ACT 5e prox Operating and Installation Instructions ACT Product Code: ACT 5e prox

Similar documents
ACTsmart2 Product Range Operating and Installation Instructions

Installation & User Manual V1.0

ACTentry A5 Kit. ACTentry A5 Entry Panel. Audio Door Entry with Access Control. Audio Door Entry & Access Control Kit Features

pro ACTpro IOM INPUT/OUTPUT MODULE Installation and Configuration Instructions for the ACTpro IOM Input/Output Module ACT Product Code: ACTPRO IOM

ACTpro Single Door IP Controller. Operating & Installation Instructions

Digital Keypad Introduction

EZ-TAG2 Manual_Layout 5 11/12/ :14 Page 1 U S E R M A N UAL

VANDERBILT PRODUCT CATALOGUE

FTK5 PROXIMITY KEYPAD

ACTpro 1500 Single Door IP Controller

BACK-LIT KEYS KEYPAD 100 USER CODES FLUSH MOUNT

CV-550SPK V2 Waterproof Keypad/Reader/Controller Installation Instructions

April 2015 PRICE SCHEDULE A 2.0 Stand-Alone Access Control

F6-Fingerprint. Access Control/Reader. User Manual. F6 - Simplified Instruction. (Master Code) # (Factory default:1234) Enter the Programming Mode

Access Control Technology Ltd. reserve the right to change the contents of this manual and the system it applies to without prior notice.

Installation & User Manual V2.08

VIS-3200 / VIS-3201 User Manual

DG-800 Stand-Alone Proximity Reader Instruction Manual

Installation and User Manual

EL-ST100 KEYPAD CONTROLLER

W3-H Waterproof Keypad/Reader/Controller

CV-110SPK Standalone Keypad/Prox Access Control Installation Instructions

Single Door Standalone Access Control User Manual

RD-SR2 ACCESS SECURITY PRODUCTS LTD. Proximity Card Reader with Remote Control. User Manual

User Manual. PCKeypad Wireless Keypad

January 2013 PRICE SCHEDULE A 2.0. Access Plus Telephone Entry & Access Control

MODEL KP-100 ACCESS CONTROL DIGITAL KEYPAD OPERATING INSTRUCTIONS

EN FULL DETAILS SKB. Vandal Resistant keypad - Full Details

Standalone Keypad Access Control. User Manual. Please read the manual carefully before use this unit

CM-500 SK 500 USER CODES KEYPAD

Standalone Keypad Access Control. User Manual. SS-TS2000 Size:120*80*25 mm

EZTAG3 PROXIMITY AND KEYPAD DOOR ENTRY

EZTAG3 PROXIMITY AND KEYPAD DOOR ENTRY

INSTALLATION INSTRUCTIONS 921P EntryCheck TM

AUDIO AND VIDEO DOOR ENTRY SYSTEM WITH NEXA CODED PANEL

Contents Installation Instructions 3 Installation Diagrams System Overview Wiring Diagrams Network Diagrams

CM-110SK Standalone Keypad Installation Instructions

INSTALLATION INSTRUCTIONS 920P EntryCheck TM

Section A5. Standard Telephone Entry Systems. This Price Schedule is effective April 1, Date Page Comment

MULTI-DISCIPLINE READERS. ImproX Multi-discipline Readers INSTALLATION MANUAL SPECIFICATIONS MODEL NUMBER: MDR GB-XX MDK GB-XX

Waterproof. Keypad/Reader/Controller

Proximity Card and Pin Reader Installation Manual

Camden - Key Switches

ACCESS CONTROL SYSTEM

AS Keypad User Manual

VIDI-AC-2CS Access Controller/ Reader

DP2 DOOR PHONE. For Technical Assistance Please Phone: (07)

The Pyramid Series features five readers, each with its own unique characteristics, to meet virtually any requirements an end-user may have.

INSTRUCTION MANUAL DIGI-LOCK. Keyless Entry System. Installation. Programming. Troubleshooting. BASE Industries

Indoor/Outdoor Proximity Reader and Keypad with 10cm (4in) Read Range

UniScan. Impro UniScan Controller INSTALLATION MANUAL

For Powerful Digital Marketing and Total Multimedia Solution DV-6664 & DV-6664T. User s Guide version 1.0

SK-3133-PPQ Heavy-Duty Outdoor Access Control Keypad with Proximity Reader

CardaxFT Reader I/O Interface

K44 Code lock. Technical manual

Installation & User Manual

AGATA C200 UK A/200N TARGHA 200. Installation Manual AGATAKIT C 200 UK

PCR43304R, PCR43304RE 4-Channel, 433MHz Penta Receiver with Frequency Hopping

CP150B Vandal & Weather Resistant Keypad Security Systems

U-FLASH Setup Guide U-FLASH.

D O O R S T A T I O N W I T H P R O X I M I T Y R E A D E R

GV-EL124S Electric Strike

REX F-0-9 Standalone or Access Controller

ACTPRO ACCESS CONTROL. Specification Guide

VANDAL RESISTANT BACK-LIT WEATHERPROOF ACCESS CONTROL KEYPAD

Oracle (T M ) W ireless Keypad

W3-M. Metal waterproof standalone access control/reader. User Manual

Installation Instructions

Waterproof Exit Button x40x30/44mm - IP68, 304 Stainless Steel - Voltage: DC12V, DC9-24V (-W402N)

Wireless Key fob, Key pad & Receiver Range

C e l l C O M. G S M I n t e r c o m

ImproX IXP20 Controller INSTALLATION MANUAL

Cardax Prox Plus Mifare Reader

Pyramid Series Proximity Readers

Stand-alone Proximity Access Control

7612 Programming Instructions

IBA-7612 Programming Instructions

IEI emerge MicroNode Install and Setup Guide. Contents

Choose Cotag readers. ...For ultimate convenience and cost-efficiency.

DOLXFD1000B. Waterproof Access Control/Reader

Two Door Controller GEN-045

ROSSLARE AC-115. Hardware Installation and User s Guide DOOR MODE 10/01

212iL Rev. 1.1

Art. 4KC/ G Audiokit with digital codelock

-DTZ001- Stand-Alone Proximity Access Control. User Manual

Section 1 General Description. Section 3 How to Program Keypad. Section 2 Installation. CM-120TX Wireless Digital Keypads Installation Instructions

TOUCHLOCK compact keypad Stainless Steel

ACCESS CONTROL Products 2017

January 2018 PRICE SCHEDULE A 2.0 Access Control Devices

Access control panel U-Prox IC E (Elevator control)

EcoEntry. RFID Proximity Access Control System. User Guide. Revision 2

Fingerprint Access Control F1. User Manual

Installation Instructions

Operating Instructions KEYPAD. Compatible WIRELESS ACCESS CONTROL

Revision Date: 02 Mar 2018

FlexPass. ASR Long Range Reader. Installation Guide Jeronimo Road Irvine, CA July 16, 2007 Document Number K , Rev B

January 2019 PRICE SCHEDULE A 2.0 Access Control Devices

F-X20FO Fingerprint safe

DP2. Door Phone. For Technical Assistance call the Manufacturers direct ph AM - 5PM West Coast Pacific Time

INSTALLATION INSTRUCTIONS 920 EntryCheck TM

Transcription:

standalone ACT 5e prox Operating and Installation Instructions ACT Product Code: ACT 5e prox ACT 5e prox 2R.indd 1 19/02/2016 17:05:06

ACTstandalone Robust and Reliable. 1 ACT 5e prox 2R.indd 2 19/02/2016 17:05:08

Installation Notes Remember to Factory Default the ACT 5e prox before programming. Remember to place the supplied varistors across the terminals of the door strike coil to protect the relay contacts. Don t mount the ACT 5e prox unit near RF sources (e.g. mobile phones, radio transmitters, etc) or metal surfaces. Never use the on-board relays to switch AC mains voltage. An external relay, electrically isolated from the ACT 5e prox, should be used for this purpose. Remember to change the programming code. When ordering new cards or fobs specify ACTRFID. (Note: ACT 5e prox will NOT work with HID cards or fobs.) Important As with any Access Control system, always ensure there is an alternate means of escape in the event of the unit failing to operate due to power loss or in the event of fire. Product Specification Number of Users 50 (50 PINs and 50 Cards) Number of Relays 2 Supply Voltage 12-24V AC or DC Current Consumption 60mA (nominal), 130mA (maximum) Operating Temperature -10 to +50 degrees C Door Open Time 0-255 seconds Relay Contact Rating 5A / 50Vac Keypad Size Flush Mount: 100 x 110 x 20mm Surface Mount: 128 x 94 x 18.5mm Keypad Weight 220 grams Water Resistance High IP67 Construction Rugged Polycarbonate housing with stainless steel keys and potted electronics. Ordering Information Product Proximity card Proximity fob Proximity half shell card Proximity card with magnetic stripe Product Code ACTProx ISO-B ACTProx Fob-B ACTProx HS-B ACTProx DUO-B Copyright 2016 Access Control Technology Ltd. Part No.18-00094 Issue 1.1 2 ACT 5e prox 2R.indd 3 19/02/2016 17:05:08

30 Second Programming Guide 1. Enter Programming Mode. On the digital keypad press button 6. Input the programming code (default is 9999). The LED will flash amber. 2. Change User 1 Code On the digital keypad press button 0. Input 01 (for User 01). Input the new User 1 code (4 digits). 3. Add User 1 Card On the digital keypad press button 5. Input 01 (for User 01). Present User 1 s card twice. 4. Change Programming Code On the digital keypad press button 0. Input 4. Input the new programming code (4 digits). 5. Exit Programming Mode On the digital keypad press button 6. The LED turns red and programming mode has been exited. 6. Record User Code and Card Enter the details of the Users and their associated codes and card numbers on the User List provided in this manual. The ACT 5e prox is now ready for normal use. Note: The ACT 5e prox may be returned to its factory default condition at any time by entering the programming mode and pressing button 4 three times. 3 Copyright 2016 Access Control Technology Ltd. Part No.18-00094 Issue 1.1 ACT 5e prox 2R.indd 4 19/02/2016 17:05:08

Programming Summary Code Function Default 0 Change PIN code 1234 User 1, 9999 - Programming Code 1 Relay Combinations Timed Relay 1 2 Set Door Relay Time 5 seconds 5 Add User Card 6 Delete User s Card 7 Delete Card Number 30 Card or PIN On 31 Card or PIN Off 32 Card and any PIN Off 40 Permanent Backlight On 41 Auto Backlighting Off 80 Check User PIN 81 Check User Card Copyright 2016 Access Control Technology Ltd. Part No.18-00094 Issue 1.1 4 ACT 5e prox 2R.indd 5 19/02/2016 17:05:08

ACT 5e prox Programming On the digital keypad press the button 6 and input the programming code (initially 9999). The LED will flash amber while in programming mode. To exit the programming mode either press button 6 or do not activate any key for 30 seconds. If the LED flashes green during programming, then a card presentation is expected. If the LED flashes red, then a keypress is expected. While the ACT 5e prox is busy performing a task, (e.g. Defaulting memory, adding cards), the green led will turn on and the buzzer will sound an elongated tone. Changing User PIN Codes: Enter Programming Mode (69999), then press: Step Keypad Entry Operation Example: Assign code 7529 to user 7 1 0 Change PIN codes 0 Change PIN codes 2 00-49 Enter 2 digit User Number 00-49 07 User 7 3 0000-9999 4 digit code 0000 deletes User code 7529 PIN code *Remember to update the user list document at the back of this manual after adding a PIN or Card Adding Cards: Enter Programming Mode (69999), then press: Step Keypad Entry Operation 1 5 Add Card 2 00-49 First user to be assigned card 3 Present Card First Card (lowest number card) assigned to first user 4 Present Card Last Card (highest number card) assigned to last user Cards may only be assigned to users that do NOT have a card already assigned. When adding cards to the ACT 5e prox, check which users already have cards by using option 81 (see page 7). Example: Assign card 0000200036 to user 21: Keypad Entry Operation 69999 Enter programming 5 Add Card 21 User 21 Present card Card number 0000200036 Present card Card number 0000200036 6 Exit programming Example: Assign card 0000200036 to user 21 using the keypad: Keypad Entry Operation 69999 Enter programming 5 Add Card 21 User 21 0000200036 Enter 10 digit card number 0000200036 Enter 10 digit card number 6 Exit programming 5 Copyright 2016 Access Control Technology Ltd. Part No.18-00094 Issue 1.1 ACT 5e prox 2R.indd 6 19/02/2016 17:05:08

Change Programming Code: Enter Programming Mode (69999), then press: Step Keypad Entry Operation 1 0 Change Programming code (Default 9999) 2 Press 4 3 0000-9999 New 4 digit programming code Set Door Relay Times: Enter Programming Mode (69999), then press: Step Keypad Entry Operation 1 2 Set Door Relay Time (default 5 seconds, maximum 255 seconds) 2 0 or 1 0 = Relay 1 1 = Relay 2 Buzzer sounds indicating timing wait required period 3 Press 4 End setting Door Relay Timer Set Relay Combinations: Enter Programming Mode (69999), then press: Step Keypad Entry Operation Example: Set user 12 to activate relay 2 when access granted 1 1 Set Relay Combinations 1 Set Relay Combinations 2 00-49 Enter 2 digit User Number 00-49 12 User 12 3 0-3 0 = Relay 1 Toggle 1 = Relay 1 Timed 2 = Relay 2 Timed 3 = Relay 1 and 2 Timed 2 Relay 2 Timed Deleting User s Card: Enter Programming Mode (69999), then press: Step Keypad Entry Operation Example: Delete User 10 s card 1 6 Delete User s Card 6 Delete cards 2 00-49 First user to delete 10 User 10 3 00-49 Last user to delete 10 User 10 Deleting Card Number: Enter Programming Mode (69999), then press: Step Keypad Entry Operation 1 7 Delete card number 2 10 digit card number 10-digit Card number with leading zeroes. E.g. Card 54321, enter 0000054321 Copyright 2016 Access Control Technology Ltd. Part No.18-00094 Issue 1.1 6 ACT 5e prox 2R.indd 7 19/02/2016 17:05:08

Check if User has no PIN Assigned: Enter Programming Mode (69999), then press: Step Keypad Entry Operation 1 80 Check if user has no PIN already assigned 2 00-49 User 0-49 Keypad will flash the green led and sound high-pitched tone if the user has NO PIN code assigned. It will flash red and sound low-pitched tone, if the user has a PIN code. Check if User has no Card Assigned: Enter Programming Mode (69999), then press: Step Keypad Entry Operation 1 81 Check for user with no card assigned 2 00-49 User 0-49 Keypad will flash the green led and sound high-pitched tone if the user has NO card assigned. It will flash red and sound low-pitched tone, if the user has a card. Programming ACT 5e prox Options: Enter Programming Mode (69999), then press: Step Keypad Entry Operation 1 30, 31,32,40 or 41 2 digit option number 2 0 or 1 0=Off, 1=On Option Function Default Operation 30 Card or PIN On When set, a valid Card or valid PIN will open the door. 31 Card and PIN Off When set, only users with both a Card and PIN are admitted. Cards are assigned to a particular user using the Adding Cards function (function 5) and PINs are assigned using the Changing PIN Codes function (function 0). 32 Card and any PIN Off In this mode, a valid card and any valid PIN code will open the door. This mode allows all users to have a common PIN code to use with their cards. 40 Permanent Backlight On When set, the keypad illumination is always on. This option will override option 41 (Auto Backlighting). 41 Auto Backlighting Off When set, the keypad illumination is normally off, but will switch on in response to any key being pressed, or when a card is presented or while in programming mode. This option is overridden by option 40 (Permanent Backlight). To prevent any illumination, turn off options 40 and 41. 7 Copyright 2016 Access Control Technology Ltd. Part No.18-00094 Issue 1.1 ACT 5e prox 2R.indd 8 19/02/2016 17:05:08

Restoring Factory Defaults Enter Programming Code followed by 444. This restores the ACT 5e prox to its default settings. If the Programming Code has been forgotten, it may be set to 9999 by: 1. Remove the power from the unit. 2. Remove link LK1 at the back of the unit. 3. Apply power to unit. 4. Replace link LK1. 5. Programming Code is now set to 9999. Note: The keypad will not operate correctly without LK1 in place. Defaulting memory takes 3-4 seconds. During this time, the buzzer will sound an elongated tone. Copyright 2016 Access Control Technology Ltd. Part No.18-00094 Issue 1.1 8 ACT 5e prox 2R.indd 9 19/02/2016 17:05:08

Figure 1: ACT 5e prox 2R Wiring Diagram for Strike Lock Note: The ACT 5e prox may be powered up from 12V or 24V AC or DC LK 1 Power up without link if programming code has been lost 12V 0V Normally Open PUSH TO EXIT PB N/C C N/O PUSH TO EXIT Normally Open RELAY 1 RELAY 2 12V IMPORTANT: Place varistor across all lock terminals 12V Strike Lock 1 0V 0V Strike Lock 2 9 Copyright 2016 Access Control Technology Ltd. Part No.18-00094 Issue 1.1 ACT 5e prox 2R.indd 10 19/02/2016 17:05:18

Figure 2: ACT 5e prox Wiring Diagram for Magnetic Lock Note: The ACT 5e prox may be powered up from 12V or 24V AC or DC LK 1 Power up without link if programming code has been lost 12V 0V PUSH TO EXIT PB N/C PUSH TO EXIT C N/O RELAY 1 RELAY 2 Magnetic Lock 1 12V IMPORTANT: Place varistor across all lock terminals 12V Magnetic Lock 2 0V 0V Copyright 2016 Access Control Technology Ltd. Part No.18-00094 Issue 1.1 10 ACT 5e prox 2R.indd 11 19/02/2016 17:05:28

Figure 3 Mounting instructions for surface mount unit Surface Mount Unit The surface mount collar is mounted on the wall using the fixing kit supplied in the box. Security screw supplied with the unit Place the cap onto the unit and push firmly in place Place the reader / keypad onto the surface mount collar and clip down into place. Use the security screw supplied to attach the unit to the surface mount collar. 11 Copyright 2016 Access Control Technology Ltd. Part No.18-00094 Issue 1.1 ACT 5e prox 2R.indd 12 19/02/2016 17:05:29

Figure 4 Mounting instructions for flush mount unit Flush Mount Unit Standard pattress box Mounting plate is attached to the pattress using the screws supplied. Ensure the correct spacers have been used to bridge the gap between the mounting plate and the fixing wings of the pattress box to avoid the mounting plate being distorted. Spacers break away from main component when required by installer for use View shows mounting plate before spacers are broken away by installer Security screw supplied with the unit Screws View showing spacer stacking Place the cap onto the unit and push firmly in place Place the reader / keypad onto the surface mount collar and clip down into place. Use the security screw supplied to attach the unit to the flush mount collar. Note: Determine the distance between the pattress box and the mounting plate, using the spacers that are labelled 1mm to 4mm. A spacer of the correct length is assembled by stacking the spacers together. Copyright 2016 Access Control Technology Ltd. Part No.18-00094 Issue 1.1 12 ACT 5e prox 2R.indd 13 19/02/2016 17:05:29

User User Name Card Number Pin Relay 00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 Example: 12 John Smith 000200036 7529 1 13 ACT 5e prox 2R.indd 14 19/02/2016 17:05:30

Use the tables below to record your wiring and make your next visit easier. Location Date of Installation Device Power Relay 1 Relay 2 Push Button 1 Push Button 2 Break Glass 1 Break Glass 2 Wire Colour 14 ACT 5e prox 2R.indd 15 19/02/2016 17:05:30

Access Control Technology Ltd. reserve the right to change the contents of this manual and the system it applies to without prior notice. While every effort has been taken by ACT to ensure the accuracy of the information contained within this document, ACT assumes no responsibility for any errors or omissions. No liability is assumed for damages resulting from the use of information contained within this document. Ireland Office Unit C1, South City Business Centre, Tallaght, Dublin 24, Ireland United Kingdom Office Birchwood 1, Dewhurst Road, Birchwood Warrington, WA3 7GB, UK Ireland: +353 (0)1 466 2570 UK: +44 (0)161 236 9488 Email: info@act.eu www.act.eu Established 1995 ACTing for the installer for over 20 years Copyright 2016 Access Control Technology Ltd. Part No. 18-00094 Issue 1.1 ACT 5e prox 2R.indd 16 19/02/2016 17:05:30