Touch screen operator unit

Similar documents
HT101. User terminal. Function

IMIO100 IMIO105. DDC controllers. Summary

mark150s mark150/485s DDC controllers Summary

Evo2. Free programmable room controller. Summary

MXPLC. Compact PLC process station. Summary. Application HVAC control systems, data acquisition, interfacing 3 rd party systems.

UC102 basic version with display and knob UC102BL version with display, knob and backlight UC102DK version without knob and display

Communicative controller for VAV systems

Energy Web Server. Viale Borri 231, Varese - Italy. Cat. no: PM1WS255

Control Panel CP600 CP651, CP651-WEB

Control Panel CP600 CP635, CP635-B, CP635-WEB

Control Panel CP600-eCo CP604, CP604-B

Control Panel CP600 CP635-FB, CP635-FW

MXIO. Compact I/O module. Summary. Application Compact I/O module for data acquisition and HVAC control systems. Function

CLIMATIX STEQ, STCM DATASHEET FOR CONTROLLING, SWITCHING AND MONITORING FUNCTIONS. POWER SUPPLY RELAY OUTPUTS. Power supply. 4.

Communication over Modbus protocol Connection with multiple controllers Application upgrade by using an SD 1) card or a USB stick

Web interface BACnet/IP

HMISCU6A5 3 5 color touch controller panel - Dig 16 inputs/10 outputs

F1000 User's Manual. (Version: V1.01)

HMISCU8A5 5 7 color touch controller panel - Dig 16 inputs/10 outputs

Merbon Menu Reader. Installation and setup V1.0 1

Communicative heating controller, Ethernet

HMISCU6A5. Main. 60 right 40 top 60 bottom

256 MB RAM. 256 MB 32 bits RISC Cortex-A8 600MHz SD Card Slot. N/A USB Host. N/A USB Client

exware Series Operating Instructions

DSTHM-2 COMBINED T AND RH DUCT TRANSMITTER. Mounting and operating instructions

Designed for commercial, residential and industrial applications, guarantee rapid installation with few and easy connections.

HMISCU6B5 3 5 color touch controller panel - Dig 8 inputs/8 outputs +Ana 4 In/2 Out

Automation for a Changing World. Delta Programmable Logic Controller DVP Series

DVB-S/S2 to IP UDP/MPTS Gateway User Manual

TPC70Display and Operator Panel

M-bus web server. Meters and Energy Cost Allocation WTV676-HB6035

User Manual. cmt-iv5 Startup Guide

HPS-M -2 DIFFERENTIAL PRESSURE TRANSMITTER. Mounting and operating instructions

Modbus TCP/RTU MP-Bus converter

HMISCU6B5. Main. 60 right 40 top 60 bottom

DVBCommunity - cообщество профессионалов ЦТВ 4IN1 DVB-S2 IP/SPTS IRD with 4CI >>User Manual

TPC84 Display and Operator Panel

MM-IM. Large works automation And data gateway. PRODUCT DATASHEET

DATA SHEET Advanced Graphical Interface, AGI 100 series

QUICKSTART Smart EnOcean Gateway DC-GW/EO-IP

MI 2792A PowerQ4 Plus

TM251MESC controller M251 Ethernet CAN

STR-3 STANDARD 3-PHASE 230 VAC TRANSFORMER CONTROLLER. Mounting and operating instructions

Manual Version: V1.00. Video Decoder Quick Guide

User Manual. cmt-svr Startup Guide

HMISCU8B5 5 7 color touch controller panel - Dig 8 inputs/8 outputs +Ana 4 In/2 Out

Phase comparator. User manual Document version: 02i00 Update:

EY-WS 500: Web server for moduweb Vision and moduweb500 BACnet networks

User Manual. cmt-svr Startup Guide

Original operating instructions. Fail-safe SmartPLC with Profinet slave interface AC402S /00 06/2016

Operator units CDPX Key features

DATA SHEET Advanced Graphical Interface, AGI 100 series

XBTGC2330T 5 7 LCD TFT color controller panel - 16 inputs/16 outputs source

NAT Proxy Server. Administrator Installation and Configuration Guide. 06NATPM.IX1.01a.en1

NAT Proxy Server. Administrator Installation and Configuration Guide. 08NATPM.IX2.00c.en2

PIGEON RB100-CM3. Features. Applications

-U- Type discontinued

1. Short description. 2. Features. 3. Technical parameters

Power Meter PowerMonitor 500

TM200CE24T controller M IO transistor Source+ Ethernet

SRD x DVB- S/S2 SD/HD Decoder

DATA SHEET Advanced Graphical Interface, AGI 300 series

Room sensors QFA4160 QFA41 D AQF4150 AQF3153. Symaro. for relative humidity and temperature with calibration certificates

etop Series 500 Operating Instructions

PXM20-E. Operator unit BACnet auf Ethernet/IP DESIGO PX

TM251MESC controller M251 Ethernet CAN

NIEx9. Metasys. BAS network automation Supervisory controllers. Network Integration Engine

HMISTO " wide screen touch panel, Ethernet

LXM32SD18M2 motion servo drive - Lexium 32-single phase supply voltage 115/230V - 0.5/1.kW

Quick Startup Guide. datafeed uagate SI. Version: EN Copyright 2016 Softing Industrial Automation GmbH

OMNI Expandable HMI Panel Computer with Intel Celeron J1900/ N2807 Processor

OPERATING INSTRUCTION. Control Panels CP600-Pro CP6605, CP6607, CP6610, CP6615, CP6621

HMISBC Rear Module controller panel - Dig 8 inputs/8 outputs +Ana 4 In/2 Out

Installing the Cisco Unified Videoconferencing 3545 MCU

PanelView Plus/VersaView CE Terminals and Display Modules

DKG-210 UNIVERSAL INTERNET GATEWAY UNIT

RMZ792. Bus Operator Unit. Building Technologies HVAC Products. Synco 700

Domino DFWEB. DFWEB: interface module between Domino bus and Ethernet network with Web-Server function. Module Connection. Domino

i-page User Guide Issue 1

QSW16M 16 Chn PoE managed switch

A-307. Mobile Data Terminal. Android OS Platform Datasheet

IM /2016 REV01 LACI Production Monitoring Module

Quick reference guide 3D sensor O3D3xx

Codian IP VCR IP VCR 2200 Series

Operating instructions. Switching amplifier DN0210 DN / / 2015

Output Signal. 22DTM-16 BACnet DC V, DC V. Electrical data Power Supply DC V, ±10%, 0.3 W

Hygro-/Thermometer. Operating Manual GFTH 95

USER MANUAL. Longo programmable controller LPC-2.MC8 Main module. Version 10

C inch SSD Contents

DC connector: 5VDC, 2,5A, round; 2,1x5,5x10 mm, inside positive External power supply: AC 230V 50/60Hz, 5V 2,5A out

GENERAL INFORMATION ipro SERIES (v.1. (v.1.2.2)

CPC 01/02. Description. x86 Computer Module. Datasheet

General information. Display. Control elements

Luminato. Quick Start Manual. Teleste Corporation. Luminato First Time Installation. SW version 1.1.2

4-1. This chapter explains HMI settings.

GREENBOX EV. User Guide. Revision 1.3

Technical Manual Nova: Cabinet Security Management System (CSMS)

3G WI-FI HOTSPOT USER MANUAL HHTSPT3GM42.

1/2 Description XV400 Flexible in Application

ex700 Series Operating Instructions

Transcription:

HT200 Touch screen operator unit Summary HT200 is a terminal with 7 touch screen for monitoring and control of multiple PLC controllers mark... with Merbon runtime, or controllers with SoftPLC runtime. It has one Ethernet interface. Application Control panel for free-programmable control units for HVAC systems or other technologies Terminal for receptions and rough environments overview and control of remote technologies Function Terminal HT200 displays a HT101 (SoftPLC) menu or textual or graphical definiton from Merbon IDE in a Merbon Visual application. All devices connected to HT200 must communicate with the same protocol (Merbon SSCP or SoftPLC), it is not possible to mix Merbon and SoftPLC controllers in a single menu structure. Controllers with SoftPLC runtime can be controlled only by textual definition. Graphical definition is available only for controllers with Merbon runtime. The controller hosts an embedded Linux operating system which boots up the Merbon Visual application. The PLCs communicate over the Ethernet interface. The menu definition is created in Merbon IDE (for the mark... controllers with Merbon runtime), or RcWare HMI Editor (controllers with SoftPLC runtime). Objects such as Value setting, Alarm, and Time schedule have predefined functionality, and thus it is only necessary to set addresses, assign data points, and complete user texts for the configuration. The application displays 9 rows at a time. The display text length on row is variable according to used symbols. As it is mentioned before, controllers with Merbon runtime can be controlled by textual menu, graphical menu or combination of both of them. domat HT200 02/2018 Subject to technical changes. 1

The device is installed using four metal clamps into an aperture in panel door or any suitable box. The aperture dimensions are 192 x 138 mm. Technical data Power 24 V ±10 % DC; 7 W (power supply is not included in scope of delivery; it is recommended to use separate power supply only for this device) Communication LCD display Number of connections HW SW Front panel dimensions Aperture dimensions 1x Ethernet 10/100BaseT RJ45, 2 LED (link, data) integrated in the connector touch screen LCD display 7, 800x480 px., LED backlight capacitive max 10 connections to controllers ARM Cortex A8 600 MHz, 256 MB FLASH, 256 MB DD3 DRAM Merbon HMI editor (version 2.2.0.0 ER2 and later) Merbon IDE (verzion 2.3.0.3 ER3 and later) RcWare HMI editor (version 0.9.15.512 and later) 202x149x39 mm; see schema below 192x138 mm; see schema below Protection degree IP65 (EN 60529) Recommended wire diameter 0,35-1,5 mm 2 Ambient temperature Storage conditions Vibration Standards conformity EU legislation 0 50 C; 10 90 % relative humidity; non-condensing gases and chemically non-aggressive conditions -20 60 C; 10 90 % relative humidity; non-condensing gases and chemically non-aggressive conditions 1G (5 500 Hz); peak acceleration 19G (duration 11 ms) EMC EN 61000-6-2 ed.3:2005, EN 55022 ed.3:2010 EN 60950-1 ed.2:2006 + A11:2009 + A12:2011 + A1:2010 + A2:2014 EN 50581:2012 Council Directive 2006/95/EC, health and low voltage equipment safety Council Directive 2004/108/EC, electromagnetic compatibility Council Directive 2011/65/EC, certain hazardous substances in electrical and electronic equipment Terminals 2 02/2018 Subject to technical changes. domat HT200

Terminals and connectors: + power - power FG optional connection for shielding Ethernet network interface domat HT200 02/2018 Subject to technical changes. 3

Dimensions Installation aperture: 4 02/2018 Subject to technical changes. domat HT200

Dimensions are in mm. Configuration The Merbon Visual definition is uploaded in terminal through Merbon IDE / RcWare HMI Editor or through web interface. Other settings could be configure through service web. The access to the service menu is possible from display or remotely over a web browser. RcWare HMI Editor Create the HT101 menu definition. The principles of creation menu are described in the LCD menu manual: http://domat-int.com/en/downloads/technicaldocumentation, RcWare SoftPLC Touch Screen Editor. Note: The connection parameters to a particular PLC must be correctly set. The terminal needs to know from which PLC the variables should be read. The connection settings is defined in File -> Variables Manager -> select a connection and Show advanced tools -> Connections -> Update / Edit Connection. After uploading the list of variables in the HMI project, the connection must be set as Remote Connection and correct communication parameters must be entered. The changes must be confirmed by the Apply changes button. Example: domat HT200 02/2018 Subject to technical changes. 5

The whole definition can be finally uploaded through File -> Upload menu definition to HT100/101. The editor creates a.txt definition file and uploads it to the device using FTP protocol. The correct IP address, user and password for FTP must be set (see below). As an alternative, it is possible to File -> Export menu definition for HT100/101 and create.txt definition file which can be uploaded through the HT200 web pages. After uploading menu definition the device must be restarted for the changes to apply. Merbon IDE HMI editor The process of creation a menu and uploading menu definition are described in Merbon IDE help in chapter HMI. Service web The HT200 service web can be accessed over a web browser on the device IP address (the browser PC must be in the same network). Service menu is accessible directly through the display. For access from display, swipe from right side of the monitor and after login select the settings icon. The menu is browsed by swiping up and down. Only the user with administrator rights can access this menu. Default username/password combination is admin/rw. To access the service web, enter the password (see below). The password can be changed in Device management. In Settings there is network and language configuration. It is possible to upload/download the menu definition and upload new version of HT200 application from web browser only. Display calibration It is possible to calibrate the display directly in the service web (either from the device or remotely from web). Do not use the calibration if not necessary. During calibration do not switch off the device and touch the five crosses which display sequentially. Communication The default network settings are: IP address : 192.168.1.99 subnet mask : 255.255.255.0 default gateway: 192.168.1.1 Password for service web: rw Text menu: Default user for service menu: admin Default password for service menu: rw Graphic template: Default user for service menu: Admin Default password for service menu: admin User for FTP: root 6 02/2018 Subject to technical changes. domat HT200

Password for FTP: root99 User for SSCP: admin Password for SSCP: rw Notice: Do not forget to note the new network settings after change! RoHS notice Safety note The device contains a non-rechargeable battery which backups the real-time clock and part of the memory. After the device is not operable, please return it to the manufacturer or dispose of it in compliance with local regulations. The device is designed for monitoring and control of heating, ventilation, and air conditioning systems. It must not be used for protection of persons against health risks or death, as a safety element, or in applications where its failure could lead to physical or property damage or environmental damage. All risks related to device operation must be considered together with design, installation, and operation of the entire control system which the device is part of. domat HT200 02/2018 Subject to technical changes. 7

Changes in versions 06/2016 First datasheet version. 10/2016 Change of power supply technical parameters. 11/2017 Added safety note. 12/2017 Information about new application Merbon Visual Information about new username/password combinations Added information about graphical menu definition 02/2018 Added password for graphic template. 8 02/2018 Subject to technical changes. domat HT200