SOLAIR Portable. Airborne Particle Counters 2017/11/09

Similar documents
Handheld P A R T I C L E C O U N T E R S 2017/11/10

Handheld P A R T I C L E C O U N T E R S

Handheld P A R T I C L E C O U N T E R S

CI-150 Series. Airborne Particle Counters

A smart system with an easy touch APC SmartTouch. Airborne Particle Counter

Ease of Use. Data at Your Fingertips LMS PHARMA

SOLAIR 3350/5350 Gen E Airborne Particle Counters Operating Manual

FacilityPro Environmental Monitoring Systems Data Processing and System Control

TSI AEROTRAK REMOTE WITH PUMP PARTICLE COUNTERS INSTALLATION CONSIDERATIONS

SPECIFICATIONS HAND HELD PARTICLE COUNTER KC Higashimotomachi, Kokubunji, Tokyo , Japan

Environmental Monitoring Systems for critical applications

Understanding Particle Counter Technology and the risks of data integrity of particle counts. by Jason Kelly

Additel 760 Automatic Handheld Pressure Calibrator

SPECIFICATIONS HAND HELD PARTICLE COUNTER KC Higashimotomachi, Kokubunji, Tokyo , Japan

Additel 760 Automatic Handheld Pressure Calibrator Selection Guide

Additel 760 Automatic Handheld Pressure Calibrator

Additel 760 Automatic Handheld Pressure Calibrator Selection Guide

ApexPortable OPERATING MANUAL. ApexP3, ApexP5

Handheld Laser Particle Counter. Model: P311. Operation Manual. Ver: 1.50 AIRY TECHNOLOGY INC

REGULATORY COMPLIANCE. Each device complies with the EMC Directive 2004/108/EC and is CE marked

DustTrak Presentation

Pharmabilities EXCELLENCE IN ENVIRONMENTAL MONITORING SINCE 1972

Air data test indicator Model CPA2501

Ranger Simplifying Even the Most Complex Industrial Applications. Compact Bench Scales. Standard Features Include:

CHANGES TO THE STANDARD FOR ISO ISO Cleanrooms and Associated Controlled Environments

DUSTTRAK II AEROSOL MONITORS MODELS 8530, 8530EP AND 8532

USER MANUAL Video Particle Counter with built in Camera Model VPC300

REMOTE 3104P, 5104P Airborne Particle Counter Operating Manual

Fluke 983. Users Manual. Particle Counter. 99 Washington Street Melrose, MA Phone Toll Free

PRODUCT INFORMATION Model 1000XP Wide Range Particle Spectrometer (WPS )

Airborne Particle Counter

USER GUIDE. Video Particle Counter with built in Camera. Model VPC300

Ranger Simplifying Even the Most Complex Industrial Applications. Compact Bench Scales. Standard Features Include:

HIAC Liquid Particle Counting System. Easily configurable for maximum flexibility

AEROTRAK PORTABLE AIRBORNE PARTICLE COUNTER MODEL 9310/9350/9510/9550/9500 QUICK START GUIDE

Particle size. Spraytec. Accurate particle sizing of aerosols and sprays. detailed specification sheets from

HIAC Liquid Particle Counting System. Easily configurable for maximum flexibility

For further information please contact us: phone +49 (0) fax +49 (0)

AEROTRAK HANDHELD AIRBORNE PARTICLE COUNTER MODEL 9306 QUICK START GUIDE

USER GUIDE. Video Particle Counter with built in Camera. Model VPC300

DMT PERFORMING UNDER PRESSURE DMT. Applications. Special features. Description 1/9

Microplate Absorbance Reader Labtech LT-4500

Component List. Standard. Optional Extras. Consumables ITEM MODEL QTY. Main Unit Power Cord - 1

MET ONE HHPC+ Series Handheld Particle Counters. Simple Fast MET ONE MET ONE

Easidew Portable Hygrometer

The Perfect Fit for Over 40 Years

Vibracord FX. The perfect equipment for your. measurement. Vibracord FX in aluminum case. Frequency response: Hz Hz

Your Eye Inside. VIDEO BORESCOPES Made in USA. The next generation of fully-portable, articulating videoscopes!

AEROTRAK Portable Airborne Particle Counter Model 9110

Cleanroom Certification Report

Vibracord FX. The perfect equipment for your. measurement. Vibracord FX in aluminum case. Frequency response: Hz Hz

FX 3300 Air Permeability Tester III Scope

DMT340 Series Dewpoint and Temperature Transmitters for Very Dry Conditions

Compressed air quality meas. according to ISO 8573 Residual oil content - particles - moisture

ApexRemote Airborne Particle Counter Operating Manual

FacilityPro Processors

SPRAYTEC ACCURATE PARTICLE SIZING FOR AEROSOLS AND SPRAYS PARTICLE SIZE

-Direct.com FG-3000 Digital Force Gauge Operation Manual

Digital pressure gauge Data Sheet: DMM2.431.R1.EN

DL1000 DURABILITY & LUBRICITY TEST SYSTEM

Users Manual. Airborne Particle Counter

Continuous Inkjet Videojet 1620 and 1650 High Resolution Micro Printers

TRX II. Portable documenting calibrator

We Build Confidence...

F&J SPECIALTY PRODUCTS, INC. The Nucleus of Quality Air Monitoring Programs

ProcessCalibrator Model CPH6000

NOVO-GLOSS. Flex 60. Operating Instructions. English

Thermal Shake Touch heat. cool. mix. repeat.

Mass Flow Meters, Controllers and Manifolds

! Ranges from -45º to 650ºC. ! Rapid heating, cooling and settling. ! Switch test, ramp, step and preset functions

Gloss. micro-gloss. Efficient gloss measurement makes your QC faster. In the lab, in production, at the customer s...

Your Eye Inside VIDEO BORESCOPES. The next generation of fully-portable, articulating videoscopes!

Best in class leak detector for high reliability testing in various applications, using helium and hydrogen

User Manual. cmt-iv5 Startup Guide

Product Brochure. DataVU. Paperless Recorders.

Component List. Standard. Optional Extras. Consumables ITEM MODEL QTY. Main Unit Power Cord (with NEMA plug) - 1

ElectroPress JPSeries 4 High rigidity & quality servo-press for Assembly Automation

Inkjet Printer UX Series PREMIUM CLASS. Coding Solutions by Hitachi

Product Data Sheet UniCoatPro LF Liquid-Fuel HVOF Controller Platform

Portable low-pressure controller Model CPC2000

Dust Monitors: Optical Particle Counters: Differential Pressure Recorders: 81

DPL4000 Portable Low Range Dew Point Analyzer

ETP-1.0 en January Operation and Service Manual (English) Operation and Service Manual (English) ETP-1.0 en January 2009

Avoid experiments in monitoring important parameters. Measuring instruments and solutions for the pharmaceutical, medical and healthcare industries

FG-3000 Digital Force Gauge Operation Manual

AEROTRAK PORTABLE AIRBORNE PARTICLE COUNTER MODEL 9110 OPERATION MANUAL

Cloud Human Machine Interface SERIES

Domino G-Series i-tech thermal ink jet printers

Retired. HP TFT7600 Rackmount Keyboard and Monitor (TFT7600 RKM) Overview

SHIMPO INSTRUMENTS. FG-7000T Digital Torque Gauge Operation Manual

DMT345 and DMT346 Dewpoint Transmitters

DCT7088 Portable Digital Correlation Transit Time Flowmeter

Reliable Environmental Monitoring Systems by Design

Quattro Flow. Air Velocity Analyzers. Mobile Multipoint Evaluation CAMBRIDGE ACCUSENSE, INC.

Gloss. micro-gloss. Efficient gloss measurement makes your QC faster. In the lab, in production, at the customer s...

HMT330 Series Humidity and Temperature Transmitters for Industrial Applications

PTU300 Combined Pressure, Humidity and Temperature Transmitter

0.1 Slow Monitoring and Recording System

Industrial pressure controller Model CPC4000

FG-3000R Digital Force Gauge Operation Manual

Transcription:

SOLAIR Portable Airborne Particle Counters 2017/11/09

SOLAIRPortable 1100LD 1.0 CFM - Airborne Particle Counter The Lighthouse SOLAIR 1100LD (Laser Diode) leads the industry as the first of it s kind portable particle counter with 0.10 micron sensitivity and 1.0 CFM (28.3 LPM) flow rate using laser diode technology. Conventional HeNe (Helium Neon) particle counters require frequent cleaning, periodic Laser tube replacement and suffer low concentration limits. The SOLAIR 1100LD is designed to operate in ISO Class 1 to Class 7 cleanrooms without concerns of it degrading its environment or exceeding concentration limits. The SOLAIR 1100LD uses an optics and photodiode system designed to reduce or eliminate the temperature issues associated with high power laser diode sensors. The thermally-controlled exhaust system and HEPA filter option prevent any external contamination. Weighing just 23.55 lbs (10.68 kg) with the Li-Ion battery option, the SOLAIR 1100LD is the smallest, lightest and coolest running 0.10 micron, 1.0 CFM portable particle counter on the market. The easy to use icon-driven interface with multiple languages simplifies training and SOP writing. Its Cleanroom Standard report wizards make the SOLAIR 1100LD the preferred cleanroom certification tool and eliminate the need for complex UCL calculations. Its flexible communication and data logging capabilities enable the SOLAIR 1100LD to connect to Ethernet or RS-485 networks, connect point-to-point to a PC using USB or securely export its data to a USB Flash Drive. The SOLAIR 1100LD can be used as a portable instrument or easily integrated into a facility monitoring system. 0.1-1.0 µm sensitivity 1.0 CFM (28.3 LPM) Flow Rate Up to 8 channels of simultaneous count data 21 CFR Part 11 Compliant Secure USB flash transfer Laser Diode Sensor Technology 5.7 inch color touch screen display Ethernet / RS485 / Modbus, 4x 4-20mA analog outputs Multiple-language Support: English, French, German, Italian, Spanish, Chinese, Russian, Japanese, Korean User Friendly Configuration 2 Year Warranty User Friendly Interface Easy-to-Read Display Low Cost of Ownership Alphanumeric Location Labels Multiple Cleanroom Standard Reports via Printer

SOLAIRPortable 3100/5100 1.0 CFM - Airborne Particle Counters THE SOLAIR 3100 and SOLAIR 5100 portable airborne particle counters incorporate our Extreme Life Laser Diode Technology sensor to produce the industry s longest laser diode life of 20+ years MTTF (based on continuous 24/7 operation). Using a new, lighter extended-life battery and external AC adapter, the SOLAIRs are even more portable.the SOLAIR features one of the industry s best User Interfaces (UI) to configure and operate the instrument with intuitive ICON-driven screens and menus that are simple, easy to learn and use. The SOLAIR can store up to 3,000 records of particle count data from up to 8 particle channels and the configurable recipe database can store up to 50 recipes for sampling and reports. All data can be quickly and reliably transferred to a computer, a Facility Monitoring System or a Building Automation System. Secure data transfer (per 21 CFR Part 11) to a USB Flash Drive can be accomplished by using the Lighthouse Secure Data transfer feature and LMS Express or Express RT software to read it. Flexible communications with these instruments is made possible by the integrated Ethernet, RS-485, USB and USB Flash Drive interfaces. SOLAIRs are designed, manufactured and calibrated to ISO 21501-4 to ensure particle counting accuracy. User Friendly Interface with Multiple Languages 2 year Warranty Easy Integration to External Systems with OPC Server Applications Cleanroom Monitoring Facility Certification Testing Trend Analysis Tool and Equipment Testing Multi-Point Facility Monitoring (with 6 or 32 port Manifold System) Compressed Gas Monitoring (with High Pressure Controller) SOLAIR 3100: 0.3µm to 25.0µm SOLAIR 5100: 0.5µm to 25.0µm 1.0 CFM (28.3 LPM) Flow Rate Simultaneous Display of up to 8 Particle Sizes 21 CFR Part 11 Compliant Secure Data Transfer via USB Flash Drive Extreme Life Laser Diode Technology >20-year MTTF Laser Lifespan Designed for ISO 21501-4 Compliance: Unit-to-Unit Accuracy & Repeatability Assured Multiple Communication Interfaces - USB, RS-485, Ethernet and USB Flash Drive 5.7-inch Color TFT Touch Screen Display User-Definable Printouts Multiple-language Support: English, French, German, Italian, Spanish, Chinese, Russian, Japanese, Korean

SOLAIRPortable 3200/5200 50 LPM - Airborne Particle Counters THE SOLAIR 3200 and SOLAIR 5200 portable airborne particle counters incorporate our Extreme Life Laser Diode Technology sensor to produce the industry s longest laser diode life of 20+ years MTTF (based on continuous 24/7 operation). SOLAIRs incorporate one of the industry s best User Interfaces (UI) to configure and operate the instrument. The intuitive ICON-driven screens and menus are easy to learn and simple to use. SOLAIRs can store up to 3,000 records of particle count data from up to 8 particle channels and the configurable recipe database can store up to 50 recipes for sampling and reports. All data can be quickly and reliably transferred to a computer, a Facility Monitoring System or Building Automation System.Secure data transfer (per 21 CFR Part 11) to a USB Flash Drive can be accomplished by using the Lighthouse Secure Data transfer feature and LMS Express or Express RT software to read it. Flexible communication with these instruments is made possible by the integrated Ethernet, RS-485, USB and USB Flash Drive interfaces. SOLAIRs are designed, manufactured and calibrated to ISO 21501-4 to ensure particle counting accuracy. User Friendly Interface with Multiple Languages 2 year Warranty Easy Integration to External Systems with OPC Server Applications Cleanroom Monitoring Facility Certification Testing Trend Analysis Tool and Equipment Testing Compressed Gas Monitoring (with High Pressure Controller) SOLAIR 3200: 0.3µm to 25.0µm SOLAIR 5200: 0.5µm to 25.0µm 50 LPM or 2.0 CFM (56.6 LPM) Flow Rate Simultaneous Display of up to 8 Particle Sizes 21 CFR Part 11 Compliant Secure Data Transfer via USB Flash Drive Extreme Life Laser Diode Technology >20-year MTTF Laser Lifespan Designed for ISO 21501-4 Compliance: Unit-to-Unit Accuracy & Repeatability Assured Multiple Communication Interfaces - USB, RS-485, Ethernet and USB Flash Drive 5.7-inch Color TFT Touch Screen Display User-Definable Printouts Multiple-language Support: English, French, German, Italian, Spanish, Chinese, Russian, Japanese, Korean

SOLAIRPortable 3350/5350 100 LPM - Airborne Particle Counters WITH fast, reliable sampling of one cubic meter of air in only ten minutes, the SOLAIR 3350 and SOLAIR 5350 portable airborne particle counters offer faster cleanroom qualification than 1 and 2 CFM counters and at sensitivities of 0.3 and 0.5 microns, respectively. SOLAIRs incorporate our Extreme Life Laser Diode Technology sensor to produce the industry s longest laser diode life of 20+ years MTTF (based on continuous 24/7 operation). The SOLAIR 3350 is the industry s only 100 LPM 0.3 micron portable designed for continuous use. SOLAIRs use the industry s best UI (User Interface) to configure and operate the instrument. The intuitive ICON-driven screens and menus are easy to learn and use, which simplifies SOP writing, and support multiple languages. SOLAIRs can store up to 3,000 records of particle count data from up to 8 particle channels and the configurable recipe database can store up to 50 recipes for sampling and reports. All data can be quickly and reliably transferred to a computer, a Facility Monitoring System or Building Automation System.Secure data transfer (per 21 CFR Part 11) to a USB Flash Drive can be accomplished by using the Lighthouse Secure Data transfer feature and LMS Express or Express RT software. Flexible communication with these instruments is made possible by the integrated Ethernet, RS-485, USB and USB Flash Drive interfaces. SOLAIRs are designed, manufactured and calibrated to ISO21501-4 to ensure particle counting accuracy. SOLAIR 3350: 0.3-25.0µm, 0.3µm @ 100 LPM SOLAIR 5350: 0.5-25.0µm, 0.5µm @ 100 LPM Samples 1 Cubic Meter in 10 Minutes @ 100 LPM Simultaneous Display of up to 8 Particle Sizes 21 CFR Part 11 Compliant Secure Data Transfer via USB Flash Drive Extreme Life Laser Diode Technology >20 Years MTTF Laser Lifespan Designed for ISO 21501-4 Compliance: Unit-to-Unit Accuracy & Repeatability Assured Multiple Communication Interfaces - USB, RS-485, Ethernet and USB Flash Drive 5.7-inch Color TFT Touch Screen Display User-Definable Printouts Multiple-language Support: English, French, German, Italian, Spanish, Chinese, Russian, Japanese, Korean Reduced Sample Time of 1 Cubic Meter in 10 minutes User Friendly Interface with Multiple Languages 2 year Warranty Easy Integration to External Systems with OPC Server Applications Cleanroom Monitoring Facility Certification Testing Trend Analysis Tool and Equipment Testing Compressed Gas Monitoring (with High Pressure Controller)

SOLAIRBoulderCounter 1.0 CFM - Airborne Particle Counters THE Lighthouse BOULDER COUNTER portable airborne particle counters incorporate our Extreme Life Laser Diode Technology sensor to produce the industry s longest laser diode life of 20+ years MTTF (based on continuous 24/7 operation). Designed to use a new, lighter extended-life battery and external AC adapter, the BOULDER COUNTER is even more portable. BOULDER COUNTERs feature one of the industry s best User Interfaces (UI) to configure and operate the instrument with intuitive ICON-driven screens and menus that are quick to document for SOPs, easy to learn and simple to use. BOULDER COUNTERs can store up to 3,000 records of particle count data from up to 6 particle channels and the configurable recipe database can store up to 50 recipes for sampling and reports. All data can be quickly and reliably transferred to a computer, a Facility Monitoring System or a Building Automation System. Secure data transfer (per 21 CFR Part 11) to a USB Flash Drive can be accomplished by using the Lighthouse Secure Data transfer feature and LMS Express or Express RT software. Flexible communications with these instruments is made possible by the integrated Ethernet, RS-485, USB and USB Flash Drive interfaces. BOULDER COUNTERs are designed, manufactured and calibrated to standards that ensure particle counting accuracy and repeatability. 5.0µm to 100.0µm sensitivity 1.0 CFM (28.3 LPM) Flow Rate Simultaneous Display of up to 6 Particle Sizes 21 CFR Part 11 Compliant Secure Data Transfer via USB Flash Drive Extreme Life Laser Diode Technology >20-year MTTF Laser Lifespan Multiple Communication Interfaces - USB, RS-485, Ethernet and USB Flash Drive 5.7-inch Color TFT Touch Screen Display User-Definable Printouts Multiple-language Support: English, French, German, Italian, Spanish, Chinese, Russian, Japanese, Korean User Friendly Interface with Multiple Languages 2 year Warranty Easy Integration to External Systems with OPC Server Automotive Manufacturing Coating Processes Paint Booth Aerospace Flight and Space Hardware Manufacturing Flat Panel Display Manufacturing Medical Device Manufacturing

Product Selection Guide Size Range Channel Sizes Flow Rate Counting Efficiency Concentration Limits 1100LD 0.10-1.0 µm Optional ranges up to 5.0 µm Standard: 0.10, 0.15, 0.2, 0.25, 0.3, 0.5, 0.7, 1.0 µm 1.0 CFM (28.3 LPM) 50% @ 0.1 um: 100% @ sizes > 0.15 µm per JIS B 9921 and ISO 21501-4 500,000 particles/ft3 (17,150,000 / m3) @ 5% coincidence loss 3100 5100 0.3-25.0 µm Standard: 0.3, 0.5, 1.0, 3.0, 5.0, 10.0 µm Standard: 0.3, 0.5, 1.0, 5.0, 10.0, 25.0 µm 8-Channel: 0.3, 0.5, 0.7, 1.0, 3.0, 5.0, 7.0, 10.0 µm 1.0 CFM (28.3 LPM) 50% @ 0.3 µm; 100% @ sizes > 0.45 µm 1,000,000 particles/ft3 (35,300,000/m3) @ 10% coincidence loss 0.5-25.0 µm Standard: 0.5, 0.7, 1.0, 3.0, 5.0, 10.0 µm Standard: 0.5, 1.0, 3.0, 5.0, 10.0, 25.0 µm 8-Channel: 0.5, 0.7, 1.0, 2.0, 3.0, 5.0, 7.0, 10.0 µm 1.0 CFM (28.3 LPM) 50% @ 0.5 um; 100% @ sizes > 0.75 µm 1,000,000 particles/ft3 (35,300,000/m3) @ 10% coincidence loss Light Source Dimensions Laser Diode 14.65"Lx8.0"Wx10.4"H (37x20x26cm) Extreme Life Laser Diode Technology with > 20 year MTTF 9.5"Lx8.0"Wx10.2"H (24.13x20.32x25.9cm) Extreme Life Laser Diode Technology with > 20 year MTTF 9.5"Lx8.0"Wx10.2"H (24.13x20.32x25.9cm) Weight With battery: 23.55 lbs (10.68 kg) Without battery: 20.45 lbs (9.28 kg) With battery: 13.40 lbs (6.08 kg) Without battery: 12.00 lbs (5.44 kg) With battery: 13.40 lbs (6.08 kg) Without battery: 12.00 lbs (5.44 kg) 3200 5200 Size Range 0.3-25.0 um 0.5-25.0 um Channel Sizes Flow Rate Counting Efficiency Concentration Limits Light Source Dimensions Weight Standard: 0.3, 0.5, 1.0, 3.0, 5.0, 10.0 µm Standard: 0.3, 0.5, 1.0, 5.0, 10.0, 25.0 µm 8-Channel: 0.3, 0.5, 0.7, 1.0, 3.0, 5.0, 7.0, 10.0 µm 8-Channel Optional: 0.3, 0.5, 0.7, 1.0, 5.0, 7.0, 10.0, 25.0 µm 50 LPM 50% @ 0.3 µm; 100% @ sizes > 0.45 µm 700,000 particles/ft3 (24,710,000/m3) @ 10% coincidence loss Extreme Life Laser Diode Technology with > 20 year MTTF 14.65"Lx8.0"Wx10.4"H (37x20x26cm) With battery: 20.90 lbs (9.48 kg) Without battery: 17.80 lbs (8.07 kg) Standard: 0.5, 0.7, 1.0, 3.0, 5.0, 10.0 µm Standard: 0.5, 1.0, 3.0, 5.0, 10.0, 25.0 µm 8-Channel: 0.5, 0.7, 1.0, 2.0, 3.0, 5.0, 7.0, 10.0 µm 8-Channel Optional: 0.5, 1.0, 2.0, 3.0, 5.0, 7.0, 10.0, 25.0 µm 50 LPM 50% @ 0.5 um; 100% @ sizes > 0.75 µm 700,000 particles/ft3 (24,710,000/m3) @ 10% coincidence loss Extreme Life Laser Diode Technology with > 20 year MTTF 14.65"Lx8.0"Wx10.4"H (37x20x26cm) With battery: 20.90 lbs (9.48 kg) Without battery: 17.80 lbs (8.07 kg) 3350 5350 Boulder Counter Size Range Channel Sizes 0.3-25.0 µm Standard: 0.3, 0.5, 1.0, 3.0, 5.0, 10.0 µm Optional: 0.3, 0.5, 1.0, 5.0, 10.0, 25.0 µm 0.5-25.0 um Standard: 0.5, 0.7, 1.0, 3.0, 5.0, 10.0 µm Optional: 0.5, 1.0, 3.0, 5.0, 10.0, 25.0 µm 5.0-100.0 um Standard: 5.0, 10.0, 25.0, 40.0, 50.0, 100.0µm Flow Rate Counting Efficiency 100 LPM 50% @ 0.3 µm; 100% @ sizes > 0.45 µm 100 LPM 50% @ 0.5 µm; 100% @ sizes > 0.75 µm 28.3 LPM 50% @ 5.0 um Concentration Limits 400,000 particles/ft3 (14,120,000/m3) @ 10% coincidence loss 400,000 particles/ft3 (14,120,000/m3) @ 10% coincidence loss 500,000 particles/ft3 @ 5% coincidence loss Light Source Dimensions Extreme Life Laser Diode Technology with > 20 year MTTF 14.65"Lx8"Wx10.4"H (37x20x26cm) Extreme Life Laser Diode Technology with > 20 year MTTF 14.65"Lx8.0"Wx10.4"H (37x20x26cm) Extreme Life Laser Diode Technology with > 20 year MTTF 9.5"Lx8.0"Wx10.2"H (24.13x20.32x25.9cm) Weight With battery: 26.15 lbs (11.86 kg) Without battery: 23.05 lbs (10.46 kg) With battery: 26.15 lbs (11.86 kg) W ithout battery: 23.05 lbs (10.46 kg) With battery: 13.40 lbs (6.08 kg) Without battery: 12.00 lbs (5.44 kg) Zero Count Level Calibration Count Modes Data Storage Communication Modes Supporting Software Environmental Sensors Touch Screen Display Reports Alarms Sample Output Vacuum Source Enclosure Power Battery Languages <1 count / 5 minutes (per JIS B 9921) Meets ISO 21501-4 calibration using NIST traceable PSL spheres, DMA and condensation Particle Counter Automatic, manual, beep, concentration, cumulative/differential 3,000 sample records, rotating buffer (includes particle and environmental data, location and time) USB, Ethernet, RS-485, Secure Data Transfer to and Storage on USB Flash Drive LMS Express, LMS Express RT, LMS Pharma Optional (up to 4) temperature/relative humidity, air velocity, differential pressure or others 5.7 - inch (14.47 cm) color TFT touch screen display Pass/fail report wizard for ISO-14644-1, EU GMP Annex 1, and FS-209E report formats Integrated alarm buzzer and external alarm connector. Alarms on counts, low battery, sensor failure 1100LD Model: Internally filtered to 100% @ 0.1 µm, optional HEPA filtration for cooling system exhause. All other models: Internally filtered to HEPA standards (>99.97% @ 0.3 µm) Internal closed-loop controlled pump. Allows the use of 3/8" ID sample tubing of up to 12 meters (40 feet) @ 50 & 100LPM Stainless Steel 100-250 VAC, 47-63 HZ Optional Li-Ion, removable & rechargeable (typical recharge time 7.5 hours) English (U.S.), French, German, Italian, Spanish, Chinese, Russian, Japanese, Korean

SOLAIRPortable Airborne Particle Counters Lighthouse Worldwide Solutions Operations Corporate Headquarters 47300 Kato Road Fremont, CA 94538 USA Tel: +1 510 438 0500 Fax: +1 510 438 3840 Manufacturing Operations 1221 Disk Drive Medford, OR 97501 USA Tel: +1 541 770 5905 Fax:+1 541 770 2033 Benelux Operations Van Heemstraweg 19-A 6657 KD Boven-Leeuwen The Netherlands Tel: +31 487 560811 Fax: +31 487 560013 EMEA Operations Mimar Sinan Mh. Cavusbasi Cd. Ozge Sk. Zin D Business Center NO: 1/26 Cekmekoy/Istanbul Turkey Tel: +90 216 640 0 597 Fax: +90 216 640 0 598 Thailand Operations 9/13 Moo 5, Phaholyothin Rd. T. Klongneung, A. Klongluang Pathumthani, 12120 Thailand Tel: +662 902 2722-3 Fax: +662 902 2724 Malaysia Operations No. 18-32-A1 & A2 Gurney Tower, Persiaran Gurney Georgetown, 10250 Penang Malaysia Tel: +604 370 1229 Fax: +604 370 1209 D I S T R I B U T E D B Y : Lighthouse Worldwide Solutions Benelux BV Van Heemstraweg 19A 6657 KD Boven-Leeuwen The Netherlands Tel: +31(0)487 560811 E-mail: benelux@golighthouse.com Website: www.golighthouse.nl MADE IN USA www.golighthouse.com