P2-04AD Analog Input. Removable Terminal Block Specifications

Similar documents
General Specifications. P2-8AD4DA-2 Analog Input/Output

P2-04DA Analog Output. Removable Terminal Block Specifications

P2-16AD-2 Analog Input. Connector Specifications

P2-04DAL-2 Analog Output. Removable Terminal Block Specifications

General Specifications. P2-08NTC Thermistor. The P2-08NTC module provides eight Thermistor input channels for use with the Productivity2000 System.

General Specifications. P2-08THM Analog Input

Removable Terminal Block Specifications

P3-08RTD Analog Input

P2-HSO High-Speed Isolated Sinking/Sourcing Output. Connector Specifications

General Specifications. P2-SCM Serial Communications

P3-SCM. General Specifications

P3-RS Remote Slave. Remote Slave Specifications. The P3-RS is a full-featured, highperformance,

P1-540 CPU. CPU Specifications

Analog Voltage Combination Module

P3-530 CPU. CPU Specifications. The P3-530 is a high-performance CPU for use with the Productivity3000 Programmable Automation Controller.

Twido Programmable Controllers

24VDC Bipolar Digital In 10-28VDC, 0.5A Sourcing Digital Out 0-20mA Sourcing Analog In/ Out HE800MIX906 / HE-MIX906* * HE- denotes plastic case.

24VDC Bipolar Digital In 10-28VDC, 0.5A Sourcing Digital Out 4-20mA Analog In/Out HE800MIX902 / HE-MIX902* * HE- denotes plastic case.

User safety and equipment protection guidelines

CompactLogix Power Supplies Specifications

170 ADM to 60 VDC Module Base / 170 ADO Pt. Relay Out Module Base. Version 1.0

PGR-3200 MANUAL INSULATION MONITOR

P3-RS Remote Slave Module

Rhino Redundancy Module PSM24-REM360S. Operating Instructions

Digital ac/dc (24V) Input Module

Rhino Buffer Module PSM24-BFM600S. Operating Instructions

Environmental Specifications CompactLogix Controllers and Compact GuardLogix 5370 Controllers

This Datasheet for the IC660BBA026. Block 24/48Vdc Analog Current Source 6 Inputs.

170 ADO VDC - 32 Pt. Discrete Output Module Base

This Datasheet for the IC660BBA104. Block 115Vac/125Vdc Analog Current Source 4 Inputs / 2 Outputs

CompactBlock Guard I/O EtherNet/IP Safety Modules

Digital ac/dc (24V) Input Module

V E1B Snap-in I/O Module

H Series PLC. ! : Indicates Compulsion. EH-150 Analog input module EH-AXH8M Instruction manual. Safety precautions DANGER CAUTION COMPULSION

170 ADI VDC - 16 Pt. Discrete Input Module Base

Isolated Voltage Input 7B31 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Isolated, Voltage or Current Input 7B30 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Chapter 1 Introducing the OM-USB Functional block diagram... 5

Signal Doublers. VariTrans A 20300

NI REM Remote I/O Overview DATASHEET. Analog Output Module for Remote I/O

V E2B Snap-in I/O Module

Installation, Operation and Maintenance Manual

Communication & Networking

Isolated, Process Current Output 7B39 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Model 3750 Multifunction I/O Card

Model SPDT Switch Module

A0750 AC-DC POWER MODULE

TM3TI4 module TM3-4 inputs temperature

Model A Mini AC/DC Clamp Meter. User's Guide

em4 Accessories Digital expansions

VIBRATION MONITOR CX-RLY

6220 Ethernet-Based Voltage Measurement Module

HITACHI. EH-150 series PLC EH-RTD8 Resistance Temperature Detective input module Instruction manual. Safety precautions

TM3TI4 module TM3-4 inputs temperature

SERIES VAC PANEL MOUNT

DeltaV Bulk Power Supplies

Isolated Linearized RTD Input 5B34 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

V E1B Snap-in I/O Module

Isolated Process Current Input 7B32 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

TM3AI4 module TM3-4 analog inputs

Isolated Process Current Input with Loop Power 7B35

TM3TM3 module TM3-2 temperature inputs and 1 analog output

Temperature I/O Module HE800MIX963 / HE-MIX963* * HE- denotes plastic case.

P USB 2.0 (Type B) Port - Programming - Online monitoring

Analog Output Module. ST-4xxx. User Manual CREVIS Co.,Ltd. Version FnIO S-Series

The IQ300 wall mount load cell indicator is a precision digital indicator for load cell and strain gauge applications.

SMVector Additional I/O Module Installation and Operation Manual

PanelView Plus/VersaView CE Terminals and Display Modules

REDUNDANCY MODULE TSP-REM360 AND TSP-REM600

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL:

RTU500 series Data Sheet Power Supply CP-E 24/2.5

Mini Digital Multimeter

OPERATING INSTRUCTIONS AND SPECIFICATIONS. NI 9208E 16-Channel, ±20 ma, 24-Bit Analog Input Module

Mini Digital Multimeter

ICS Regent. Relay Output Modules. Low Power and High Power (T3446L and T3446H) PD-6017

POINT I/O Family. Chapter. Overview

Twido Programmable Controllers Discrete I/O Modules

S66 Series Electronic Fan Speed Control

MODEL: M5DY SEN TRONIC AG CURRENT LOOP SUPPLY. [2] POWER INPUT AC Power M: V AC (Operational voltage range V, Hz)

Analog Input/Output Modules

LAUREL. Laureate Digital Panel Meter for Load Cell & Microvolt Input ELECTRONICS, INC. Features. Description

Introduction. Features. Applications DR45 SERIES AC SINGLE PHASE OUTPUT DIN RAIL MOUNT SSRS PRODUCT SELECTION

CPCI-PS24 24V-Power Supply

FP-PS-4. Features. Installation

AC-DC POWER SUPPLY UNIVERSAL INPUT, DESK TOP, WATTS MEDICAL APPLICATIONS MUI310-A Series

ACCESS 9340/9360 Meter Input/Output Module

FLEX Ex Spring Clamp Terminal Base

Perle IDS-108F(XT) Unmanaged 10/100 Ethernet Switches. Installation Guide. P/N (Rev G)

Power supply CP-C 24/5.0

4-20 ma Analog Input Module HE800ADC020 / HE800ADC120 HE-ADC020* / HE-ADC120* 12-Bit Resolution * HE-denotes plastic case.

Analog Monitor Installation Manual

Model 7705 Control Module

Power Supply HARTING pcon

1492-SP Supplementary Protectors

AC Input /AC Output. Module

IO-PT4. Component identification. User safety and equipment protection guidelines. Unitronics Industrial Automation Systems 1

Model SPDT 5A Relays

Model 3724 Dual 1x30 FET Multiplexer Card

Mid-span 802.3af PoE Injector. Installation Guide KPOE-100

Isolated Voltage Input 3B30 / 3B31 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Transcription:

WARNING: To minimize the risk of potential safety problems, you should follow all applicable local and national codes that regulate the installation and operation of your equipment. These codes vary from area to area and it is your responsibility to determine which codes should be followed, and to verify that the equipment, installation, and operation are in compliance with the latest revision of these codes. Equipment damage or serious injury to personnel can result from the failure to follow all applicable codes and standards. We do not guarantee the products described in this publication are suitable for your particular application, nor do we assume any responsibility for your product design, installation, or operation. If you have any questions concerning the installation or operation of this equipment, or if you need additional information, please call Technical Support at 77-844-42. This publication is based on information that was available at the time it was printed. At AutomationDirect.com we constantly strive to improve our products and services, so we reserve the right to make changes to the products and/or publications at any time without notice and without any obligation. This publication may also discuss features that may not be available in certain revisions of the product. Removable Terminal Block Specifications Part Number P2-RTB P2-RTB-1 Number of positions 18 Screw Terminals 18 Spring Clamp Terminals - 16 AWG (.51-1.1 mm²) 28-16 AWG (.81-1.1 mm²) Wire Range Solid / Stranded Conductor Solid / Stranded Conductor /64 in. (1.2 mm) Insulation Maximum /64 in (1.2 mm) Insulation Maximum 1/4 in (6-7 mm) Strip Length 19/64 in (7-8 mm) Strip Length Conductors USE COPPER CONDUCTORS, 75ºC or equivalent. Screw Driver Width 1/8 in (.8 mm) Maximum Screw Size M2 N/A Screw Torque 2.5 lb in (.28 N m) N/A Sales 8-6-45 1 9.45V 2 18.2 UNDER 4 SPARE 2 P2-4AD Analog Input The P2-4AD Voltage/Current Analog Input Module provides four channels for receiving ±1VDC, ±5VDC, - 5 VDC and - 2 ma signals for use with the Productivity2 system. Warning... 1 Removable Terminal Block Specifications........ 1 General Specifications... 2 Input Specifications... 2 Wiring Diagram and Schematic... Module Installation Procedure... 4 QR Code... 4 Hot Swap Information... 4 Wiring Options... 5 Module Configuration... 5 Linear Scaling... 6 Non-Linear Scaling... 6 OLED Panel Display Menus... 7 Terminal Block sold separately, (see wiring options on page 5). Warranty: Thirty-day money-back guarantee. Two-year limited replacement. (See www.productivity2.com for details). www.productivity2.com 1

General Specifications Operating Temperature Storage Temperature Humidity Environmental Air Vibration Shock Field to Logic Side Isolation Insulation Resistance Heat Dissipation Enclosure Type º to 6ºC (2º to 14ºF) -2º to 7ºC (-4º to 158ºF) 5 to 95% (non-condensing) No corrosive gases permitted IEC668-2-6 (Test Fc) IEC668-2-27 (Test Ea) 18VAC applied for 1 second > 1MΩ @ 5VDC 1.4 W Open Equipment Agency Approvals UL58 File E19594, Canada & USA CE (EN6111-2*) Module Keying to Backplane Electronic Module Location Any I/O slot in a Productivity2 System Field Wiring Use ZIPLink Wiring System or removable terminal block (not included). See Wiring Options on page 5. See the EU Directive topic in the Productivity Suite EU Directive Help File. Information can also be obtained at: www.productivity2.com Connector Type (not included) 18-position removable terminal block Weight 9g (.2 oz) *Meets EMC and Safety requirements. See the D.O.C. for details. Input Specifications Input Channels 4 Module Signal Input Ranges ±1 VDC, ±5 VDC, -5 VDC, -1 VDC, -2 ma Signal Resolution 16-bit 1 LSB = 1 count ±1 V = 5μV Resolution Value of LSB (least significant bit) ±5 V = 152μV -5 V = 76μV -1 V = 152μV -2 ma =.5μA Data Range -6555 counts unipolar -2768 to 2767 counts bipolar Maximum Continuous Overload ±1 ma, current input ±1 V, voltage input Input Impedance 1MΩ±1% voltage input 25Ω±.1% 1/4 W current input Hardware Filter Characteristics Low Pass 1st order, -db @ 48Hz Sample Duration Time 2ms per channel (does not include ladder scan time) All Channel Update Rate 8ms Open Circuit Detection Time Zero reading within 1s (current input only) Conversion Method Successive approximation Accuracy vs. Temperature ±1PPM / ºC maximum Maximum Inaccuracy.1% of range voltage,.2% of range current (including temperature drift) ±.1% of range max., ±1 V & ±5 V Linearity Error (end to end) ±.15% of range max., -1 V, -5 V & -2 ma Monotonic with no missing codes Input Stability and Repeatability ±.5% of range (after 1 min. warmup) Full Scale Calibration Error ±.2% of range maximum Offset Calibration Error ±.65% of range maximum Max Crosstalk -96dB, 1 LSB Recommended Fuse (external) Edison S5-2-R,.2A fuse on current inputs only External DC Power Required 24VDC (-2% / 25%) 5mA 2 www.productivity2.com Tech Support 77-844-42

OLED Panel Display Power On Hold SEL button down to cycle through primary screens. Release button to select screen. PASSED SELF TEST Appears initially SETUP INFO STATUS INFO UNITS DECIMAL COUNTS UNITS HEX COUNTS UNITS /-V, ma,v These screens will then auto cycle P2-4AD Fw. Rev. 1. 5V, 1V, /-5V, /-1V, -2mA This screen will auto cycle with status information End of Status Menu List Error Messages: An existing error will be inserted into the cycling Status Info screen. Momentarily Press SEL button to toggle through secondary displays 1 2 SPARE 4 1 H 2 H SPARE 4 H 1.V 2.V SPARE 4. Channels Enabled: 4 MISSING EXTERNAL 24VDC SELFTEST FAIL REPLACE MODULE MISSING CONFIG DATA End of Status Menu List Fault Messages Appear in place of data during a fault condition. 1 OVER 2 UNDER 4 Input signal is OVER the maximum detectable by the module. Input signal < range minimum. (Voltage only) Sales 8-6-45 www.productivity2.com 7

Linear Scaling Non-Linear Scaling The Scale (Linear) function can be used to: Convert analog field input signals from the range which is native to the analog input module to an application specific range. Make other linear conversions in ranges appropriate to the application. The Scale (Non-Linear) function can be used for Non-Linear applications. Level Tank Level Level 6555 22 125 Tank Level Select the Input and Output tags appropriate for the application. Convert raw input signals to engineering units for use in the program, or convert engineering units to output signals for control purposes 1 2 4 5 6 6.5 7.5 1 1.55 2.25 4.55 6.75 7 Select the minimum and maximum values of the raw input signal. These values will relate to the minimum and maximum scaled values. max min min max 7 6 5 4 2 1 1 2 4 5 6 7 6 www.productivity2.com Tech Support 77-844-42

Wiring Diagram Schematic Current Sinking Input Circuits An Edison S5-2-R.2A fast-acting fuse is recommended for all current loops. 2-Wire 4-2 ma 2-Wire -Wire Current -Wire 4-Wire 4-2 ma 4-Wire Voltage AC or DC Voltage Input Circuits Optional Power Supply 4-Wire -Wire Voltage -Wire User Supplied AC or DC Power 4-Wire fuse.2a fuse.2a - fuse.2a - - V V 24 VDC User Supplied Power V Sales 8-6-45 I Power Supply I V 24VDC User Supplied Power V I Notes: 1. Shield connected to signal source common. 2. If current is chosen, I must be jumped to V. For example when using 4-2 ma source for Input, I must be jumped to V. V1 I1 V2 I2 V I V4 I4 24VDC- - 24VDC 24 VDC User Supplied Power INTERNAL MODULE CIRCUITRY 1 2 4 5 6 7 8 9 1 11 12 1 14 15 16 17 18 ISOLATED ANALOG CIRCUIT MON www.productivity2.com CH1 ADC CH2 ADC CH ADC CH4 ADC ISOLATED ANALOG CIRCUIT POWER

Module Installation QR Code WARNING: Do not apply field power until the following steps are completed. See hot-swapping procedure for exceptions. 2 rotate to seated position Step One: Align module catch with base slot and rotate module into connector. Step Two: Pull top locking tab toward module face. Click indicates lock is engaged. Locked 1 Align with slot Unlocked Use any QR Code reader application to display the module s product insert. Step Three: Attach field wiring using the removable terminal block or ZIPLink wiring system. WIRE STRIP LENGTH Caution: If possible, remove field power prior to proceeding. If not, then EXTREME care MUST be taken to prevent damage to the module, or even personal injury due to a short circuit from the live terminal block. Important Hot-Swap Information The Productivity2 System supports hot-swap! Individual modules can be taken offline, removed, and replaced while the rest of the system continues controlling your process. Before attempting to use the hotswap feature, be sure to read the hot-swap topic in the programming software s help file or our online documentation at AutomationDirect.com for details on how to plan your installation for use of this powerful feature. 4 www.productivity2.com Tech Support 77-844-42

Wiring Options ZIPLink Connection System 1 Cable ZIPLink Module = Complete System ZIPLink pre-wired terminal block cables.5m (1.6FT) cable 1.m (.FT) cable 2.m (6.6FT) cable ZIPLink Modules ZL-P2-CBL18 ZL-P2-CBL18-1 ZL-P2-CBL18-2 Module Configuration Using the Hardware Configuration tool in the Productivity Suite programming software, drag and drop the P2-4AD module into the base configuration. Select Automatic Module Verification or No Verification and Enable Hot Swap. Select Range type for each input. If desired, assign a User Tagname to each input point (channel) selected and to each Status Bit Item. Feed through ZL-RTB2 Terminal Block with pigtail cable 2 1.m (.FT) cable 2.m (6.6FT) cable ZL-P2-CBL18-1P ZL-P2-CBL18-2P Screw Terminal Block only P2-RTB (Quantity 1) 4 Spring Clamp Terminal Block only P2-RTB-1 (Quantity 1) Sales 8-6-45 www.productivity2.com 5

Document Name Edition/Revision Date P2-4AD-DS 1st Ed. Rev A 2/22/216 Copyright 216, AutomationDirect.com Incorporated/All Rights Reserved Worldwide 8 www.productivity2.com Tech Support 77-844-42