Flow chart of bar code reader setting

Similar documents
Start Configuration. Chap.1 System Information. Set All default

NC-1200 BARCODE SCANNER. Configuration Guide - 1 -

BARCODE SCANNER. Configuration Guide - 1 -

Correction for Tab barcode. Add Function key emulation barcode

PureScan - ML1. Configuration Guide. Wireless Linear Imager Wireless Laser scanner - 1 -

Table of Contents Sleep Settings How to Configure the Scanner. 7 Chapter 2 System Setup

广州虹源电子有限公司. Guangzhou Hong yuan Electronic co.,ltd. Configuration Manual

Programming. User s Manual. Ver:3.2. Contents - 1 -

2D BARCODE SCANNER CA-SC-20200B

Programming User s Manual

COPYRIGHT 2009,SCSC. Manual P/No: SCCM - 80S-01A Released Date: Oct 31, 2009

Setup Procedures 2 Batch Setup 3. Bar Code Setup Menu 5. 1 Device Selection and Default. 2 Beep and Delay Keyboard Wedge..

Laser Barcode Scanner ARP Nr User s Manual

FD-011WU. 2D Barcode Reader User Guide V1.6CC

DLL2020. Software Configuration Manual

User s Manual. Xi3000 Scanner. Table of Contents

Configuration Manual PULSAR C CCD SCANNER. Table of Contents

Xi2000-BT Series Configuration Guide

MK D Imager Barcode Scanner Configuration Guide

BARCODE SCANNER. FUZZYSCAN FAMILY Quick Start Guide

marson MT8200S 2D Handheld Scanner User Manual V / 6 / 25 - I -

Getting Started Setup Procedures

Manual de Programación

SPEECHMIKE TM PHI BARCODE READER PROGRAMMING MANUAL PRO READER

Hand Held Linear Imager

2D Barcode Reader User Guide V 1.2.1

NT-1200 CCD Wired Barcode Scanner Overview

ZBX P/N : MUL LASER LIGHT CAUTION DO NOT STARE INTO BEAM

Installation- Keyboard Wedge

GS100. CCD Barcode Scanner. User Manual

User s Guide. Linear Imager

MD5 Series Barcode Scanner

If you want to do other configurations please refer to below programming barcodes.

Specification or version may be subject to change without notice. The actual specification and version are based on the product delivered.

CCD - 75 USB. Programming Manual. GOMARO s.a. - Z.I. La Rosaire 5 - CH Aclens

Introduction FCC Statement

Product Engineering Specification Scan Utility

Manuel de programmation du lecteur LDT75C ver 2.1

CCD-BARCODE SCANNER. Programming Manual. To program the device, scan the following codes: FIRST: start configuration %$ + / 0

ZB-8150/ZB-8110/ZB-8210 CCD BARCODE SCANNER. User s Manual. ZBA Inc 249 Homestead Rd Unit 12 Hillsborough NJ 08844

Table of Contents. Introduction Installation Pin Assignments Method of Programming Setup Commands... 9

BD-6500BT Bluetooth 2D Barcode Scanner Configuration Guide

User s Manual. Addendum to. Ranger Wedge Interface. Part No. 25-WEDGE-06A Ver. April 1999

Menu & commands booklet FOR BAR CODE SCANNERS * *

DelfiScan C70. Programming Manual

Wireless 2D Pocket barcode scanner

BAR CODE. SYMBOLOGY PROGRAMMING for POCKET SCANNERS

Wired Laser Barcode Scanner User Manual V:1509

AS-8050 CCD Scanner User Guide

Wearable 2D Pocket barcode scanner

Datalogic Scanning, Inc. 959 Terry Street Eugene, Oregon Telephone: (541) Fax: (541)

MD22xx Barcode Scanner

Area Imager Bar Code Scanner 2 D C O N F I G U R A T I O N G U I D E

Introduction. Installation- Keyboard Wedge

Delivery content * Pocket Barcode scanner x 1 * Mini USB cable x 1 (for charging only) * Quick instructions x 1 * Strap x 1

MD65xx Image Barcode Scanner

1.1 Notice Introduction Codes Read Installation Pin Assignment Specification... 8

MD22xx Barcode Scanner

NOTICE: respective owner. Note: Specification is subject to changes without. notice.

Nuscan 3200 Optical Laser Barcode Scanner

C O N F I G U R A T I O N G U I D E

Omni-Directional Barcode Scanner Model No. OM7120

2D barcode scanner User Manual

Setting code User Manual

Z3S. Quick Setup Guide V Connection Mode. Working via Bluetooth. Barcode Programming. Working via USB cable

If you want to do other configurations please refer to below programming barcodes.

1. Factory Default Se ng (include below three steps)

Wireless 2D Pocket barcode scanner

Delivery content * Pocket Barcode scanner x 1 * Mini USB cable x 1 (for charging only) * Quick instructions x 1 * Strap x 1

QuickScan QS2500 Handheld Bar Code Scanner

Lecture (09) x86 programming 8

IPDA014-2D. Embedded 2D Barcode Scan Engine. User Guide

Innovation By Design

Table of contents. Change scanner settings Factory default settings Default message format Programming flow chart

MP720 Presentation Imager

Programming with barcodes

MP168 Screen Barcode Image Platform

C O N F I G U R A T I O N G U I D E

MP80xx Image Platform

If you want to have other configurations please refer to below programming barcodes. Check Scanner Version

Preliminary draft_1. Prefix Scanned Data Suffix. Intercharacter Delay. Intercharacter Delay

Manual POSline SC2120/SC2130/SC2140 1D & 2D Barcode Reader User's

Serial Dongle RS232 Plug&Scan

PS232. RS-232 to PS/2 Keyboard Port Adapter Part # SA0009 (Version 4.0) Copyright 2003 L3 Systems, Inc. Redmond

Pock et b arcod e s cann er

Advanced Handheld High-Speed Laser Scanner

ValueScan II TM Barcode Scanner. User s Manual rev.a

000A1 Display inward character string(custom) USB-HID Single not triggered Not:CCD inapplicability Continuous Scan Mode

Barcode BC-29. Decoder & Platform. Programming Manual

Barcode reader setup manual

A GUIDE TO RS-232 COMMUNICATION WITH FX PLCS

MD60xx Image Barcode Scanner

El5220. Image Platform. User Manual

Factory Default Configuration. Factory Default Configuration

2D Hand-held Barcode Scanner User Guide

Addmaster Corporation

Connecting UniOP to Datalogic Barcode Readers

POSSAFE LQ300 BARKOD OKUYUCU. Configuration Manual

S-Series Sensor ASCII Protocol v8.1.0

nlscan.com Tools Exposure Imaging Mode ** Normal Exposure Mode Pro CMD Reflections Eliminating Mode Pro CMD Page 36

Transcription:

Chapter 1.System information 1.1Restoration of initial value... 3 1.2 Software version display... 3 1.3 Product serial number display... 3 Chapter 2.System setting 2.1Interface type selection... 4 2.1.1Protocol type mode... 5 2.1.2 RS-232 Interface setting...10 2.2 Scan mode setting...14 2.3 Sound setting...17 2.4 String character setting...18 2.5 Other settings...20 Chapter 3.Bar code setting 3.1 UPC-A... 22 3.2 UPC-E...24 3.3 EAN-13... 26 3.4 EAN-8... 28 3.5 Code 39... 30 3.6 Codabar... 33 3.7 Code 93... 35 3.8 Code 128/EAN-128... 37 3.9 Interleaved 2 of 5... 39 3.10 Industrial 2 of 5... 41 3.11 Matrix 2 of 5...43 3.12 China post code... 45 3.13 MSI/Plessey... 47 3.14 Code 32... 49 3.15 Code 11... 51 3.16 RSS(optional) Appendix A... 53 Appendix B... 55-1 -

Flow chart of bar code reader setting /!0 1243 5 687 6 9:2 2 :2 9<; 6 3 3 : 2 9>=? 3 5 687 1@ 0 = A6 B +)!#"(!)!*+%!$! &' C!#!+D - %!#&' %!*E*!F!C!- *!$ )!G"!#!$!G&!#!D, [\ ] ^ _ ` \a b c ^ _ ` dee b ` b f\ ^ \ ` S<Q!Q!I#!$!- RJ,!D D - #I.!,J*!FIC!- *!$ i = gh!, B +)!#"D H8%"' -.IC!*!,J%I'K<L8M<N OP' * %!G )!Q!Q!!#!$!- RTS UV,W#!D!!,- X "D %&)!#"S B<Y8Z Z +%!$!! "!#!$&%!'!(!)!* +%!$! ",+)!#!#!- #!.! "!#!$&%!'!(!)!* +%!$! ",+)!#!#!- #!.",ID D - #!.!, Remark Display software version number, direct bar code scanning software version number. Display product serial number direct bar code scanning product serial number. - 2 -

Chapter 1System information 1.1 Restoration of initial value System setting will be reset and restored to factory initial state through bar code scanning. 1.2 Software version display Display software version number through bar code scanning. 1.3 Product serial number display Display product serial number through bar code scanning. Set begin Restore the factory parameter Software version number Reserved (product serial number) - 3 -

Chapter 2 System setting 2.1 Interface type selection This type of bar code reader can support 3 kinds of interface User can reset according to their needs It is to be noted that the bar code reader can only read data into the mainframe if the on-line access to the interface is consistent with the settings. USB protocol used HID type of keyboard so related-settings of keyboard also apply to USB interface If applying to other interface lines upon the USB interface has set feature setting still can be carried on but not the transmission of data or else it will result to shut down If the interface from other settings applied to USB interface procedures need to be restarted when the set ended scanner should re-plug the electric Prior to scan, it is critical to ensure that the equipment is complete Set begin Keyboard (default) RS-232 Interface selection USB - 4 -

2.1.1 Keyboard interface parameters Keyboard protocol type Select the type of host to connect the keyboard Select bar code interface according to the host interface cable Set begin IBM AT(default) IBM XT IBM PS/2 30-80 IBM 5550 Protocol type keyboard PS/2 25 30 NEC 9801 Reserved Reserved - 5 -

Keyboard language selection: It doesn t only support American-style keyboard but also a variety of languages. Set begin America default Italy Italy France Language option Germany Japan Reserved Reserved - 6 -

Function key emulation (IBMAT) When the bar code contains 01 to 1F of the ASCII code value if it is set to bar code reader outputs corresponding code it is equal to pressing a function key Direct scanning of bar codes in Appendix B can also implement function key simulation. Keyboard simulation: It is suggested to turn on this function in order to start the PC normally, even if the keyboard hasn t installed yet ALT mode ALT mode simulation Set begin OFF (default) Function key OFF(default) Keyboard emulation OFF(default) ALT mode - 7 -

Caps Lock key This function key is related to the Caps lock key of the keyboard function upon switched on it is equal to pressing the Caps Lock key Num Lock key This function can only be effective to PC/ AT upon switched on, it is equal to pressing the Num lock key of the keyboard Inter-character delay(for the keyboard interface) Upon sending a character, it inserts a delay delay time=set of data*1(ms) Set begin OFF(default) Caps Lock key Num Lock key OFF(default) A 00 64H Inter-character delay(default 00) - 8 -

Keyboard data end mark (for the keyboard interface) Keyboard interface of the bottom of the output data Delay after each data transfer section(for the keyboard interface) Delay timer, which is an output of each bar code data This feature is generally used to send frequent short bar code data or to transmit multi- bar codes at once, delay time = data set*100(ms) Keyboard speed select the host which matches its speed Set begin None CR(default) Tab Data at the end of the keyboard ESC CR + LF A 00 0AH A 00 08H After each data transfer delay (default 00) Keyboard speed (default 00 High clock) - 9 -

2.1.2 RS-232 Interface setting RS-232 Basic setting of communication protocols including baud rate, data bit, stop bit, calibration, etc Set begin 1200bps 2400bps 4800bps Data bit 9600bps(default) 19200bps 38400bps 7digits Transmission baud rate 8digits(default) - 10 -

Set begin 1digit(default) Stop bits 2digits None(default) Odd parity Check setting Dual check Mark check Space check RS-232 function setting At RS-232 interface mode the client can proceed the following aspects according to own requirements (including the suffix data flow control protocol in response to delay, etc.) Inter-character delay(for RS-232): Each data time delay between output characters Delay time=data set*1(ms) - 11 -

Delay after each data transmission(for RS-232):Each bar code data output a delay timer This feature is generally used to send frequent short bar code data or transmission of multiple bar codes simultaneously, the delay time set data = * 100 (ms) Protocol response delay Wait for host handshake signal time, delay time = set data * 100 (ms) Set begin Appendix A (00 64H A 00 0AH Inter-character delay (default 00) Delay after each data transfer default 00) Protocol response delay default 00) A 00 0AH None(default) RTS/CTS Flow control ACK/NAK Xon/Xoff - 12 -

Set begin None CR+LF default CR LF Data suffix Tab STX/ETX EOT - 13 -

Set begin None(default) RTS/CTS Flow control ACK/NAK Xon/Xoff 2.2 Scan mode setting Button switch mode: Hold down the trigger to begin scanning scanning would be completed upon the trigger released or when the scan decoding is successful When it is successful release the trigger then hold it down again will begin the next decoder Turn OFF mode after identification: Hold down the trigger and start scanning when the scanning duration time is up or bar code scanning is finished scanning process will come to an end Continuous/Button clearance mode: Hold down the trigger and start continuous scanning can continuous scan different bar code but same bar code will only be read once yet the same bar code - 14 -

could be re-read after the light disappeared. Hold down the trigger to stop the continuous scanning Test mode: Hold down the trigger to start testing continuous scanning the barcode hold down the trigger again to stop the testing Each time the trigger has been held down, it only read once it only could be changed to another way through scan mode to exit. Continuous recognition/timeout Off Scan mode and continuous / key clearance model, as provided for the Timeout time, in the absence of a successful scan, exit and turn off the light, once again press the trigger, to restart scanning. Timeout time setting mode Scan continuous reading/timeout Off bar code Scan two hexadecimal digits as a time value from A Scan OFF bar code from A Scan bar code to finish the setting Timeout setting uses seconds as a unit, for example, 0x40 expresses one minute, Timeout value for the initial 0xB4, around 3 minutes. - 15 -

Set begin Button switch mode turn OFF mode after identification(default) Continuous recognition/ Guan mode key Test reading mode Scan mode Continuous recognition/led Continuous recognition/timeout off Scintillation Continuous recognition/no Trigger - 16 -

2.3 Sound setting You can adjust the level of buzz and beep tone regulation time. It is allowed to set the boot sound, as well as decode it. Set begin A(00-10H) Audio setting duration 0AH A(00-10H) Duration setting default 05H default Boot voice prompts OFF default Sound prompts OFF - 17 -

2.4 String (character) setting Prefix suffix string setting A max. of 10 ASCII characters could be added before or after the bar code data No action can be done if it is set to 0. Format as follow Prefix string Bar code data Suffix string character character Steps for adding Prefix/ Suffix to all bar code symbols Scan start set up and set prefix string bar code table of ASCII code find the prefix / suffix ASCII value Scan the ASCII value of the bar code through Bar code scan ends Bar code scan setting ends Insert the G1/G2 group of characters Each group can add a max. of 10 ASCII, characters can t be inserted when it is set to 0 Steps in inserting characters Scan set up start and insert character barcode to G1 Check the table of ASC11 look for the ASCII value of the character Scan the bar code of ASCII value through the Scan the end bar code through the Repeat the same steps for inserting the G2 group characters Scan end set up bar code. Insert character location to G1/G2 group Choose a group of character and insert to the location of bar code when it is set to 0 although you do not set up to group of 0 characters still can not be inserted to bar code data Scan start set up and insert character location bar code to G1-18 -

Check the table of ASCII Look for the ASCII value of the corresponding insert location Scan the end bar code through A Repeat the same steps for inserting G2 group character location Scan end set up Send barcode If your application needs to send code (bar code type of ID), you must set the format : ID + barcode information. - 19 -

Set begin A A A A A A Set prefix characters default 00 Set suffix characters default 00 default 00 G1Insert character G2Insert character default 00 G1Insert character location default 00 G1Insert character location default 00 Send code OFF default - 20 -

2.5 Other setting Scan accuracy Can be set to scan once or twice then transmit bar code it could be set to twice in order to reduce errors. Bar level setting Input level to set up through the bar signals noted that level must match in order to decode This setting resolves when the anti-white bar code occurs and the decoder cannot decode Set begin Scan once then transmit default Scan accuracy Scan twice then transmit Bar = HIGH default Bar level setting Bar = LOW (default) Laser Data Accelerate reader OFF - 21 -

Chapter 3 Bar code option Read When the selection is on such bar code can be decode as well as transmitted or couldn t be read nor transmitted Set code Necessary type of barcode ID could be set the send code project must set to open in order to send the ID. Set code steps Scan setting and set barcode Check the table of ASCII find the code you wan t to set in correspond to ASCII code Scan end barcodes of Scan end set Calculation of parity bit Calculate barcode checksum value check the accuracy of decoding. Send parity bit Send the bar code checksum value which can be set to open and close Before the median cut-off when set to 0 it won t delete the bar code in front of the data set up the steps to the steps to set up code. After the median cut-off when set to 0 it won t delete the bar code behind the data set up the steps to the steps to set up code. Select insert group Set the range of 0-2 characters can t be inserted when it set to 0 Set up characters from G1/G2 insert character set up insert location from G1/G2 character location set up Set up the steps according to set up code. Min. length Set a minimum length of a barcode it can t be decoded if the barcode is less than this length Set up the steps according to set up code. Max. length Set the maximum length of a barcode, it can t be decoded if the barcode is greater than this length Set up the steps according to set up code. If the maximum length is equal to minimum length, the length of the bar code is a fixed number. Supplementary code reader EAN code has 2 or 5-22 -

supplementary code you need to select setting according to the type of supplementary code needed. Truncate pre-0 : delete the bar code before the 0. 3.1UPC-A Parameter setting UPC-A convert to EAN-13 To convert UPC-A to EAN-13 add 0 in front of the bar code data Set begin OFF Read (default) A(20-7EH) Set code (default F) OFF (default) UPC-A convert toean-13 OFF Send parity bit (default) - 23 -

Set begin OFF default Truncate pre-0 A(00-0DH) Before median cut-off A(00-0DH) After median cut-off A 00-02H Insert group selection None (default) 2digits Supplementary reader code 5 digits 2 or 5digits - 24 -

End set up 3.2UPC-E Parameter setting UPC-E convert to UPC-A converting 8-digts UPC-E to 12-digits UPC-A Set begin OFF Read (default) A(20-7EH) Set code (default G) OFF(default) UPC-E convert to UPC-A OFF Send check (default) A(00-08H) Before median cut-off - 25 -

Set begin A(00-08H) After median cut-off A(00-02H) Insert group selection OFF Truncate pre-0 (default) None(default) 2digits Supplementary reader code 5digits 2 or 5 digits - 26 -

3.3 EAN-13 Parameter setting Set begin OFF Read (default) A(20-7EH) Set code (default:h) OFF Send check code (default) A(00-0DH) Before median cut-off A(00-0DH) After median cut-off - 27 -

Set begin None(default) 2digits Supplementary reader code 5digits 2 or 5digits ISBN/ISSN conversion OFF (default) A(00-02H) Insert group selection - 28 -

3.4 EAN-8 Parameter setting Set begin OFF Read (default) A(20-7EH) Set code (default:i) OFF (default) Send characters checksum A(00-08H) Before median cut-off (Default:00) - 29 -

Set begin A(00-08H) After median cut-off digit None(default) 2digits Supplementary reader code 5digits 2 or 5digits A(00-02H) Insert group selection - 30 -

3.5 Code39 Parameter setting Set begin OFF Read (default) A(20-7EH) Set code (default:j) OFF(default) Check OFF Send checksum characters (default) - 31 -

Data tandem Code39 Format: The wholeasiicode39 are enhanced 39code which included a total of 128characters corresponding to 128 ASCII code CODE 32 Read Open to read CODE 32 Set begin OFF(default) Data tandem A(00-32H) A(00-32H) Min. length Max. length (default:32h) Standard (default) Code39 Format Multi-featured Code39-32 -

Set begin OFF (default) Send start / End character A(00-32H) A(00-32H) A(00-02H) Before median cut-off After median cut-off Insert group selection End set up - 33 -

3.6 Codabar Parameter setting Set begin OFF Read (default) A(20-7EH) Set code(default :K) OFF Check (default) OFF(default) Send checksum character OFF(default) Data tandem - 34 -

Set begin A(00-7EH) Before median cut-off A(00-7EH) After median cut-off ABCD/ABCD(default) Send start / End character abcd/abcd abcd/tn*e OFF(default) Send start / End character A(00-3CH) Min. length A(00-3CH) Max. 3CH) length(default: A(00-02H) Insert group selection - 35 -

3.7Code93 Parameter setting Set begin OFF Read (default) A(20-7EH) Set code (default:l) OFF Check (default) - 36 -

Set begin OFF( default ) Send characters checksum A(00-50H) A(00-50H) A(00-7EH) Min. length ( default :00) Max. length ( default :00) Before median cut-off ( default :00) A(00-7EH) After median cut-off ( default :00) A(00-02H) Insert group selection - 37 -

3.8Code 128 Parameter setting Set begin OFF Read ( default ) A(20-7EH) Set code ( default :M) OFF Check ( default ) OFF( default ) Send checksum characters A(00-02H) Insert group selection ( default :00) - 38 -

Set begin - 39 -

OFF( default ) FNC2 tandem OFF( default ) UCC/EAN128 OFF( default ) Send FNC1 A(00-7FH) Before median cut-off ( default :00) A(00-7FH) After median cut-off ( default :00) A(00-7FH) Min. length ( default :00) A(00-7FH) Max. length (default:7fh) - 40 -

3.9 Interleaved 2 of 5 Set begin OFF Read (default) A(20-7EH) Set code (default:n) OFF(default) check OFF Send checksum characters (default) - 41 -

Set begin A(00-7EH) Before median cut-off A(00-7EH) After median cut-off A(00-7FH) Min. length A(00-7FH) Max. length (default:7fh) A(00-02H) Insert group selection - 42 -

3.10 Set begin Industrial 2 of 5 Parameter setting OFF(default) Read A(20-7EH) Set code (default:o) A(00-32H) Min. length A(00-32H) Max. length (default:32h) - 43 -

Set begin A(00-32H) Before median cut-off A(00-32H) After median cut-off OFF(default Check OFF(default) Send checksum characters A(00-02H) Insert group selection - 44 -

3.11 Matrix 2 of 5 Parameter setting Set begin OFF (default) Read A(20-7EH) Set code (default:p) OFF (default) Check - 45 -

Set begin OFF Send checksum characters (default) A(00-50H) Before median cut-off A(00-50H) After median cut-off A(00-50H) Min. length A(00-50H) Max. length (default:50h) A(00-02H) Insert group selection - 46 -

3.12 China post code parameter setting Set begin OFF (default) Read A(20-7EH) Set code (default:q) OFF(default) Check OFF(default) Send checksum characters - 47 -

Set begin A(00-50H) Before median cut-off A(00-50H) After median cut-off A(00-50H) Min. length A(00-50H) Max. length (default:50h) A(00-02H) Insert group selection - 48 -

3.13 MSI/Plessey Parameter setting Set begin OFF(default) Read A(20-7EH) Set code (default:r) OFF (default) MOD 10 Check MOD 10/10 MOD 11/10-49 -

Set begin OFF Send checksum characters (default) A(00-3CH) Before median cut-off A(00-3CH) After median cut-off A(00-3CH) Min. length A(00-3CH) Max. length (default:3ch) A(00-02H Insert group selection - 50 -

3.14 CODE 32 Parameter setting Set begin OFF default Read A(20-7EH) Setting code (default :R) OFF Check ( default) OFF Send parity bit default - 51 -

Set begin A(00-0AH) A(00-0AH) A(00-02H) Before median cut-off After median cut-off Insert group selection - 52 -

3.15 Code 11 Parameter setting Set begin OFF(default) Read A(20-7EH) Install code (default:t) OFF check (default) - 53 -

Set begin OFF(default) Send checksum characters A(00-50H) Before the median cut-off A(00-50H) After the median cut-off A(00-50H) Min. length A(00-50H) Max. length (default:50h) A(00-02H Insert group selection - 54 -

- 55 -

Appendix A ASCII barcode OFF end set up - 56 -

Table of ASCII 0 1 2 3 4 5 6 7 0 NUL DLE SP 0 @ P ` p 1 SOH DC1! 1 A Q a q 2 STX DC2 2 B R b r 3 ETX DC3 # 3 C S c s 4 EOT DC4 $ 4 D T d t 5 ENQ NAK % 5 E U e u 6 ACK SYN & 6 F V f v 7 BEL ETB 7 G W G w 8 BS CAN ( 8 H X h x 9 HT EM ) 9 I Y i y A LF SUM * : J Z j z B VT ESC + ; K [ k { C FF FS, < L \ l D CR GS - = M } m } E SO RS. > N ^ n ~ F SI US /? O _ o DEL - 57 -

Appendix B Table of function key emulation 0 1 0 NULL 1 UP F1 2 DOWN F2 3 LEFT F3 4 RIGHT F4 5 PAGE UP F5 6 PAGE F6 DOWN 7 F7 8 BS F8 9 TAB F9 A F10 B HOME ESC C END F11 D ENTER F12 E INSERT F DELETE - 58 -

Function key emulation barcode Before scanning the barcode turned the multi-featured function CODE 39 UP($A) F1($Q) DOWN($B) F2($R) LEFT($C) F3($S) RIGHT($D) F4($T) PAGE UP($E) F5($U) PAGE DOWN($F) F6($V) F7($W) BS($H) F8($X) TAB($I) F9($Y) - 59 -

F10($Z) HOME($K) ESC(%A) END($L) F11(%B) ENTER($M) F12(%C) INSERT($N) F13(%D) DELETE($O) F14(%E) - 60 -