voltage surge protectors low voltage type 1 (class I / B) voltage surge protectors low voltage type 2 (class II / C) Distribution board protection

Similar documents
Modular surge protective devices

Multifunction

mcbs, EQUIPMENT NEW PRODUCTS 2014 Voltage surge protectors & other control and signalling devices Time & light sensitive switches

Surge Protection Devices Type 1+2

oltage surge rotectors low oltage

Using your PC to access a remote M90 via GSM

100% electricity. Power factor correction components

Overvoltage Protection Devices

DINALOG A 96 x 24. Programmable quasi-analogue bar graph meters. Technical characteristics DINALOG A 96 x 24

IO-DI16, IO-DI16-L I/O Expansion Modules

Modular surge protective devices (SPDs)

Modular surge protective devices (SPDs)

EX-RC1 Remote I/O Adapter

IO-DI8-RO8, IO-DI8-RO8-L I/O Expansion Modules 8 Inputs, 8 Outputs

Lightning and Surge Arresters

CARLO GAVAZZI Automation Components. Surge Protection Devices

Failure to comply with appropriate safety guidelines can cause severe injury or property damage.

Low voltage. Acti 9. the efficiency you deserve. Catalogue 03/2016

Surge Protection: Safety for Sewage Plants.

CARLO GAVAZZI. Automation Components. The quick-fit energy metering solutions

3 Digital, 3 Digital/Analog, 3 PT1000/NI1000 Inputs, 5 Relay, 1 pnp/npn Outputs

Vision OPLC. Technical Specifications. V T34 Technical Specifications

Modular surge protective devices (SPDs) Cat. Nos :

Component identification

3 Design of the electrical installation protection system

CONTA-ELECTRONICS. CONTA-PROTECT overvoltage protection

Overvoltage Protection Devices

PRF1 12.5r/PRF1 Master/ PRD1 25r/PRD1 Master Type 1 and 2 LV surge arresters

V E5B Snap-in I/O Module

Vision OPLC. General Description. Standard Kit Contents. Installation Guide Vision120. This guide provides basic information for Unitronics Vision120.

SURGE PROTECTIVE DEVICES

Failure to comply with appropriate safety guidelines can cause severe injury or property damage.

Overvoltage Protection Devices

Overvoltage Protection Devices

UniStream HMI Panel. CPU-for-Panel

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

Overvoltage Protection Devices

Vision OPLC V TR20/V350-J-TR20

DX 3 MCB A / 16 ka 80 A to 125 A (1,5 module per pole)

2 Principle of lightning protection

Type of surge arrester

V E62B Snap-in I/O Module

Medium Voltage Solutions For Water and Wastewater Treatment

Overvoltage Protection

Accessories - cable tie bases

Installation Guide V290 (Color) This guide provides basic information for Unitronics LCD color touchscreen models V C30B and V T40B.

ict contactors EN 61095, IEC 1095 Interference

Surge Protection Devices Ex9UE2

20.4VDC to 28.8VDC with less than 10% ripple Max. current consumption See Note 1 npn inputs

Surge Protective Device

VENTILATION. Short catalogue VENTILATION COMMON FEATURES.

Surge Protection Devices and Surge Protection Kit

Vision OPLC. V TR6 Technical Specifications. Technical Specifications.

100% electricity. Automatic transfer switch controllers ATL series

Screen 2.4" 3.5" Color Touch 4.3" Color Touch. RS232/485 Yes Yes Yes Yes Yes* USB device, mini-b Com Ports, separate order, user-installed

IO-DI8-RO4, IO-DI8-RO4-L I/O Expansion Modules 8 Inputs, 4 Outputs

Bulletin 1492 In-Panel I/O Wiring System Modules and Cables for Allen-Bradley Programmable Controllers Reduced Wiring Time, Accurate Connections

RB60 RANGE. Miniature circuit breakers

Industrial Ethernet from Hirschmann. WELCOME TO ATEX ZONE 1: SIMPLY A GOOD CONNECTION

Characteristics. High impact with draw wire (ICTA 3422) Use. Accessories for conduits (p. 754)

Technical features OVR Surge Protective Devices Type 1 & Type 1+2

C C CIRCUIT-BREAKERS Moulded-case (MCCB), general. 1. Introduction. 2. General description

SPM Series Plug-in Surge Protector Type 2/3 (Test Class II/III) Single & Three Phase Surge Arresters

Unitronics Devices and RS485 Table Of Contents

Switch Disconnectors, Main and EMERGENCY-STOP Switches

MCS IsoTM Busbar Modules for maximal safety. Finger proof even when load feeders removed MCS Standard Busbar Modules the economic solution Features

The right solution for every home

Miniature. Circuit Breakers. reliable solutions for protection of installations against over-current phenomenon. Advantages for you : Technical data :

Siemens AG KD Switch Disconnectors SENTRON. Edition December Answers for infrastructure and cities.

Electronic timer CT-AHS OFF-delayed with 2 c/o contacts Data sheet

UniStream CPU-for-Panel

Plug-in relays RH control relays Instantaneous (RHN) and latching (RHK)

1.2 Section ADAPTORS AND MULTI-OUTLET SOCKETS. Research. BLUELINE Series AZZURRA Series SICURA Series. To give you the best...always!

SPM Series Plug-in Surge Protection

V350-RA22 V350J-RA22.

EX-RC1 Remote I/O Adapter

TeSys contactors From 115 to 2750 A

/60 ETITEC A 15/ /60 ETITEC A 15/440 Al/Fe connection*

Motor protection relays

SNAP PAC Redundancy Option Kit

LED Driver Linear / area fixed output

Lightning and Surge Protection of Photovoltaic Installations. Leutron GmbH 2013 Leinfelden-Echterdingen, Germany

Surge Protection. tra Combinations. Surge Protection

Micro Contactor MA Series

Section 4 Ground-Fault Protection Devices

This guide provides basic information for Unitronics Models V230/260/280/290 (Non-color Screens).

TeSys IEC Contactors and Overload Relays

Vision OPLC V TR20

Issued February DATA SHEET 5SX2 MCB. Based on Siemens Industrial Control Catalog

SURGE PROTECTION LIGHTNING & EARTHING EQUIPMENT

Electronic timer CT-EAS ON-delayed and OFF-delayed with 1 c/o contact Data sheet

LED Driver Linear / area fixed output

Page 14-4 Page Page 14-4 SURGE PROTECTION DEVICES TYPE 2 VERSIONS WITH PLUG-IN CARTRIDGE 1P, 1P+N, 2P, 3P, 3P+N, 4P

Coordination of Surge protection devices

BS th Edition wiring regulations Furse overview

Lightning Current Equipotential Bonding SPDs

Micro800 Programmable Controllers

LIMANDA Handheld Enclosures Product Drawings Last Updated 6/5/2008

Miniature Circuit-Breaker IEC Series 8562

AThink future. Switch to green. Mini Panel Board. Cost-effective, space-saving board up to 400A.

Transcription:

voltage surge protectors low voltage type 1 (class I / B) voltage surge protectors low voltage type 2 (class II / C) 030 23 030 28 039 21 039 33 039 34 Type 1 voltage surge protectors (V.S.P.) for main distribution boards Conform to standards IEC 61643-1 and E 61643-11 3 different impulse discharge ratings For 230/400 VA Especially for use in installations at very high risk and/or with external lightning of the building Technical characteristics (p. 164-165) Cat.os Main board High lightning - H - Iimp = 50 ka For power installations Earthing system: TT, T, IT o plug-in module umber of Associated umber poles 1 030 00 1P gg type - max. 250 A 2 Increased lightning - E - Iimp = 25 ka For power installations Consist of a base and a plug-in replacement module provided with a status indicator Fitted with built-in thermal Equipped with auxiliary contacts for remote monitoring or bottom umber of Associated umber poles 1 030 22 3P gg type - max. 250 A 6 TC earthing system 1 030 23 4P gg type - max. 250 A 8 TT, TS earthing system Standard lightning - S - Iimp = 12.5 ka For all types of installations Equipped with status indicator: o plug-in module umber of Associated umber poles 1 039 10 (1) 1P 40 A - C curve 2 TT, T, IT earthing system Replacement modules for type 1 V.S.P. 1 030 28 For V.S.P. Cat.os 030 20/22/23 1 030 29 For V.S.P. Cat.o 039 23 (-PE module) Technical characteristics (p. 164-165) Type 2 voltage surge protectors (V.S.P.) for main boards, distribution boards and consumer units Conform to standards IEC 61643-1 and E 61643-11 3 different impulse discharge ratings For 230/400 VA Cat.os Main board High - H - Class I + II Imax = 70 ka Earthing systems: TT, T, IT Consist of a base and a plug-in replacement module provided with a status indicator Can be equipped with auxiliary contacts for remote monitoring purpose (p. 163) umber of Associated umber poles 1 039 20 (1) 1P 40A - C curve 1 1 039 21 (1) 2P 40A - C curve 2 1 039 22 (1) 3P 40A - C curve 3 1 039 23 (1) 4P 40A - C curve 4 Distribution board For electrical equipments located at more than 30 m from the main distribution board Consist of a base and a plug-in replacement module provided with a status indicator Can be equipped with auxiliary contacts for remote monitoring purpose (p. 163) Increased - E - Class II - Imax= 40 ka Earthing systems: TT, T, IT umber of Associated umber poles 1 039 30 (1) 1P 20A - C curve 1 1 039 31 (1) 2P 20A - C curve 2 1 039 32 (1) 3P 20A - C curve 3 1 039 33 (1) 4P 20A - C curve 4 Standard - S - Class II - Imax= 15 ka Earthing systems: TT, T umber of Associated umber poles 1 039 40 (1) 1P 20A - C curve 1 1 039 41 (1) 2P 20A - C curve 2 1 039 43 (1) 4P 20A - C curve 4 Replacement modules for type 2 V.S.P. 5 039 28 For V.S.P. Cat.os 039 20/21/22/23 5 039 34 For V.S.P. Cat.os 039 30/31/32/33 5 039 44 For V.S.P. Cat.os 039 40/41/43 5 039 39 For V.S.P. Cat.os 039 35/36/38 (old model voltage surge protector) Proximity (p. 542, 762 and 806) 162 (1) Associated : MCBs DX, DX-H, DX-L or equivalent ranges according to required breaking capacity (1) Associated : MCBs DX, DX-H, DX-L or equivalent ranges according to required breaking capacity

voltage surge protectors for telephone lines and accessories for low voltage V.S.P. voltage surge protectors 038 28 038 29 Technical characteristics (p. 164-165) Cat.os Voltage surge protector for telephone lines and data networks installations already equipped with low voltage V.S.P. on power lines (standard IEC 60364) For of: telephone, fax, modem, etc., connected to the incoming telephone line, against overvoltages of atmospheric origin Installed in a distribution cabinet, especially the ELV/ signal cabinet Cat.o 011 95 (please consult us), or terminal shield boxes 1 module (p. 187) Connected in series with the telephone line Provided with a status indicator Conform to standards E 61643-21 and IEC 61643-21 Imax: 10 ka and In: 5 ka (8/20) Un Up (V) (V) 1 038 28 1 038 29 Digital (signal lines, current loops) 48 100 Signalling auxiliaries for low voltage V.S.P. With changeover microswitch 2 A - 250 V± Mounted onto the base of the surge protector (except Cat.o 039 10) 1 039 56 For 2-pole module V.S.P. 1 039 57 For 3-pole module V.S.P. 1 039 58 For 4-pole module V.S.P. Decoupling inductors for low voltage V.S.P. Enable coordination between 2 V.S.P. in the same board, when minimum distance to insure proper V.S.P. coordination can not be respected For multipole voltage surge protectors, each conductor (including the neutral conductor) must be equipped with one decoupling inductor umber 1 039 62 Module for circuit 35 A - 500 V± 2 1 039 63 Module for circuit 63 A - 500 V± 4 Protection against lightning effects Lightning directly or indirectly generates the following effects: currents (damage to electrical and electronic equipment, interruption of operation) Protection against the effects of lightning is based essentially on: Passive (poor, good) designates the part of the provided by the structure and the configuration of the installation itself (neutral earthing system, area, level of equipotentiality, etc.) Voltage surge protectors and regulation Voltage surge protector enable: lighning 1 - Product standarts E 61643-11 and IEC 61643-1 E 61643-11 Type 1 (T1) Type 2 (T2) IEC 61643-1 Class I (T1) Class II (T2) VDE 0675-6 (1) Class B Class C Type of wave 10/350 μs 8/20 μs Main characteristics Iimp (10/350) In (8/20) In, Imax (1) German standard VDE replaced by European standard E 61643-11 2 - Installation standards: IEC 60364 (or equivalent electric national standards) According to articles 443 and 534, the use of VSPs is required in new or renovated buildings in the following cases: 5 ka 5 ka The use of VSPs is also strongly recommended in mountain areas, close to reaches of water or dominating structures (buildings, trees, etc.), in the cases of line end installations or installations located less than 50 m from buildings equipped with lightning conductors (2) When VSPs are present on the power circuit, it is strongly advised to install a VSP on the communication circuits (telephone or data lines ) (2) Lightning conductors: external of buildings against direct lightning impacts Choice of the level lightning Proximity (p. 542, 762 and 806) The annual average of stormy days (k) 0-1 2-4 5-9 10-19 20-39 40-59 60-79 80-99 100-139 140-200 + AQ2 areas : k > 25 IEC 60364 : V.S.P. mandatory for installations supplied with overhead low voltage lines and located in AQ2 areas 163

voltage surge protectors Technical characteristics Voltage surge protectors for power lines etworks: 230/400 VA Degree of : IP 20 Operating temperature: -10 C to +40 C Storage temperature: -20 C to +70 C Type 1 V.S.P. (class I) High lightning H Increased lightning E Standard lightning S Cat.os 030 00 030 22 030 23 039 10 eutral earthing system TT - T - IT TC TT - TS TT - T - IT Max. steady state voltage (Uc) 440 VA 350 VA 440 VA Max. discharge current L()-PE L-PE L- / -PE L()-PE Iimp (10/350) 50 ka 25 ka 25/100 ka 12.5 ka Itotal (10/350) - 75 ka 100 ka - ominal discharge current In (8/20) 50 ka 25 ka 25/100 ka 20 ka Protection level (Up) 1.5 kv 1.5 kv 1.8 kv Installation Voltage surge protectors cascading (multi-level ) Beyond the standards requirements: with a lightning conductor), are all situations that justify the installation of VSPs. However, the efficiency of against overvoltages cannot be optimally ensured with a single VSP. This is why Legrand recommends combining several VSPs in cascade with different levels, from the first panel as far as the device to be protected (proximity of sensitive devices). An installation will be all the more efficient if, beyond Class I and II VSPs, it comprises proximity VSPs (Class III) on sockets supplying sensitive devices (IT, electronic, etc.). Main board Without lightning conductor: type 2 V.S.P. H With lightning conductor: type 1 V.S.P.(mandatory) H, E or S Associated Max. terminal capacity gg 250 A max. gg 250 A max. 40 A C curve rigid conductor 35 mm 2 25 mm 2 18 mm 2 flexible conductor 50 mm 2 35 mm 2 25 mm 2 Secondary board Type 2 V.S.P. E or S Type 2 V.S.P. (class II) High (H) Increased (I) Voltage surge protectors for telephone lines Degree of : IP 20 Operating temperature: -10 C to +40 C Storage temperature: -20 C to +70 C Standard (S) Cat.os 039 20/21/22/23 039 30/31/32/33 039 40/41/43 eutral earthing system TT - T - IT TT - T - IT TT - T Max. steady state voltage (Uc) 440 VA 440 VA 320 VA Max. Iimp (10/350) 10 ka - - discharge current Imax (8/20) 70 ka 40 ka 15 ka ominal discharge current In (8/20) 20 ka 15 ka 5 ka Protection level (Up) at In at 5 ka 2 kv; 20 ka 1.5 kv; 5 ka 1.8 kv; 15 ka 1.3 kv; 5 ka 1.4 kv; 15 ka 1.2 kv; 5 ka UT 440 V 440 V 440 V Associated 40 A 20 A 20 A C curve Max. terminal capacity rigid conductor 25 mm 2 flexible conductor 16 mm 2 Proximity Mosaic or P = Céliane or similar Associated The supply circuit of the VSP must be protected against short-circuits and overloads by its associated disconnector (MCB) in accordance with discrimination rules. TT earthing systems, and V.S.P.: V.S.P. always installed downstream a Connection principles For the voltage surge protector to perform it s function as well as possible, it must be installed: phase-neutral terminal block and the PE or PE terminal block avoid the loops of conductors, fix the cables against metal conductive parts Phase or neutral terminal block Analog 038 28 Digital 038 29 Minimum voltage (Un) 170 V 48 V Protection level (Up) 260 V 100 V ominal current (In) 5 ka Max. terminal capacity flexible/rigid 0.5 to 2.5 mm 2 MCB (v.s.p. ) Voltage surge protector Max. distance: 0.5 m Cross section: 6 mm 2 (16 mm 2 with lightning conductors) Main terminal block protective conductors 164

voltage surge protectors Connection principles (continued) Main switch or MCB or time delay RCD (or S type RCD) 2 - Voltage surge protector in TT system HV / LV Protection Metering Distribution Board Transformer I n = type S or delayed PE L1 L2 L3 Protection of all poles To application Plug-in voltage surge protector Recommanded cross-sections for conductors linking voltage surge protectors by local regulations 3 - Voltage surge protector in IT system HV / LV Transformer Protection Metering Distribution Board Type 2 V.S.P. Cross section mm 2 H level 16 E level 10 S level 6 Type 1 V.S.P. Cross section mm 2 H level 16 E level 16 S level 16 L1 L2 L3 Minimum distances between voltage surge protectors Uc 440 V PE Upstream V.S.P. Downstream V.S.P. Distance (m) S level type 1 E (S) type 2 8 (10) H level type 2 S (P) type 2 8 (10) E level type 2 S (P) type 2 4 (6) S level type 2 P type 2 2 Installation for telephone lines Protection of a telephone line Upstream the communication distribution box Cat.o 038 28 Installation of V.S.P. in the same board with decoupling inductors When distances cannot be respected please use decoupling inductors (see Cat.os p. 163), installed as follows DT 110 V Analogue line Digital line L Cato. 039 62 or 63 1st level PE 2nd level (type 2 V.S.P.) 1 - Voltage surge protector in T system HV / LV Protection Metering Distribution Board Transformer PE L1 L2 L3 PE Downstream the communication distribution box - Analogue or digital DT 110 V - Digital DT 110 V Cat.o 038 28 Cat.o 038 29 Cat.o 038 29 Cat.o 038 29 Cat.o 038 29 Cat.o 038 29 Cat.o 038 29 Analogue telephone or fax Digital visioconference Digital telephone or fax Visio conference 165

domestic fuse carriers domestic cartridge fuses www.klinkmann.com 058 11 058 14 058 21 058 24 102 63 103 06 113 10 117 16 124 20 126 25 134 32 With label-holders With insulated carrier class II, padlockable Coupling via supply busbars Shielded terminals capacity 2 x 10 mm 2 Possibilty to signal indicator blown fuse Fuse not supplied Cat.os For domestic cylindrical cartridge fuses Conform to E 60269-1 and IEC 60269-1,3 Single pole For domestic Cartridge umber cartridges dimensions (mm) 10 058 10 10 A - 230 V± 8.5 x 23 1 10 058 11 16 A 10.3 x 25.8 1 10 058 12 20 A - 400 V± 8.5 x 31.5 1 10 058 13 25 A 10.3 x 31.5 1 10 058 14 32 A 10.3 x 38 1 Single pole + neutral 10 058 20 10 A - 230 V± 8.5 x 23 1 10 058 21 16 A 10.3 x 25.8 1 10 058 22 20 A - 400 V± 8.5 x 31.5 1 10 058 23 25 A 10.3 x 31.5 1 10 058 24 32 A 10.3 x 38 1 For miniature cylindrical cartridge fuses Conform to E 60127-6 and IEC 60127-6 To protect sensitive equipment: transformers, electronic equipment, etc. Single pole Cartridge Voltage umber dimensions (mm) 5 058 00 5 x 20 250 V± 1 Single pole + neutral 5 058 02 5 x 20 250 V± 1 Supply busbars (p. 249) Cat.os Miniature type 5 x 20 Instant reaction fuse - Ceramic body Conform to E/IEC 60127-2 High rupture capacity (A) For use with dimmers, Viking terminal blocks and emergency lightning units, transformers Voltage ± (Amps) (Volts) (Amps) 10 102 02 0.2 10 102 05 0.5 10 102 06 0.63 10 102 10 1 10 102 20 2 250 1500 10 102 30 3.15 10 102 50 5 10 102 63 6.3 10 102 96 (1) 10 250 500 Cylindrical 6.3 x 23 ± (Amps) (Volts) capacity section Indication Without With (Amps) (mm 2 ) indicator indicator Copper 10 103 06 (2) 6 230 6000 1.5 8.5 x 23 10 114 06 6 230 6000 10/100 113 10 114 10 10 1.5 10.3 x 25.8 10 116 10 (2) 10 230 6000 10 116 16 (2) 117 16 (2) 16 2.5 8.5 x 31.5 10/100 123 20 124 20 20 400 20000 2.5 10.3 x 31.5 10 126 16 16 10 126 20 20 400 20000 10 126 25 127 25 25 4 10.3 x 38 10/100 133 32 32 400 20000 10 134 32 32 6 eutral links 10 123 00 8 x 32 (previously 8.5 x 31.5) 10 133 00 10 x 38 Other cartridge fuses (p. 132) 166 These products are part of and distribution systems > See p. 142-143 Bold pack quantities: Minimum quantities to be ordered (1) Overrating not described by standarts (2) Conform to BS 1361 (1971)

isolating fuse carriers changeover switches 058 06 058 28 058 48 043 82 043 83 Cat.os For industrial cylindrical cartridge fuses type am or gg Conform to standard IEC 60269-2 Isolators conform to IEC 60947-3 Icc: - 20 ka with 8.5 x 31.5 cartridge fuse - 100 ka with 10 x 38 cartridge fuse Fuse not supplied (p. 166) Single pole Cartridge dimensions Voltage umber (mm) 10 058 06 (1) 8.5 x 32 400 V± 1 10 058 08 10 x 38 500 V± 1 Single pole + neutral 10 058 16 (1) 8.5 x 32 400 V± 1 10 058 18 10 x 38 500 V± 1 2-pole 5 058 26 (1) 8.5 x 32 400 V± 2 5 058 28 10 x 38 500 V± 2 3-pole 3 058 36 (1) 8.5 x 32 400 V± 3 3 058 38 10 x 38 500 V± 3 3-pole + neutral 2 058 46 (1) 8.5 x 32 400 V± 4 2 058 48 10 x 38 500 V± 4 Conform to standard IEC 60669-1 Breaking capacity AC 22 A according to IEC 60947-3 Cat.os Changeover switches Two-way - 250 V± ominal rating Connection umber (A) 10 043 82 20 1 Double two-way - 400 V± 5 043 83 20 2 Two-way with centre point - 250 V± 10 043 85 20 1 Double two-way with centre point - 400 V± 5 043 86 20 2 Accessories 10 057 90 Blow-out indicator 250 V± 1 057 96 Early break /O + /C contact auxiliary 5 A - 250 V± (0.5 module) Blow-out indicator 2 044 44 Sealable screw cover (4 separable poles) Sealable screw cover DX MCBs up to 125 A (p. 150-151) Supply busbars (p. 249) (1) Previously 8.5 x 31.5 167

pulse operated latching relays www.klinkmann.com 041 62 041 68 041 85 041 86 041 88 041 89 Cat.os Pulse operated latching relays Conform to standard E 60669-2-2 Maximum 2 auxiliary devices per latching relay Single pole - 16 A - 250 V± Control Type of Connection umber voltage contact 1 041 60 12 V 1 /O 1 1 041 61 24 V 1 /O 1 10 041 62 230 V 1 /O 1 2-pole - 16 A - 250 V± 1 041 65 24 V 2 /O 1 1 041 66 48 V 2 /O 1 1 041 68 230 V 2 /O 1 4-pole - 16 A - 400 V± Can be used for 3-pole assembly 1 041 71 230 V 4 /O 2 Cat.os Compensator module Used to control 230 V± latching relays via illuminated push-buttons without malfunctions Connects to the terminals of the pulse operated latching relay coil Compensation: - 1 compensator module for a total consumption of 3 to 6 ma (example: 6 to 11 illuminated push-buttons consuming 0.55 ma each) - 2 compensators modules for a total consumption of 6 to 9 ma (example: 12 to 17 illuminated pushbuttons with consuming 0.5 ma each) umber 1 041 89 Impedance compensator for 1 230 V± pulse operated latching relays Signalling auxiliary Fitted on left-hand side of latching relay (equipped or not with control auxiliary) Maximum 2 auxiliaries per latching relay Used to signal the status of the contacts on the associated product Auxiliary changeover switch umber I max. Voltage Contact 1 041 85 5 A 250 V± /C + /O 0.5 Control auxiliary Fitted on left-hand side of latching relay Maximum 1 control auxiliary per latching relay Compatible with signalling auxiliary Cat.o 041 85 Auxiliary device for centralized control from one single point umber 1 041 86 For latching relays 24 V± to 48 V± 0.5 1 041 87 For latching relays 230 V± 0.5 Auxiliary device for general centralized control 1 041 88 For simultanous control of different 1 groups of latching relays, already fitted with auxiliary device for centralised control 230 VA Cat.o 041 87 Auxiliary device for maintained contact 1 041 84 Allows the control of a latching relay 0.5 via one maintained contact (i.e. time switches) 168 These products are part of and distribution systems > See p. 142-143

pulse operated latching relays Schemas Signalling with auxiliary Cat.o 041 85 L Technical characteristics Power consumption Control voltage 12 VA 24 VA 48 VA 230 VA 230 VA ominal current 16 A 16 A 16 A 16 A 16 A Connection 1 /O 1 /O 2 /O 2 /O 1 /O 2 /O 4 /O umber 1 1 1 1 2 Cat.o 041 85 Holding 720 ma 330 ma 200 ma 35 ma 65 ma Inrush 2500 ma 1200 ma 700 ma 130 ma 250 ma Centralized control at one point using auxiliary devices Cat.os 041 87 and 041 88 L O OFF Cat.o 041 88 Cat.o 041 87 O Connection cross section mm 2 Type of conductors Cross section Rigid 1 x 6 mm 2 or 2 x 2.5 mm 2 Flexible 1 x 6 mm 2 or 2 x 2.5 mm 2 Flexible with single ferrule 6 mm 2 Flexible with double ferrule 1 x 6 mm 2 Cross reference list old range / new range OFF O Old range Cat.o ew range Cat.o Designation 040 00 041 60 16 A - 12 V - 1 /O L Cat.o 041 87 040 05 041 61 16 A - 24 V - 1 /O 040 15 041 62 16 A - 230 V - 1 /O 040 06 041 65 16 A - 24 V - 2 /O O 040 11 041 66 16 A - 48 V - 2 /O Cat.o 041 88 040 16 041 68 16 A - 230 V - 2 /O OFF O 040 19 041 71 16 A - 230 V - 4 /O 040 85 041 85 Auxiliary changeover switch 040 86 041 86 A - 48 VA Use only non illuminated push-buttons Control via maintained contact using auxiliary device Cat.o 041 84 and time switch L 040 87 041 87 A 040 89 041 89 Compensation module - 041 88-041 84 Auxiliary device for maintained contact Cat.o 041 84 169

power contactors from 16 A to 100 A www.klinkmann.com 041 16 041 23 041 24 041 31 041 47 040 78 Conform to IEC/E 61095 Space for power supply busbar on top (up to 25 A) Cat.os Power contactors with 24 V± coil 2-pole - 250 V± Type umber I max of contact 1 041 14 16 A 24V /C + /O 1 Cat.os Power contactors with 230 V± coil (continued) 2-pole - 250 V± Type umber I max of contact 1 041 29 25 A 230V 2 /C 1 1 041 16 25 A 24V 2 /O 1 4-pole - 400 V± 1 041 17 25 A 24V 4 /O 2 Power contactors with 24 V± coil and handle Manual override for test and repair function, carried out via the handle Permanent "O" or "OFF" without automatic reset 2-pole - 250 V± Type umber I max of contact 1 041 23 25 A 2 /O 1 1 040 94 (1) 40 A 24V 2 /O 2 1 040 73 (1) 63 A 2 /O 2 4-pole - 400 V± 1 041 24 25 A 4 /O 2 1 040 67 (1) 40 A 4 /O 3 1 040 74 (1) 24V 63 A 4 /O 3 Low noise power contactors with 230 V± coil 2-pole - 250 V± Type umber I max of contact 1 041 49 25 A 2 /O 1 230V Power contactors with 230 V± coil 2-pole - 250 V± Type umber I max of contact 4 041 26 16 A /C + /O 1 230V 10 041 58 25 A 230V 2 /O 1 1 040 95 63 A 230V 2 /O 2 4-pole - 400 V± 230V 5 041 31 25 A 4 /O 2 1 041 32 25 A 230V 4 /C 2 1 041 33 25 A 230V 2 /O + 2 /C 2 1 040 98 63 A 4 /O 3 1 040 99 100 A 230V 4 /O 6 Power contactors with 230 V± coil and handle Manual override for test and repair function, carried out via the handle Permanent "O" or "OFF" without automatic closing of the contactor 2-pole - 250 V± Type umber I max of contact 4 041 47 25 A 230V 2 /O 1 1 040 68 (1) 40 A 2 /O 2 1 040 75 (1) 63 A 2 /O 2 1 040 76 (1) 63 A 230V 2 /C 2 3-pole - 400 V± 1 040 69 (1) 40 A 3 /O 3 1 040 77 (1) 63 A 230V 3 /C 3 4-pole - 400 V± 2 041 48 25 A 4 /O 2 1 040 70 (1) 40 A 230V 4 /O 3 1 040 78 (1) 63 A 4 /O 3 1 040 79 63 A 4 /C 3 230V (1) Handle can be accessed once the blanking plate has been removed 170

power contactors from 16 A to 100 A (continued) power contactors from 16 A to 100 A 041 85 041 83 040 85 Technical characteristics 6 cycles - Operation: - 25 C to + 40 C - Storage: - 40 C to +70 C Protection of contactors against short-circuits conforming to MCB or gg fuse, rating: 16 A for 16 A rating 25 A for 25 A rating 40 A for 40 A rating 63 A for 63 A rating 100 A for 100 A rating Power contactors 16 A and 25 A Cat.os Signalling auxiliaries for contactors Auxiliary changeover switch Used to signal the position status of the contacts on the product to which it is connected For 1 module contactors 16 A to 25 A Maximum 2 auxiliary devices per contactor Fitted on left-hand side of contactor Changeover umber I max. Voltage switch 1 041 85 5 A 250 V± /C + /O 0.5 For 2 module contactors 25 A Maximum 2 auxiliary devices per contactor Fitted on left-hand side of contactor Changeover umber I max. Voltage switch 1 041 83 5 A 250 V± /C + /O 0.5 For 40 and 63 A contactors Maximum 1 auxiliary device per contactor Fitted on left-hand side of contactor Changeover umber I max. Voltage switch 1 040 85 5 A 250 V± /C + /O 0.5 For 100 A contactors Maximum 1 auxiliary device per contactor Fitted on right-hand side of contactor Changeover umber I max. Voltage switch 1 035 45 5 A 250 V± /C + /O 0.5 These products are part of and distribution systems > See p. 142-143 Control voltage 24 VA 230 VA low noise 230 VA ominal current 16-25 A 25 A 25 A 16-25 A 16-25 A Type of contact Derating of contactors mounted in modular boxes if the internal temperature is > 40 C Contactor rating 40 C 50 C 60 C 70 C Ie = 16 A 16 A 14 A 12 A 10 A Ie = 25 A 25 A 22 A 20 A 18 A Ie = 40 A 40 A 36 A 32 A 29 A Ie = 63 A 63 A 57 A 50 A 45 A Install a spacing unit every two contactors (Cat.o 044 40 or 044 41) 2 Type of conductor Ratings 25 A Ratings 40 and 63 A Ratings 100 A Rigid 1 x 6 2 or 2 x 2.5 2 1 x 25 2 or 2 x 10 2 50 2 Flexible 1 x 6 2 or 2 x 2.5 2 1 x 25 2 or 2 x 10 2 2 x 35 2 Flexible with single ferrule 1 x 6 2 1 x 16 2 - Flexible with double ferrule 2 x 4 2 2 x 16 2 - Cross reference list old range / new range Old range Cat.o ew range Cat.o Designation 040 33 041 14 16 A - 24 V - /C + /O 040 41 041 16 (1) / 041 23 (2) 25 A - 24 V - 2 /O 040 43 041 17 (1) / 041 24 (2) 25 A - 24 V - 4 /O 040 38 041 26 16 A - 230 V - /C + /O 040 49 041 58 (1) / 041 47 (2) 25 A - 230 V - 2 /O 040 52 041 49 25 A - 230 V - 2 /O low noise 040 50 041 29 25 A - 230 V - 2 /C 040 53 041 31 (1) / 041 48 (2) 25 A - 230 V - 4 /O 040 54 041 32 25 A - 230 V - 4 /C 040 55 041 33 25 A - 230 V - 2 /C + 2 /O 040 85 /O + /C 2 /C 041 85 041 83 040 85 4 /O 2 /O /O + /C 2 /O 2 /C Auxiliary changeover switch for 1 module 16 and 25 A contactors Auxiliary changeover switch for 2 modules 25 A contactors Auxiliary changeover switch for 40 A and 63 A contactors 2 /O + 2 /C 4 /O 4 /C umber 1 2 1 1 2 Holding 200 ma 300 ma 6 ma 20 ma 20 ma Inrush 970 ma 300 ma 55 ma 90 ma 200 ma Control voltage 24 VA 230 VA ominal current 40 and 63 A 40 and 63 A 40 and 63 A Type of contact 2 /O 4 /O 2 /O 2 /C 40 and 63 A 3 /O 4 /O 4 /C 100 A 4 /O umber 2 3 2 3 6 Holding 250 ma 270 ma 15 ma 30 ma 60 ma Inrush 1750 ma 1500 ma 150 ma 200 ma 460 ma (1) Without handle (2) With handle Legrand_Protection_Voltage_Surge_Protectors_en_0811.pdf Helsinki tel. +358 9 540 4940 automation@klinkmann.fi St. Petersburg tel. +7 812 327 3752 klinkmann@klinkmann.spb.ru Moscow tel. +7 495 641 1616 moscow@klinkmann.spb.ru www.klinkmann.com Yekaterinburg tel. +7 343 376 5393 yekaterinburg@klinkmann.spb.ru Samara tel. +7 846 273 95 85 samara@klinkmann.spb.ru Кiev tel. +38 044 495 33 40 klinkmann@klinkmann.kiev.ua Riga tel. +371 6738 1617 klinkmann@klinkmann.lv Vilnius tel. +370 5 215 1646 post@klinkmann.lt Tallinn tel. +372 668 4500 klinkmann.est@klinkmann.ee Мinsk tel. +375 17 200 0876 minsk@klinkmann.com