MXPLC. Compact PLC process station. Summary. Application HVAC control systems, data acquisition, interfacing 3 rd party systems.

Similar documents
MXIO. Compact I/O module. Summary. Application Compact I/O module for data acquisition and HVAC control systems. Function

IMIO100 IMIO105. DDC controllers. Summary

mark150s mark150/485s DDC controllers Summary

Small distributed I/O module

HT101. User terminal. Function

Communicative controller for VAV systems

Touch screen operator unit

UC102 basic version with display and knob UC102BL version with display, knob and backlight UC102DK version without knob and display

Communicative heating controller, Ethernet

Evo2. Free programmable room controller. Summary

RXM39.1. PL-Link IO Block. Desigo TRA. Use with PXC3 series room automation station

Expansion Module HZS 541-1S

NMID. Remote control. SAPIM I/O number. SAPIM I/O number NBRN (RS485) ZM100. Relay, 24 VDC - + UO07 UI11 UI10 UI09 UI08 UI07 UI06 UI05 UI04 UI03 UI02

iologik E1200H Series

CLIMATIX STEQ, STCM DATASHEET FOR CONTROLLING, SWITCHING AND MONITORING FUNCTIONS. POWER SUPPLY RELAY OUTPUTS. Power supply. 4.

The ECL Apex 20 is operated by means of either a PC or the ECL Apex Web Panel. Temperature input signals are based on Pt 1000 or 0-10 V.

SATEL I-LINK 100 MB I/O-converter User Guide, Version 1.1

256 MB RAM. 256 MB 32 bits RISC Cortex-A8 600MHz SD Card Slot. N/A USB Host. N/A USB Client

Climatix TM Climatix Controller. For controlling, switching and monitoring functions

Intech Micro 2300-RTD6 analogue input station MODBUS RTU slave application supplementary manual.

AIAS. Technical description

Features and Benefits. Certifications

iologik E2200 Series Smart Ethernet remote I/O with Click&GO Logic Introduction Remote I/O PC-Free Alarm and Control Intelligence

EXOcompact. Third generation freely programmable controllers

iopac 8500 Series Rugged modular RTU controllers Overview Programmable Controllers High Sampling Rate Analog Input Prerecord Feature

Climatix programmable controller

EXOcompact Third Generation Manual

TM221CE40R controller M IO relay Ethernet

RXTP ROOM TEMPERATURE

Arm-based DIN-rail industrial computers with 4 serial ports, 2 LAN ports, 8 DI/DO, and VGA. Features and Benefits. Certifications

INTEGRATED SYSTEMS AND CONTROL, INC. User s Hardware Manual. PCMNET V 7. xx

DATA SHEET Applicable for offshore or nearshore

RTU560 Connections and Settings DIN Rail RTU 560CIG10

iologik 4000 Series Modular remote I/O Introduction iologik E4200 Specifications Remote I/O Slice Form Factor and Flexible I/O Variety

RST ROOM TEMPERATURE TRANSMITTER. Mounting and operating instructions

M-bus web server. Meters and Energy Cost Allocation WTV676-HB6035

T1K MODBUS Base Controller Specifications

iologik E1200 Series Ethernet remote I/O with 2-port Ethernet switch Introduction Remote I/O

UNT1100 Series. Binary Output Jumpers AO2 AO1 AO3 AO4 AOCM AOCM AOCM AOCM AO1. AI Switches Job Information N2 Address. Ref N2+ N2- ADDR 0 = ALL OPEN

RXTH DUAL ROOM SENSOR / SWITCH

User Manual. cmt-svr Startup Guide

MIC-2 MKII, Multi-instrument DATA SHEET

iologik E1200 Series Ethernet remote I/O with 2-port Ethernet switch Introduction Remote I/O Daisy-Chained Ethernet I/O Connection

User Manual. cmt-svr Startup Guide

Cardax FT Controller 3000

TM221CE24R controller M IO relay Ethernet

TM221CE40R controller M IO relay Ethernet

Measuring transducers MI4x0 series Programmable transducers for RTD sensors MI450

EY-EM : Remote I/O module, ecolink

Extruder Controls ExtruVision S

DKG-210 UNIVERSAL INTERNET GATEWAY UNIT

Note: the wiring of the dead-man buttons has been changed since October 2001.

Serial Data DIN Fiber Link System

HPS-M -2 DIFFERENTIAL PRESSURE TRANSMITTER. Mounting and operating instructions

MIC-2 MKII & MIC-2 MKII DIN, Multi-instrument DATA SHEET

Automation stations compact model

USR-TCP Hard version: V2.0 File version: V

Voltage Transducer UMT516 / MT516

Features and Benefits. Certifications

Andover ContinuumTM Infinet II

MIC-2 Multi-instrument DATA SHEET

Intech Micro 2300-A8VI analogue input station MODBUS RTU slave application supplementary manual.

APP 700 Technical Specification

UA-5200 IIoT Communication Server

TM221M16R controller M IO relay

ProData data logger. Ethernet. Pulse inputs and Pulse outputs. Thermistor input. Modbus-Ethernet gateway. Memory 32 MB. Threshold value monitoring

TM221ME16T controller M IO transistor PNP Ethernet

MGate MB3000 Modbus Gateway User Manual

icex-cmtm General specs and Installation guide

PM174 PM174 IEEE1159 ADVANCED POWER QUALITY ANALYZER. Features

CDN503 HIGH DENSITY I/O ADAPTER USER GUIDE

ICP DAS. ICP DAS 2015 M2M WLAN Wireless Solutions

iopac 8020 Series Rugged modular RTU controllers Overview Programmable RTU Controllers Ethernet bypass feature for seamless data transmission

EXOcompact. Freely programmable controller

POL635.XX/XXX POL636.XX/XXX POL638.XX/XXX POL638.70/XXX

Safety: UL508 EMC: CE IEC , IEC Vibration: IEC (2 g s during operation) Warranty

PBSCONTROL. AMS-R4000 Modular RTU. Remote Terminal Unit

Modular controllers CECX

Datasheet. ECB-PTU Series. 1/14. BACnet B-ASC Powered Terminal Unit Programmable Controllers. Overview

iopac 8020 Series Rugged modular RTU controllers Overview Programmable RTU Controllers Ethernet bypass feature for seamless data transmission

Andover ContinuumTM. b3850 Series Terminal Controllers

H3G-48B Production Description

TM221CE40T controller M IO transistor PNP Ethernet

Expansion Port RS485/RS422

DXTH DUCT SENSOR / SWITCH FOR TEMPERATURE AND HUMIDITY. Mounting and operating instructions

iologik 4000 Series (M) Modules

CDN502 HIGH DENSITY I/O ADAPTER USER GUIDE

Machine TV Interface. mtv-100. Memory Processor. I/O Port RTC. Power. Specification. Certificate Software

MC 11 EB-2 Power supply cabinet with external bus, AC version

TM241CEC24R controller M IO relay Ethernet CAN master

Auxiliary Board MP-Bus HZS 562

BACnet B-ASC Powered Terminal Unit Programmable Controllers. Overview

XPSMF35. Product data sheet Characteristics. Preventa safety PLC compact - Profibus DP protocol. Main. Complementary. Safety module name

ProData DATA LOGGER. Chapter 03 ProData data logger. Ethernet. Pulse inputs and Pulse outputs. Modbus-Ethernet gateway. Thermistor input.

GW-7238D J1939 to Modbus TCP Server / RTU Slave Gateway

1. CP430, CP470, CP474, CP770 and CP774

HMISBC Rear Module controller panel - Dig 8 inputs/8 outputs +Ana 4 In/2 Out

Warranty. Warning. Copyright. Contact Us

Automation station, compact series

TM221M16TG controller M IO transistor PNP spring

Transcription:

MXPLC Compact PLC process station Summary The MXPLC is a programmable process station with integrated I/O module with the I/O mix optimized for larger HVAC control applications. The multi-interface process station may be extended with other I/O modules to accommodate plants with more I/Os. MXPLC - BECK RTOS-PPC, for program upload the SoftPLC is used MXPLC-L - Linux, for program upload the SCP protocol is used MXL - processor board with Linux for MXPLC If necessary, MXPLC can be upgraded to a Linux-based MXPLC-L using a processorboard replacement. Application HVAC control systems, data acquisition, interfacing 3 rd party systems Function The I/O part (16 AI, 8 AO, 32 DI, 32 DO) communicates with the PLC over a RS485 data bus. The internal module communicates as a MXIO at COM port 3, address 2. There may be more modules at the same bus, connected over the COM3 port. On the base board there is also a PLC module which contains the PLC processor and memory including the SoftPLC application. The base board hosts all physical interfaces (COM ports and Ethernet). In the case of the MXPLC-L variant, the compiled program is uploaded via the SCP protocol via terminal, see the instructions.: http://domat-int.com/en/products/onlinedocumentation/configuration-program-upload-iplc510. domat MXPLC 03/2018 Subject to technical changes. 1

The communication circuits are galvanically separated and protected against overvoltage. LEDs indicate states of the binary I/Os, red LED flashes for bus communication (TX), system module cycle (RUN), and green LED (ON) indicates supply voltage. The PLC can be mounted on the base plate of the switchboard, or on another flat and smooth surface by two screws. See domat - Technical application notes for connection and function examples. Technical data Supply voltage 18 V 35 V DC, 14 V 24 V AC Consumption max. 20 VA Working environment temperature 0 70 C PLC: Processor Memory MPC5200, 400 MHz, 760 MIPS 64MB RAM, 32 MB Flash, 128 kb NVRAM FRAM Communication: Ethernet Ethernet 10/100BaseT, RJ45 2 LEDs (Link, Data) integrated in the socket RS232 RS485 COM1, COM2 2x CANNON 9 male; pin 2=TX, 3=RX, 5=GND 300... 115 200 bit/s, parity and bits are set in software COM3, COM4 RS485 (K+, K-) 2 separated buses galvanically insulated from each other, insulating voltage 1 kv 300... 115 200 bit/s parity and bits are set in SW maximal bus length 1200 m maximum number of modules depends on requested response time up to 255 addresses, for common HVAC applications use about 300 400 physical data points on the bus Max. number of modules on the bus Analogue inputs up to 255 addresses, maximum number of modules depends on requested response time: for common HVAC applications use about 300...400 physical data points on the bus 8x Pt 1000, resistance 0..1600 Ohm, 0...5000 Ohm 8x 0-10 V DC, Pt 1000, resistance 0..1600 Ohm, 0...5000 Ohm, 0(4)...20 ma selected with jumpers and over the bus (the rest of ranges, for example Pt100, Ni1000, can be transformed from input by predefined transformation in SW of process station ) 2 03/2018 Subject to technical changes. domat MXPLC

Analogue outputs Analogue outputs load Digital inputs Input voltage for log. 0 Input voltage for log. 1 Digital outputs Dimensions 8x 0-10 V DC min. 10k, max. current 10mA each output; outputs are short-circuit protected by current limitation to 20 ma 32x 24V AC/DC voltage must be applied (no dry contacts) max. 5 V AC/DC 18... 30 V DC, 18... 26V AC @ 7mA 32x relay, normally open: 5A/250 V AC, 5A/30 V DC, 750 VA, 90 W 292,3 (h) x 237 (w) x 40 (d) mm (module) 324,3 (h) x 237 (w) x 40 (d) mm (incl. fixtures) Analogue inputs AI1 to AI8 are designed as passive only. The range (0...1600 or 0...5000 ) can be set over the configuration software ModComTool or over SoftPLC IDE. AI9 to AI16 can be set so as to measure - resistance (same as AI1 to AI8), - voltage 0...10V or - current 0...20 ma. The AI9 to AI16 0...20 ma ranges are set over a jumper for each input independently. The jumpers are accessible from outside of the module. Switch settings: Range resistance, passive temperature sensors voltage 0...10 V current 0...20 ma jumper OFF (default) OFF (default) ON All analogue inputs AI1 to AI16 have common ground AGND. The inputs are optically separated from the other parts of the I/O module. For three-wire connection (active sensors, e.g. pressure, humidity), the analogue input ground AGND must be connected with the peripherial 24 V AC power ground. As all I/O types are mutually separated in the module, it is possible to use one common transformer to power both the active peripherials and the MXPLC module. Analogue outputs The 0..10V analogue outputs maximum load is 10 ma, however, they are permanently short-circuit proof and the output current is limited to 20 ma. The outputs are optically separated from the other circuits in the module, and their ground (AGND) is not connected to the analogue inputs ground. For three-wire connection (dampers, valves), the analogue output ground AGND must be connected with the peripherial 24 V AC power ground. As all I/O types are mutually separated in the module, it is possible to use one common transformer to power both the active peripherials and the MXPLC module. domat MXPLC 03/2018 Subject to technical changes. 3

Digital inputs Digital inputs operate with 24 V AC/DC. Each set of eight digital inputs have own common DGND terminals. The inputs are optically separated from the other circuits in the module, and they may be linked to the same transformer or power supply which supplies the MXPLC module. The statuses of the inputs are indicated by LEDs at the front panel of the module. Digital outputs Others Digital outputs are normally open relays with maximum voltage 250 V, 5 A. Each pair of outputs has one common terminal (COM X, Y). The statuses of the outputs are indicated by LEDs at the front panel of the module. COM1 and COM2 The CANNON 9 communication connectors marked as COM1 and COM2 are for free assignment in the PLC program, such as for M-Bus converters, Modbus server for 3 rd party integration, etc. See SoftPLC IDE. COM3 and COM4 Serial RS485 ports for I/O modules, room units, room controllers, 3 rd party integrations, etc. Remember that the internal I/O module is connected to COM3, and the COM3 port must be configured as Modbus RTU to reach the module. Bus End switches: If both set to ON the bus is terminated, in the OFF position the terminating resistors are disconnected. NB. The first and the last module on the bus should have the BUS END on. The K+ and K- terminals link the module with the I/O bus. The DIP switch is accessible through a small aperture close to the K+, K- terminals. Fuse F 2 A Replace only with the same type if fuse broken. TE terminal The TE terminal should be connected to the ground potential (PES, shielding terminal). Ethernet The 10/100 Ethernet RJ45 connector links the MXPLC to - engineering notebook with SoftPLC IDE - web client (if web access is configured) - RcWare Vision SCADA - other process stations for data exchange - other clients (e.g. Domat SoftPLC OPC server) - the Internet for e-mail alarming. Other topologies on request, contact Domat Control System technical support please. Addressing The Modbus address of the internal I/O module is set to 2, default communication parameters are 9600, 8, N, 1. 4 03/2018 Subject to technical changes. domat MXPLC

LEDs PWR CONTROL RUN I/O COMx RxD COMx TxD On: MXPLC powered OK. Off: No power applied. On: PLC board booted OK. Off: Booting in progress or error state. Flashing: I/O module OK Off: I/O module problem Flashing: Receiving data at COMx port Off: No data traffic Flashing: Transmitting data at COMx port Off: No data traffic Digital inputs (1..32) input status (On: active, Off: inactive) Digital outputs (1..32) output status (On: active, Off: inactive) Programming The main programming tool is the RcWare SoftPLC package which contains I/O editor, graphical editor of the function plan, compiler (RcWare SoftPLC IDE), and LCD menu editor as well as touchscreen and web interface editor (RcWare SoftPLC HMI Editor). The application program consists of function blocks which are stored in libraries. Those contain analogue and digital functions, mathematical blocks including goniometric functions, time schedulers, alarm blocks, and HVAC specific blocks (heat recovery, dewpoint calculation, enthalpy, pump switch etc.). The application (project) is uploaded into the process stations using RcWare SoftPLC IDE. The installation package RcWare SoftPLC, manual and videotutorials are available at www.domat.cz. domat MXPLC 03/2018 Subject to technical changes. 5

Limitations RoHS notice Safety note Number of communication channels (on the serial lines and Ethernet) to I/O modules and subsystems: max. 5, from this max. 3 of the same type (e.g. 3x Modbus RTU / serial, 2x DALI over M090) Number of connections from clients: max. 5. This includes connections from RcWare Vision, IDE, Touchscreen application, LCD menu, browser to internal web server, connection from other PLCs over SoftPLC Link etc. Communication drivers: The MXPLC and MXPLC-L versions differs considerably by the number of communication protocols supported. For a current list of supported protocols, see www.domat-int.com/en/downloads/technical-documentation - List of supported protocols. MXPLC-L does not include a web server, the MXPLC version contains web server. Program upload is only posssible in a local network (LAN). If a remote program upload over the Internet is required, security rules must be observed to prevent the building control system from network attacks. A VPN or similar technology is recommended to access the PLC from the Internet. The device contains a non-rechargeable battery which backups the real-time clock and part of the memory. After the device is not operable, please return it to the manufacturer or dispose of it in compliance with local regulations. The device is designed for monitoring and control of heating, ventilation, and air conditioning systems. It must not be used for protection of persons against health risks or death, as a safety element, or in applications where its failure could lead to physical or property damage or environmental damage. All risks related to device operation must be considered together with design, installation, and operation of the entire control system which the device is part of. 6 03/2018 Subject to technical changes. domat MXPLC

Terminals Jumpers for 0(4)..20 ma input range (remember to configure in the software as well) INIT: init of the I/O module (9600 bps, N, 8, 1) USR1: disable PLC runtime USR2: Converter mode PLC USR3: reserved not used Bus End COM4 Bus End COM3 domat MXPLC 03/2018 Subject to technical changes. 7

Changes in versions 04/2015 Change of AI definition, and resistence range, additional info about transformation for the rest of measuring elements was added. 08/2015 Change of power supply parameters. 02/2016 Limitations added. 08/2016 Add information about COM3 maximal baud rate. 02/2018 Added Safety note, added note about versions, change image. 03/2018 Added information about supported communication protocols and web server support. 8 03/2018 Subject to technical changes. domat MXPLC