SOLAR. User manual of high security level electronic lock. Gebaude Sicherheitstechnik Vertriebs GmbH, Kassel

Similar documents
SOLAR Basic. Operating instructions for electronic high-security locks

Instruction manual of the electronic lock DFS SB

DO NOT LOSE THIS SHEET - YOUR FACTORY MASTER CODE IS UNIQUE TO YOUR KEYPAD

Q. How do I start using Mānoa Guardian? A. Go to the App Store or Google Play on your mobile device and download the app. Search for Rave Guardian.

Car Video Recorder. RoadRunner 535W. User Manual

REGION: NORTH AMERICA

PC PRIVACY SHIELD. User Manual. PC Privacy Shield

DINB100-SA-KIT Standalone Biometric Kit

B100-SA Standalone Biometric Reader

PASSWORD SHIELD. User Manual

DINB100-SA Standalone Biometric Reader

Riso Comcolor Series

Set Up Your Print. Overview. The main interface has five components: 1. 3D Viewer

Networking for Wide Format Printers

Monitor / 1501 User Manual

AUTOMATION. Operator s Manual MND. Modbus Network Display. DOC Rev. A1, 5/14

WiFi Security Camera User Manual

User Guide for Undergraduate & Postgraduate Students using the Ethics Online Approval System

BW 2050 Manual. Weltech Interna onal Limited INTRODUCTION

Nova-Pro 100 TABLE OF CONTENTS: Safeguards and Precautions

(English Version) R9-User Manual.

Remote Power Management & Monitoring System MODEL: 1RU8126MS USER MANUAL E Lake Mary Blvd. Sanford, FL (407) (800)

WEB TEACHER GUIDE. ebackpack provides a separate Student Guide through our support site at

USER MANUAL. for Windows & Mac

WORKSWELL WIRIS PRO QUICK START GUIDE. FW Version: Release date: 22 nd March, Revision : 1.2 EN

Digital Analy 韜 cs Installa 韜 on and Configura 韜 on

User Guide for Staff and Postgraduate Research Students using the Ethics Online Approval System

[ Safe deposit safes ]

EXERCISE 2: GETTING STARTED WITH FUSION

BT SIP Trunk CRF User Guide - BT Sales / Originator + Specialist

Digital Proximity System Opera on and Maintenance Manual

PowerPal Selectable Voltage 3-Amp Breadboard Power Supply (#32133)

iphone Troubleshoo ng Guide

USER MANUAL. for Windows & Mac. Links to mobile apps, printers and weighers.

Buyer s Guide. Contents. This guide will review how to shop, create requisi ons and track your requisi ons, orders and invoices

OPTIONAL EXERCISE 1: CREATING A FUSION PROJECT PART A

USER MANUAL. Batteries to Power Your World!

USER MANUAL. for Windows & Mac

DINB100-SA Standalone Biometric Reader

UNIVERSAL. Energy Saver Windows PC Stick with IPTV add-on USER GUIDE

USER MANUAL. SW Version: Release date: 12 th February, Revision : 2.3 EN

NDBI040: Big Data Management and NoSQL Databases

DFM Concurrent Costing

Kinetic Switch APP User Manual

AccessPilot Lock Software

2014 INSTRUCTIONS FOR RE-ENROLLING FAMILIES

Special Topic: Automated Report Recipients 5. Crea ng a New Region 6 Adding Districts to Regions 8

electronic license applications user s guide Contents What you need Page 1 Get started Page 3 Paper Non-Resident Licensing Page 10

EDTracker Pro Wired. User Guide

Remote Ticket Entry. System/User Requirements

CC6000 Active Intercept

Permits User s Guide. Submit Application. Upload Files & Pay Fees. Plan Review Process. Final PreScreen. Project Approval. Electronic Plan Review

TT Tracker Basics 4 Accessing and Comple ng Forms 7

Teslights Hybrid Lighting Controls B-PLC Solution

DSD Planning Center Online Tool User Manual

IGMP and MLD Op-miza-on for Mobile Hosts and Routers

About this User Manual

Test Coverage vs Liability - A Healthcare TDM

Users Manual. Operating and Installation Instructions Buffalo River Black Dimaond. Model:ECSL-0601A Electronic Combination Controller

L1.4. LED Studio Light OPERATING INSTRUCTIONS

LED DRIVER inside IP66 IK08 LED STREET LIGHTS. LED Street Lights

MyCouncil. Accredita on Management System Informa on and Naviga on Guide

User s manual Primor 1000 / 3000 / 3010/ Level 5

F-X20FO Fingerprint safe

NT1003 Controller/Receiver

Low Power Modbus GPRS Data Logger

DECLARATION OF CONFORMITY

eforce 150 Keyless Entry Owner s manual & User s guide For Model 3090

ATD Watt Fluorescent Underhood Light Owner s Manual

NSR-N43. Navigation mirror. User manual

Industrial motor controller for brushed DC motors 24 VDC

What is MyDtxt? 2 Why use MyDtxt? 2 Ge ng started and crea ng an account 2 How do I text my customers? 3. How do I get feedback from my customers?

Access Control Manager TM Release Notes

Living. Keyless Connected Smart Door Lock Manual. smart. The smarter way to protect your home

AMPS Snapshot: User Registra on External Users

Integra ng New Technologies and Teaching Strategies to Support Student Success

Physician Reference Guide Paragon Clinician Hub Version 13.0

Mounting and Operating Instructions (Simple Programming) Art.No..: , published: 10/2003

Bluetooth Audio Amplifier Board for Portable Bluetooth Speakers

Free Yourself into the Cloud Taiwan s only Hybrid Cloud specialist using

PR402 v2.0 Installer Manual Rev.C

DIRECT SUPPLIER P RTAL INSTRUCTIONS

RFID/Digital Access Control Keypad

Tele-ECG. Accurate, Connected, Easy. USER MANUAL. Sanjee. Proudly Made In India. ElectroMedicals

VANDAL RESISTANT BACK-LIT WEATHERPROOF ACCESS CONTROL KEYPAD

Microso 埘 Exam Dumps PDF for Guaranteed Success

1. Website/Pages/Stripes/Items/Elements

RefWorks User Quick Start Guide VERSION 5.0

SeedSense 2017 So ware Release Notes

GREISINGER electronic GmbH. D Regenstauf, Hans-Sachs-Straße 26. T-Logg 100. T-Logg 100 E

How do I do my assignments?

MC-200 Users Guide. Installation and Operation Guide for the most advanced audio and communication system available for a motorcycle.

Step by step Guide to Uploading Your ETD to Trace

Industrial motor controller for brushed DC motors 24 VDC

1. Product descrip on copy

Interface Module Adapter SIMATIC S7-300, 400 and 1500

High contrast 3.25 backlit mono LCD screen Screen resolu on 128x64 pixels Screen LCD brightness of 250 lumens for easy viewing in direct sunlight

GREISINGER electronic GmbH. D Regenstauf, Hans-Sachs-Straße 26. T-Logg 120 W -... T-Logg 120 K -...

Key-Value Stores: RiakKV

Rugged Tablet PC. index. Embedded Standard

Transcription:

SOLAR User manual of high security level electronic lock Gebaude Sicherheitstechnik Vertriebs GmbH, 34123 Kassel Wer. 1.1 / 02-2013

Contents General informa on...3 Func ons overview and descrip on...4 1. Opening/Closing...5 2. change...6 3. User crea on and dele on...7 4. Closing mode se ng...8 5. Sound signal volume...9 6. Opening protocol search...10 7. Supercode func ons...11 8. integra on (4 digits rule)...13 9. Time func ons...14 10. Automa c lock ac va on and deac va on...16 11. Hotel func on in lock mode 1...17 12. Power supply...19 14 Restart...19 15. Signal table...20 16. Technical parameters and cer fica on...20 2

General informa on Please read this user manual thoroughly before proceeding with lock se ngs. Each bu on pressing is confirmed by the lock with a sound signal. Finished or interrupted procedures are signalled with a red LED indicator and a sound signal (see signal list) Over a 30 second long pause before data entering causes current entry to be aborted. In case of errors in data entering, each procedure may be interrupted by pressing the Key The lock manages over 10 different 6-digit codes for different users. Thus, in case of each code, the first digit is a user iden fier It is used for iden fica on and it is not a part of the 6-digit code. Regular checks of the safe and opera on module for tampering are advised. If suspicious marks are found, the seller has to be contacted in order to exclude poten al manipula on. The following codes are a factory preset and they have to be changed because of safety reasons. Changes have to be introduced with open doors and closed bolt mechanism (bolts protrude from the door). ID 0 1 2 3 4 5 6 9 1 1 1 1 1 1 SUPER 1 1 1 1 1 1 1 Descrip on of supercode func on and opera on can be found on page 7. The lock must be opened in order to change se ngs. The lock is closed and opened using a motorized mechanism. The bolt mechanism must never be opened if the bolt motor is in mo on. Doing this may result in lock damage. 3

Symbols and their meaning x sec. Hold for X seconds Long signal x sec. Wait X seconds LED lighted / blinking Short signal Only alkaline ba eries should be used, according to technical specifica on found in the appendix to this user manual. 4

Przegląd funkcji i opis User The lock may manage 10 different users. User number 0 is the administrator and the only user who can program the lock. Closing modes The lock may work in safe mode for 10 users, with opening delay and 4 modes of code integra on. Alterna vely, hotel mode may be ac vated for changing users (visitors) and money transport mode with delay for valuables transporters. Cer fica on of 4 digits rule In order to control access to safe, the lock may be programmed for opening with delay and according to 4 digits rule (code integra on). Automa c closing The lock may be closed automa cally using the switch of bolt mechanism. The risk of leaving an open safe is minimized. Lock against manipula on A er entering four invalid opening codes three long sounds signals are emi ed and at the same me red LED controls light up. A five minute long opera on blockade follows, which is visible by intermi ent light of LED controls with 8 seconds interval. If another invalid code is entered a er the blockade, another, five minute long blockade period starts. This mode is suppressed only by entering a valid code. Emergency power supply If the ba ery becomes completely discharged and the lock may no longer be opened, the lock may be connected to an external power supply. In order to do this, please read Chapter 12, Paragraph 2, Emergency power supply. Restar ng If, against the expecta ons, lock opera on is impossible, the lock may be restarted. The restart does not cause loss of or changes to programmed se ngs of the lock. 5

1. Opening/Closing 1.1 Opening Example administrator code. The procedure is iden cal for all 0-9 users. Switching on User ID (0-9) Opening correct error A er a valid code has been entered, one can move the bolt of the lock and open the safe. The handle may be used only a er complete lock opening (LED control flashes 1x). A er an incorrect code has been entered, the procedure may be repeated three more mes. Then, a 5-minute blockade starts (blockade against tampering). 1.2 Closing Ensure that the handle of the locking mechanism is in the closing posi on. Bu on / example Signal Descrip on Closing Closed A er pressing the the opening handle may not be ac vated un l the lock is closed. 6

2. change Example administrator code. The procedure is iden cal for all 0-9 users. Each of the users may change only its own code. Users 1-9 have to be entered first. User 9 is entered into the system as a factory pre-set. User ID (0-9) change start Entering new code Confirma on repe on Confirma on and end Change error Lighted red LED control and long sound signal means that the code has not been changed because of an error while entering code. The old code is inac ve. Ac ons have to be repeated. A er a successive code change, it has to be tested by mul ple opening and closing with open safe doors and closed bolt mechanism. 7

3. User crea on and dele on The administrator (user 0) may enter and delete 1-9 users. User 9 is factory pre-programmed with changed., code which must be deleted or Start user management (ID 1-9) (0 / 1) User ID (1-9) 0 = delete 1 = enter Confirma on and end Entered error Once the user has been entered, its code is set to changed and it must be Lighted red LED control and long sound signal means that because of an error during data entering the user has not been entered or deleted. Ac ons have to be repeated. If the user has already been entered, entering the same user results in code rese ng to and it must be changed again. Forgo en user code may also be restored to factory se ngs. 8

4. Closing mode se ng The lock may be set by the administrator (user 0) in three different modes for different areas of use. Mode Descrip on 0 Safe mode (standard se ng): Programmed opening delay is valid for all users (0-9) 1 Hotel mode: An addi onal guest code may be set. Without entering the guest code the lock may not be closed. Users 0-9 may delete an ac ve guest code. 2 Money transport mode: Programmed opening delay is valid for users 0-6, users 7-9 may open the lock without a delay Mode selec on start (0-2) Mode 0-2 selec on (Table) Confirm and finish Set error Lighted red LED control and a long sound signal means that because of an error during data entering the mode has not been changed. The factory pre-set mode 0 is ac ve. Ac ons have to be repeated. 9

5. Sound signal volume The administrator (user 0) may set the sound signal volume of the lock in a quiet or loud mode. The factory pre-set mode of the signal is (1) loud. Sound regula on start (0 / 1) 0 = quiet 1 = loud Confirm and finish Set error Lighted red LED control and long sound signal means that because of an error during data entering, volume has not been changed. Ac ons have to be repeated. 10

6. Opening protocol reading The lock records the last 32 users who opened it and other important events. This protocol may be read by the administrator (user 0). Reading takes place using different number of sound and op cal signals according to the table below. The last user using the lock is shown as the first one in the recording. Reading start Confirma on start Signal Descrip on Signal Descrip on 1x User 0 8x User 7 2x User 1 9x User 8 3x User 2 10x User 9 4x User 3 11x Supermaster 5x User 4 12x Guest code 6x User 5 13x Mechanical lock 7x User 6 14x Insufficient ba ery voltage 1x User / event separa on 1x Separa on of user pairs during code integra on 11

7. Supercode func ons The supercode is factory pre-set administrator code. (7x1). It may open the lock and reset 7.1 Supercode change The administrator (user 0) may change the supercode. Supercode change start Entering new supercode Confirma on New supercode confirma on = = Confirma on and finish The supercode is not a regular opening code, it is designed for use in emergency situa ons. Factory se ngs must be changed because of safety reasons. Even if the supercode is used as an excep on, and thus is difficult to remember, it should not be noted down. 12

7.2 Opening using the supercode If the administrator code is lost, during an ac ve blockade or if a user is deleted despite ac ve code integra on, the lock may s ll be opened using supercode. ca. 10 sec. Supercode opening start Supercode Opening Open error 7.3 Rese ng administrator code using supercode If the administrator code is lost, if a blockade is ac ve or if a user is deleted despite ac ve code integra on, the lock may s ll be open using supercode. 3 30 sec. Reset start Current supercode Current supercod Confirma on and finish Changed error A er a successful reset, the administrator code is set as must be changed. and it 13

8. integra on (4 digits rule) Ac va on of code integra on func on or 4 digits rule provides the opportunity of opening the lock simultaneously only for 2 users. 8.1 ac va on and deac va on The administrator (user 0) may ac vate and deac vate the func on of code integra on. integra on se ng (0 / 1) 0 = deac va on 1 = ac va on Confirma on Changed error 8.2 Opening using two user codes Switching on User ID (0-9) 1. Entering finish 2. Switching on start User ID (0-9) Opening correct error 14

9. Time func ons The lock may be programmed for delayed opening a er 0-255 minutes, which starts the moment the code has been entered and lock opening takes place a er the programmed delay me. Opening delay is related to opening me window. It defines the me in which the lock may be opened a er the delay period has ended. This me may also be set for a period of 0-255 minutes. 9.1 Opening delay (OD) ac va on/deac va on The administrator (user 0) may ac vate or deac vate delay me. Delay se ngs (000-255) (000-255) 000 = turned off 255 = max. Confirma on of # of minutes Set error 15

9.2 Opening with ac ve opening delay (OD). Switching on User ID (0-9) Delay start 5 sec. 5 sec....... Delay lasts Opening readiness repe on User ID (0-9) Opening Correct error Time window for repeated code entering is programmed by opening me window (standard 5 minutes). A er this period of me, the en re procedure has to be repeated. 9.3 Opening me window se ng (TW) Opening me windows defines period of me in which the lock may be opened a er the delay me. This me may be set by the administrator (user 0). TW se ng (000-255) 001 = 1 min 255 = 255 min (000-255) Repe on of # of minutes Set error 16

10. Automa c lock ac va on and deac va on A switch of the bolt mechanism has to be installed in order to use this func on. If this func on is not ac vated, and the bolt mechanism is not open, the lock will be automa cally blocked a er 60 seconds. The automa c lock allows control over the following func ons: Func on 0 Descrip on Automa c lock deac vated. The lock is closing a er pressing 1 Automa c lock ac vated, switch ac ve. The lock may be blocked. by pressing if only the lock mechanism is closed. 2 Automa c lock without sound signal. The lock is blocked automa cally a er closing the bolt mechanism. 3 Automa c blockade with sound signal. The lock is blocked automa cally a er closing the bolt mechanism. Lack of blockade is signalled by a sound. integra on se ng (0-3) Func on introduc on (Table) Confirma on Changed error 17

11. Hotel func on in closing mode 1 11.1 Guest code programming The lock must be open and may remain closed a er entering the guest code. Guest code Confirma on and finish Set error 11.2 Guest code programming The lock must remain open. Dele on Confirma on and finish Deleted error 18

12. Power supply 12.1 The device is powered by a 9V block ba ery placed in the ba ery compartment (Note: use only alkaline or lithium ba eries). Internal ba ery compartment with a latching cover is accessible with open doors and depending on the cabinet type is located in door casing or directly on the internal side of the doors (take care of proper posi oning of ba ery poles). Ba ery replacement is necessary then, when during lock opening or closing a long sound signal can be heard. Ba eries should be quickly replaced in such a case, because there is no safe guarantee of use a er about ten consecu ve openings. 12.2 Emergency power supply In case of complete ba ery discharge with the safe closed, follow the following procedure. 1. Separate the opera on module from the fixture, gently prying module edge using a flat head screwdriver between bu ons 4 and 7 and 6 and 9. 2. Pull the keyboard with cables out, at ca. 5 cm. 3. Place a new 9V ba ery in both poles, on the bo om side (big on small, small on big). At the same me, hold the keyboard with a finger, between bu ons 0 and 9. 4. Open the safe according to the user manual Opening paragraph. 5. Open the ba ery compartment on the internal side, carefully disconnect the new ba ery from the internal side of the keyboard and replace the used ba ery with it. 6. Carefully insert the keyboard cable into the door and latch the keyboard in the fixture. Taking the keyboard out of the fixture results in markings on the fixtures, it is a desired effect, protec ng against illegal tampering at the lock by unauthorised individuals. One can order a new fixture from the manufacturer, if necessary. 14. Restar ng The restar ng func on is helpful with dele on. In order to do this, press and hold the bu on for at least 30 seconds, then release. A er another 5-10 seconds, a single diode signal combined with a sound is generated, meaning that the restar ng procedurę has been completed. 19

13. Signal table Func on short long LED Sound Data entering func ons Digit entering 1 me x x Star bu on a er entering correct data 1 me x x Star bu on a er entering incorrect data 1 me x x Star bu on a er programming start 3 mes x x Star bu on a er start of supercode entering 3 mes x x Papillary lines reading Con nuous light Opening delay func ons Opening delay start 1 me x x Opening delay lasts (every 8 seconds) 1 me x Opening delay end 2 mes x x Opening window lasts (every 8 seconds) 1 me x x Time window end 2 me x x System monitoring func ons Ba eries discharged 1 me x x Lock opens (as long as motor operates) x Lock open 1 me x x Lock closes (as long as motor operates) x Lock closed 1 me x x Motor blocked electronically 2 mes x x Start of manipula on blockade 3 mes x x Manipula on blockade func ons Manipula on blockade lasts (every 8 Seconds for 5 minutes) 1 me x End of manipula on blockade 2 mes x Opening protocol reading func ons Odczyt numeru użytkownika n+1 mes x x Znak rozdzielający pomiędzy otwarciami 1 me 1 me x Znak rozdzielenia 2 użytkowników 1 me x x 14. Technical parameters and cer fica on The lock has been designed for use in interiors Temperature 10 C 40 C Rela ve humidity 30% - 85% Standby current < 0,1mA Ba ery power supply: 9V nominal (min. 3V under the load of 0,5A/max. 12V for all load levels) 9V ba eries, block ba ery of alkaline or lithium type Ba ery life me under normal use is ca. 2 years. Maximum bol ng force 25 N Lock class II (B), approval number M103343 Tested by VdS-Köln according to VdS 2344:2005-12, VdS 2841: 2005-12 and EN 1300: 2004-06 20