ATS22C17Q. Main. Range of product Altistart 22. Component name. Factory setting current. Utilisation category. IP degree of protection

Similar documents
ATS22D47S6U. Main. Range of product Altistart 22. Component name. Factory setting current. Utilisation category. IP degree of protection

ATS22D75S6U. Main. Range of product Altistart 22. Component name. Factory setting current. Utilisation category. IP degree of protection

ATS22C41Q soft starter-ats22-control 220V-power 230V(110kW)/ V(220kW)

ATS22D17Q soft starter-ats22-control 220V-power 230V (4kW)/ V(7.5kW)

ATS22C11S6U soft starter-ats22-control110vpower208v(30hp)/230v(40hp)/460v(75hp)/575v(100hp)

ATS22C11S6U soft starter-ats22-control110vpower208v(30hp)/230v(40hp)/460v(75hp)/575v(100h

ATS22D75Q soft starter-ats22-control 220V-power 230V(18.5kW)/ V(37kW)

ATS22D62Q soft starter-ats22-control 220V-power 230V(15kW)/ V(30kW)

ATS22C21S6U softstarter-ats22-control110vpower208v(60hp)/230v(75hp)/460v(150hp)/575v(200hp)

ATS22D75S6 soft starter-ats22-control 220V-power 230V(18.5kW)/ V(37kW)/500V(45kW)

ATS22D17Q soft starter-ats22-control 220V-power 230V(4kW)/ V(7.5kW)

ATS22D88S6U. ATS22D88S6U soft starter-ats22-control110v-power 208V(25hp)/230V(30hp)/460V(60hp)/575V(75hp) Product data sheet Characteristics.

ATS01N103FT soft starter for asynchronous motor - ATS01-3 A V KW

ATS01N232RT soft starter for asynchronous motor - ATS01-32 A V

ATSU01N209LT soft starter for asynchronous motor - ATSU01-9 A V KW

ATS22C14Q meki upuštač ATS22 upravljanje 220V-snaga 230V (37kW)/ V(75kW)

ATS01N206RT soft starter for asynchronous motor - ATS01-6 A V

ATV12H075M3 variable speed drive ATV kW - 1hp V - 3ph - with heat sink

ATV12H018M2 variable speed drive ATV kW hp V - 1ph

ATV12P037F1 variable speed drive ATV kW hp V - 1ph - on base plate

TM7BDI16B. Main. Enclosure material. Input/output number 16 Input/output number of splitter box

ATV12HU22M3 variable speed drive ATV12-2.2kW - 3hp V - 3ph - with heat sink

ATV12P075M3 variable speed drive ATV kW - 1hp V - 3ph - on base plate

ZBRN1. Main. Device short name

ATV310HU30N4E variable speed drive ATV310-3 kw - 4 hp V - 3 phase

TM241C24R. Main. Discrete output type. Discrete output number. 14 (remote I/O architecture) 50 µs turn-on operation with I0...I13 terminal(s) input

LXM32AD18N4 motion servo drive - Lexium 32 - three-phase supply voltage 208/480V kw

TM7BDM8B. Main. Enclosure material. Input/output number 8 Input/output number of splitter box

SR2A201BD. Main. <= 0.5 ma for IB...IG used as discrete input circuit. <= 5 Vfor IB...IG used as discrete input circuit V

RM35LM33MW liquid level control relay RM35-L V AC/DC

LXM32SD18M2 motion servo drive - Lexium 32-single phase supply voltage 115/230V - 0.5/1.kW

RM17TG. Main. Product or component type. Product specific application. Relay monitored parameters. Switching capacity in VA 250 V AC

RE7YA12BU time delay relay for star-delta starter s - 24 V AC DC - 2OC

ATV32HD11N4 variable speed drive ATV32-11 kw V - 3 phase - with heat sink

RE7YA12BU. Main. Contacts type and composition Component name Time delay type. 24 V AC/DC at 50/60 Hz V AC/DCat 50/60 Hz

RM17UB3. Price* : USD

ATV320U06N4C variable speed drive ATV kW V - 3 phase - compact

RM17TG. Main. Product or component type. Product specific application. Relay monitored parameters. Switching capacity in VA

RM22LA32MR Level control relay RM22-L V AC/DC - 2 C/O

ATV320U04N4C variable speed drive ATV kW V - 3 phase - compact

ABR1S102B. Main. Contacts type and composition [Uc] control circuit voltage Control circuit type

ATV32HD11N4 variable speed drive ATV32-11 kw V - 3 phase - with heat sink

ATV32HU75N4 variable speed drive ATV kw V - 3 phase - with heat sink

ATV32HU30N4 variable speed drive ATV32-3 kw V - 3 phase

RE7RB13MW adjustable off-delay timing relay s V AC DC - 2OC

RM35TF. Main. Product or component type. Product specific application. Relay monitored parameters 250 V AC 5 A AC

ABL8RPS24100 regulated SMPS - 1 or 2-phase V - 24 V - 10 A

ATV930U07M3 variable speed drive - ATV930-0,75kW - 200/240V- with braking unit - IP21

ATV61HC31Y variable speed drive ATV61-310kW - 690V - without EMC filter

ABL1REM Main. Rated power in W. Power supply output current V. <= 100 Aat 230 V AC. 2.5 Aat 240 V

ATV320U07M2C variable speed drive ATV kW V - 1 phase - compact

ATV32H055N4 variable speed drive ATV kw V - 3 phase - with heat sink

ATV32HU30N4 variable speed drive ATV32-3 kw V - 3 phase - with heat sink

RM4TR31 three-phase network control relay RM4-T - range V

TM7BDM16A expansion block - TM7 - IP67-16 DI/DO - 24V DC A - M12 connector

RE7RM11BU off-delay timing relay with control contact s - 24 V AC DC - 1OC

TM238LFDC24DT. Main. Discrete output voltage. Discrete input voltage type. Number of I/O expansion module 7 [Us] rated supply voltage

RE22R1QMQ star-delta timing relay - 230VAC/440VAC - 1 C/ O

ABL8RPS24100 regulated SMPS - 1 or 2-phase V - 24 V - 10 A

ATV212WD30N4 variable speed drive ATV212-30kW - 40hp - 480V - 3ph - EMC class C2 - IP55

RE8TA31BU industrial timing relay s - type A - 24 V AC/DC, V AC - 1 C/O

ATV320D11N4B variable speed drive ATV320-11kW V - 3 phase - book

ATV320D15N4B variable speed drive ATV320-15kW V - 3 phase - book

ATV320D15N4B variable speed drive ATV320-15kW V - 3 phase - book

ATV930U30M3 variable speed drive - ATV930-3kW - 200/240Vwith braking unit - IP21

ATV212WU55N4 variable speed drive ATV kW - 7.5hp - 480V - 3ph - EMC class C2 - IP55

ATV32H075M2 variable speed drive ATV32-0,75 kw V - 1 phase - with heat sink

TM3DI16G module TM3-16 inputs spring

RM4LA32M liquid level control relay RM4-L V AC

ATV212WU40N4 variable speed drive ATV212-4kW - 5hp - 480V - 3ph - EMC class C2 - IP55

ATV310H075N4E variable speed drive ATV kw - 1 hp V - 3 phase

ATV320U30N4B variable speed drive ATV320-3kW V - 3 phase - book

SD328AU68S2 motion control stepper motor drive - SD328 - <= 6.8 A

ATV630U15N4 variable speed drive ATV kW/2HP V - IP21/UL type 1

ABL1RPM24100 regulated SMPS - single phase V input - 24 V output W

RE8YG31BUTQ industrial timing relay s - type Qc - 24 V AC/DC, V AC - 1C/O

RM35LM33MW liquid level control relay RM35-L V AC/DC

HMISCU6A5. Main. 60 right 40 top 60 bottom

TM5C12D6T6L compact I/O expansion block TM5-24 I/0-12 DI - 6 DO transistor - 4 AI - 2 AO

ATV212HD18N4 variable speed drive ATV kW - 25hp - 480V - 3ph - EMC - IP21

RE9RA21MW7 off-delay timing relay s V AC -

ATV212HU75N4 variable speed drive ATV kW - 10hp - 480V - 3ph - EMC - IP21

RM4TA32 three-phase network control relay RM4-T - range V

RM35UB3. Product data sheet Characteristics. voltage control relay RM35-U - range V AC. Main. Complementary

ABL1REM24100 regulated SMPS - single phase V input - 24 V output W

RM4JA31M current measurement relay RM4-J - range ma V AC

ATV32HU40N4 variable speed drive ATV32-4 kw V - 3 phase - with heat sink

RM17UB3. Product data sheet Characteristics. voltage control relay RM17-U - range V AC. Main. Complementary

LMC058LF42 compact base - 42 I/O - 24 V DC supply

ATV212HD15N4 variable speed drive ATV212-15kW - 20hp - 480V - 3ph - EMC - IP21

ATV212HD11N4 variable speed drive ATV212-11kW - 15hp - 480V - 3ph - EMC - IP21

ATV32HU11M2437 variable speed drive ATV32-1.1kW 200V - 1P - Bluetooth built-in - w heat sink

ATV61HC11N4 SPEED DRIVE 150 HP 460 V ATV61

ATV212HD75N4. Main. Range of product Altivar 212. Device short name. Motor power hp 160 A 460 V khz with derating factor

RM17UAS. Product datasheet Characteristics. voltage control relay RM17-U - range V DC. Main. Complementary. Price* : 70.

RM35TF V AC

ABL8BBU24200 battery control module V DC - 24 V - 20 A - for regulated SMPS

ATV212HD11M3X variable speed drive ATV212-11kW - 15hp - 240V - 3ph -wo EMC - IP21

ABE7H16R11 passive connection sub-base ABE7-16 inputs or outputs - Led

ATV32H018M2 variable speed drive ATV32-0,18 kw V - 1 phase - with heat sink

Transcription:

Product datasheet Characteristics ATS22C17Q Complementary Assembly style Function available Supply voltage limits Main Range of product Altistart 22 Product or component type Product destination Product specific application Component name Phase Soft starter Asynchronous motors Pumps and fans ATS22 3 phases [Us] rated supply voltage 230...440 V - 15...10 % Motor power kw Factory setting current Power dissipation in W Utilisation category Type of start IcL starter rating IP degree of protection With heat sink Internal bypass 195...484 V Supply frequency 50...60 Hz - 10...10 % Network frequency Device connection [Uc] control circuit voltage Control circuit consumption Discrete output number 2 Discrete output type Minimum switching current Maximum switching current Discrete input number 3 Discrete input type Discrete input voltage Discrete input logic Output current PTC probe input Communication port protocol Connector type Communication data link Physical interface Transmission rate Installed device 31 Protection type 45...66 Hz In the motor supply line To the motor delta terminals 230 V -15...10 % 50/60 Hz 20 W 45 kw 230 V 90 kw 400 V 90 kw 440 V 162 A 91 W for standard applications AC-53A Start with torque control (current limited to 3.5 In) 170 A connection in the motor supply line for standard applications IP00 Relay outputs R1 230 V running, alarm, trip, stopped, not stopped, starting, ready C/O Relay outputs R2 230 V running, alarm, trip, stopped, not stopped, starting, ready C/O 100 ma 12 V DC relay outputs 5 A 250 V AC resistive 1 relay outputs 5 A 30 V DC resistive 1 relay outputs 2 A 250 V AC inductive 0.4 20 ms relay outputs 2 A 30 V DC inductive 7 ms relay outputs Logic LI1, LI2, LI3 5 ma 4.3 kohm 24 V <= 30 V Positive logic LI1, LI2, LI3 < 5 V and <= 2 ma > 11 V >= 5 ma 0.4...1 Icl adjustable 750 Ohm Modbus 1 RJ45 Serial RS485 multidrop 4800, 9600 or 19200 bps Thermal protection motor 1 / 8 The information provided in this documentation contains general descriptions and/or technical characteristics of the performance of the products contained herein. This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications. It is the duty of any such user or integrator to perform the appropriate and complete risk analysis, evaluation and testing of the products with respect to the relevant specific application or use thereof. Neither Schneider Electric Industries SAS nor any of its affiliates or subsidiaries shall be responsible or liable for misuse of the information contained herein.

Marking Type of cooling Operating position Height Width Depth Product weight Power range Motor starter type Phase failure line Thermal protection starter CE Forced convection Vertical +/- 10 degree 14.02 in (356 mm) 5.91 in (150 mm) 9.04 in (229.5 mm) 39.68 lb(us) (18 kg) 30...50 kw at 200...240 V 3 phases 55...100 kw at 380...440 V 3 phases Soft starter Environment electromagnetic compatibility Conducted and radiated emissions level A IEC 60947-4-2 Damped oscillating waves level 3 IEC 61000-4-12 Electrostatic discharge level 3 IEC 61000-4-2 Immunity to electrical transients level 4 IEC 61000-4-4 Immunity to radiated radio-electrical interference level 3 IEC 61000-4-3 Voltage/current impulse level 3 IEC 61000-4-5 standards EN/IEC 60947-4-2 product certifications CCC CSA C-Tick GOST UL vibration resistance 1 gn 13...200 Hz EN/IEC 60068-2-6 1.5 mm 2...13 Hz EN/IEC 60068-2-6 shock resistance 15 gn 11 ms EN/IEC 60068-2-27 noise level 56 db pollution degree Level 2 IEC 60664-1 relative humidity 0...95 % without condensation or dripping water EN/IEC 60068-2-3 ambient air temperature for operation ambient air temperature for storage operating altitude 14...104 F (-10...40 C) without derating > 104...< 140 F (> 40...< 60 C) with current derating 2.2 % per C -13...158 F (-25...70 C) <= 3280.84 ft (1000 m) without derating > 3280.84...< 6561.68 ft (> 1000...< 2000 m) with current derating of 2.2 % per additional 100 m Offer Sustainability Green Premium product Compliant - since 0938 - Schneider Electric declaration of conformity Reference not containing SVHC above the threshold Available Available WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. Bisphenol A (BPA), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.p65warnings.ca.gov Green Premium product Compliant - since 0938 - Schneider Electric declaration of conformity Reference not containing SVHC above the threshold Available Available WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. Bisphenol A (BPA), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.p65warnings.ca.gov Contractual warranty Warranty period 18 months Frame Size C 2 / 8

Dimensions Precautions Standards The Altistart 22 soft starter is compliant with pollution Degree 2 as defined in NEMA ICS1-1 or IEC 60664-1. For environment pollution degree 3, install the Altistart 22 soft starter inside a cabinet type 12 or IP54. Air Circulation DANGER HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH ATS22 soft starters are open devices and must be mounted in a suitable enclosure. Failure to follow these instructions will result in death or serious injury. Leave sufficient free space to help the air required for cooling purposes to circulate from the bottom to the top of the unit. Overheating To avoid the soft starter to overheat, respect the following recommendations: Mount the Altistart 22 Soft Starter within ± 10 of vertical. Do not locate the Altistart 22 Soft Starter near heat radiating elements. Electrical current through the Altistart 22 Soft Starter will result in heat losses that must be dissipated into the ambient air 3 / 8

immediately surrounding the soft starter. To help prevent a thermal fault, provide sufficient enclosure cooling and/or ventilation to limit the ambient temperature around the soft starter. If several soft starters are installed in a control panel, arrange them in a row. Do not stack soft starters. Heat generated from the bottom soft starter can adversely affect the ambient temperature around the top soft starter. Mounting Connection Between the Fan and the Altistart 22 Soft Starter 1 Altistart 22 Soft Starter 2 Fan Wall mounted or Floor-standing Enclosure with IP 23 Degree of protection Introduction To help proper air circulation in the soft starter, grilles and forced ventilation can be installed. Ventilation Grilles Forced Ventilation Unit Power Terminal Bar Style 4 / 8

Power supply and output to motor Bar b 20 mm (0.79 in) a Bolt Cable and protective cover Size Gauge Protective cover Tightening torque 5 mm (0.2 in) M8 (0.31 in) 95 mm² 250 MCM LA9F702 18 N.m 157.5 lb.in Power connections, minimum required wiring section IEC cable mm² (Cu 70 C/158 F) (1) UL cable AWG (Cu 75 C/167 F) (1) 70 4/0 230 Vac control, logic Inputs (LI) 24 Vdc, 3-wire control With Line Contactor, Freewheel or Controlled Stop 230 Vac control, logic Inputs (LI) 24 Vdc, 2-wire control,freewheel stop 5 / 8

Connection in the motor delta winding in series with each winding Wiring ATS22 soft starters connected to motors with the delta connections can be inserted in series in the motor windings. The following wiring requieres particular attention. It is documented in the Altistart 22 Soft start - soft stop unit user manual. Please contact Schneider Electric commercial organisation for further informations. Example A 400 V - 110 kw motor with a line current of 195 A (nominal current for the delta connection). The current in each winding is equal to 195/1.5 or 130 A. The rating is determined by selecting the soft starter with a permanent nominal current (ICL) just above this current. Motor Thermal Protection - Cold Curves Curves 6 / 8

A Class 10 B Class 20 C Class 30 Trip time for a Standard Application (Class 10) 32 s Trip time for a Severe Application (Class 20) 63 s Trip time for a Severe Application (Class 30) 95 s Motor Thermal Protection - Warm Curves Curves 7 / 8

A Class 10 B Class 20 C Class 30 Trip time for a Standard Application (Class 10) 16 s Trip time for a Severe Application (Class 20) 32 s Trip time for a Severe Application (Class 30) 48 s 8 / 8