D1265. Installation Guide. Touchscreen Keypad

Similar documents
D1260/D1260B. Installation Guide. Keypads

ICP-SDI Installation Instructions. SDI Splitter

Control Panel D9124. Release Notes for Version 7.00 March Introduction. 2.0 Requirements. 4.0 Previous Version 6.

Control Panel D9112. Release Notes for Version 7.00 March Introduction. 2.0 Requirements. 4.0 Previous Version 6.

D1260/D1260B. Owner's Manual. Keypad

Installation Instructions

7760 LCD Glass Keypad

Control Panels D9412GV4/D7412GV4. en Owner's Manual

CP150B Vandal & Weather Resistant Keypad Security Systems

Control Panels B9512G/B8512G/B6512/B5512/B4512/B3512. en Owner's Manual

ATP1000 Touchpad/Display Installation Instructions

Control Panel. D9412GV4/D7412GV4/D7212GV4 v1.xx. Release Notes

REMOTE KEYPAD with NFC Tag (KPT-32N, KPT-32N-F1)

791/793 Easy Entry Keypads

INSTALLATION SHEET 791 and 793 Easy Entry Keypads

CA111x-series Arming Station

FPA-1000-V2 Network Cards FPE-1000-NE, FPE-1000-NF, and FPE-1000-NW

Installation Instructions. Product Summary. Installation Guidelines. Tools and Equipment Needed. Table 1. Touchpad Power Usage

EA500. Installation Instructions Transponder

Installation and Operation Back-UPS BR1000G-IN / BR1500G-IN

User Manual. PCKeypad Wireless Keypad

7000 Series Thinline LCD Keypads Models 7060/7063/7070/7073

Product Information. DCM Standard indoor stations TK IS A 514 A.. TK IS A 514 AD.. (Design)

Enclosures AE1/AE3. Installation Guide

SL2000E. Status Output. Electronic Code Lock. Features. Input. Exit Button Input. Introduction. Door Contact Input. Functional Description.

User Manual Back-UPS BE650MC

Conettix Plug-in Communicator Interface

Conettix D6680. Installation Instructions. Ethernet Network Adapter

NX1700EIB02 (Supercedes NX1700EIA02) NetworX Series. NX-1700E Proximity Card Reader Installation and Startup

INSTALLATION INSTRUCTIONS

Control Panels. D9412GV4/D7412GV4 v en Release Notes

Remote Programming Software LITE (RPS LITE)

MODEL KP-100 ACCESS CONTROL DIGITAL KEYPAD OPERATING INSTRUCTIONS

Control Panels B5512/B4512. en UL Installation Instructions

smartentry Wireless Video Doorphone User Manual

Modules Programming Guide. paradox.com

SigNET 200/300 User Guide

Intrusion Control Panels Quick Guide. May 2015

USER S GUIDE. USA Mobility. Odyssey. Numeric Pager

Digital Keypad Introduction

Security System. Owner s Manual

Users Manual. Operating and Installation Instructions Buffalo River Black Dimaond. Model:ECSL-0601A Electronic Combination Controller

Contents. 4. Disarming the Control Panel How to Disarm with a User Code How to Disarm using a Key-Switch or Remote...

ATLAS 8 PLUSTM USER GUIDE LED & LCD. Rins 160 Issue 2

Installation Guide. Thinline LCD Keypads 7560, 7563, 7570, 7573 Aqualite LCD Keypads Models 7560A, 7563A, 7570A, 7573A

Keypad LCD (software version 3.10) CA-10 plus

Installation Instructions Installation Guidelines. Product Summary. For the maximum number of bus devices and touchpads per panel see Table 1.

2 IDS LCD Keypad User Manual C Issued March 2009

4XLFN6WDUW*XLGH. LYNXR is not intended for UL985 Household Fire applications.

1-Line Alpha/Numeric Pager

D2112 Keypad Diagnostics

Home Automation, Inc. Model 32A00-5. OmniTouch with Video Touchscreen

Wireless headset user guide

EN TECHNICAL MANUAL. ViP Mini hands-free monitor art. 6721W. Passion.Technology.Design.

CM-110SK Standalone Keypad Installation Instructions

MTGW. Installation Guide. CAN-RS-485 BUS Gateway


Intelligent Security & Fire Ltd

INSTALLATION INSTRUCTIONS

Taurus Super-S3 LCM. Dual-Bay RAID Storage Enclosure for two 3.5-inch Serial ATA Hard Drives. User Manual March 31, 2014 v1.2

ACTsmart2 Product Range Operating and Installation Instructions

IDS X-Series User Manual E Issued June 2013

For use with QED controls panels ONLY

Instruction Manual. Vogue. Security. Technology. Innovation 2013-V01

IDS. Users Guide to Keypad Functions S E C U R I T Y MANUAL NO D ISSUED NOVEMBER 2002 VERSION 2.

Documentation on all Paxton products can be found on our web site -

EN TECHNICAL MANUAL. Icona door entry monitor Art. 6601W - Art. 6601W/BM. Passion.Technology.Design.

RFID/Digital Access Control Keypad

PROGRAMMING AND INSTALLATION MANUAL

SuperBus Hardwire Input Module (HIM) Document Number: Rev. C September 1998

FPD-7024 Fire Alarm Control Panel Version 1.03

Keypad LCD-L (software version 3.10) CA-10 plus

Control Panel Solution 2000 / 3000

CV-550SPK V2 Waterproof Keypad/Reader/Controller Installation Instructions

Applicable to the EURO 46, 76, 162 and 280 control panels, software V9 or above.

AUDIO AND VIDEO DOOR ENTRY SYSTEM WITH NEXA CODED PANEL

Emergency Dialer DIAL-ALERT MODEL: AD

GSM AD05 Slave GSM Auto Dialer- Instruction Manual

EN TECHNICAL MANUAL. Mini door entry monitor with handset Art / Passion.Technology.Design.

Remote Programming Software LITE (RPS-LITE) D5500CU-LITE, v6.05

Conettix ITS-D6682-UL

Conettix Plug-in Communicator Interface

Installation and Operation Back-UPS Pro 900

SERVICE MANUAL MODEL SSW-521-D2-ADA

Operating Manual Quattrino RE529, two tone

Concord LCD Keypad with 2-Way Voice Installation Sheet

ATLAS 8 PLUSTM USER GUIDE LED & LCD. Intelligent Security & Fire Ltd Rins 160 Issue 6

TouchOne Mini User s Guide

SPCK420/421 LCD-Keypad for SPC4000/5000/6000. User Manual. Building Technologies. Fire Safety & Security Products

Installation Guide DRAFTMF4100

EVOKO MINTO CONFERENCE PHONE

SK-1011-SDQ Access Control Keypad. Manual

Wireless keypad PRF-LCD-WRL

Control Panel ICP-SOL2-P/ICP-SOL3-P. en Quick Reference Guide

Taurus Mini Super-S3. Dual-Bay RAID Storage Enclosure for two 2.5-inch Serial ATA Hard Drives. User Manual March 31, 2014 v1.1

EcoEntry. RFID Proximity Access Control System. User Guide. Revision 2

SMK585 1U rackmount. With 8 Ports KVM Switch

4 / 8 / 16 PORT PS2 KVM SWITCH USER S MANUAL

Installation Manual. Model: HILU Ultra HD Interactive Flat Panel Display

Deluxe In/Out Remote Thermometer with Trend Chart

Transcription:

D1265 EN Installation Guide Touchscreen Keypad

D1265 Installation Guide 1.0 Introduction Contents 1.0 Introduction...3 1.1 Overview...3 1.2 Graphical Buttons...3 1.3 Audible Tones...4 1.4 Supervision...4 1.5 Tamper Switch...4 2.0 Installation...5 3.0 Setup Menu...6 3.1 Set the Keypad SDI Bus Address...6 3.2 Adjust the Keypad Volume and Display...6 3.2.1 Adjust the Keypad Volume...6 3.2.2 Turn the Button Click On or Off...6 3.2.3 Adjust the Display Brightness...7 3.2.4 Screen On Time...7 3.3 Saving Changes and Exiting the Setup Menu...7 4.0 RPS Configuration...7 4.1 Start RPS...7 4.2 Enable the Keypad...7 4.3 Enter Security Company Information...8 4.4 Update and Reset the Control Panel...9 5.0 Specifications...9 FCC This device can be expected to comply with Part 15 of the FCC Rules provided it is assembled in exact accordance with the instructions provided with this kit. Operation is subject to the following conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received including interference that may cause undesired operation. 2 Bosch Security Systems, Inc. 11/11 F01U169129-05

. 1.0 Introduction 1.1 Overview The D1265 Touchscreen Keypad is an SDI bus device and it is compatible with the Bosch GV2, GV3, and later, families of control panels: D9412GV3, D7412GV3, and D7212GV3 D9412GV2, D7412GV2, and D7212GV2 Figure 1: 1 1 - Touchscreen area 2 - Speaker D1265 Touchscreen Keypad 2 D1265 Installation Guide 1.0 Introduction 1.2 Graphical Buttons Refer to Table 1 for descriptions of the D1265 s graphical buttons. Table 1: Graphical Button to Graphical Button Descriptions Description Press this button to see onscreen help instructions. Press this button in combination with one or two numeric buttons to perform a function. Press this button to complete the entry of your passcode at the keypad. Press these buttons to enter numeric values. Press this button to see a list of available functions. Press this button to scroll back through the function menu. Press this button to scroll forward through the function menu. Press this button to exit the function menu. The control panel supplies all power and data requirements for the D1265 through a four-wire connection. To determine if you need an additional power supply, refer to the Current Rating Chart for Standby Battery Calculations provided in the approved applications compliance guide for the specific control panel used with the D1265. Bosch Security Systems, Inc. 11/11 F01U169129-05 3

D1265 Installation Guide 1.0 Introduction 1.3 Audible Tones The D1265 Touchscreen Keypad has a built-in speaker that produces several distinct warning tones. You cannot connect external annunciation devices to the D1265. Anytime the D1265 emits an audible tone, the keypad illuminates. Silence the audible tones in Table 2 by entering a programmed passcode with the appropriate authority, or [COMMAND] + [4] unless otherwise noted. Table 2: Tone Fire Signal Burglary Signal Entrance Warning Exit Warning Invalid Button Buzz Keypad Encoding Tone Trouble Buzzer Watch Tone Audible Tones Description When an area is in fire alarm, the keypad emits a pulsed, high-pitched bell tone. When an area is in alarm, the keypad emits a steady, high-pitched bell tone. The keypad emits an intermittent beep tone during entry delay periods to remind the user to disarm the area. The keypad emits an intermittent beep tone during exit delay. When an invalid button, or sequence of buttons, is pressed, the keypad emits a flat buzz tone. The keypad emits a muted beep tone as each button is pressed to indicate that the entry was accepted. To disable this feature, refer to Section 3.2.2 Turn the Button Click On or Off on page 6. When a trouble event occurs, such as a service alert, the keypad emits a two-tone warble until you enter [COMMAND] + [4]. When you activate the Watch feature ([COMMAND] + [6]), a single clean tweedle tone alerts the user anytime a watch point is faulted. This option is programmable by point. To disable the Watch Feature, press [COMMAND] + [6] again. 1.4 Supervision You can program the control panel to send messages identifying the supervised keypad to the central station receiver. To supervise a keypad, refer to the program entry guide for your control panel. If a keypad loses communication with the control panel for more than 15 sec, the keypad buzzes and the Call for Service message appears. Other keypads connected to the system show Service Keypad. The control panel sends a serial device trouble report to the receiver. The keypad shows SDI FAILURE # if the Modem IIIa 2 communication format is used. For more information, refer to the D6600 Computer Interface Manual (P/N: 4998122703). 1.5 Tamper Switch When the tamper switch is activated, the keypad sends a message to the control panel. Regardless of whether the control panel supervises the keypad or not, if the keypad s tamper switch activates, the Call for Service message appears. The tamper switch activates when someone or something pulls the D1265 away from a flat surface. Refer to Figure 4 and Figure 5 on page 5 for the location of the enclosure knockout and the tamper switch. 4 Bosch Security Systems, Inc. 11/11 F01U169129-05

. 2.0 Installation The D1265 Touchscreen Keypad is a low-profile, surface-mounted unit. Avoid installing the D1265 in direct sunlight. Direct sunlight can interfere with display screen visibility, and can damage internal components. Avoid installing the D1265 in wet or moist locations. 1. Unlock the keypad by turning the lock counter-clockwise. Refer to Figure 2. Figure 4: 1 2 D1265 Installation Guide 2.0 Installation D1265 Keypad (Back view) Figure 2: Unlock the Keypad 1 - Tamper switch 2 - Terminal block connectors 3. Use the base as a template to mark the desired mounting surface. Refer to Figure 5 for mounting hole and wiring locations. Figure 5: D1265 Base 5 2 3 1 1 9 6 7 8 2. Hold the keypad by the base in one hand. With the other hand, gently push down on the keypad to remove it from the base. Refer to Figure 3. 5 6 4 5 9 Figure 3: Remove the Keypad from the Base 10 1 1 5 3 2 1 - Wall mount holes 2 - Single gang box holes 3 - Dual gang box holes 4 - Wire opening 5 - Alternate wire openings 6 - Wire channel 7 - Tamper switch knockout 8 - Bubble level 9 - Wire tie posts 10 - Terminal block Bosch Security Systems, Inc. 11/11 F01U169129-05 5

D1265 Installation Guide 3.0 Setup Menu 4. Pull the wiring through the desired wire opening in the base. 5. Use the appropriate mounting hardware (not supplied) to mount the base to the desired mounting surface. 6. Connect the keypad to the control panel as shown in Figure 6. Figure 6: Wire Connections 1 3.0 Setup Menu To enter the setup menu, press and hold the 0 button for at least 5 sec. The setup menu opens. Use the D1265 s setup menu to: Set the keypad s SDI Bus address Adjust the keypad volume and display brightness Turn the button click tone on or off Set the screen on-time Figure 7: D1265 Setup Menu RYGB 2 EVICE CONNECTIONS POWER + 32 DATA BUS A 31 DATA BUS B 30 COMMON 29 1 - D1265 Base 2 - Control panel peripheral device terminals 3 - POWER + to R wire connection 4 - DATA BUS A to Y wire connection 5 - DATA BUS B to G wire connection 6 - COMMON + to B wire connection 7. Reconnect the keypad to the base by sliding the keypad onto the base (reverse of Step 2). The keypad automatically locks onto the base. 8. Apply power to the system. 3 5 6 4 3.1 Set the Keypad SDI Bus Address To set the keypad s SDI Bus address, press the Up or Down arrow buttons until you reach the desired address (1 to 32). Each SDI bus device must have a unique address assigned to it. 3.2 Adjust the Keypad Volume and Display 3.2.1 Adjust the Keypad Volume To adjust the keypad s volume, press the Up or Down arrow buttons until you reach the desired level (0 = silent; 10 = loudest). This setting only applies to normal interaction with the keypad. Alarms always sound at the loudest volume setting. 3.2.2 Turn the Button Click On or Off To turn the button click tone on, press the Up arrow button. To turn the button click tone off, press the Down arrow button. 6 Bosch Security Systems, Inc. 11/11 F01U169129-05

. 3.2.3 Adjust the Display Brightness To adjust the keypad s display brightness, press the Up or Down arrow buttons until you reach the desired level (1 = darkest; 15 = brightest). 3.2.4 Screen On Time To adjust how long the keypad display stays on, press the Up or Down arrow buttons until you reach the desired time (1-15 min). If there is no keypad activity within the specified duration, the keypad goes into sleep mode. In this mode, the keypad display is dark. 3.3 Saving Changes and Exiting the Setup Menu When you are done making changes in the setup menu, press the Save button. To exit the setup menu, press the Back button. The keypad returns to the normal display. 4.0 RPS Configuration To configure the D1265, RPS version 5.12 or later is required. 4.1 Start RPS For complete instructions on using RPS to program a control panel, refer to the RPS Online Help and the specific control panel s online help file in RPS. 1. Start RPS. 2. Enter a valid username and password. 3. Open the desired control panel account. D1265 Installation Guide 4.0 RPS Configuration 4.2 Enable the Keypad 1. In the Program Record Sheet, locate the section called COMMAND CENTER (GV2MAIN). This section is named the same whether you are in a GV3 or a GV2 account. Figure 8: RPS: COMMAND CENTER (GV2MAIN) 2. In the Cmd Ctr Assignments pane, locate Enhanced Command Center. Figure 9: RPS: Enhanced Command Center 3. Change Enhanced Command Center for the desired keypad address to Yes. Figure 8 uses CC Address 1 as an example. Bosch Security Systems, Inc. 11/11 F01U169129-05 7

D1265 Installation Guide 4.0 RPS Configuration 4. In the Program Record Sheet, go to USER INTERFACE (GV2MAIN)>Command Center Functions. Set Display Revision Command 59 to E (Enabled). This setting allows the configuration changes for the D1265 to take effect. Figure 10: RPS: Display Revision CMD 59 2. Under Passcodes & Authority Levels: Select Users 201-249 for the D9412GV3 and D9412GV2 Select Users 51-99 for the D7412GV3, D7412GV2, D7212GV3, and D7212GV2 Figure 12: RPS: Passcodes & Authority Levels 4.3 Enter Security Company Information Use the following steps to enter your security company s name and phone number. The users see this information when they press the Help? button on the D1265, and then press the Security Co. Info. button. 1. In RPS, in the Program Record Sheet pane, expand the PASSCODES (RADXUSR1/RADXUSR2) section. Refer to Figure 11 (the D9412GV3 is used as an example). 3. Scroll through the list of users to User 249 for the D9412GV3 and D9412GV2. Scroll to User 99 for the D7412GV3, D7412GV2, D7212GV3, and D7212GV2. 4. Double-click the cell for User 249 or User 99. The User Name dialog opens. Figure 13: RPS: User Name Dialog Figure 11: RPS: PASSCODES (RADXUSR1/RADXUSR2) 8 Bosch Security Systems, Inc. 11/11 F01U169129-05

. 5. Enter the security company s phone number and click OK. The new number appears in the appropriate User cell. Figure 14: RPS: User Name Change 4.4 Update and Reset the Control Panel 1. When you are done with RPS, click the Save button. If RPS is not already online with the control panel, start a communication session and send the programming changes to the control panel. 2. When you are ready to end the online session, click the Disconnect button and check the Rest Panel box on the End Session dialog for the programming changes to take effect. D1265 Installation Guide 5.0 Specifications 5.0 Specifications Table 3: Nominal Voltage Wiring D1265 Specifications 12 VDC Maximum resistance 11 Ω Standby Current Idle: 135 ma Dimensions (H x W x D): Weight Environmental Operating Temperature Relative Humidity Enclosure Color Enclosure Material Max*: 300 ma 12.2 cm x 12.0 cm x 3.0 cm (4.8 in. x 4.7 in. x 1.2 in.) 0.24 kg (8.5 oz.) Intended for indoor use 0 C to +49 C (+32 F to +120 F) 85% + 2% @ +49 C (+120 F) Bosch White Plastic (ABS) * With speaker and display backlight at maximum. Figure 15: RPS End Session Dialog 3. To close RPS, click the X button in the upper right corner twice. Bosch Security Systems, Inc. 11/11 F01U169129-05 9

Bosch Security Systems, Inc. 130 Perinton Parkway Fairport, NY 14450 USA www.boschsecurity.com Bosch Security Systems, Inc., 2010