easyraid Q24P2-U4R4 Hardware Manual

Similar documents
JanusRAID SA-6692J Hardware User Manual

ERQ12+U4R2 Ultra 320 SCSI to Serial ATA II & ERQ12+F2R2. Fibre Channel to Serial ATA II. Hardware User Manual. Disk Array System.

Sivy SA-4327S Hardware User Manual

easyraid Q16 Hardware User Manual

QIT600F1 USER'S GUIDE

easyraid X16P U3R4 Ultra 160 SCSI to IDE Disk Array System User s Guide P/N. G414241

Chapter 2: Disassembly

YST-SW20 SUBWOOFER SYSTEM OWNER S MANUAL. Active Servo Technology

Arena DeskForce II. Ultra 160 SCSI to IDE Disk Array System User s Guide P/N. G414239

Table of Contents Quick Install Guide page Introduction Safety Rack System Precautions ESD Precautions...

Emerson Network Power provides customers with technical support. Users may contact the nearest Emerson local sales office or service center.

ZOTAC VR GO 2.0. User s Manual

Network Camera. Quick Guide DC-B1203X. Powered by

The power behind competitiveness. Delta Infrasuite Power Management. Power Distribution Unit. User Manual.

Dell MD1280 Storage Enclosure Getting Started Guide

VOICE-ACTIVATED INTERCOM SYSTEM

DNS User Manual. Version Dec DataON Storage, storage division of Area Data Systems.

Prestigio P371 Users manual

SUBWOOFER SYSTEM YST-MSW10

Upgrading and Servicing Guide

3-Phase, Dual-Input 6-Slot Power Supply System STARTUP GUIDE

Obtaining Documentation and Submitting a Service Request, page xvii Safety Warnings, page xvii Safety Guidelines, page xx

AMS Series. Fanless System

Omnitron Systems Technology, Inc. 1. iconverter. 19-Module Managed Power Chassis User s Manual

ZOTAC ZBOX User s Manual

Installing the Cisco ADE 2130 and 2140 Series Appliance Hardware Options

ZOTAC VR GO. User s Manual

Installing the Cisco Unified Videoconferencing 3545 MCU

INSTRUCTION MANUAL DISTRIBUTION UNIT. Please read this manual thoroughly before use, and keep it handy for future reference.

Model 2380 Rack-Mount Kit

Junos WebApp Secure 5.0 Hardware Guide

iops-18 User Manual 2013 Oct V1 IBASE Technology Inc.

EVO-TM2A EVO-TM2B Touch Screen Monitor

HP UPS R/T3000 ERM. Overview. Precautions. Installation Instructions

Installation Manual. 65 Interactive LED/LCD. Model: HILF65101 (64.56 )

SAS to SAS/SATA JBOD Subsystem. User Manual. Revision 1.2

Upgrading and Servicing Guide

Installation Manual. Mounting Instructions Mechanical Mounting. Luminato. Teleste Corporation

DS-1H05 Ethernet-over-Coax Extender. User Manual

Unified Office Gateway UMG Quick Installation Guide. Version: 1.0

Upgrading and Servicing Guide

BS 287 DUAL CHANNEL POWER SUPPLY. User Manual. January 2017 V1.0

User Manual. 1U LCD Keyboard Drawer. KwikDraw - A Series. Manual. IT and Instrumentation for industry. - With KVM options - 15", 17, 19 screen size

SAS to SAS/SATA JBOD Subsystem. User Manual. Revision 1.1

EMC1600 Series Media Converter and Ethernet Extender Chassis

SAS to SAS/SATA JBOD Subsystem. User Manual. Revision 1.1

64 Bays SAS to SAS/SATA JBOD Subsystem. User Manual. Revision 1.0

Table of Contents. Federal Communications Commission (FCC) Statement...2

PNP415/417 POP 'N PLUG WITH CUSTOM TABLETOP SURFACE USER'S GUIDE

Installation Manual. Model: HILU Ultra HD Interactive Flat Panel Display

VTPC190V / VS / VDC / VSDC

Taurus Super-S3 LCM. Dual-Bay RAID Storage Enclosure for two 3.5-inch Serial ATA Hard Drives. User Manual March 31, 2014 v1.2

Installation Job Aid for VSP 4850GTS

iosafe SERVER 5 Quick Start Guide

ISDN 8510T Voice Terminal Instructions for Changing the EPROM

Handbuch. DAVIDE Mini PC GRAFENTHAL

Rocsecure NE52 NAS System

actilib Library 2U Quick Start Guide

User s Guide. Mobile Rack Device Mounting Kit for Echo Express III-R and xmac Pro Server. Quick Start Guide Video Available Online!

SPECIAL APPLICATION MANUAL PART NUMBER: TNP121UL. Tilt N Plug Jr. Table Top Interconnect Box USER'S GUIDE

THE BULLET. Bluetooth Speaker with NFC Technology. Instruction Manual

QK5P1000-Manual_Cover-135x135mm_PrintReady.eps 1 2/7/ :52:09 AM CMY 291-MB384-01S4F

Removal and Installation8

4170 POS System Installation Guide

ZOTAC ZBOX User s Manual

Upgrading and Servicing Guide

Installation Job Aid for VSP 4450GTX-HT- PWR+

ZOTAC ZBOX. User s Manual

MultiPlex 15 Touch Screen. User s Manual

Version /11/2015. User Manual. PowerLine AV HD Gigabit Passthrough Kit DHP-P601AV

ZOTAC ZBOX. User s Manual

Mercury Helios ASSEMBLY MANUAL & USER GUIDE

FUSION RX1600RAID. Rackmount 16-Drive SATA Storage System with Internal SAS Expanders. Drive Enclosure User s Guide

LVN5200A-R2, rev. 1, Hardware Installation Guide

16-SLOT IN-BAND MANAGEMENT CHASSIS

Taurus Mini Super-S3. Dual-Bay RAID Storage Enclosure for two 2.5-inch Serial ATA Hard Drives. User Manual March 31, 2014 v1.1

BS 181 SINGLE CHANNEL POWER SUPPLY USER MANUAL

Thank you for selecting UTC RETAIL s innovative Model 1170 Point of Sale solution!

Network Camera. Quick Guide DC-D1223WX. Powered by

DC-V3213XJ-4.3mm DC-V3213XJ-2.5mm

WARNINGS AND PRECAUTIONS... 3 PACKING LIST... 5 FRONT PANEL... 5 REAR PANEL... 6 MENU SETTINGS... 7 EXAMPLE SETUP SPECIFICATIONS...

ZOTAC ZBOX nano. User s Manual

FUSION 400. User s Guide. 4-Bay Serial ATA Hot-Swap Drive Enclosure. For Windows

Taurus Mini Super-S LCM

OWNER'S MANUAL. Model:PSV Amp SWITCHING DC POWER SUPPLY.

Model 2380 Rack-Mount Kit

EVO-TP Hardware System

MT /12-Slot Digital MultiTasker

BS 181 SINGLE CHANNEL POWER SUPPLY USER MANUAL

PCM60A 100W MAX P.A. AMPLIFIER.

HP UPS R/T3000 G2. Overview. Precautions. Kit contents. Installation Instructions

iosafe BDR515 Hardware Guide

ANI SWH. PDU: Per Outlet Control and Total Current Monitoring INSTRUCTION MANUAL

DSS Console and DSS Console for Attendant for Digital Super Hybrid Systems. Reference Guide ANSWER RELEASE

SATA II HDD Canister KISS DA 435 Quick Reference Guide

HARD DRIVE EXPANSION BAY DESIGNED FOR THE DIGIMERGE BLADE

SAS JBOD Installation Reference Guide Revision 1.0

Hospitality Telephones User Guide

1 Channel Strobe Controller ORDERCODE 40226

291-MB333-04P7F EN1070K

Transcription:

easyraid Q24P2-U4R4 Hardware Manual 42-30000-5105 SCSI Channel to Serial ATA II Disk Array System Version 1.0

easyraid Q24P2-U4R4 U320 SCSI Channel to Serial ATA II Disk Array System Hardware User Manual

Table of Contents Preface... i Chapter 1 System Requirements Operating Environment...1 VT100 Terminal Settings...1 Host Interface...2 Chapter 2 Basic Configuration Unpacking...3 Components...5 Closed Front Panel...5 Open Front Panel...6 Disk Tray...7 Rear View...8 Installing Disks...9 Making Connections...11 Connecting the Host Interface...11 Connecting a network...12 Connecting and Turning on the Power...12 Mounting in a Rack...13 Installing the Rail Extenders...14 Chapter 3 Maintenance Replacing a Disk...15 Replacing a Power Supply...16 Upgrading Memory...19 Appendix Hardware Specifications...21 i

Preface About this Manual This manual is designed to make the disk array system as easy to use as possible. Information contained in this document has been checked for accuracy, but no guarantee is given that the contents are correct. Information and specifications are subject to change without notice. Copyright Notice Copyright 2008 All rights reserved. This disk array system and related documentation are protected by copyright and are distributed under licenses restricting their use, copying, and distribution. No part of this documentation may be reproduced in any form by any means without prior written authorization and its licensors, if any. Conventions Caution This symbol is used to remind users to pay attention to important descriptions regarding usage and maintenance (repair) or additional important information related to this disk array system. Note This symbol is used to remind users of useful information that can make procedures such as configuration easier to accomplish. i

easyraid Q24P2-U4R4 Serial ATA II Disk Array System Important Safety Instructions, Care and Handling Preface Important Safety Instructions, Care and Handling Before starting, take a few minutes to read this manual. Read all of these instructions and save this manual for later reference. Protect the disk array system from extremely high or low temperatures. Let the disk array system warm (or cool) to room temperature before using it. Protect the disk array system from being bumped or dropped. Do not place the disk array system on an unstable cart, stand, or table. It may fall, causing serious damage to the product. Keep the disk array system away from magnetic forces. Do not use the disk array system near water. Keep the disk array system away from dust, sand, or dirt. Gaps and openings in the cabinet are provided for ventilation. Never block or cover these openings, because the disk array system may overheat and become unreliable. Don t place the disk array system on a bed, sofa, rug, or other similar surface. Do not place the disk array system near or over a radiator or other heat source. V Refer to the rating plate for the correct voltage and ensure that the appliance voltage corresponds to the supply voltage. ii

Fan 1 Power 1 easyraid Q24P2-U4R4 Serial ATA II Disk Array System The appliance must be grounded. The disk array system is equipped with a 3-wire grounded type of power cord. This power cord will only fit into a grounded type of power outlet. If an extension cord or a power center is used with the disk array system, make sure that the total current consumption of all products plugged into the wall outlet does not exceed the ampere rating. Do not place the disk array system where the cord will be walked on. Never push any kind of object into the disk array system through cabinet gaps and openings, since they may touch dangerous voltage points and cause a risk of fire or electric shock. Unplug the power cord from the wall outlet before cleaning. Keep the disk array system dry. Do not use liquid cleaners, aerosol cleaners, or a wet cloth. Use a damp cloth for cleaning. Except as specifically explained in this User Manual, do not attempt to service the disk array system by yourself. Opening or removing the covers may expose you to dangerous voltages. Preface Important Safety Instructions, Care and Handling Unplug this product from the wall outlet and refer servicing to qualified service personnel under the following conditions. If the disk array system has been exposed to water or any liquid. If the disk array system has been dropped or the cabinet damaged. Users should not remove the cover. Disconnect all power supply cords before servicing. iii

easyraid Q24P2-U4R4 Serial ATA II Disk Array System Placement Notes Preface Important Safety Instructions, Care and Handling The disk array system LCD panel can be damaged by exposure to direct sunlight. Limit exposure to subdued or indirect sunlight only. The disk array system should be used only in clean environments that are free from airborne contaminants such as dust, dirt, and smoke. Excessive moisture or oil particles in the air can also hinder disk array system performance. To reduce the possibility of data errors caused by electromagnetic interference, locate the disk array system at least five feet away from electrical appliances and equipment that generates magnetic fields. Power Supply Safety Notes To avoid electric shocks, do not use an extended power cord or an outlet that does not match the disk array system plug or leaves the plug exposed. The disk array system has a 3-wire grounded plug. The third pin connects to ground; do not remove it. If the power cord or plug is damaged or worn, unplug it immediately and contact a qualified service technician for maintenance. To avoid fire or electric shocks, do not overload electric power outlets. CAUTION : MULTIPLE POWER SOURCES Disconnect all AC power cords to completely power from the unit CAUTION Risk of explosion if battery is replaced by an incorrect type. Dispose of used batteries according to the instructions. CAUTION The thumbscrews on the rear surface shall be secured by the screwdriver, which cannot be loosened by bare hands to prevent the unintentional access to the hazardous parts inside the equipment. iv

1 System Requirements Ensure that the following requirements are met before installing the disk array system. Operating Environment 15 cm (6-inches) of space around the disk array system for proper ventilation ambient temperature of 5 C to 40 C (40 F to 104 F) ambient non-condensing relative humidity of 20% to 80% dust, smoke, and oil free environment no large magnetic fields, such as those generated by a high voltage power cables and motors, etc. no direct sunlight a flat, stable surface capable of supporting the disk array system VT100 Terminal Settings Refer to the following table for a summary of VT100 terminal settings required to communicate with the disk array system. Refer to your system manual for instructions on setting up the VT100 terminal settings. Item Required Setting Connection Serial Port (COM1 or COM2) Protocol RS232 (Asynchronous) Cabling Null Modem cable Baud Rate 115200 Data Bits 8 Stop Bit 1 Parity None 1

easyraid Q24P2-U4R4 Serial ATA II Disk Array System Host Interface 1 System Requirements The disk array system has dual SCSI interfaces. Refer to the following sections to understand host interface system requirements. Small Computer Systems Interface The easyraid Q24P2-U4R4 has dual U320 SCSI interfaces that are compatible with previous SCSI standards. Refer to the following table to understand SCSI bus requirements. Note Subtract the internal cable length (30 cm) from the maximum SCSI bus length to calculate the maximum external SCSI cable length. SCSI Standard Maximum SCSI Bus Length in Meters Data Rate in Megabytes per Second Maximum Number of Devices Ultra320 12 320 15 Ultra160 12 160 15 Ultra2 12 80 15 Ultra Wide 1.5 40 7 Fast Wide 3 20 15 Ultra 1.5 20 7 2

Power P/S Fail A ce s Enter ESC Pri/Sec Power P/S Fail Access Enter ESC Disk Array System Power P/S Fail A ce s Enter ESC Pri/Sec Disk Array System 2 Basic Configuration This chapter describes disk array system connections and disk installation. Unpacking Contact your supplier if any of the following items are missing or damaged. Caution The disk array system is heavy. Be careful when lifting and moving it. Item Disk Array System qty 1 pcs Hard Disk Tray 24 pcs Hardware and Software User Manuals 1 set easyraid Q24P2-U4R4 Ultra320 SCSI to Serial ATA Hardware User Manual easyraid Q24P2-U4R4 Ultra320 SCSI to Serial ATA Software User Manual Rails 1 set Rail Extenders 1 set 3

easyraid Q24P2-U4R4 Serial ATA II Disk Array System VHDC to VHDC Ultra320 SCSI Cable 1 pcs 2 Basic Configuration Unpacking HPD to VHDC Ultra320 SCSI Cable Terminator VHDC Front Panel Keys 1 pcs 1 pcs 2 pcs Power Cables 3 pcs Screw pack 2 pack Fix Screw pack M5 2 pack Fix Scwer pack M6 2 pack Fix Scwer pack UNC #10-32 2 pack RS-232 cable 1 pcs CD-ROM (option) 1 pcs 4

Components easyraid Q24P2-U4R4 Serial ATA II Disk Array System Closed Front Panel 2 3 4 9 2 Basic Configuration Components Power P/S Fail Access Enter ESC 1 5 6 7 8 No. Name Description 1 LCD panel Displays warning, operating, and configuration information. 2 Power-on indicator Indicates the disk array system power is on. 3 Power supply fail indicator Indicates a failed power supply. 4 Host computer access indicator Indicates data transfer between the disk array system and the host computer. 5 Up function button Moves up in the LCD menus. 6 Down function button Moves down in the LCD menus. 7 Enter function button Selects a menu item or confirms a choice or entry. 8 Escape function button Returns to the previous LCD menu without making changes. 9 Lock Locks front cover. 5

Disk Mapping Tray LED Indication Color Status Bule Access Green Disk Online Red No Disk easyraid Q24P2-U4R4 Serial ATA II Disk Array System Open Front Panel 2 4 6 8 10 12 14 16 18 20 22 24 2 Basic Configuration Components 1 3 5 7 9 11 13 15 17 19 21 23 25 No Name Description 1-24 Disk trays 1-24 Removable hot swap disk trays 25 Front panel door Protects the disks and houses the LCD panel 6

easyraid Q24P2-U4R4 Serial ATA II Disk Array System Disk Tray 2 Basic Configuration Components Front 2 1 3 No. Name Description 1 Power/Error indicator LED Different colors indicate different disk states: Green Disk online Orange Disk full Red No disk 2 Access indicator LED This blue LED indicates that the disk is being accessed. 3 Tray handle Releases the disk tray. 7

easyraid Q24P2-U4R4 Serial ATA II Disk Array System Rear View 1 2 3 4 5 6 7 8 2 Basic Configuration Components 19 Fan 1 Fan 3 Fan 4 Fan 2 LAN Host Port 2 Host Port 1 COM P/S 1 P/S 3 P/S 2 18 17 16 15 14 13 12 11 10 9 No. Name Description 1 Cooling fan 1 System cooling fan. 2 Ethernet Port Used for browser-based configuration. 3 Host Port 2 (Secondary SCSI channel) Connects to the host server. 4 Cooling fan 3 System cooling fan. 5 Host Port 1 (Primary SCSI channel) Connects to the host server. 6 RS-232 Port Connects to a VT100 terminal or equivalent. 7 Cooling fan 4 System cooling fan. 8 Cooling fan 2 System cooling fan. 9 Power Supply Handle For power supply removal. 10 Power Supply 2 Removable redundant power supply 2. 11 Power Supply AC In Connects to a 100-240 VAC power source. 12 UPS port Data port for uninterruptable power supply. 13 Power Supply Handle For power supply removal. 14 Power Supply 3 Removable redundant power supply 1. 15 Power Supply AC In Connects to a 100-240 VAC power source. 16 Power Supply Switch Switches the power on or off. 17 Power Supply Handle For power supply removal. 18 Power Supply 1 Removable redundant power supply 1. 19 Power Supply AC In Connects to a 100-240 VAC power source. 8

Disk Mapping Tray LED Indication Color Status Bule Access Green Disk Online Red No Disk Installing Disks This section describes how to install disks in the disk array system. easyraid Q24P2-U4R4 Serial ATA II Disk Array System 1 Unlock the front panel door, then pull it open. 2 Push the button (A) to release the disk tray handle. Pull the handle (B) to release the tray. 2 Basic Configuration Installing Disks A B 3 Align the rear of the disk with the rear of the disk tray. 4 Insert the disk into the disk tray and fix into place with screws supplied with the disk. 9

Disk Mapping Tray LED Indication Color Status Bule Access Green Disk Online Red No Disk easyraid Q24P2-U4R4 Serial ATA II Disk Array System 5 Slide the disk tray back into the empty slot (A), then slowly close the disk tray handle (B). 2 Basic Configuration Installing Disks A B 6 Repeat steps 2 to 5 until all of the required disks have been installed. 7 Push the front panel door closed, and lock it. 10

Fan 3 LAN COM Host Port 2 Host Port 1 Fan 1 Fan 3 Fan 4 Fan 2 LAN COM Host Port 2 Host Port 1 I I Fan 4 Making Connections easyraid Q24P2-U4R4 Serial ATA II Disk Array System After the required number of disks have been installed, external connections to the disk array system must be made. This section describes how to make all of the necessary connections. Connecting the Host Interface The disk array system has dual SCSI interfaces. Refer to the following sections to make host interface connections. Small Computer Systems Interface The easyraid Q24P2-U4R4 has dual Ultra320 SCSI interfaces. Follow these instructions to make connections. 1 Connect the SCSI terminator (A) to the right top connector of the easyraid Q24P2- U4R4 host port 1 (primary SCSI channel) at the rear of the disk array system. Fan 1 Fan 2 2 Basic Configuration Making Connections P/S 1 P/S 3 P/S 2 A P/S 1 P/S 3 P/S 2 B 2 Connect the Ultra320 SCSI cable (B) to the right bottom connector of the easyraid Q24P2-U4R4 host port 1 (primary SCSI channel) at the rear of the disk array system. 11

LAN COM Host Port 2 Host Port 1 easyraid Q24P2-U4R4 Serial ATA II Disk Array System Connecting a network Connect the network cable to the RJ-45 port at the rear of the unit. 2 Basic Configuration Making Connections Fan 1 Fan 3 Fan 4 Fan 2 LAN COM Host Port 2 Host Port 1 P/S 1 P/S 3 I Connecting and Turning on the Power P/S 2 1 Plug a power cable (A) to a power connector at the rear of the unit, then plug the second power supply cable into the second power connector (B) and the third power supply cable into the third power connector (C). Note The system is equipped with auto switching power supplies that can run on 100 to 240 VAC. Fan 1 Fan 3 Fan 4 Fan 2 P/S 1 P/S 3 I P/S 2 A C B 2 Switch on both power supplies. 12

Power P/S Fail Access Enter ESC Mounting in a Rack easyraid Q24P2-U4R4 Serial ATA II Disk Array System When the disk array system is completely set up, it can be installed in a standard 19-inch rack. Follow the instructions in this section to install the disk array system in a rack. 1 Clip eight rack nuts supplied with your rack, into the rack, taking care that they correspond with the mounting points on the rails. 2 Extend both of the rails so that they are the right length to fit in your rack. 3 Bolt the rails into the rack using the rack bolts supplied with your rack. You will need four nuts and bolts (not included) for each rail; two at the front and two at the back. 4 Tighten the locking screws when they are the correct length. 5 Slide the disk array system into the rack and bolt it into place with the supplied fixing screws. 2 Basic Configuration Mounting in a Rack Caution This product is heavy. Attempting to install the disk array system in a rack by yourself could result in injury or damage to the product. 13

Power P/S Fail Access Enter ESC easyraid Q24P2-U4R4 Serial ATA II Disk Array System Installing the Rail Extenders Follow these instructions to fit the rail extenders if required. 2 Basic Configuration Mounting in a Rack 1 If required, bolt the rail extenders into place as shown using the small bolts provided. 2 Slide the disk array system into the rack and bolt it into place with the supplied fixing screws. Note The rail extenders may be required to allow the disk array system room for the front door to open correctly. 14

3 Maintenance Replacing a Disk A disk failure is indicated when the Power/Error LED at the front of the drive tray turns red and the audible alert sounds. Note Turn off the audible alert by pressing the Up and Down function buttons on the front panel twice simultaneously. The LCD panel displays the failure with the symbol R or W. R indicates a disk failure or error, and W indicates that there are too many bad sectors on the disk. Example: 111111111112 Disks 1 to 11 are members of array group 1. Disks 12 to 22 are members of array group 2. Disk 23 has too many bad sectors. Disk 24 has an error or a fault. 2222222222WR Disks are hot swappable, which means that they can be inserted and removed while the disk array system is powered on and operating. Follow these instructions to replace a failed disk. 1 Unlock the front panel door, then pull it open. 2 Pull the tray handle away from the disk tray to release it; and pull the disk tray out. 3 Remove the screws from the failed disk, then remove the disk from the disk tray. 4 Align the rear of the new disk with the rear of the disk tray. 5 Insert the new disk into the disk tray. Note The new disk must have the same or a greater capacity than the faulty disk that was removed. If the disk capacity is smaller, the audible alert sounds and the auto-rebuild operation doesn t start. For best performance, it is recommended that the new disk be identical to the failed disk. 6 Attach the disk to the disk tray with the screws that came with the disk. 7 Slide the disk tray back into the empty slot, then close the disk tray handle. 8 Push the front panel door closed, and lock it. 15

3 Maintenance Replacing a Power Supply easyraid Q24P2-U4R4 Serial ATA II Disk Array System Replacing a Power Supply The disk array system is equipped with a Power Supply Fail Indicator LED at the front of the unit that turns red when one of the power supplies fails. The message Power x failure also appears on the LCD panel, where x refers to power supply 1, 2 or 3, and an audible alert sounds. Note Turn off the audible alert by pressing the Up and Down function buttons on the front panel twice simultaneously. Power supplies are hot swappable, which means that they can be inserted and removed while the disk array is powered on and operating. Follow these instructions to replace a failed power supply. 1 Identify the power supply that has failed. Fan 1 Fan 3 Fan 4 Fan 2 LAN Host Port 2 Host Port 1 COM P/S 1 P/S 3 P/S 2 Power Supply 1 Power Supply 3 Power Supply 2 2 Remove the power cable from the power supply connector at the rear of the unit. Note The system is equipped with auto switching power supplies that can run on 100 to 240 VAC. 16

I I LAN COM Host Port 2 Host Port 1 I easyraid Q24P2-U4R4 Serial ATA II Disk Array System 3 Loosen the power supply retaining screw. Fan 1 Fan 3 Fan 4 Fan 2 LAN COM Host Port 2 Host Port 1 P/S 1 P/S 3 4 Pull the power supply handle out. Fan 1 Fan 3 Fan 4 Fan 2 LAN COM Host Port 2 Host Port 1 P/S 2 Power Supply retaining screw 3 Maintenance Replacing a Power Supply P/S 1 P/S 3 P/S 2 5 Remove the faulty power supply by pulling the power supply handle A and pressing the release catch B at the same time. Fan 1 Fan 3 Fan 4 Fan 2 B P/S 1 P/S 3 P/S 2 Release catch A 17

I easyraid Q24P2-U4R4 Serial ATA II Disk Array System 6 Insert a new power supply. Fan 1 Fan 3 Fan 4 Fan 2 3 Maintenance Replacing a Power Supply LAN COM Host Port 2 Host Port 1 P/S 1 P/S 3 7 Push the power supply handle into place. 8 Tighten the power supply thumbscrew. Fan 1 Fan 3 Fan 4 Fan 2 LAN COM Host Port 2 Host Port 1 P/S 2 P/S 1 P/S 3 I P/S 2 9 Reconnect the power cable. 18

I I Upgrading Memory easyraid Q24P2-U4R4 Serial ATA II Disk Array System The disk array system takes a single DDR-333 DIMM with a maximum capacity of 2 GB. Follow these instructions to upgrade the memory. 1 Loosen the screws holding the controller cage in place. 2 Slide the controller-cage out of the chassis. Fan 1 Fan 3 Fan 4 Fan 2 LAN COM Host Port 2 Host Port 1 P/S 1 P/S 3 P/S 2 3 Maintenance Upgrading Memory Fan 1 Fan 3 Fan 4 Fan 2 LAN COM Host Port 2 Host Port 1 LAN COM Host Port 2 Host Port 1 P/S 1 P/S 3 P/S 2 3 Pull the DIMM retaining clips away from the DIMM; the DIMM springs out of the socket. Remove the DIMM. 19

Fan 1 Fan 3 Fan 4 Fan 2 I Fan 1 Fan 3 Fan 4 Fan 2 LAN COM Host Port 2 Host Port 1 I easyraid Q24P2-U4R4 Serial ATA II Disk Array System 4 Gently push the new DIMM into the socket, then push the corners of the DIMM down. The DIMM is secured by the DIMM retaining clips. 3 Maintenance Upgrading Memory Note The DIMM module will fit in only one direction. Do not force the DIMM into place. 5 Push the controller cage back in, lower the handle, and tighten the retaining screws. LAN COM Host Port 2 Host Port 1 LAN COM Host Port 2 Host Port 1 P/S 1 P/S 3 P/S 2 P/S 1 P/S 3 P/S 2 20

Appendix Hardware Specifications Item Specification Host Interface SCSI Ultra 320 Disk Interface Dimensions Weight RAID Functions Disk Array Functions Connectors Power Supply Warranty Safety SATA II, 3.0 Gb/s 176 mm (H) x 485 mm (W) x 565 mm (D) 34 Kg without disks Raid levels: JBOD, 0, 1, 3, 5, 6, 10, 30, 50, 60, NRAID Hot spare support Disk hot swapping with automatic online rebuilding Multiple RAID (max. 8) O/S independent and transparent 512 MB ~ 2 GB DDR II SDRAM LCD panel operation indicator Audible alarm/disable alarm LED indicator on disk failures 4 x Ultra320 SCSI ports (2 channels) 1 x RS-232 Serial port (115200, 8, N, 1) 1 x RJ-45 Ethernet port (10/100 Mbps) Redundant 2 + 1, 350 Watt 100-240 VAC, 47-63 Hz, 8~4A +/- 10% Over voltage, current, power, and short circuit protection LED indicates power status Operating temperature: 5 C ~ 40 C Output: +5V, +3.3V, +12V 3 year warranty UL, CE and FCC Class B 21