Similar documents
installation manual imagine the possibilities

MODEL 2000T Initial Draft

Air Conditioner. user manual. imagine the possibilities. Data Management Server2. BACnet Gateway. LonWorks Gateway EN DB A(1) MIM-D00AN

HVAC TECHNICAL BULLETIN

NETWORK VARIABLES SPECIFICATIONS. LN INTERFACE Model: TCB-IFLN642TLE

I. Individual control system

Daikin HVAC Controls Guide Specification

Submittal Data Sheet intelligent Touch Manager DCM601A71

VRF. Technical Data Book. Control System

Daikin HVAC Controls Guide Specification

INSTALLATION INSTRUCTIONS LonWorks Interface Model No. CZ-CLNC1U

Installation- & user instructions

FOR ABSORPTION CHILLERS & CHILLER-HEATERS

Packaged Fresh Air Unit With Tracer LCI-I

RCM Room Command Module New Style

Installation- & user instructions

VT7200 Series 24 Vac Low Voltage Zoning Thermostats For Commercial HVAC Applications

Daikin HVAC Controls Guide Specification

MicroTech 2000 Water Source Heat Pump Unit Controller Protocol Information

Software Application wrf08_03 (Lighting, Blinds, Air-Conditioning Control) For model WRF08 T6 T8 T5 T6 T7 T8. Messwert Value

PCM2001N Software Users Guide Version 1 Draft 3 Mar. 2004

INTERFACE SPECIFICATION

BACnet Product Overview

KITS AND ACCESSORIES. Prodigy LonTalk MODULE KIT INSTALLATION INSTRUCTIONS FOR LONTALK MODULE KIT (54W27) USED WITH ENERGENCE ROOFTOP UNITS.

CORRIGO R10. LonMark Functional Profile: Chilled Ceiling Controller Corrigo R10 LonWorks Interface: LonMark Chilled Ceiling Controller

VRF Control System. Judy Ouyang Technical Support Engineer

Functional Profile: Damper Actuators - general purpose - fire and smoke - airflow control

SINGLE. Technical Data Book Zone Control Systems

DVM CHILLER. Installation manual. FCU Application KIT MIM-F00N

SMMS i Selection Tool

Integrated Management System S-NET mini Buttons

VRF. Technical Data Book. DVM S Eco 8, 9 HP

The UP and DOWN buttons will toggle or scroll through the options in each section.

Functional Profile: Chiller

V0STAT51P-2 Programmable Wired Controller

Stryker Lon Configurable Controllers

LRC-XDP. LRC-XDP Datasheet. LRC-XDP Display Panel for Toshiba air-conditioning units. Description

Touch-controller_IM_03943A_1_Co_EN.indd 오후 3:06:00


Air Conditioner. installation manual. imagine the possibilities. DMS2(Data Management Server2) DB A(1) MIM-D00AN

ENERGY-INTELLIGENT TECHNOLOGY HEATING AND COOLING SYSTEMS INTELLIGENT TOUCH MANAGER ONE FOR ALL ADVANCED MULTI-ZONE CONTROLLER

Centralized Remote Controller


Allows detailed and easy monitoring and operation of VRV systems (maximum 2 x 64 groups / indoor units)

Specifications and information contained are subject to change without notice. Always refer to install manuals provided with equipment and controls

TAC Xenta 301. Controller, Freely Programmable

GS828-H. GPRS Data Logger

LONWORKS Compatible DX-9200 Digital Controller

Excel 10 W7751B,D,F VAV II Controllers

IntesisBox Modbus Server - LON

Infilex FC Fan Coil Unit Controller

Itho Lon module for DCW

GS828. GPRS Data Logger

LX Series Remote Input/Output (I/O) Controller

LONMARK Functional Profile: Refrigerated Display Case Controller: Defrost Object

LON Module for Variable Speed Drive

Installation Manual. DZK BACnet

Modbus Interface Module

THERMOSTATS & CONTROLLERS

Programmable Logic Controller

intelligent TOUCH MANAGER ONE FOR ALL ADVANCED MULTI-ZONE CONTROLLER

Third Generation Network Monitoring System

Excel 10 W7752D,E,F,G,J AND W7754K,L,M,P FAN COIL UNIT CONTROLLERS LNS PLUG-INS

LX Series Free Programmable Controllers

Two remote controller system with one Lossnay Basic System (Refer to page C-10) Multiple Lossnay units with one remote controller.

Tracer Controls. Tracer MP.501 Controller BAS-PRC008-EN. June 2001

FCU-4 FAN COIL CONTROLLER

NOTE CONTENTS NOTE-CONTENTS

SE7600E Series Application Guide

HCS-3600 / 3602 / 3604 Laboratory Grade & High RFI Immunity Switching Mode Power Supply with Rotary Encoder Control

LON-module for MULTICAL 601

Richmond Heights. Smart Wi-Fi Capacitive Touch With Dual Protocols Universal Controller. Go Green

VC3000 Series Line Voltage Switching Relay Pack Controllers Installation Guide

Central Controller Operation & Installation Manual

Operation 6035 ENGLISH PROG MENU

DVM E-Solution registration and user manual

M1000 INTELLIGENT ZONE CONTROL SYSTEM

Grundfos CIM 100 and CIU 100

IntesisBox. Making Building Automation go further. LON Products

Building Re-Tuning (BRT) Lesson 4: SOI Air-Handling Unit Part II

MicroTech III Water Source Heat Pump Unit Controller Protocol Information

ExactLogic BACnet Communicating Thermostat EXL01816 Sequence Datasheet

LABORATORY GRADE REMOTE PROGRAMMING SWITCHING MODE DC REGULATED POWER SUPPLIES SDP / 3636 / User Manual

IntesisBox PA-AW-MBS-1 v.2.0

Operation Guide CT100

Excel 10 W7752D,E,F,G AND W7754K,P,Q,R,S,T,V FAN COIL UNIT CONTROLLERS LNS PLUG-INS

REQUIREMENTS FOR WIRELESS, WEB-BASED MONITORING EQUIPMENT AND SERVICES FOR PUMP STATION APPLICAITONS

Lonix Automation/BMS. Installation Manual.

LON module Supplementary Operating Manual

ExactLogic BACnet Communicating Zone Damper EXL01710 Sequence Datasheet

ExactLogic BACnet Communicating Pressure Dependent VAV Damper Control with Heat EXL01820 Sequence Datasheet

Stryker Lon Configurable Controllers

DESCRIPTION WIRING AND INSTALLATION. LonWorks Utility Metering Display NOTE

PRODUCT UPDATE 2011 Smart Manager BMS-SM1280HTLE. Note: Computer NOT supplied

LonWorks Integration Manual ITG-VT72_73-PIR-LON-E07 ( R7 Issue Date: February 3, 2009)

Dip Switch settings.

OPERATION INSTRUCTIONS

WHAT IS THE DIGI-RTU South 59 th Street Omaha, NE bes-tech.net

clarity 3 Programmable Controller

DESCRIPTION OF MODBUS CONNECTION

Transcription:

Page 1 of 7 Job Name Location Purchaser Engineer Submitted to Reference Approval Construction Unit Designation Schedule # Features LonWorks Gateway Control gateway that allows control and monitoring of Samsung DVM S systems via LON TP/FT-10A (free topology 78kbs) Easy Control & Monitoring Through Web Browser Individual/Group control of up to 128 indoor units (maximum quantity of indoor units will vary based on the number of objects being monitored/controlled) Operation mode, temperature setting, airflow direction, fan speed, temperature restriction settings, unoccupied mode setting, and discharge air temperature setting (for applicable duct unit models). Restrict use of wireless/wired remote controllers, mode, temperature, and set point. Outdoor and indoor unit cycle monitoring Convenient digital display allows for easy initial set up SD memory card slot for data storage and software updating (daily automatic backup, SD card purchased separately) LAN connection for upper level control options Available sophisticated control logic allows programming outputs based on various system inputs Dynamic security management Operation and error history management Maximum current control of outdoor unit(s) to limit current (50% - 100% of design current) adjustable at outdoor unit or (does not apply to all system models) Supports multiple user access (different usernames and access levels) Various user management level settings (HVAC system access, gateway permission access) Unoccupied room control settings adjustment capability (for compatible units) Web Server Function Remote control with a public IP address via internet connection No management software required PC-independent management through web browser (optimized for Internet Explorer) Multiple user accounts can be setup with the ability to specify what unit(s) each individual can monitor and control and what level of control permission is allowed. Schedule Control Function Through Web Browser Up to 256 schedule settings Weekly and daily schedule setting Wireless/wired remote controller restriction setting Digital outputs can be incorporated into scheduling Advanced Programmable Control Logic Setting Specify various system control point inputs (indoor units, outdoor units, DI, DO) and operators (=, >, <,,, ) to manipulate system operation (indoor units, outdoor units, DI, DO) based on the status of the specified variables. Advanced Heat Pump Auto Changeover Logic Optional "weighted averaging" or "representative" setting for heat pump systems to provide optimal auto changeover while in Auto mode. External Contact Interface Full indoor unit control with simple contact input (emergency/lock) 8 additional digital input terminals for monitoring options State output (operation/error) for synchronous control 6 general purpose outputs to control other components (on: 12VDC out; off: no voltage) Digital inputs and digital outputs can be incorporated into control logic Digital outputs can be incorporated into control logic and daily schedules to control other devices Energy Management / Power Distribution Function Ability to monitor, track, and query energy use from indoor unit(s) and systems with MIM-B16 or MIM-B16N and electricity meter interface module (purchased separately, requires 3rd party watt-hour meters with pulse output). When used with SNET 3 software, detailed PDF report generation is possible User defined daily time periods for energy use reports to accommodate on/off peak energy billing. Export energy usage and other data to Excel file History Management Storage of all operation commands from gateway and other system controls (saves to SD card purchased separately). Storage of all error events for review (saves to SD card purchased separately). Storage of all operation logic control events (saves to SD card purchased separately). Error alerts via email that contain: error code, error explanation, units affected, time and date of error occurrence, and error status. QS-DVMS-072016A 888-699-6067

Page 2 of 7 Specifications network ID can be assigned 1-16 (this number will determine device ID of gateway and all equipment) shall support TP/FT-10A (free topology 78kbs) and provide functions to monitor status and control Samsung DVM S, CAC, FJM, ERV (MIM- N10 interface module adapter required), and DVM Chiller systems shall monitor status and control Samsung systems only via web client, BMS, and/or Samsung SNET 3 software. Connection of FJM and DVM Plus III equipment or earlier models will require a communication interface module adapter (MIM-N01) DC 12V, 3A power provided by AC/DC adapter (input 110-240VAC 50/60Hz, provided with ) Communication connection via ON/OFF Controller(s) (MCM-A202DN) and direct connection to DVM S series (AM*********/AA, AG*********/AA and CAC (AC0********/AA) outdoor units 16 AWG X 2 shielded cable between Samsung equipment and controls is necessary for proper operation Use communication cable recommended by BMS manufacturer between and LonWorks BMS devices XIF files available Maximum number of RS485 connections: - Maximum 75 ON/OFF Controllers (MCM-A202DN) to 1 - Maximum 15 ON/OFF Controllers (MCM-A202DN) to a single channel - Maximum 75 Touch Central Controllers (MCM-A300N) to 1 - Maximum 15 Touch Central Controllers (MCM-A300N) to a single channel - Maximum 16 systems to a single channel (5 total) - Maximum 80 systems connected direct (5 ports, 16 systems per port), 128 through ON/OFF Controllers (MCM-A202DN) - Maximum 16 Chiller FCU Interface Modules (MIM-F10N) to a single channel (5 total, each MIM-F10N supports up to 16 MIM-F00N FCU Kits) - Maximum 80 Chiller FCU Interface Modules (MIM-F10N) connected direct (5 ports, 16 X MIM-F10N per port) - Maximum 128 indoor units on a single channel (HR MCU, air handlers, and Samsung ERV's) - Maximum 128 indoor units (HR MCU, air handlers, and Samsung ERV's) to one - Maximum 8 MIM-B16 Energy Meter Interface Modules per (must connect to CH4 (COM5) on gateway) - Maximum 8 MIM-B16N Energy Meter Interface Modules per (can connect to same channel as DVM S outdoor units on gateway) Digital inputs and outputs: - DI terminals (X 10): Dry input (0V) - DO terminals (X 8): 12VDC, maximum 200 ma Standard program identifier - Manufacturers: Samsung Electronics Co., Ltd. MID: 191 - Device classes: 70.00 - gateways, 72.80 --- HVAC gateways - Usage (device subclass): Utility {11} - Channel types: TP/FT-10 {ID : 4} - Object types: 8500 - Description: SCC - Generic - SFPT name: SFPTspaceComfortController - Program ID: 90:00:BF:48:50:0B:04:00 Refer to controls Technical Data Book for more information found at www.dvmdownload.com. 9 3/8" 2 1/2" 10"

Page 3 of 7 Installation with Direct Connection to s (BOTTOM) F1 F2 R1 R2 Maximum 16 per channel 0 0 1 1 Maximum 16 per channel F F Installation with Centralized Controller and Direct Outdoor Connection MCM-A202DN (ON/OFF Controller) MCM-A202DN (ON/OFF Controller) Maximum 16 per channel DMS-2.5 Maximum 16 Centralized Controllers per Maximum15 Systems per ON/OFF Controller F1 F2 R1 R2 Maximum15 Systems per ON/OFF Controller MCM-A202DN (ON/OFF Controller) Installation with MIM-B16 / MIM-B16N - Energy Management Pulse Input Module LAN Web Browser or SNET 3 F1/F2 BMS Watthour Web Browser or SNET 3 F1/F2 Electrical Panel Watt-hour Meter F1/F2 The diagrams on this page are for reference only. Refer to installation manual for wiring and installation instructions. Other configurations may be possible.

Item Summary Page 4 of 7 Item summary* Control & Monitoring Item Common Indoor unit AHU Additional functions Function Operation On/Off Operation mode Air flow direction Fan speed Device error information Model, address, type information Set temperature Indoor temperature Filter replacement alert/ reset Remote controller level Thermostat information Operation restriction setting (Cooling/Heating) Setting lowest temperature/ restriction Setting highest temperature/ restriction Power consumption Operation time Emergency stop DMS2.5 DI/DO DMS2.5 lock DMS2.5 error information System error information *Not all objects listed are available for all equipment models. See technical data book or installation manuals for full details regarding equipment control/monitoring objects. Maximum quantity of indoor units will vary based on the number of objects being monitored/controlled Control and Monitoring Item Maximum Number of Connectable Indoor Units 27 Items (all) 22 20 Items 30 15 Items 40 12 Items 50 9 Items 64 6 Items 100 4 Items 128 20 items can be processed per second, data inquiry interval is 30 seconds.

Network Variable Page 5 of 7 Network variable Indoor unit / ERV / AHU kit object No. Name Type M/O Description 1 nvionoff SNVT_switch O ON/OFF command 2 NviApplicMode SNVT_hvac_mode O Setting operating mode 3 nvisetpoint SNVT_temp_p O Setting desire temperature 4 nvifanstatus SNVT_switch O Setting fan speed 5 nviervmode SNVT_count O Setting ERV operation mode 6 nvifilterreset SNVT_switch O Filter reset command 7 nviuserlockout SNVT_switch O Setting the restriction of remote control use 8 nvioccopmode SNVT_switch O Setting cooling only mode / heating only mode 9 nvicooltemplock SNVT_switch O Setting the low temperature limit 10 nviheattemplock SNVT_switch O Setting the high temperature limit 11 nvospacetemp SNVT_temp_p M Display indoor temperature 12 nvoapplicmode SNVT_hvac_mode O Display operating mode 13 nvosetpoint SNVT_temp_p O Display desire temperature 14 nvoonoff SNVT_switch O Display ON/OFF status 15 nvofanstatus SNVT_switch O Display fan speed 16 nvoervmode SNVT_count O Display ERV operating mode 17 nvoerrorcode SNVT_count O Display Error code 18 nvodevicealarm SNVT_state O Remote control lock, Filter sign, Thermo ON/OFF, Error occurrence status display 19 nvooccopmode SNVT_switch O Cooling only/heating only setup status display 20 nvocooltemplock SNVT_switch O Display low temperature limit setting status 21 nvoheattemplock SNVT_switch O Display high temperature limit setting status 22 nvouserlockout SNVT_switch O Display the restriction of remote control use 23 nvoenergyconp SNVT_elec_kwh_l O Display electricity usage (Time Period) 24 nvoenergycon SNVT_elec_kwh_l O Display electricity usage (Basic date) 25 nvoruntimep SNVT_time_hour O Display used hours (Period) 26 nvoruntime SNVT_time_hour O Display used hours (Basic date) 27 nvodevlistdesc SNVT_str_asc O Indoor unit HW information DVM system object No. Name Type M/O Description 1 nvidigitalout[6] SNVT_ switch O Control Digital output of DMS 2 nvialloff SNVT_hvac_emerg O Control all indoor unit / ERV OFF 3 nvodigitalout[6] SNVT_ switch O Display Digital output status of DMS 4 nvodigitalin[8] SNVT_ switch O Display Digital input status of DMS 5 nvosystemlock SNVT_ switch O Display System Lock status of DMS 6 nvodms2alarm SNVT_ count O Display communication error of the sub device connected to DMS 7 nvosystemalarm SNVT_ count O Display error satus Configuration properties No. Name Type M/O Description 1 ncisndhrtbt SNVT_time_sec SCPTmaxSendTime O Send Heartbeat 2 nciminouttm SNVT_time_sec SCPTminSendTime O Minimum Send Time 3 ncimindeltatemp SNVT_temp_p SCPTminDeltaTemp O Min. difference before update 4 ncidelaystatrup SNVT_time_sec SCPTpwrupDelay O Delay time after a power-up Refer to controls Technical Data Book for more information found at www.dvmdownload.com.

Network Variable List Page 6 of 7 Network variable list* No. NV Name Description Indoor ERV AHU Kit / Multi-position AHU 1 nvionoff ON/OFF command O O O 2 nviapplicmode Setting operating mode O X O 3 nvisetpoint Setting desirable temperature O X O 4 nvifanstatus Setting fan swing and speed O O X 5 nviervmode Setting ERV operation mode X O X 6 nvifilterreset Filter reset command O O O 7 nviuserlockout Setting the restriction of remote control use O O O 8 nvioccopmode Setting cooling only mode / Setting heating only mode O X O 9 nvicooltemplock Setting the low temperature limit O X O 10 nviheattemplock Setting the high temperature limit O X O 11 nvospacetemp Display indoor temperature O X O 12 nvoapplicmode Display operating mode O X O 13 nvosetpoint Display desire temperature O X O 14 nvoonoff Display ON/OFF status O O O 15 nvofanstatus Display wind speed and direction O O X 16 nvoervmode Display ERV operating mode X O X 17 nvoerrorcode Display Error code O O O 18 nvodevicealarm Remote control Lock, Filter Sign, Thermo ON/OFF, Error occurrence status display O O O 19 nvooccopmode Cooling only/heating only setup status display O X O 20 nvocooltemplock Low temperature limit setting status display O X O 21 nvoheattemplock High temperature limit setting status display O X O 22 nvouserlockout Display the restriction of remote control use O O O 23 nvoenergyconp Display electricity usage O X X 24 nvoenergycon Monitor total electricity usage O X X 25 nvoruntimep Display used hours (Period) O X O 26 nvoruntime Monitor total operation hours O X O 27 nvodevlistdesc The summary of device information (Model, Address, Operation Status) O O O *Supported NV (Network Variable) is different depending on connected devices Refer to controls Technical Data Book for more information found at www.dvmdownload.com.

Network Parameter Chart Page 7 of 7 Indoor unit/ ERV/ AHU kit object SSACIndoor[nn](objectid=1-128) nvionof f SNVT_switch nviapplicmode SNVT_hvac_mode nvisetpoint SNVT_temp_p nvifanstatus SNVT_switch nvier VMode SNVT_count nvifilterreset SNVT_switch nviuserlockout SNVT_switch nvioccopmode SNVT_switch nvicoolt emplock SNVT_switch nviheattemplock SNVT_switch nvospacetemp SNVT_temp_p nvoapplicmode SNVT_hvac_mode nvosetpoint SNVT_temp_p nvoonoff SNVT_switch nvofanstatus SNVT_switch nvoervmode SNVT_count nvoerrorcode SNVT_count nvodevicealarm SNVT_state nvooccopmode SNVT_switch nvocooltemplock SNVT_switch nvoheattemplock SNVT_switch nvouserlockout SNVT_switch nvoenergyconp SNVT_elec_kwh_I nvoenergycon SNVT_elec_kwh_I nvoruntimep SNVT_time_hour nvoruntime SNVT_time_hour nvodevlistdesc SNVT_str_asc DMS system object SSACSystem(objectid=129) nvodigitalout[6] SNVT_switch nvidigitalout[6]_switch nvialloff SNVT_hvac_emerg nvodigitalin[8] SNVT_switch nvosystemlock SNVT_switch nvodms2alarm SNVT_count nvosystemalarm SNVT_count Configuration Properties ncisndhrtbt nciminouttm ncimindelta Temp ncidelaystartup