRA have not been evaluated. Scan from the superior aspect of the horizontal portion of the mandible through the top or vertex of the cranium. Include an air gap above the superior aspect of the head. Include bone fiducial markers, the ears, maxillary teeth, and the tip of the nose. Ensure that the tip of the patient's nose is included in the scan and that it is the most anterior point on the scan. Also, start the scan above any dental work to avoid creating artifacts. These images show the typical scan region for DBS scans. Include the localizer frame with the 9 required rods in a stereotactic scan (see Figure 1 on page 15 for more information). Minimize the angle between the vertical localizer rods and the superior-inferior image axis. 1 Scan region without localizer 2 Superior-inferior image axis 3 Ideal scan region with minimal localizer tilt 4 Too much angle between the vertical localizer rods and the superior-inferior image axis 9732379 G02 Rev. 1 Medtronic Navigation, Inc. 13

Cranial C protocol Patient position Make sure that the patient anatomy is oriented as close as possible to LPS space (the left-right, anterior-posterior, and inferior-superior axes). Separate the patient s head from the scanner headrest with towels or foam. Use padding to prevent patient motion, but make sure that the padding does not distort the fiducial markers or the skin. Make sure that the patient's ears do not touch the sides of the headrest, and that they are not pushed away from their normal position. Archive format Archive the scan in an uncompressed file format. Cranial C scan examination The surgeon or imaging technologist should examine the completed scan to verify the following quality criteria: The patient image orientation is correct, and the patient anatomy is lined up with the left-right, anterior-posterior, and inferior-superior axes. The total region of interest is visible. The planned surgical target and entry points are visible. The tip of the patient's nose is included in the scan and should be the most anterior anatomical point on the scan. The slice thickness is constant throughout the scan. No motion artifact is present. Rapidly scroll through the images to make sure they all line up. Be aware of phase encoding (ghost) artifacts. If necessary, work with radiology to reduce artifacts. No gantry tilt was used. For stereotactic scans, the 9 required rods are visible and are in the correct orientation. Rods 1 through 9 (shown in Figure 1) are required for each frame. 14 Medtronic Navigation, Inc. 9732379 G02 Rev. 1

Cranial C protocol 1: Figure 1: Rod numbering 1 Fischer frames 2 Leksell CT frames 3 Leksell MR frames 4 Integra CRW frame: BRW-LF (CRW is a trademark of Integra Burlington MA, Inc.) 5 Integra CRW frames: Luminant CT and UCLF CT Note: The rod numbers shown in parentheses may not be available on all versions of the frames. All other aspects of the imaging protocol were followed. 9732379 G02 Rev. 1 Medtronic Navigation, Inc. 15

Cranial D protocol Cranial D protocol Procedures DBS and stereotactic procedures Software in which the scans can be used Synergy Cranial (This protocol does not apply if you are using Synergy Cranial software version 2.2.x or earlier.) Cranial D scan requirements Note: If the patient has WayPoint anchors implanted for the STarFix platform, refer to the instructions for use of the anchors for additional scan requirements. WayPoint anchors and the STarFix platform are products of FHC, Inc. Contrast Contrast agents may be injected before scanning. Slices Scan contiguous slices. (Slice spacing must equal slice thickness. Make sure that there is no gap between slices.) 1 Correct: contiguous slices with no gap and no overlap 2 Incorrect: gap between slices 3 Incorrect: overlap of slices Use a constant slice thickness. Use a slice thickness of 1 mm or less, which usually produces the highest quality data set for surgical planning and navigation. - Any fractional slice thickness up to 3 mm is acceptable. However, as slice thickness increases, surgical planning and navigation performance can be impacted. - 3 mm is the largest slice thickness acceptable for cranial scans. Axial slices are preferred. Size Cranial D CT scans only Use a square or rectangular image matrix of up to 1024 x 1024 pixels. Note: Scans that are larger than 512 x 512 pixels cannot be used in Synergy Cranial software version 2.2.x or earlier. Use a standard soft tissue algorithm. Do not use gantry tilt. Axial/helical scans are acceptable using a pitch ratio of 1:1. If you use helical scans, make sure that you do not see image artifacts in the reconstructed image slices. Use a circular (or square) field of view (FOV). Use the smallest FOV to encompass the region of interest, which is usually 28 cm to 32 cm (280 mm to 320 mm). Include AC/PC structures, target region, entry region (required for frameless scans), and stereotactic frame (required for the registration scan). 16 Medtronic Navigation, Inc. 9732379 G02 Rev. 1

Cranial D protocol Cranial D MR scans only Scans to merge Scan region Do not use oblique slices. Scan along the axis of the magnet bore. Use single-echo scans. Do not use multi-echo scans. Any MR imaging sequence can be used to show anatomy/pathology. However, if the scans will be merged, MR-T1, MR-T2, MR-PD, FLAIR, and combinations thereof, have been evaluated and found effective for use with StealthMerge software. Other modalities such as SPGR, MPRAGE, and MRA have not been evaluated. Scans taken in the same Frame Of Reference as the MR-T1, MR-T2, MR- PD, or FLAIR may still be used if merged with Identity Merge. MR 3D volume acquisition is acceptable as long as the scan can be reconstructed in a way that conforms to all requirements of the imaging protocol. If you intend to merge two or more exams using StealthMerge software, ensure that multiple identifiable landmarks and the skull base are included in all of the scans to enable matching. CT, MR-T1, MR-T2, MR-PD, FLAIR, and combinations thereof, have been evaluated and found effective for use with StealthMerge software. Other modalities such as SPGR, MPRAGE, MEG, CTA, and MRA have not been evaluated. If you intend to merge O-arm exams with preoperative exams, you may use any imaging mode, except when using an O-arm O-1000 system. For O-arm O-1000 systems, use the high definition 3D or enhanced cranial 3D modes. Scan from the superior aspect of the horizontal portion of the mandible through the top or vertex of the cranium. Include an air gap above the superior aspect of the head. Include bone fiducial markers, the ears, maxillary teeth, and the tip of the nose. Ensure that the tip of the patient's nose is included in the scan and that it is the most anterior point on the scan. Also, start the scan above any dental work to avoid creating artifacts. These images show the typical scan region for DBS scans. Include the localizer frame with the required rods in a stereotactic scan. If the frame will be registered manually in the software, rods 1 through 9 are required in the scan (see Figure 2 page 19 for more information). If the frame will be registered automatically in the software, at least 6 rods are required in the scan, and at least 1 of the 6 must be a diagonal rod. However, consider including rods 1 through 9 in case manual frame registration becomes necessary. 9732379 G02 Rev. 1 Medtronic Navigation, Inc. 17

Cranial D protocol Minimize the angle between the vertical localizer rods and the superior-inferior image axis. 1 Scan region without localizer 2 Superior-inferior image axis 3 Ideal scan region with minimal localizer tilt 4 Too much angle between the vertical localizer rods and the superior-inferior image axis Patient position Archive format Separate the patient s head from the scanner headrest with towels or foam. Use padding to prevent patient motion, but make sure that the padding does not distort the fiducial markers or the skin. Make sure that the patient's ears do not touch the sides of the headrest, and that they are not pushed away from their normal position. Archiving the scan in an uncompressed file format is preferred. If you compress the scan, use a lossless compression method, such as, JPEG lossless or JPEG2000 lossless. Note: Compressed scans cannot be used in Synergy Cranial software version 2.2.x or earlier. Cranial D scan examination The surgeon or imaging technologist should examine the completed scan to verify the following quality criteria: The patient image orientation is correct, and the patient anatomy is lined up with the left-right, anterior-posterior, and inferior-superior axes. The total region of interest is visible. The planned surgical target and entry points are visible. The tip of the patient's nose is included in the scan and should be the most anterior anatomical point on the scan. The slice thickness is constant throughout the scan. No motion artifact is present. Rapidly scroll through the images to make sure they all line up. Be aware of phase encoding (ghost) artifacts. If necessary, work with radiology to reduce artifacts. No gantry tilt was used. 18 Medtronic Navigation, Inc. 9732379 G02 Rev. 1

Cranial D protocol For stereotactic scans make sure that the required rods are visible and are in the correct orientation. If the frame will be registered manually in the software, rods 1 through 9 are required. If the frame will be registered automatically in the software, at least 6 rods are required in the scan, and at least 1 of the 6 must be a diagonal rod. However, consider including rods 1 through 9 in case manual frame registration becomes necessary. 2: Figure 2: Rod numbering 1 Fischer frames 2 Leksell CT frames 3 Leksell MR frames 4 Integra CRW frame: BRW-LF 5 Integra CRW frames: Luminant CT and UCLF CT Note: The rod numbers shown in parentheses may not be available on all versions of the frames. All other aspects of the imaging protocol were followed. 9732379 G02 Rev. 1 Medtronic Navigation, Inc. 19

ENT protocol ENT protocol Procedures Anterior skull base and sinus procedures Software in which the scans can be used Fusion ENT LandmarX element LandmarX env ENT scan requirements Contrast Contrast agents may be injected before scanning. Slices Scan contiguous slices. (Slice spacing must equal slice thickness. Make sure that there is no gap between slices.) 1 Correct: contiguous slices with no gap and no overlap 2 Incorrect: gap between slices 3 Incorrect: overlap of slices Use a constant slice thickness. Use a slice thickness of 1 mm or less, which usually produces the highest quality dataset for surgical planning and navigation. - Any fractional slice thickness up to 2 mm is acceptable. However, as slice thickness increases, surgical planning and navigation performance can be impacted. - 2 mm is the largest slice thickness acceptable for use with the ENT application. Axial slices are preferred. Size Use a square image matrix of 256 x 256 pixels or 512 x 512 pixels. Use square pixels. ENT CT scans only Use a standard soft tissue algorithm. Axial/helical scans are acceptable using a pitch ratio of 1:1. If you use helical scans, make sure that you do not see image artifacts in the reconstructed image slices. Use a circular (or square) field of view (FOV). Use the smallest FOV to encompass the region of interest, which is usually up to 25 cm (250 mm). Include the top of the head, the skull base, and the nose. If the scan will be merged with other scans using ENT Scan Merge software, make sure that there is an air gap around the head. Do not use gantry tilt. 20 Medtronic Navigation, Inc. 9732379 G02 Rev. 1

ENT protocol ENT MR scans only Scans to merge Scan region Do not use oblique slices. Scan along the axis of the magnet bore. Use single-echo scans. Do not use multi-echo scans. Any MR imaging sequence can be used to show anatomy/pathology. However, if the scans will be merged, MR-T1, MR-T2, and combinations thereof, have been evaluated and found effective for use with ENT Scan Merge and StealthMerge ENT software. Other modalities such as SPGR, MPRAGE, and MRA have not been evaluated. MR 3D volume acquisition is acceptable as long as the scan can be reconstructed in a way that conforms to all requirements of the imaging protocol. If you intend to merge two or more exams using ENT Scan Merge or StealthMerge ENT software, ensure that multiple identifiable landmarks and the skull base are included in all of the scans to enable matching. CT, MR-T1, MR-T2, and combinations thereof, have been evaluated and found effective for use with ENT Scan Merge and StealthMerge ENT software. Other modalities such as SPGR, MPRAGE, MEG, CTA, and MRA have not been evaluated. Scan from the superior aspect of the horizontal portion of the mandible through the top or vertex of the cranium. Include an air gap above the superior aspect of the head. Include the skull base, the ears, maxillary teeth, and the tip of the nose. Ensure that the tip of the patient's nose is included in the scan and that it is the most anterior point on the scan. Also, start the scan above any dental work to avoid creating artifacts. The image below shows the typical scan region for ENT anterior skull base and sinus procedures. Patient position Archive format Place the patient s head on a headrest, a small firm donut, or a folded towel on the scanner table. If the patient cannot remain still, use a headrest. Separate the patient's head from the headrest with towels or foam. Use padding to prevent patient motion, but make sure that the padding does not distort or shift the skin. Make sure that the patient's ears do not touch the sides of the headrest, and that they are not pushed away from their normal position. Archive the scan in an uncompressed file format. 9732379 G02 Rev. 1 Medtronic Navigation, Inc. 21

ENT protocol ENT scan examination The surgeon or imaging technologist should examine the completed scans to verify the following quality criteria: The patient image orientation is correct. The total pathology/region of interest is visible. The planned surgical target and entry points are visible. The tip of the patient's nose is included in the scan and should be the most anterior point on the scan. Having the tip of the patient s nose as the most anterior point on the scan is preferred for the Tracer registration method. The slice thickness is constant throughout the scan. No motion artifact is present. Rapidly scroll through the images to make sure they all line up. Be aware of phase encoding (ghost) artifacts. If necessary, work with radiology to reduce artifacts. No gantry tilt was used. All other aspects of the imaging protocol were followed. 22 Medtronic Navigation, Inc. 9732379 G02 Rev. 1

Spine protocol Spine protocol Procedures All navigated spine procedures Software in which the scans can be used Synergy Spine Synergy Spine and Trauma Spine 3D Synergy Experience TLIF Procedure Solution Spine scan requirements Contrast Contrast agents may be injected before scanning. Slices Scan contiguous slices. (Slice spacing must equal slice thickness. Make sure that there is no gap between slices.) 1 Correct: contiguous slices with no gap and no overlap 2 Incorrect: gap between slices 3 Incorrect: overlap of slices Use a constant slice spacing. Use a slice thickness of 1 mm or less, which usually produces the highest quality data set for surgical planning and navigation. - Any fractional slice thickness up to 2 mm is acceptable. However, as slice thickness increases, surgical planning and navigation performance can be impacted. - 2 mm is the largest slice thickness acceptable for use with the Spine application. Axial slices are preferred. Size and pixels Use a square image matrix of 256 x 256 pixels or 512 x 512 pixels. Use square pixels. Spine CT scans only Use a standard soft tissue algorithm. Do not use gantry tilt. Axial/helical scans are acceptable using a pitch ratio of 1:1. If you use helical scans, make sure that you do not see image artifacts in the reconstructed image slices. Use a circular (or square) field of view (FOV). Use the smallest FOV to encompass the region of interest, which is usually up to 18 cm (180 mm). Completely encompass all vertebrae of interest, including the spinous and transverse processes. 9732379 G02 Rev. 1 Medtronic Navigation, Inc. 23

Spine protocol Spine MR scans only Do not use oblique slices. Scan along the axis of the magnet bore. Use single-echo scans. Do not use multi-echo scans. Any MR imaging sequence can be used to show anatomy/pathology. MR 3D volume acquisition is acceptable as long as the scan can be reconstructed in a way that conforms to all requirements of the imaging protocol. Scan region Scan coverage should include one-half vertebra above and below the region of interest. This image shows a sample scan region for a lumbar spine scan. 1 Vertebra of interest 2 Minimum scan region When imaging the sacrum, scan past and include the sciatic notches. Archive format Archive the scan in an uncompressed file format. Spine scan examination The surgeon or imaging technologist should examine the completed scan to verify the following quality criteria: The patient image orientation is correct. The total pathology/region of interest is visible. The planned surgical target and entry points are visible. The slice spacing is constant throughout the scan. No motion artifact is present. Rapidly scroll through the images to make sure they all line up. Be aware of phase encoding (ghost) artifacts. If necessary, work with radiology to reduce artifacts. No gantry tilt was used. All other aspects of the imaging protocol were followed. 24 Medtronic Navigation, Inc. 9732379 G02 Rev. 1

Transfer the scan Transfer the scan To transfer a scan to a StealthStation system, archive the scan from the scanner to a CDR/DVR or USB drive, or transfer the scan electronically to the Medtronic Computer-Assisted Surgery system via a DICOM network. Do not archive or transfer scout images. If the StealthStation system includes DICOM query software, users can query the PACS to retrieve images. Assistance For questions about the Imaging Protocols, contact your local Medtronic Navigation Clinical Specialist or call technical support at +1 800 595 9709 or +1 720 890 3160. 9732379 G02 Rev. 1 Medtronic Navigation, Inc. 25