Cirprotec. Specialists in Lightning and Surge Protection for Photovoltaic Systems. Includes new plug-in SPD range and insulation monitoring device

Similar documents
Technical features OVR Surge Protective Devices Type 1 & Type 1+2

The best surge protection solution

Reliability in Surge Protection. Photovoltaic Systems.

PHOTOVOLTAIC PLANTS Comprehensive lightning protection

CONTA-ELECTRONICS. CONTA-PROTECT overvoltage protection

SURGE PROTECTION LIGHTNING & EARTHING EQUIPMENT

Surge Protection for Surveillance Systems

CPS block & CPS nano UL rd Ed. Surge protective devices (SPD)

Lightning and Surge Protection of Photovoltaic Installations. Leutron GmbH 2013 Leinfelden-Echterdingen, Germany

Surge Protection Devices Type 1+2

Overvoltage Protection Devices

2 Principle of lightning protection

Overvoltage Protection Devices

Surge Protection Devices and Surge Protection Kit

LIGHTNING AND SURGE PROTECTION PRODUCT CATALOGUE

PRF1 12.5r/PRF1 Master/ PRD1 25r/PRD1 Master Type 1 and 2 LV surge arresters

Overvoltage Protection Devices

Type of surge arrester

Surge Protective Device

wietap wietap Overvoltage Protection Tensions running high

Overvoltage Protection Devices

Low voltage. Acti 9. the efficiency you deserve. Catalogue 03/2016

mcbs, EQUIPMENT NEW PRODUCTS 2014 Voltage surge protectors & other control and signalling devices Time & light sensitive switches

Protection of PHOTOVOLTAIC SYSTEMS against LIGHTNING and OVERVOLTAGE. Surge Protection Device

US Catalog March Surge protective devices (SPDs) UL range

S400 Series HIGH EFFICIENCY SURGE PROTECTIONS. For power supply For measurement and control devices For LAN / ICT Networks

Lightning Current Equipotential Bonding SPDs

PRACTICAL EXAMPLES OF OVERVOLTAGE PROTECTION

Company Profile Surge Protective Devices

Surge Protection Devices

TT-ST-M-2-PE-24DC. Extract from the online catalog. Order No.:

Surge & Filter Protection Addressing your industrial power quality needs.

PT 3-PB-ST. Extract from the online catalog. Order No.:

Cirprotec Technical Article No. 5

OPTIMISED LUMINAIRE PROTECTION

BS th Edition wiring regulations Furse overview

SURGE PROTECTIVE DEVICES

OPTIMISED LUMINAIRE PROTECTION

Overvoltage Protection Devices

ALLTEC PROTECTION PYRAMID TM FOR PHOTOVOLTAIC SOLAR FIELD

Lightning & Surge Protection for Solar PV Plants

Reliability in Surge Protection. Surge Protection. AC & DC Power Photovoltaic Coaxial Telecom Gas Discharge Tubes.

DBPApplication. PD Devices Ltd. Unit 1, Old Station Yard, South Brent, Devon. TQ10 9AL (0)

Surge Protection Devices Ex9UE2

Modular surge protective devices (SPDs)

Modular surge protective devices (SPDs)

Page 14-4 Page Page 14-4 SURGE PROTECTION DEVICES TYPE 2 VERSIONS WITH PLUG-IN CARTRIDGE 1P, 1P+N, 2P, 3P, 3P+N, 4P

Equipment protection

ENGR. MARITES R. PANGILINAN, P.E.E.

Leutron. Lightningand. Surge Protection for Power Net Systems (SPD) with EnerPro Combi-Devices. Seite 0 von14

Autoprotected Surge Arresters New OVR Plus range

Modular surge protective devices (SPDs) Cat. Nos :

CARLO GAVAZZI Automation Components. Surge Protection Devices

Coordination of Surge protection devices

Attachment plug with surge protection for coaxial signal interfaces. Connection: N connector, male/female

voltage surge protectors low voltage type 1 (class I / B) voltage surge protectors low voltage type 2 (class II / C) Distribution board protection

Modular surge protective devices

Product Overview Surge Protective Devices

Surge protection solutions

NEW surge protective devices

MULTI-POLE PHOTOVOLTAIC SYSTEMS. COMPACT and MODULAR Housing

Extract from the online catalog SFP 1-5/120AC Commercial data Product description Technical data Standards

RESIDUAL CURRENT CIRCUIT BREAKERS OFE (6 ka)

ELPROMA NTSprotect Surge Protection

Photovoltaic System Components Connection And Protection

2U Congestion Alert Rack Insert for UK

PT 2X2-HF-24 DC-ST. Extract from the online catalog. Order No.:

Deploying surge protective devices (SPDs) in photovoltaic systems. Technical Information

Surge Protective Devices OVR Series - Enclosed SPD Mining and Aggregates

SURGE PROTECTOR. lighting. for.

TT-2-PE-M-24DC. Extract from the online catalog. Order No.:

Lightning and Surge Protection for PV Systems

M ISCELLANEOUS A CCESSORIES O BSTRUCTIONS LIGHTS MISCELLANEOUS ACCESSORIES OBSTRUCTION LIGHTS

3 Design of the electrical installation protection system

Overvoltage Protection

LIGHTNING PROTECTION FOR ROOFTOP PV PLANTS LIGHTNING & SURGE PROTECTION SYSTEM

SURGE 8.1 EDITION PROT ELECTRICAL INSTALLATIONS COMPUTER NETWORK TELEPHONY RADIOCOMMUNICATIONS

Manual for overvoltage protection for LED luminaires rev 1

Application-optimised DEHNshield Combined Arrester

DIN Series MINIATURE CIRCUIT BREAKERS, RESIDUAL CURRENT CIRCUIT BREAKERS. Introducing the DIN Series High-quality, high-performance circuit breakers

PT 5-HF- 5 DC-ST. Extract from the online catalog. Order No.:

TT-2-PE- 24DC. Extract from the online catalog. Order No.:

Surge Protective Device

Lightning and Surge Arresters

DEHN protects Photovoltaic Systems

A.3 Lightning and surge voltage protection

Measurement and Control CVM-A1500. Power analyzer with power quality. Quality in every sense of the word. Technology for energy efficiency

LPI PRODUCT Summary Brochure

PT 2X2-24DC-ST. Extract from the online catalog. Order No.:

White Paper Lightning and surge protection for rooftop photovoltaic systems

Chapter J. Protection against voltage surges in LV. Contents. General. Overvoltage protection devices. Choosing a protection device

the data line series

General Catalog 7 th edition

ISOMETER isoev425 with coupling device AGH420

PROTEC Z LV the universal solution for transient switching protection for LV motors, generators, transformer LV secundaries, VSD and UPS equipment

UMG 20CM. UMG 20CM 20 Channel Branch Circuit Monitoring Device with RCM. Harmonics via analysis channel RCM. Alarm management.

ISOMETER isopv with coupling device AGH-PV

Increased Safety for Switchgear Cabinets CI Arresters with Integrated Backup Fuse

Reliability in Surge Protection. Surge Protection. AC & DC Power Photovoltaic Coaxial Telecom Gas Discharge Tubes.

Section 4 Ground-Fault Protection Devices

Transcription:

A1 Cirprotec Specialists in Lightning and Surge Protection for Photovoltaic Systems Includes new plugin range and insulation monitoring device

Complete protection systems with maximum continuity of service > Photovoltaic installations are highly exposed to atmospherical phenomena as well as to the resulting power surges and induced overvoltages. 80% of the damages affecting inverter units happen as a result of overvoltages. Almost 100% of service interruptions in these plants are associated to atmospherical phenomena (lightning strikes or discharges). It is therefore very important that both the DC and AC electrical lines in photovoltaic systems be protected with the appropriate surge protection devices. One level should not be considered without the other, as failures can occur in such a system thus wasting precious time, money and essential resources not to mention the repair costs involved. > With its Global PV Protection Concept, CPT Cirprotec extends protection also to signal lines (CCTV, Ethernet, etc.) and prevents further damages caused by direct lightning strikes and discharges. A set of specific solutions of Cirprotec provide maximum COS (Continuity of Service) to the installation: Insulation Monitoring Device and selfreclosing MCB for the DC side, Grounding System Monitor and selfreclosing RCCB for the AC side. Thus assuring not only the safety of the installation, but also the Continuity of Service, consequently, PV projects guarantee the expected ROI. (1+IRR) t Cirprotec PV Protection 0% Maintenance 0% Service Interruptions of expected ROI ISOCHECK PV GCHECK DC: IMD, MCB AC: RCCB, Grounding Lightning Protection Service Continuity ISOCHECK PV Insulation Monitoring Device 6 to. NIMBUS ESE Lightning rod with Early Streamer Emission. Standards: NFC 17102. Radius > 100 m. MCBDCR DC selfreclosing MCB for PV (main switch & string). 5 or 4,5 DIN to 63 A and. Optional selfreclosing in. Lightning Arrester Uoc max: 600/ 3 DIN, plugin. For highly exposed installations and/or equipped with Lightning Protection System. Selfreclosing GCHECK Grounding System Monitor Continuous monitoring of the status of the grounding connection. Checking of the earth loop resistance Alarm threshold: 0100 Ohms (user defined) Alarm output PSC Lightning Arrester Uc: 275/440 V (LN) (NPE) 1,5 kv (TT) 4 DIN, 1phase and 3phase, plugin. For highly exposed installations and/or equipped with Lightning Protection System. RCHECK Selfreclosing Earth Leakage relay RCCB Insulation test which keeps the system from reconnecting if leakage persists. 4 or 8, 1phase and 3phase. Idn: 30 300 ma In: 40 A Un: 230/400 V 5060 Hz PSC4 PSC2 Selfreclosing Surge Protection Surge Protector Imax (8/20 µs): / 3,8 kv 2 DIN only. Monobloc. Surge Protector Imax (10/350 µs):12,5 ka 3 DIN, pluggable surge. Tested according to 5053911. Backup fuse not required in PV installations where rated current < 80 A. 5053911 CS Surge Protector Uc: 275 / 440 V Imax (8/20 µs): (LN) (NPE) 1,5 kv (TT) 2 or 4 DIN, 1phase and 3phase, monobloc. CS CS PSM Surge Protector Uc: 275 / 440 V Imax (8/20 µs): (LN) (NPE) 1,5 kv (TT) Pluggable surge. 2 or 4 DIN, 1phase and 3phase. PSM4 PSM2 These s are specific for DC applications, providing Common & Differential Mode protection. Available also with remote signalling and Class I.

Surge protectors for each side of the PV installation DC Protection 5053911 Range Model CS2340/600 CS2340/1000 PSM340/600 PV PSM340/1000 PV PSC312,5/600 PV PSC312,5/1000 PV Code w/out signalling 77707360 77707362 77707850 77707852 77738370 77738375 Code with signalling 77707361 77707363 77707851 77707853 77738371 77738376 Un (Uoc max) Imax (8/20 µs) 65 ka Iimp (10/350 µs) 12,5 ka In IEC 6164311 3,8 kv 4 kv 3,6 kv ta Iscwpv 100 A Backup fuse 10 A 80 A* 10 A Format Monobloc Plugin All products are specific for DC applications. * Backup fuse not required in PV installations where rated current < 80 A. AC Protection Range CS CS PSM4 PSM2 PSC4 PSC2 Model CS40/400 CS40/230 PSM440/400 TNS PSM240/230 TNS PSC412,5/400 TNS PSC212,5/230 Code w/out signalling 77705458 77705248 77707956 77707906 77738455 77738255 Code with signalling 77705459 77705249 77707957 77707907 77738456 77738256 Poles Network TNCS, TNS Uc 50/60 Hz 275 / 400 V Imax (8/20µs) 65 ka Iimp (10/350 µs) 12,5 ka In 15 ka 15 ka ta Icc IEC 6164311 Format Monobloc Plugin All DC & AC protectors have visual status indication. Each product is available also with IR (Remote Indication), ie, remote signalling of the status of protection, IP = 20.

Complete protection systems > Photovoltaic installations are highly exposed to atmospherical phenomena as well as to the resulting power surges and induced overvoltages. 80% of the damages affecting inverter units happen as a result of overvoltages. Almost 100% of service interruptions in these plants are associated to atmospherical phenomena (lightning strikes or discharges). It is therefore very important that both the DC and AC electrical lines in photovoltaic systems be protected with the appropriate surge protection devices. One level should not be considered without the other, as failures can occur in such a system thus wasting precious time, money and essential resources not to mention the repair costs involved. Lightning and Surge Protection: rooftop and largescale systems Rooftop systems Surge protectors for each side of the PV installation DC Protection DC/AC Protection Roof Kit for microgeneration This is a box for combined protection of DC&AC sides of the Inverter with surge protectors. It s a Plug&Play solution for application in microgeneration and cogeneration PV systems, especially in the residential and tertiary sectors. Custom projects only. Range ISOCHECK PV PSM340/600 PV PSM340/1000 PV PSC312,5/600 PV PSC312,5/1000 PV Code w/out signalling 77707360 77707362 77707850 77707852 77738370 77738375 Code with signalling 77707361 77707363 77707851 77707853 77738371 77738376 Imax (8/20 µs) L L Iimp (10/350 µs) N In IEC 6164311 Service Continuity Lightning Protection Surge Protection DC: IMD, MCB AC: RCCB, Grounding ISOCHECK PV MCBDCR Insulation Monitoring Device DC selfreclosing MCB for PV (main switch & string). 6 to. Rp: radius of protection 100 m with Nimbus ESE 5 or 4,5 DIN to 63 A and. Optional selfreclosing in. Lightning rod with Early Streamer Emission. Lightning Arrester Signal lines in photovoltaic installations and, to a very particular extent, communication and data management interfaces of the inverter, require the appropriate overvoltage protection for each protocol: RS232, RS485, CCTV, Ethernet, ADSL, ISDN, etc. This is especially true when the cable runs are long, potentially, the degree of exposure to induced overvoltages increases significantly. Uoc max: 600/ 3 DIN, plugin. For highly exposed installations and/or equipped with Lightning Protection System. Standards: NFC 17102. Radius > 100 m. DC to AC Surge Protector Surge Protector Imax (8/20 µs): / 3,8 kv 2 DIN only. Monobloc. Imax (10/350 µs):12,5 ka 3 DIN, pluggable surge. Tested according to 5053911. Backup fuse not required in PV installations where rated current < 80 A. These s are specific for DC applications, providing Common & Differential Mode protection. Available also with remote signalling and Class I. 12,5 ka 3,8 kv 4 kv Backup fuse 100 A 10 A 80 A* 10 A Monobloc Format 3,6 kv Plugin All products are specific for DC applications. * Backup fuse not required in PV installations where rated current < 80 A. AC Protection Largescale systems Selfreclosing NIMBUS ESE 65 ka Iscwpv ta The radius of protection of the Nimbus ESE lightning rod covers the PV panels and all electrical and electronic equipment of the PV installation. As opposite to passive Franklin LPS, PV panel performance is not affected by shadowing elements. Nimbus is the best solution to protect PV installations against direct lightning impacts in a most cost efficient way. The protection is calculated according to the NFC 17102 standard. CS2340/1000 Un (Uoc max) L+ CS2340/600 Model Inverter 5053911 PV Panels Inverter 5053911 Meter When cable runs exceed a 20 m distance, a complete protection is only achieved with the installation of additional surge protectors in the correct position. String combiner units are an example of highly exposed devices. Installing a surge protector as close to them as possible allows to better manage residual voltages (left upstream by the surge protectors at the inverter) as well as induction phenomena. Range CS CS PSM4 PSM2 PSC4 PSC2 Model CS40/400 CS40/230 PSM440/400 TNS PSM240/230 TNS PSC412,5/400 TNS PSC212,5/230 Code w/out signalling 77705458 77705248 77707956 77707906 77738455 77738255 Code with signalling 77705459 77705249 77707957 77707907 77738456 77738256 Poles Uc 50/60 Hz 275 / 400 V 65 ka In 15 ka 15 ka Imax (8/20µs) Iimp (10/350 µs) ta Icc IEC 6164311 Format = (Surge Protective Device) Rp: Radius of protection 100 m with Nimbus ESE TNCS, TNS Network Monobloc 12,5 ka Plugin All DC & AC protectors have visual status indication. Each product is available also with IR (Remote Indication), ie, remote signalling of the status of protection, IP = 20.

Insulation & Grounding System monitors, selfreclosing MCB & RCCB, signal line, ESE lightning rod Insulation monitoring device (DC) Grounding system monitor (AC) Model ISOCHECK PV 600 ISOCHECK PV 1000 Code 77706704 77706703 Us 230 V 230 V Uoc Ran 30...80 Ω 30...80 Ω Modules 6 6 NEW Model GCHECK 120 V GCHECK 230 V Code 77706550 77706500 Us 120 V 230 V Modules 2 2 Alarma threshold 0100 Ω 0100 Ω Alarm signal Remote Remote NEW Selfreclosing PV MCB (DC) Selfreclosing RCCB (AC) Self reclosure Model MCBDC1000 MCBDC600 Code 550870 550879 550850 550859 Protection String Inverter String Inverter Uoc In 10 A 63 A 10 A 63 A Un 880Vdc 550 Vdc Modules 4+1/2 5 Reclosure Manual Automatic (optional) Remote Signal Yes B curve. DC2IB class. Available with C curve for 440 Vdc models. Model RCHECK 24030 RCHECK 440300T Code 554411 554322 Phases P+N 3P+N Poles 2 4 Un 230/400 Vac 5060Hz In 40 A Idn 30 ma 300 ma Modules 4 8 Class A IEC 1008.1 Timed sequence & Reclosure insulation test Timed sequence Signal line s ESE lightning rods Model Protocol 232 RF Tel. Lines Model DB9 12V9HS CT 10 CCTV DINADSL Code 77820145 77801670 77840115 Uc 16 V 60 V 180 V <25 V (LGND) <500 V (LPE) <0,6 kv <0,2 kv In 0,5 ka 10 ka 5 ka Imax 0,5 ka 10 ka Wires 7+GND BNC Connect 2 Model CPT1 CPT2 CPT3 Code 77901100 77901200 77901300 Level I 42 m 58 m 79 m Level II 51 m 70 m 86 m Level III 57 m 75 m 97 m Level IV 65 m 84 m 107 m Level of protection acc. to product standard NFC 17102. CIRPROTEC, S.L. Lepant, 49 08223 Terrassa (BARCELONA) SPAIN Tel. (+34) 93 733 16 84 Fax. (+34) 93 733 27 64 export@cirprotec.com 50080154v1 D.L.B. 37.894 2011 www.cirprotec.com