GA-12. madur Polska sp. z o.o.

Similar documents
HAND-HELD GAS ANALYSER

Differential pressure measuring instrument

Differential pressure measuring instrument

Differential pressure measuring instrument

Environmental Equipment, Inc.

Differential pressure measuring instrument

Differential pressure

Flue Gas Analyzer. The Value Leader TM

Differential pressure measuring instrument

The flue gas analyzer with Longlife sensors and integrated draught/gas zeroing

testo 350 Flue gas analyzer Short manual

VAC analysis measuring instrument

testo LL Flue gas analysis with increased convenience and reliabilty

Instruction Manual /1/03. EGA2 Combustion Analyzer

Hand-held flue gas analyser Instruction Manual MM ed. K12

4-gas detector. Versatile multi-gas H 2 S O 2 SO 2 LEL

News from EIUK. The New RASI 300 Flue Gas Analysers. Plug & Play sensors User Replaceable plug and play sensor

testo 350 Combustion & Emission Analyzer Short manual

CONTENTS Introduction 4 DTR overview 4 probes 5 functions 5 display 5 DTR operation 6 switching the DTR on or off 6 changing label 6 displaying

Handheld flue gas analyzers Instruction Manual MM ed.1a

testo 735 Compact Pro Series NEW! The working standard for temperature measurements

Infrared temperature measuring instrument

Portable flue gas analysers Instruction Manual MM ed. K12

PIECAL 322 Automated Thermocouple Calibrator Operating Instructions. Product Description. Practical Instrument Electronics

Vaisala HUMICAP Structural Humidity Measurement Kit SHM40. Full SHM40 product presentation and introduction to the borehole method

PV Remote Unit A 1378 Instruction manual Version 2.1, Code no

Hand-Held Pressure Indicator

PTR. printing temperature recorder. User Manual. order code:

APPLICATIONS. Boiler / Burners Turbines Engines Incinerators Process Control Landfills Cogeneration plants

ARA FTS Flow Calibrator. Operation Manual August 1, 2016

SPECIFICATIONS HAND HELD PARTICLE COUNTER KC Higashimotomachi, Kokubunji, Tokyo , Japan

712 Rev. 2.x Analyzers

712 Rev. 2.x Analyzers

STATIONARY GAS ANALYSER

Gas detection just got personal

Flue Gas Analyser TPI 716. The Value Leader TM

x testo 400 The reference measuring instrument for A/C and ventilation systems Additional information at

Portable low-pressure controller Model CPC2000

ProcessCalibrator Model CPH6000

PCD DIGITAL Differential pressure probe

Next Generation! We measure it. With the professional Testo data loggers, a new age begins for you. Logger series testo 174. Logger series testo 175

Precision hand-held pressure indicator Model CPH6400

Handheld Water Quality Meters 100 Series

Light intensity measuring instrument

CO Analyzer. The Value Leader TM

Hand-Held Pressure Indicator Model CPH6200-S1 Model CPH6200-S2 (2-channel version)

Hand-held thermometer Model CTH7000

Next Generation! Committing to the future. With the professional Testo data loggers, a new age begins for you. Logger series testo 174

Precision Hand-held Thermometer

Technical Information Liquiline To Go CYM290 and Liquiline To Go Ex CYM291

Next Generation! We measure it. With the professional Testo data loggers, a new age begins for you. Logger series testo 174. Logger series testo 175

Phone: Fax: For calls outside the US please call:

DX4085 Z-Meter Tester

Miles Ahead of the Competition!

4 AA nickel-etal bybrid cells (min. 2,200 mah) Use only AC Adapter (5 VDC / min. 1 A) supplied for recharging

Instruction Manual. Flue Gas Analysis Computer Type: MULTILYZER STx. Read manual before use! Observe all safety information!

Portable Combustion Analyzer

USER MANUAL Video Particle Counter with built in Camera Model VPC300

ProcessCalibrator Model CPH6000

JSP Industrial Controls

Pressure Switch CE40. Digital settings available via IR data communication without actually applying pressure to the unit

PIECAL 520B & 521B Thermocouple Source Operating Instructions

CALOG CALOG - LC DISPLAY. Loadcell Display. English Users Manual. Rev. 1.10

Hand-held pressure indicator Model CPH6300-S1 (1-channel version) Model CPH6300-S2 (2-channel version)

Electrochemistry Meters. Series SD (IP 67 waterproof) Electrochemistry Meters

Dual channel temperature logger with two voltage inputs 0-5V Instruction Manual

SENSIT IRED INSTRUCTION MANUAL INFRARED ETHANE DETECTOR READ AND UNDERSTAND INSTRUCTIONS BEFORE USE. 851 Transport Drive Valparaiso, IN

Table of Contents. Important Tips Instrument Design ECOM-B Accessories Analyzer Start-Up Opening/Creating Data Records 8

Dual channel temperature logger with display Instruction Manual

SENSIT P400. Accessories. Replacement Parts. Calibration Kits. Calibration Gases MADE IN THE USA WITH GLOBALLY SOURCED COMPONENTS

EL-WiFi-TH WiFi Temperature & Humidity Data Logging Sensor

Combustion Gas Analyzer. Instruction Manual Configuration Operation Maintenance. P/N: Revision 0 August 29, 2012

TPI 712BT. Flue Gas Analyser

SENSIT HCN. Accessories. Replacement Parts. Calibration Kits. Calibration Gases MADE IN THE USA WITH GLOBALLY SOURCED COMPONENTS

TR-7 Series. Network / USB Data Loggers TR-7wf/nw Series Infrared / USB Data Loggers. TR-7Ui Series

G460 Multi-gas Detector

Eltek TU GenII AQ110A comprehensive portable air quality monitor transmitter

PROTIMETER. TimberMaster. Protimeter Moisture Meter (BLD5605, BLD5609, BLD5605-SW, BLD5609-SW) Instruction Manual. Amphenol.

DPL4000 Portable Low Range Dew Point Analyzer

HI 9828 Multiparameter Water Quality Meter...

THE TECHNOLOGY BEHIND THE MEASUREMENT

JUMO PINOS L01. Calorimetric flow sensor. Brief description. Special features. Customer benefits. Data Sheet

Table of Contents & Introduction 2 Product features & composition. 3 Functions Specifications

Pressure sensors SDE1, with display

Hand-Held Thermometer Model CTH 6200

HI 9828 Multiparameter Water Quality Meter...

GA-12 plus service programme. Manual. v.2.12 E L E C T R O N I C S

SIDEPAK AM510 Personal Monitor

AEROTRAK PORTABLE AIRBORNE PARTICLE COUNTER MODEL 9310/9350/9510/9550/9500 QUICK START GUIDE

Multifunction instrument AMI 310

Portable Combustion Analyzer (PCA)

CN51 CN50. Accessory Guide. Docks and Modules. Accessory Name Part Number Description

DEFECTOMETER High detection sensitivity to surface flaws (even underneath paint) Simple, microprocessor-controlled operation

DM650TM SENSOR / WALL MOUNTED TEMPERATURE DISPLAY

Model 475 Field Communicator. Connection. Environmental. Shipping Weight

SENSIT HCN Hydrogen Cyanide Analyzer

Pressure transmitter for highest pressure applications Up to 217,500 psi (15,000 bar) Model HP-2

14 Pressure Measurement. Measuring Devices Description Pressure range Connection Device Page

Hand-held thermometer, precision version Model CTH6500 Model CTH65I0, Ex version

DPA+ LCD. Application. Types Available. Differential Pressure Transmitter. Datasheet

Transcription:

www.madur.com is madur s smallest gas analyser - hand-held, equipped with up to 3 EC cells. Small dimensions and light weight makes it very convenient for technicians that use analyser on a daily basis. Rich offer of equipment and add-ons makes it interesting for more demanding users. Manufactured according to the principles of EN50379. 1

Equipped with 2 or 3 electrochemical cells (typical configuration: O2, CO, NO/NOx) Works with an external portable printer via wireless communication (IR LED) Up to 60 hours of work (version with replaceable alkaline batteries) Fixed probe of two different lengths with inline filter and condensate trap Differential pressure sensor - for measurements of chimney draft and flow velocity (with help of Pitot tube) Additional gas filter with condensate trap (installed in the lid) Differential pressure sensor - for measurements of chimney draft and flow velocity (with help of Pitot tube) Cooperation with digital RH and temperature sensors Measurements of gas and ambient temperatures Results presented on LCD display (128*64) with backlight Calculations of many additional parameters Firmware for gas calibration Two versions of power supply are possible: version with four replaceable AA batteries (alkaline, Ni-Cd or Ni-MH) version with built-in Li-ion rechargeable battery and aditional mains adapter for battery charging SUPPLY / CHARGER (DELIVERED ONLY WITH B VERSION - WITH Li-ION BATTERY) RH PROBE IN- LINE FILTER GAS PROBE L=150MM SOFTWARE & DOCUMENTS CD RS232C CABLE 2

ANALYSER VERSION A VERSION B WITH REPLACEABLE AA BATTERIES WITH BUILT-IN Li-ION BATTERY 245 mm * 116 mm * 47 mm Dimensions (W * H * D) Weight (without accessories & batteries) 470 g 510 g Housing material ABS case, rubber protective boot (optional) Operating conditions T: 10 C 50 C, RH: 5% 90% (non-condensing) Storing temperature -20 C 55 C Power supply 4 * AA battery (alkaline or Ni-Cd or Ni-MH) Built-in Li-ion battery (3,6 V, 1600 mah) Operating time Up to 60 hours Up to 16 hours Number of gas sensors 2-3 Memory for results for 64 measurements reports Display Graphical LCD 128 * 64, with variable contrast and LED backlighting Gas pump Diaphragm, max 0,6 0,9l/min Printer External thermal IR printer MCP 8850 with charger RS-232C Communication interface with PC computer 150mm 2m 300 C max Gas probe: length hose length temp. range Gas filtering In-line filter included in the gas probe hose MEASUREMENTS Variable Method Range Resolution Accuracy Time (T90) T gas- gas temperature K-type thermocouple -10 1000 C 0,1 C ± 2 C T amb boiler intake air temperature PT500 resistive sensor -10 100 C 0,1 C ± 2 C Differential pressure Silicon piezoresistive pressure sensor -25 hpa +25 hpa 1 Pa (0,01hPa) ± 2Pa abs. or 5% rel. Gas flow velocity (optional) Indirect, with Pitot tube & pressure sensor 1 50 m/s 0,1 m/s 0,3 m/s abs. or 5% rel. RH - relative humidity SHT11 capacitive polymer 5 95% 1% sensor (special probe needed) ± 5% rel. 30 sec Lambda λ - excess air number Calculated 1 10 0,01 ± 5% rel. qa - stack loss Calculated 0 100% 0,1% ± 5% rel. Eta - η combustion efficiency Calculated 0 120% 0,1% ± 5% rel. 3

Method Range Resolution Accuracy Time (T90) Conformity O2 - A2 electrochemical sensor 20,95% 0,01% ± 0,01% abs. or 5% rel. O2 - A2 electrochemical sensor 25,00% 0,01% ± 0,01% abs. or 5% rel. CO - AF electrochemical sensor 2 000 ppm 0,1 ppm CO - AF electrochemical sensor 4 000 ppm 1 ppm CO - AF electrochemical sensor 20 000 ppm 1 ppm ± 10 ppm abs. or 5% rel. CO - AE electrochemical sensor 10% 0,001% ± 0,005% abs. or 5% rel. CO - AX electrochemical sensor with low H2 cross sensitivity 4 000 ppm 1 ppm NO - AE electrochemical sensor 2 000 ppm 0,1 ppm NO2 - AE electrochemical sensor 1 000 ppm 0,1 ppm SO2 - AE Electrochemical sensor 2 000 ppm 0,1 ppm EN 50379 2 000 ppm 0,1 ppm O2 - OXYGEN CO - CARBON MONOXIDE NO - NITRIC OXIDE H2S- HYDROGEN SULPHIDE H2S - AE electrochemical sensor 4

STANDARD EQUIPMENT SUPPLIED ALONG WITH THE DEVICE Carrying case made of HDPE for analyser and accessories 4 * AA alkaline batteries OR built-in Li-ion battery + mains adapter 2,5m RS-232C communication cable with DB9 female connector Software CD with programmes and manuals ADDITIONAL EQUIPMENT NECESSARY FOR THE ANALYSER TO WORK Gas probe 150mm or 250mm Complete gas probe (L=150mm or L=250mm, OD=8mm). Made of stainless steel, equipped with K-type thermocouple. Delivered with fastening cone, in-line filter and 2,0m gas-electric line with 4-pin male plug. gas probe L = 150mm - E-SON1200 OPTIONAL EQUIPMENT & SPARE PARTS Portable printer and printer paper Portable printer (battery operated), communicates with the analyser via wireless HP-IR interface. Allows to print measurements results instantly on the 58mm thermal paper. The printer is delivered together with 4 Ni-MH rechargeable batteries, mains adapter (for batteries charging) and single roll of paper. printer - M20-2DHP2 thermal paper roll - V-THP5701 Magnetic holder Modified battery cover with magnets installed in it. This magnetic holder allows to attach the analyser to the metal parts of the boiler, what makes the operation with the analyser even simpler. Replaces the standard battery cover. Delivered with fixing screw. Z12-MAGN-HOLD Leatherette casing Soft casing (just for the analyser) made from leatherette, protects the analyser during transport. M12-ETUI1 5

OPTIONAL EQUIPMENT & SPARE PARTS Rubber protector Special rubber protector for the analyser s casing. Protects the analyser against hits and blows. Z12-RUBBER-001 Ambient temperature sensor This ambient PT500 temperature sensor on a 3m cable is used for measurement of the boiler s inlet air. Z12-SENS-TEMP Anchor cone for PT-500 ambient temperature sensor This cone allows fitting the temperature sensor into holes with different diameter. Z14-CONE-PT500 Magnetic holder for PT500 sensor This magnetic holder allows to safely hang the sensor on a metal surface. Z14-MAGN-PT500 RH and ambient temperature probe Probe for RH and ambient temperature measurements. Not-suitable for inside stack measurements (working temperature up to 120 C). Z14-SON-HUM Pitot tube Pitot tube is used for indirect measurement of gas flow velocity (measurement with the analayser s differential pressure sensor). A few lengths of tubes are available. Pitot tube has 2m gas tubings to connect it with the analyser. pitot tube 800mm - Z00-PITOT-8002 pitot tube 500mm - Z00-PITOT-5002 RS232C to USB converter 2,5m cable that allows to connect the analyser (its RS232C port) with USB port in PC computer (especially valuable when PC is not equipped with COM port). Z12-USB-ADAP Bluetooth communication module Module connected to the analyser s RS232C port, allows to communicate with PC computer over Bluetooth protocol. Z12-BLUE-TOOTH 6

AA alcaline batteries or Ni-MH AA rechargeable batteries Alcaline batteries, 1,5V, size AA/ Rechargeable batteries Ni-MH, 1,2V, size AA, 2000mAh (or better) Remember the rechargeable batteries need external charger (cannot be charged inside the analyser). alkaline batteries- 590E0150A.M rechargeable batteries - 590D1216A.M Li-ion rechargeable battery Rechargeable batteries Li-ion, 3,6V, 1600mAh (or better). Spare part for the B version analysers. Z14-BAT-CHARGER_02 Pressure test kit Pressure test kit allows to perform leakage test of the pneumatic / gas installations. Requires analyser s differential pressure sensor to operate. Z12-LEAK-TEST-KIT In-line filter In-line filter for all the types of probes. Spare part for gas probes. Z14-FILTER-INLINE In-line filter insert 20µm In-line filter insert for all the types of probes. V-FELM252 4-pin male plug 719 series or equivalent 4-pin plug for all the types of probes. 513N7194C 4-pin male plug 719 to 7-pin female socket adapter plus 4-pin plug to 7-pin female socket adapter. Enables use of all the types of GA-21 probes with analyser. Z12-PROBE-ADAPTER Mains adapter for Li-ion battery charging For use only with the B-version of (with built-in Li-ion battery). The mains plug has to be ordered separately. adapter without mains plug - 196B2001A EU (European) plug - 196B2011A US plug - 196B2021A UK plug - 196B2031A AUS (Australian) plug - 196B2051A 7

FRONT PANEL VS plus SIZE COMPARISON 128*64 MONOCHROMATIC DISPLAY WITH BACK-LIGHT ON BUTTON / FUNCTION KEY 7 NAVIGATION AND FUNCTION KEYS INSTANT PRINTOUT KEY OFF BUTTON BOTTOM VIEW GAS INLET TOP VIEW A VERSION WITH AA REPLACEABLE BATTERIES GAS OUTLET RS232C IR LED - COMMUNICATION WITH PORTABLE PRINTER B VERSION WITH BUILT-IN FIXED LI-ION BATTERY EXTERNAL TEMPERATURE SENSOR / RH PROBE THERMOCOUPLE / AMBIENT TEMPERATURE MEASUREMENT DIFFERENTIAL PRESSURE MEASUREMENT INLETS POWER SUPPLY / BATTERY CHARGING SOCKET 8

EXAMPLE PRINTSCREENS EXAMPLE SCREENSHOTS FROM THE PROGRAMME 9