EPWR Series. RoHS. Product Description. Available Products. Installation Instructions 01

Similar documents
TPE 1464 Series Pressure Transducer

Differential Liquid/Gas Pressure Transmitter

HWS Series Wall Mount with Relay Setpoints, LCD, and Humidistat Control

Zone Pressure Touch Sensor - Standard Range

Zone Pressure Touch (ZPT) Sensor with Attached Tube (-AT) - Low Pressure Range Unit Installation and Operation Instructions

HT Series Wall Mount with Analog Setpoints, LCD, and Humidistat and Thermostat Control

Zone Pressure Touch (ZPT) Sensor - Standard Range

HT Series Wall Mount with Relay Setpoints, LCD, and Humidistat and Thermostat Control

M5100 Heavy Industrial Pressure Transducer

DP DP2500 DP0250

P30-2. Overview. Pressure Transmitter Datasheet. *High Quality* 3 Years Warranty. At a Glance. Function. Application

Installation and Maintenance Instructions for GC55 Differential Pressure Transducer Version 1.0 5/11

CDD Carbon Dioxide Transmitter

LAUREL. Laureate Digital Panel Meter for Load Cell & Microvolt Input ELECTRONICS, INC. Features. Description

Manual of Electrical Installation for Pressure Probes KS and KS-SIL2 series

CDD4 Series Room CO2 Transmitter Installation Instructions

Product Data. Model 675 Shark Cage Submersible Level Transmitter ELECTRONIC PRESSURE MEASUREMENT PRODUCTS DESCRIPTION FEATURES APPLICATIONS

LAUREL. Laureate Digital Panel Meter for Process and Ratiometric Signals ELECTRONICS, INC. Features. Description

DWYER INSTRUMENTS, INC. Series AVUL Air Velocity Transmitter. Specifications - Installation and Operating Instructions.

XMLR400M1P25 Pressure sensors XMLR 400bar - G 1/4-24VDC ma - PNP - M12

Model 675 DREXELBROOK. Shark Cage Submersible Level Transmitter DATA SHEET. Description. Features. Applications.

PS-AULDP Series. Overview. Applications. Features & Benefits. Datasheet. Ultra Low Air Differential Pressure Transmitters

Table of Contents. General Information. Document Sure-Aire Flow Monitoring System. User and Service Manual WARNING CAUTION

CONTROL MICROSYSTEMS Analog Output Module. Hardware Manual

CDD4 Duct Carbon Dioxide Transmitter

CONTROL MICROSYSTEMS Analog Input Module. Hardware Manual

Inductive Cylinder Position Sensors

MODEL 8000MP LEVEL SENSOR

TRANSMITTERS. HygroFlex & HygroClip-EX. Applications. Highlights

Alicat Scientific Operating Bulletin. Alicat Scientific P and PC Series Pressure Gauge and Controller FLOW. Tare PSIG.

Schneider Electric s SCD series of duct mount sensors measure the levels of CO 2. , RH (if equipped) and temperature of air inside a duct.

LAKEWOOD INSTRUMENTS MODEL 1575e WATER TREATMENT CONTROLLER

MTII4200 Level Transmitter Installation, Operation & Maintenance Instructions

PRESSURE TRANSMITTER

14 Pressure Measurement. Measuring Devices Description Pressure range Connection Device Page

Operating instructions Electronic pressure sensor. PM205x /01 09/2011

Temperature Switches

The PM1000 series is a universal 4 digit LED plug-on display for transmitters with 4-20mA 2 wire output and fitted with DIN43650 connector.

2 Table of Contents 1. TABLE OF CONTENTS. 1. Table of Contents Introduction Wiring Diagram Terminals Review...

JT400 Multivariable Transmitter

SCADAPack Modbus multivariable transmitter

MPS-32. Pressure Sensors MPS-32 2-Color Panel Mount. Features. Green Display. MPS-32 Programming Options

Thermometer / Barometer System

KOBOLD TDA Series Digital Temperature Transmitter

KOBOLD PDA Series Digital Pressure Transmitter

MELT PRESSURE TRANSMITTERS IE SERIES WITH CURRENT OUTPUT AND PLc VERSION

DP2500 DP0250. Differential Pressure Transmitter. Product Bulletin

Operating Instructions Differential Pressure Transducer PS27

Tempco Instruction Manual

Carbon Monoxide (CO) Gas Detection and Control System

1. Installation. 2. Configuration - Operation. 3. Specifications. Safety

DIFFERENTIAL PRESSURE TRANSMITTER with MODBUS interface Optional Input module

LAUREL ELECTRONICS, INC.

Modular pressure transmitters for harsh environments DST P500, DST P507 and DST P550

Voltage Output IMPACT MELT PRESSURE TRANSMITTERS IN SERIES TECHNICAL SPECIFICATIONS

Electronic pressure switch with display Model PSD-4

PLEASE READ INSTRUCTIONS CAREFULLY BEFORE INSTALLATION!

Differential Pressure Sensor

4-20mA SERIES Single or Dual Axis MEMS Inclinometer

HIGH ACCURACY PRESSURE TRANSDUCERS

M7100 Pressure Transducer

Installation Instructions Temperature transmitter TAA /00 06/2011

Echotouch, EchoSpan & EchoSwitch Ultrasonic Liquid

larger, brighter display for ease of use

C-Flow Coriolis Mass Flow Meter

MST2000 Loop Powered Multivariable SMARTFLOW Transmitter

Installation and Maintenance Instructions for GC31 Ultra-Compact Digital Pressure Sensor

SHPFI Smart Frequency to Current Converter & Pulse Scaler Installation and Operating Instructions

Model HU-224/225. Technical Information TI.224/ Humidity Transduce r FOR ADDITIONAL INFORMATION SEE HU-224/225 DATA SHEET

Pump-Down Controller MODEL mA Input Scalable 4-20mA Output Duplex Pump Alternation Hand-Off-Auto Controls Dual Run-time Meters

TC Type Range Conformity Error. J -210 C to +760 C (-347 F to F) ±0.09 C (±0.16 F) K -244 C to C (-408 F to F) ±0.1 C (±0.

Level-Lance Model 5400A

Operating instructions Pressure sensor. PN50xx / / 2010

OZONE SWITCH Model OS-6. OS-6 Features

Model 206 Operating Instructions. Setra Systems, Inc. 159 Swanson Road, Boxborough, MA

Voltage Output MELT PRESSURE TRANSMITTERS IN SERIES TECHNICAL SPECIFICATIONS

CONTROL MICROSYSTEMS and 5402 Digital I/O Module. Hardware Manual

Energy Management Modular DC Energy analyzer Type VMU-E and VMU-X

WIRELESS SERIES Single or Dual Axis MEMS Inclinometer

Digital Pressure Gauges

MODCELL 2050R Single Loop Controllers

EP/2 Installation Instructions

LAUREL. Laureate RTD Temperature Panel Meter / Controller ELECTRONICS, INC. Features. Description. Specifications

LED55WPG Programmable LED Driver

Trident and Trident X2 Digital Process and Temperature Panel Meter

Output signal active note. Output signal. temperature DC V, DC V DC V, DC V DC V

Pressure transmitter for highest pressure applications Up to 217,500 psi (15,000 bar) Model HP-2

K10 Intrinsically Safe Electro-Pneumatic Positioner Operating Manual

Custom Controller Installation Instructions

MIST Version 2.0 USER S GUIDE. Preliminary Version. INTRODUCTION...2 General Description...2 Models Available...2

TOXALERT MODEL AIR 2000

Suction Pressure Sensor

DCT 531. Industrial Pressure Transmitter with RS485 Modbus RTU. Stainless Steel Sensor

MAXIMA+ Series Rotary Level Indicator

Vibration Switches. For 24/7 Protection of Cooling Towers, Fin Fans, HVAC Systems, Blowers, Motors and Other Critical Machinery

CLEVELAND CONTROLS MODEL 6650 DIGITAL MANOMETER INSTRUCTION MANUAL DM

OIL FILLED MELT PRESSURE TRANSMITTERS. W7 PERFORMANCE LEVEL c SERIES Voltage output

Safety. 2. Configuration - Operation 2.1 RTD Selection 2.2 Driver Test Header. 3. Diagnostics 3.1 ph Input 3.2 Temperature Input

Baltimore Aircoil Company

The IQ300 wall mount load cell indicator is a precision digital indicator for load cell and strain gauge applications.

Transcription:

01 Series RoHS Compliant Product Description The Series remote pressure transducers are designed for differential pressure applications. The sensors are remotely installed on existing plumbing runs. The is available with either armored (6 ft.) or shielded (10 or 20 ft) sensor cables, and it requires a 15 to 30 VDC or 24 VAC power source to generate its output. The is warranted for a period of five years. Available Products Part Number 306-LCD 310-LCD 320-LCD 406-LCD 410-LCD 420-LCD 6-LCD 510-LCD 520-LCD Product Description 6' REM WT PRS LCD 0- PSI 10' REM WT PRS LCD 0- PSI 20' REM WT PRS LCD 0- PSI 6' REM WT PRS LCD 0-100 PSI 10' REM WT PRS LCD 0-100 PSI 20' REM WT PRS LCD 0-100 PSI 6' REM WT PRS LCD 0-2 PSI 10' REM WT PRS LCD 0-2 PSI 20' REM WT PRS LCD 0-2 PSI

Specifications 02 Specifications Input Power Max. Current Draw Output Status Indication Proof Pressure Burst Pressure Accuracy at 25 C*** Surge Damping 15 to 30VDC, 24VAC nom. /60 Hz* DC: 125mA; AC: 280mA 3-wire transmitter; user-selectable 4-20mA/0-5V/0-10V Dual color LED Long Term Stability ±0.25% Zero Offset (Bidirectional and Port Swap Modes Only) Zero Adjust Media Compatibility Fittings 2x max. F.S. range** 5x max. F.S. range** Ranges A and B: ±1% F.S. typical; Range C: ±1.5% F.S. typical; Range D: ±2% F.S. typical. (For less than or equal to 20 ft. (6.1 m) cable length) Electronic; 1 or 5 second averaging 0.5% Pushbutton auto-zero and digital input (2-position terminal block) 17-4 PH stainless steel ¼ NPT female thread; Overall thread length: 0.59 (conforms to ANSI/ASME B1.20.1 standard) Operational Ranges 0- psig 5/10/25/ psid 0-100 psig 10/20//100 psid 0-2 psig 25//125/2 psid Operating Conditions Temperature Compensated Range 0 to C (32 to 122 F); TC Zero <1.5% of product F.S. per sensor; TC Span <1.5% of product F.S. per sensor Sensor Operating Range -20 to 85 C (-4 to 185 F) Operating Environment -10 to C (14 to 122 F); 10-90% RH noncondensing Compliance Information Approvals RoHS, CE; NEMA4, IP65 at sensor * VFD systems and system wiring generate fields that can disrupt electrical devices Ensure that these fields are minimized and are not affecting the sensor or sensor wiring. ** F.S. is defined as full span of selected range. *** Accuracy combines linearity, hysteresis, and repeatability. NOTICE This product is a Class 2 device. This product is not intended for life or safety applications. Do not install this product in hazardous or classified locations. Read and understand the instructions before installing this product. Turn off all power supplying equipment before working on it. The installer is responsible for conformance to all applicable codes. No responsibility is assumed by Schneider Electric for any consequences arising out of the use of this material.

Installation/Wiring 03 Dimensions 6.7" (170 mm) 3.1" (78 mm) 2.4" (61 mm) Installation/Wiring Disconnect power from the power source before beginning the installation. Observe precautions for handling static sensitive devices to avoid damage to the circuitry that is not covered under the factory warranty. 1. Mount the housing using the included screws. Avoid locations where excessive vibrations occur. 2. Remove the housing cover by pressing the corner tabs. There are two tabs on each side of the housing. One side is shown below. Press tabs to remove cover (2 tabs per side) 3. Run the digital control and power source wiring and connect to the left-most terminal block. 4. The sensors and monitor assembly are matched at the factory and calibrated as a unit. They must be kept paired to obtain the accuracy stated in the product specifications. Verify that the serial numbers on the sensors match the serial number on the main housing. Main Housing serial number located on label on the top of the housing Sensor serial numbers located on the sensor labels HI PWR S/N LO PWR S/N

Installation/Wiring (Continued) 04 Installation/Wiring (Continued) 5. Run wires from the remote pressure sensor cables and connect to the pair of 4-terminal blocks at the right side of the board. To maintain the correct calibration, it is important not to confuse the high side and the low side. To assist, the sensors are labeled, HI and LO. POWER SOURCE 15 to 30 VDC/24 VAC DIGITAL CONTROL Analog Input: 0-5V/0-10V or 4-20mA Optional Digital Output POWER SIGNAL COM Zero ma Volt ON OFF 1 2 3 4 5 6 Range A B C D Power Shield Signal Common Low Sensors Hi Status LED Wire Colors (coming from sensor cable) Red Power Uninsulated Shield White/Clear Signal Black Common Model 3xx 4xx 5xx A 100 2 B 25 125 Range C 10 20 D 5 10 25 DIP Switches Num 1 2 3 4 5 6 Function Damping Test Mode Analog Port Voltage Out** Off/On* Fast/Slow Operate/Test Normal/Bidirec. Normal/Reverse Normal/Swap 0-10V/0-5V * Off position is the default setting for all DIP switches. ** Ignored in ma mode. 6. If the sensors are installed on the wrong side, they can be reversed in one of two ways: Swap the cables at the sensor end Swap the headers at the control unit end 7. Adjust the switches on the board as desired. 8. Reconnect power to the power source. Check that the green LED illuminates, indicating normal operation. If not, check the wiring. 9. Re-affix the cover onto the housing, ensuring that the cover is properly seated. Do not operate the PWR without the housing cover in place. 10. Choose sensor mounting locations that minimize cable length. Use plumbing connections of appropriate tees or equivalent, made of compatible material. Observe safety precautions for plumbing connections. Release pressure from the system. Tighten sensor connections according to ANSI B1.20.3 (hand tighten plus one turn).

Configuration 05 Configuration Test Mode Test mode overrides the output to full-scale. If the PWR is configured for current (ma) operation, Test mode sets the output to 20.0 ma. If configured for voltage (VDC) operation, Test mode sets the output to 5.0 VDC or 10.0 VDC (depending on the position of the output selection switch). Status LED LED Solid Green Flashing Green Solid Red Flashing Red Alternating Green/Red Flash Status Normal operation. Low > High; use port swap jumper or bidirectional mode. Differential pressure is too high; select a higher pressure range. Gauge pressure over sensor range; reduce line pressure or replace with a higher range device. Sensor input is below sensor range. Verify that the sensor is connected correctly. Auto Zero Function To automatically reset the output to zero pressure, press and hold the Zero push-button for 2 seconds or provide contact closure on the auxiliary remote tare terminal. To protect the unit from accidental tare, this feature is enabled only when the detected pressure is within 5% of factory calibration.