MODULAR CIRCUIT MONITORING SYSTEM

Similar documents
AcquiSuite Ally 48 Advanced Branch Circuit Monitor

Technical data sheet. PowerLogic power-monitoring units EM3500 series DIN Rail meter

AcquiSuite Ally 12 & 48 Advanced Multi-Circuit Meter

PowerLogic BCPM Functions and characteristics

MIC-2 MKII, Multi-instrument DATA SHEET

EM-1000 /EM-2000/ EM-3000 Series Multifunction Power and Energy Meters

SECTION ( ) LIGHTING CONTROL PANELBOARD

EM132 EM132. Main Features. Multi-functional 3-Phase Transducer. Energy Meter

QUICK SETUP GUIDE PMC-1000, PMC-1001, PMM-1000, PMB PM Series Power Meter. Safety Information. Equipment Maintenance and Service.

Power Xpert Branch Circuit Monitor

SECTION SWITCHBOARDS

DATA SHEET LAN Server For Energy and Power meters AEM and APM with Modbus interface

DIRIS Digiware D and C Communication and control power interfaces

HYBRID PV INVERTERS HySpirit Series. 4kW-10kW. Hybrid Inverter with Battery Backup Smart Energy for Smart Home

PM Series Power Meter

Multifunction Transducer MT440

Multilin EPM Energy and Demand Submeter with Wi-Fi. Monitoring & Metering. Communications. Key Benefits. Applications

UMG 20CM. 20 Channel Branch Circuit Monitoring Device with RCM

Electrical network management. Schneider Electric. EM4200 Technical Datasheet

Eaton DC Power Solutions

APPLICATION BRIEF. Branch Circuit Monitoring: Power Monitoring and Measurement in Production Facilities. Moving Away From a Break-Fix Model for Power

May Delivers real-time, Web-enabled monitoring of electrical distribution and control equipment

Clarity 3 GCE-8000 EMBEDDED IOT CONTROLLER PRODUCT DATA SHEET

UMG 511. Class A EN UMG 511 Class A power quality analyzer. according to EN50160, IEEE 519, ITIC, IEC Areas of application

Networks TN, TT, IT networks 3 and 4-phase networks Up to 4 single-phase networks

FLEXIBLE INTELLIGENT RACK POWER DISTRIBUTION. Contact. About Anord Mardix.

Modbus Server - M-Bus (EN ) Gateway for the integration of M-BUS meters with Modbus RTU and TCP based control systems.

ProData data logger. Ethernet. Pulse inputs and Pulse outputs. Thermistor input. Modbus-Ethernet gateway. Memory 32 MB. Threshold value monitoring

POWER PATROL SAVE MONEY - SAVE TIME - SIMPLIFY YOUR JOB. what s inside?

Overview. Applications. Features

H704-42(H)(E), H704-42/1(H)(E)

ACUREV 2000 Multi-Circuits Networked Multifunction Power Energy Meter

MIC-2 Multi-instrument DATA SHEET

ENERCEPT H8035/H8036 DANGER NOTICE CAUTION. Networked Power Transducer (Modbus RTU) INSTALLATION GUIDE QUICK INSTALL TABLE OF CONTENTS

Power and accuracy. Versatile. One display can monitor up to 32 measuring modules information

Tesseract. Technical Data sheet

PowerLogic EM4000 series

BFM-II BFM-II BRANCH FEEDER MONITOR. Highlights

APU 200 Automatic DATA SHEET Gen-set Controller DATA SHEET

MIC-2 MKII & MIC-2 MKII DIN, Multi-instrument DATA SHEET

MICROFUSION FEATURES OPTIONS CERTIFICATIONS (PENDING) THREE PHASE SCR POWER CONTROLLERS

MID PRELIMINARY DATA SHEET. RI-D Series. Single Phase Multifunction Energy Meter (MID Certified) MID

PQube 3. Power Quality, Energy & Environment Monitoring. New Low-Cost, High-Precision

DATA SHEET. Advanced Power Meter, APM 380 & APM 305

ProData DATA LOGGER. Chapter 03 ProData data logger. Ethernet. Pulse inputs and Pulse outputs. Modbus-Ethernet gateway. Thermistor input.

The PowerLogic range. Gain energy insight and control

PowerLogic Branch Circuit Power Meter Series. Harness industry-leading monitoring capabilities for maximum power reliability

DTS 310. DIN Rail Mounted, Indoor Rated Revenue Grade Electrical Sub-meter. Page 1. Measurlogic MQ A

PM174 PM174 IEEE1159 ADVANCED POWER QUALITY ANALYZER. Features

Monitoring Made Easy. October 2015 APRIL 2015

DKG-210 UNIVERSAL INTERNET GATEWAY UNIT

Electronic Submeter with Advanced WiFi Ethernet Capability

Billion SG3015. Compact ZigBee Power Meter Series. Fully complied with IEEE

ACUREV Three-Phased DIN-Rail Multifunction Meter FEATURES

with Backlight Graphic LCD Screen

UMG 20CM. UMG 20CM 20 Channel Branch Circuit Monitoring Device with RCM. Harmonics via analysis channel RCM. Alarm management.

DIRIS A-30 Multifunction power metering & monitoring device - PMD

controller data sheet JACE 8000 PRODUCT DEFINITION

UMG 604. UMG 604 Power analyser. Modbus master, Ethernet gateway. Harmonics. Memory 128 MByte. Homepage. Graphic programming.

EPM g Energy. Multilin BUILDING AUTOMATION POWER METER. BACnet /IP Communications and Energy Measurement KEY BENEFITS APPLICATIONS FEATURES

U niversal Measuring Device UMG 96 S. Little Fieldbus Giant. Modbus / Profibus. Harmonics. Memory. Analogue outputs. Digital I/O

AcuRev Multi-Circuit Power and Energy Meter. Shop for Accuenergy products online at:

DIRIS Digiware Measurement and monitoring system for electrical installations

Digital Multifunction Meters. Digital Multifunction Meters

BCM2 Series Branch Circuit Monitors Quick Setup Guide

DATA SHEET. Advanced Energy Meter, AEM 380 & AEM 305

PQM - Power Quality Monitoring

Innovative. Engineering. Power. structure source. Making the complex, simple. Structure Source PDU s

DIRIS Digiware Measurement and monitoring system for electrical installations multi-circuit plug & play

IntesisBox Modbus Server - BACnet/IP Client

Power Xpert Meter 350 (PXM350) three-phased DIN-rail multifunction meter

24973 Circuit Breaker MINIATURE CIRCUIT BREAKER, 440VAC, 10A, CIRCUIT BREAKER TYPE: STANDARD

EM133 EM133 TOU SMART ENERGY METER. Main Features. Multifunctional 3-Phase Smart Meter. Billing/TOU Energy Meter

PQube 3. Power Quality, Energy & Environment Monitoring. New Low-Cost, High-Precision

User Manual V2.6. SDM120-Modbus. Single-Phase Multifunction DIN rail Meter

PRODUCT & SYSTEM OFFERINGS

Three-phase electricity meter with instantaneous reading of electrical variables. Input current measurement: 5 A, 90 A, 150 A, 250 A (span by model).

QUICK SETUP GUIDE. BCM2 Series Branch Circuit Monitors. Safety Information. Equipment Maintenance and Service. Raritan DANGER!

IIM Warwick Court. Williamsburg VA REV 5

User Manual V1.1. SDM120-Modbus(mV) Single-Phase Multifunction DIN rail Meter

PowerCube by Onyx Power

Integrated Multipoint Submetering

UMG 96RM. UMG 96RM Universal measurement instrument. Areas of application

WM20. Power analyzer for three-phase systems. Benefits. Description

Energy Management Energy Transducer Type ET112

PDI Modular Compact Remote Power Panel

IntesisBox Modbus Server Panasonic

for M-Bus, Modbus and 1-Wire devices

PowerPak 2 Power Distribution Unit. Flexible. Configurable. Intelligent. Safe.

NEW ERA METER. Installation & Operation Guide NE METER

PEAK TM. PEAK TM controllers. Mid-Market BAS Smart equipment controllers. HVAC/R controllers

Smart Energy & Power Quality Solutions. ProData datalogger. Datalogger and Gateway

Product Catalog. Belgium Tel.: +32 (0) The Netherlands Tel.: +31 (0)

Simple Electrical Utility Cost Allocation Solutions

9.3. Metering Devices, Protective Relays, Software and Connectivity

MW/MVAR Transducer Specifications

QUICK SETUP GUIDE PMC-1000, PMC-1001, PMM-1000, PMB-1960, PMMC-1000 PM Series Power Meter

INTEGRATED SYSTEMS AND CONTROL, INC. User s Hardware Manual. PCMNET V 7. xx

SDM120C. Single-Phase Energy Meters. RS485 Modbus RTU. User Manual V1.0

Smart Energy & Power Quality Solutions. UMG 96S Universal flush-mounting measuring instrument

Transcription:

MODULAR CIRCUIT MONITORING SYSTEM Contact Anord Mardix (USA) Inc. 3930 Technology Court Sandston, VA 23150 Email: us.sales@anordmardix.com Call: +1 800 228 4689 www.linkedin.com/company/anordmardix www.twitter.com/anordmardix About Anord Mardix Anord Mardix is a leading provider of power distribution and protection equipment to the global market. We are a vendor of choice to many of the world s leading data center and cloud computing industries. We produce the most comprehensive product range in the market - from power, control, and monitoring solutions to our unique service capability. Our ability to customize and produce on a large scale delivers the most reliable end-to-end power systems to all our customers, from independent providers to hyper-scale leaders. RAPID INSTALLATION EASILY ACCESSED DATA EASY CONNECTIVITY INTELLIGENT FEATURES HIGH ACCURACY

Energy Monitoring Revolutionized The Anord Mardix Core Module TM System The Anord Mardix Modular Circuit Monitoring System is redefining circuit monitoring with next generation technology that simplifies installation and connectivity while providing instant access to data in a user-friendly format. The versatile Core Module system is a single monitoring solution with peripherals optimized for branch circuit and multi-circuit monitoring applications designed to reduce the cost and complexity associated with legacy systems. Features The versatile and compact Core Module functions as a gateway that can host up to four interface modules monitoring a total of 96 circuits. Interface modules connect via Ethernet cables and are available for new and retrofit branch circuit and multi-circuit applications. Interface Modules Connect up to four x 24 circuit Interface Modules using Ethernet Cables. Voltage Input Cell / GPS Antenna Ethernet Ports Direct access to real time and logged data using any web browser Rapid Installation Optimized for new and retrofit installations with no disruption to critical loads Monitors up to 96 circuits Options for solid core, split core CTs, Rogowski coils 1, and analog, discrete and pulse inputs Easily Access Data On-board web server provides immediate access to real-time and logged data Integrated data logging supports up to 64 GB storage; remotely accessible or manually exportable Available cloud monitoring service Customizable alarming features Intelligent Features Presence of voltage detection accurately indicates breaker status even under no load conditions Predictive Circuit Health Algorithm (patent pending) detects changes in circuit performance to predict potential failures True-Circuit Display mapping function presents data according to actual circuit configurations Detailed power and energy monitoring per circuit including Waveform capture and THD High Accuracy True 0.5% accuracy suitable for billing applications Interface Modules Digital I/O Ports Serial Port USB / SD Card Interface Host SD Card for local data storage Native Modbus TCP/IP and other Ethernet protocols Dual Ethernet ports simplify networking multiple Core Modules Solid Core Panel CT Strip Split Core Panelboard Module Multi-Circuit CT Module Easy Connectivity Select from multiple connectivity options including Modbus TCP/IP, RTU, BACnet, WiFi and cellular Open protocols allows connection with any third party monitoring system 3 x auxiliary CT inputs per strip 18-21 x 100 A x 10 mm high accuracy CTs per strip 3 x auxiliary CT inputs per strip Split core CT ports (x 24) Split core CT w/ connector RJ45 Port Solid Core CT Split Core CT RJ45 Port 24 Universal CT Inputs Rogowski Coil RJ45 Port to Core Module Used for new installations on panelboard branch circuit monitoring Up to 21 circuits per strip + 3 auxiliary CT inputs (96 total) 2 0.75 and 18mm C-C versions 10mm CT window w/ 100 A range Optional presence of voltage sensing for breaker status per circuit Used for retrofit installations on panelboard branch circuit monitoring Floating CT interface strip with quick connect 10mm split core CTs sits on top of existing conductors 24 circuits per module (96 Total) Optional presence of voltage sensing for breaker status per circuit 24 CTs / circuits per module (96 Total) Supports 0.33 V solid core and split core CTs as well as available native Rogowski coil version available Optional presence of v or breaker status per circuit 2018 Anord Mardix - Patent Pending CM100 1 Consult Interface Module data sheet for specifications and additional modules 2 Main input readings can be summed or measured directly using direct CT inputs 1 2

Connectivity Solutions Anord Mardix makes it easier than ever to connect and access data with a range of connectivity solutions including low cost CAT1 cellular links. Connectivity Options Data Acquisition Options Data Presentation Modbus TCP/IP and RTU HTML Wi-Fi BACnet Embedded Cellular Web Server On board web server provides access to real time and logged data. Data Stream Open protocols feed data to any third party monitoring system Cloud View and manage data using the optional plug and play cloud application Manual Export Logged data can be manually exported from the core Module Smart Technology That Makes a Big Difference The available cloud monitoring service provides all the functionality of advanced monitoring systems at a fraction of the cost and with no programming. Report Generation Predictive Analysis Trending Alarming Installation Overview Anord Mardix reduces the cost of monitoring by simplifying installation and providing instant access to real time and logged data without programming requirements. 1. Mount the compact Core Module onto DIN rail; fits inside most existing enclosures. 2. Mount CT interface cards in most convenient location to minimize CT cable length and connect to monitor using standard network cables. 3. Connect to network and acquire real time and logged data from the monitor or utilize optional embedded cellular modem for affordable wireless connectivity at a cost lower than most network connections. Product Selection Guide Core Module Monitor Feature Set Multi-Circuit Monitor Interface Cards (24 channel each) Core Module (supports up to 96 circuits) Solid Core Branch Circuit Monitor Presence of Voltage Detection detects circuit breaker status even under no load conditions using a proprietary voltage field detection system identifying failed circuits that may go unnoticed on conventional monitoring systems Predictive Circuit Health Analysis uses proprietary algorithms to analyze circuit signatures over time and detect changes indicative of common failure modes in power supplies and other critical loads Feature Standard Enhanced Local Network Access Integrated Web Server Field Upgradeable Feature Set SD Card and Network Configuration Applications Waveform Capture: High resolution power quality data from all circuits is stored for any power quality deviation providing invaluable data for evaluating power disturbances Colocation Data Centers Colocation data centers often must monitor the health and energy usage of each branch circuit Demand Management Sub-metering identifies energy use by specific loads allowing them to be managed to avoid peak demand charges True Circuit Display allows data to be expressed according to the actual panelboard configuration by indicating pole position, circuit type, friendly names and more to each circuit Lighting / HVAC Energy Optimization Sub-metering is required to provide the needed resolution to initiate and verify most energy efficiency upgrades Tenant Sub-Metering Commercial facilities are increasingly using sub-metering to allocate costs Modbus TCP/IP output Modbus Serial Output Integrated Gateway Presence of Voltage Detection BACnet Protocol Integrated Cellular Modem Support Waveform Capture Predictive Health Algorithm True Circuit Display WiFi Output GPS Time Base Local Data Logging 158.7mm (6.25 ) 59.2 mm (2.33 ) Switchgear / Power Distribution Economically identify energy and power use per breaker Circuit / Load Health Facilities use sub-metering to verify performance of critical loads SD Card Data Storage Network Data File Export Alarming 3 Energy Use Allocation Larger buildings and campuses require a means of allocating energy usage for costing purposes High-End Residential High end residential automation systems can utilize branch circuit sub-metering to enhance reliability and efficiency Pulse Input Native Rogowski Coil Input Thermal Monitoring per Circuit Monitors are available with a Standard and Enhanced feature set. 4

Product Selection Guide See product selection guide online for complete product offering and detailed ordering instructions. Core Module TM Monitoring Systems CM01 CM02 Standard Core Module TM monitoring system; expandable up to 96 channels Enhanced Core Module TM monitoring with enhanced firmware; expandable up to 96 channels Solid Core CT Strip Monitoring System for Installations on New Panelboards - All systems include 10mm x 100 A solid core CTs and + 3 auxiliary CT terminals per strip for main input CTs 0.75" c-c CT strips (21 CTs + 3 auxillary CT inputs per strip) and Core Module Monitor ibcm0a42a1 ibcm0b42a1 ibcm0a84a1 ibcm0b84a1 42 pole system with 2 x 21 x 100 A solid core CT strips with 0.75 C-C spacing 42 pole system with 2 x 21 x 100 A solid core CT strips with 0.75 C-C spacing; includes presence of voltage detection 84 pole (2 panel) system with 4 x 21 x 100 A solid core CT strips with 0.75 C-C spacing 84 pole (2 panel) system with 4 x 21 x 100 A solid core CT strips with 0.75 C-C spacing; includes presence of voltage detection 18mm c-c CT Strips (18 CTs + 3 auxiliary CT inputs per strip) and Core Module TM Monitor ibcm2a42a1 ibcm2b42a1 ibcm2a84a1 ibcm2b84a1 36 pole system with 2 x 18 x 100 A solid core CT strips with 0.75 C-C spacing 36 pole system with 2 x 18 x 100 A solid core CT strips with 0.75 C-C spacing; includes presence of voltage detection 72 pole system with 4 x 18 x 100 A solid core CT strips with 0.75 C-C spacing 72 pole system with 4 x 18 x 100 A solid core CT strips with 0.75 C-C spacing; includes presence of voltage detection Retrofit Panelboard CT Interface Module (Floating Strip CT Interface Module) and Core Module TM Monitor Floating Strip CT interface boards reside in raceway and interface with 10mm x 75 A or 100 A split core CTs using plug-in quick connects. Each Core Module TM accommodates up to four interface modules (96 circuits) ibcm3c24a1 ibcm3c48a1 ibcm3a72a1 ibcm3c42a1 icts324c 24 channel split core CT monitoring system with 24 split core CTs 48 channel split core CT monitoring system with 48 split core CTs 72 channel split core CT monitoring system with 72 split core CTs + 12 aux. CT inputs 96 channel split core CT monitoring system with 96 split core CTs 4 channel expansion Panelboard CT Interface Module ; Core ModulesTM can accommodate up to 4 x 24 modules 5 6

Product Selection Guide Multi-Circuit Monitoring Systems and Core Module TM Monitor The Multi-Circuit Monitoring system supports up to 4 x 24 CT Interface Cards (96 circuits) and accommodates any 0.33 Volt current transformers or native Rogowski coils. All imcm systems include the Core Module as well as CT Interface Card specified. imcm0a061 imcm0a121 imcm0a241 imcm0a481 imcm0a721 imcm0a961 ictc24a1 6 Channel Multi-Circuit Monitoring System (single CT Interface Card) 12 Channel Multi-Circuit Monitoring System (single CT Interface Card) 24 Channel Multi-Circuit Monitoring System (single CT Interface Card) 48 Channel Multi-Circuit Monitoring System (two CT Interface Cards) 72 Channel Multi-Circuit Monitoring System (three CT Interface Cards) 96 Channel Multi-Circuit Monitoring System (four CT Interface Cards) 24 Channel Expansion Card (each Core Module can accommodate up to four x 24 channel cards) Wireless Communication Connectivity Options immcc Embedded CATM1 cellular modem; must specify region; connectivity plans purchased separately Current Transformers and Rogowski Coils See Current Transformer selection guide for details 7 8

Technical Specification Inputs Input power (standard) 90-277 VAC (480 VAC 4W+G) 50/ 60 Hz Input power (enhanced) 480-600 VAC (3W or 4W+G) 50/ 60 Hz Voltage connection terminals 22-14 AWG Overload protection Internally fused Power consumption <5W / 0.1 A @ 240 VAC Channels / circuit capacity 24 x 4 channels (96 circuits total) Performance Accuracy 0.50% Sampling rate > 3 khz Communications Data protocols Modbus TCP/IP (Ethernet), Modbus RTU (RS-485 2 wire), HTML (web server) Modbus serial specifications 9600, 19200, 38400 Baud (selectable) Ethernet ports 2 x RJ-45 10/100 Mbit USB port USB 2.0 Type A Web server HTML via standard browser WiFi option 802.11 g/n ; requires WiFi option Cellular option CAT 1 / CAT M1; requires subscription Environmental Operating temperature 0 to 60 C (32 to 140 F) (<95% RH non-condensing) Storage temperature -40 to 70 C (-40 to 158 F) Enclosure versions NEMA 1/IP20 (indoor use); NEMA 4 / IP67 (outdoor use) Approvals Agency approvals UL Listed to EN61010-1, Cat. III, pollution degree 2, CE Technical Specification Monitored Parameters Monitored Parameter Per Circuit Total Load 1 Current per phase Max. current per phase Avg. Current per phase Current demand per phase Max. current demand per phase Current phase angle Voltage phase angle Real power (kw) per phase Real power (kw) demand per phase Real power (kw) demand max Energy (kwh) per phase Power factor Power factor vector Apparent power (kva) Reactive power (kva) THDI THDV Voltage, L-L and average Voltage, L-N and average Voltage, L-N and per phase Waveform capture Circuit Health 3 Presence of Voltage 3 Ground current 2 1 Total load data can be calculated by summing up branch CT measurements or directly measured using CTs 2 Required optional ground current CT connected to auxiliary CT input 3 Optional feature 9 10