Accessories and options

Similar documents
Public Address and Controlled Evacuation

TXM1.8RB. TX-I/O Blinds module

M-bus web server. Meters and Energy Cost Allocation WTV676-HB6035

Digital input modules

Power supply module, bus connection module

MINI-PS AC/10-15DC/8

TXM1.8U TXM1.8U-ML. Universal modules TX-I/O

RMZ782B RMZ783B. Extension Modules. Building Technologies HVAC Products. Synco 700. for heating controller RMH760B

12-15VDC (12V±5%) 24-28VDC (24V±5%)

Super universal modules

Universal Modules. Synco 700. Extension modules for use with controls of the Synco 700 family. Use

BACnet/IP Web Interface

Chrome DIN Rail Power Supply 12V 9.96W 1 Phase (Class II & NEC Class 2) / DRC-12V10W1A

Faults on the system Proximity switch connection technology:

RXM39.1. PL-Link IO Block. Desigo TRA. Use with PXC3 series room automation station

12-15VDC (12V±5%) 24-28VDC (24V±5%)

Chrome DIN Rail Power Supply 5V 7.5W 1 Phase (Class II & NEC Class 2) / DRC-5V10W1AZ

TXM1.8T. Triac module Used for Thermic and motor-driven actuators (AC 24 V) TX-I/O

Rotary version, three-position control

USB-KNX Interface OCI702. USB-KNX interface with cables and service bag

FL MC 2000E (SM40) LC

Safety Standards. Model Number: Unit Weight:

Resistance measuring module

TXM1.8U TXM1.8U-ML. Universal modules TX-I/O

Industrial Power Supplies

Chrome DIN Rail Power Supply 24V 10W 1 Phase (Class II & NEC Class 2) / DRC-24V10W1A

MPU-120S Series. Single Output, 180W Compact, U-Channel AC/DC Power Supplies. Key Features:

EZ864 UMTS Terminal Telit Cellular GSM Engine

TM221CE40R controller M IO relay Ethernet

PHOENIX CONTACT - 07/2006

TXM1.8U TXM1.8U-ML. Universal modules TX-I/O

Room unit with PPS2 interface

PHOENIX CONTACT - 01/2010. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

GT- IRDM-9603 Product description Rev. 2 17/06/2014

040APS12 B MDS. MDS Medical AC-DC Open Frame 12Volt, 40Watt / MDS-040APS12 B ``` Highlights & Features. Safety Standards.

Safety Standards. Model Number:

FL MC 2000T. Fiber optic converter for 10/100Base-Tx to single- or multi-mode fiberglass with SC-duplex and ST connections. Data sheet 3379_en_B

Interface converter for VAV compact controllers

Ripple & Noise (max) (See Note 2) 5V output: 100mVp-p; 12V - 27V outputs: 150mVp-p; 48V output: 200mVp-p

Output Voltage* (nom.)(adjustable)

OTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP m

TM200CE24T controller M IO transistor Source+ Ethernet

MPV1560RI4. Ultra Wide Input, Compact Industrial Grade, PV Power DC/DC Con vert ers. Key Features:

E-STOP relays, safety gate monitors

XPSMF35. Product data sheet Characteristics. Preventa safety PLC compact - Profibus DP protocol. Main. Complementary. Safety module name

Safety Standards. Model Number:

Chrome DIN Rail Power Supply 24V 10W 1 Phase (Class II & NEC Class 2) / DRC-24V10W1AZ

CliQ II DC-UPS Module 24V 40A / DRU-24V40ABN

MPV1060RI4. Ultra Wide Input, Compact Industrial Grade, PV Power DC/DC Con vert ers. Key Features:

Features. Regulated Converter. RAC35-G/OF 35 Watt 4 x 2 Open Frame RAC35- SG/OF. AC/DC Converter

Network node WTT56.. A6V _en--_c Building Technologies

PHOENIX CONTACT - 08/2009. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

E-STOP relays, safety gate monitors

FEATURES. Nominal Output Voltage and Current

MPO-120S Series. Single Output, 180W Compact, Open Frame AC/DC Power Supplies. Key Features:

TM221M16TG controller M IO transistor PNP spring

CMU 100 RS485 to 7x, 6x, 5x, 4x Multimode Fiber Optic Star Coupler User Manual

GT- HE910-EUD. Product description Rev. 8 21/02/ Overview

RXB39.1. Room controller RXB. Communicating room controller for fan-coil applications FC-13

TM221ME16T controller M IO transistor PNP Ethernet

SAX.. ACVATIX Electromotive actuators for valves. with a 20 mm stroke

Switch Mode Power Supply S8VT 120/240/480/960 W Models

Industrial Power Supplies

Safety Standards. Model Number:

Air damper actuators

Safety Standards. Model Number:

Island bus expansion module

060AAS19 B MDS. MDS Medical AC-DC Adapter 19Volt, 60Watt / MDS-060AAS19 B. Highlights & Features. Safety Standards. Model Number: General Description

E-STOP relays, safety gate monitors

Positive-guided relay outputs: 4 safety contacts (N/O), instantaneous

HMISBC Rear Module controller panel - Dig 8 inputs/8 outputs +Ana 4 In/2 Out

RXL24.1. Room controller RXL. Communicating controller for chilled ceiling and radiator applications CC-02

Safety Standards. Model Number:

EZ864 G. Telit Cellular GSM/UMTS Engine. Hardware guide Version: Update: 27. APR.2009 EZ864 G_Hardware Guide_V

TM221CE24T controller M IO transistor PNP Ethernet

Safety Standards. Model Number:

Mobile Data Collector

Rotary actuators for ball valves

QUINT-BUFFER/24DC/24DC/40

AC-DC POWER SUPPLIES UNIVERSAL INPUT, 65 WATT MEDICAL APPLICATIONS MUI65 SERIES

QXA2000 QXA2001. Condensation Monitor QXA2001 QXA2000 AQX2000

TM221M32TK controller M IO transistor PNP

Voice Alarm System VX-3000 Series

OTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP m

TM221CE40R controller M IO relay Ethernet

EZmoto V4.1 Product description Rev. 2 30/07/2015

Switched-Mode Power Supplies. 5, 12, 18, 48 VDC Output

MI1000ERW. Series. Miniature 1 x 1, 2:1 Input, 10W DC/DC Con vert ers. Key Features:

XPSMCMCO0000EM Modbus TCPIP diagnostic expansion module with screw term

Safety Standards. Model Number:

STEP-PS/1AC/24DC/1.75

TM221CE40T controller M IO transistor PNP Ethernet

RTU500 series Data Sheet Power Supply CP-E 24/2.5

OTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP m

Application Package Dimension Output Input Output Output Protection Option Code Code Power Voltage Quantity Voltage Type (W) (VAC) (VDC)

TECHNICAL DATASHEET MDS Medical AC-DC Open Frame 065APS24 B Highlights & Features Safety Standards Model Number: Unit Weight Dimensions (W x L x H):

CompactBlock Guard I/O EtherNet/IP Safety Modules

TM221M16R controller M IO relay

TM3TM3 module TM3-2 temperature inputs and 1 analog output

POE084824B. PoE 54V/8x0,3A/4x7Ah PoE buffer power supply for up to 8 IP camera. v.1.1 EN* Edition: 7 from

Transcription:

Novigo Accessories and options PCA2001-A1, PCA2002-A1, PCA2004-A1, PCA2005-A1, PCA2007-A1, PCA2008-A1, PCA2011-A1, PCA2012-A1, PCA2013-A1, PCIO2001-A1, PCO2001-A1, PNA2007-A1 Accessories and optional components for the EN 54-16-certified Novigo digital multichannel audio system. Accessories and optional components specifically tailored to the requirements of the Novigo multi-channel audio system Media for storing and expanding the audio library of a Novigo system I/O interfaces for expanding the inputs and outputs of digital audio matrices Components for automatic volume control Components for monitoring remote system components for open lines, ground faults, and short-circuits DC/DC converter for protecting remote system components from short-circuit on the external power supply Insulation components for isolating and maintaining the function of speakers in the event of a short-circuit on a speaker line Network repeater for extending network lines in the 'PACE-Net' 2018-10-22 Control Products and Systems

Features and Functions Call stations / operating terminals Ground fault monit. (24 V) PCA2001-A1 Monitoring of the DC 24 V line for ground faults Used with remote system components (Required when the 24 V line exits the system cabinet to supply energy to components such as the fire brigade microphone) General message relating to fault to relay changeover contact (Fault / Okay) Fault indicated via LED on module Switch to a lower sensitivity of 10 kohm via jumper setting Installation in a system cabinet (TS35 DIN-rail-ready) All connections on plug-in terminal blocks MeanWell SD-50C-24 DC/DC PCA2011-A1 Controlled DC 24 V output voltage, electrically isolated Internal 24 V energy supply protected against short-circuits on the external 24 V supply line outside the system cabinet Protected against short-circuit, overloading and overvoltage DC 1500 V I/O isolation 100 % full load burn-in test Fixed switch frequency of 83 KHz I/O interfaces IN/OUT extension digital (16) PCIO2001-A1 For use with the digital audio matrices PC2001-A1, PC2002-A1, and PC2003-A1. Communication via RS485 or RS232 interfaces Extends the digital audio matrices PC2001-A1, PC2002-A1, and PC2003-A1 by an additional 16 digital outputs Outputs are electrically isolated Extends the digital audio matrices PC2001-A1, PC2002-A1, and PC2003-A1 by an additional 16 digital inputs Extends a device by an additional 8 analog inputs OUT extension relay (8) PCO2001-A1 Digital output extension for the audio matrices PC2001-A1, PC2002-A1, and PC2003-A1 The assembly includes eight relays with changeover contact The maximum permissible switching current for each changeover contact is 7 A for AC or DC 24 V Communication via RS232 interface 2

Automatic volume control Automatic volume control module PCA2008-A1 Supports automatic volume control to suit levels of background noise Connection of up to four microphones PCA2007-A1 Supports microphone and line level Supplies the connected microphones with DC 12 V phantom voltage Installation in the system cabinet (TS35 DIN-rail-ready) All connections on plug-in terminal blocks Fault message via relay changeover contact (Fault / Okay) Automatic volume control microphone PCA2007-A1 Supports automatic volume control to suit levels of background noise Power supply via phantom voltage through automatic volume control module PCA2008-A1 (no separate power supply required) Electret microphone in an IP54 protective housing For use with the digital audio matrices PC2001-A1, PC2002-A1, and PC2003-A1. Symmetrical output: Controllable microphone / line level Microphone or line level (high resistance to faults) Simple mounting and installation Connection to 3-pin terminal Linear frequency band of 100 Hz to 10 khz 3

Extras ATP AF2GUD-2*** SD 2 GB PCA2002-A1 2 GB Micro SD memory card for Novigo Up to 256 audio files with a total duration of 3 h For industrial applications Water-tight Dust-tight Guaranteed data storage: >10 years EOL modules EOL3 (active) PCA2004-A1 For monitoring the speaker line for open lines and short-circuits Monitoring in accordance with EN 54-16 Addressable: up to 16 different addresses can be configured Addressing compatible with any structure with up to 16 line ends, in addition to the stub line Reliable cable break detection in any branch of a speaker line Suitable for 100 V, 70 V, 50 V and 25 V speaker systems No other wiring needed; works with standard two-wire speaker line No need to route line back to control panel 4

Loop isolators Loop isolator (100 V) PCA2005-A1 Isolating element for use in a 100 V speaker line Rapidly detects and isolates short-circuits affecting the 100 V speaker line Monitors the speaker connected to the loop isolator for open lines and short-circuits Suitable for 100 V, 70 V, 50 V and 25 V speaker systems Two-pole standard lines used as cables for the speaker loop Optical display of isolator status (internal or external LED) Spelsberg i 16-L Li Box PCA2013-A1 Housing for loop isolator (100 V) PCA2005-A1 IP55 Loop isolator LED PCA2012-A1 External LED Status indicator for loop isolator (100 V) PCA2005-A1 5

'PACE-Net' Repeater (CAT5) PNA2007-A1 Extension of 100 Mbit/sec Ethernet line by 100 m Use Call stations / operating terminals I/O interfaces Ground fault monit. (24 V) PCA2001-A1 The ground fault monit. (24 V) PCA2001-A1 is a module for monitoring 24 V lines outside of the system cabinets for supplying remote system components (e.g., call stations). It measures the resistance of both cores in the lines to the protective conductor (PE). According to the corresponding standard, a ground fault is detected when a resistance of <50 kohm is measured to the protective conductor. A fault message is transmitted by the relay changeover contact and indicated on the printed circuit board via LED. MeanWell SD-50C-24 DC/DC PCA2011-A1 The DC/DC converter PCA2011-A1 is required to electrically isolate DC 24 V lines exiting the system cabinet from the internal DC 24 V power supply. Any short-circuit that occurs outside the system cabinet will therefore not affect the internal 24 V supply. The device is protected against short-circuits, overload and overvoltage. IN/OUT extension digital (16) PCIO2001-A1 The IN/OUT extension digital (16) PCIO2001-A1 extends the number of digital inputs and outputs for each audio matrix by 16 additional inputs and outputs. It was specifically developed for use with the digital audio matrices PC2001-A1, PC2002-A1, and PC2003-A1. The PCIO2001-A1 and the audio matrix are connected via the RS232-based 'PACE-Bus'. OUT extension relay (8) PCO2001-A1 The PCO2001-A1 relay card adds a further 8 electrically isolated outputs to the existing digital outputs of each audio matrix. The 8 outputs are controlled via a relay with changeover contacts. All three changeover contacts are routed externally: NC, NO and center. The PCO2001-A1 was specifically developed for use with the digital audio matrices PC2001-A1, PC2002-A1 and PC2003-A1. The connection between the PCIO2001-A1 and the audio matrix is established via the RS232-based 'PACE-Bus'. 6

Automatic volume control Extras EOL modules Automatic volume control module PCA2008-A1 The automatic volume control module PCA2008-A1 receives the audio level of the measuring microphones PCA2007-A1. It is possible to connect up to four PCA2007-A1 to one PCA2008-A1. The PCA2008-A1 uses the received audio levels to calculate the average, which is then forwarded to the connected audio matrix for further processing. The device also allows for up to four microphone lines to be monitored for short-circuits and interruptions. The PCA2008-A1 was specifically developed for use with the digital audio matrices PC2001-A1, PC2002-A1, and PC2003-A1. Automatic volume control microphone PCA2007-A1 The AVC microphone PCA2007-A1 is a measuring microphone that was specifically developed for use with the digital audio matrices PC2001-A1, PC2002-A1, and PC2003-A1. It constantly records the levels in the surrounding area within a set frequency range and transmits the value to the receiver assembly PCA2008-A1 for further processing. The 'Automatic Volume Control' (AVC) function is required as a way of adjusting the sound level of the audio signal to suit the current situation in the event of huge fluctuations in background noise. This ensures that the wanted signal is always louder than any background noise so that it will be possible to understand what is being said. Plus, announcements will not be too loud for people in quiet buildings. The AVC function is used if background noise can be expected to fluctuate a lot, such as on train platforms and in airports and shopping malls. ATP AF2GUD-2*** SD 2 GB PCA2002-A1 The SD card PCA2002-A1 is a digital Micro-SD memory card with a capacity of 2 gigabytes. This card stores up to 3 hours' worth of audio files. The card can hold up to 256 individual audio files. The SD card satisfies the industry standard, providing a guaranteed data storage period of over 10 years. EOL3 (active) PCA2004-A1 The EOL3 (active) PCA2004-A1 ensures that the speaker lines are monitored without interruption in accordance with EN 54-16. The device is addressable. The 16 addresses are created by DIP switch. Up to 16 PCA2004-A1 can be installed per speaker line. The PCA2004-A1 was specifically developed for use with the digital audio matrices PC2001-A1, PC2002-A1, and PC2003-A1. 7

Loop isolators Loop isolator (100 V) PCA2005-A1 The loop isolator (100 V) PCA2005-A1 is an isolating element for use in a 100 V speaker line. The isolator rapidly detects and isolates short-circuits affecting the line. It monitors the speaker line connected to the loop isolator for open lines and short-circuits. The status of the PCA2005-A1 is shown on an optical display (internal or external LED). Two-pole standard lines are used as cables for the speaker loop. A speaker loop can accommodate up to 80 isolators. The maximum loop length is 800 m. The PCA2005-A1 was specifically developed for use with the PC2003-A1 digital audio matrices. Spelsberg i 16-L Li Box PCA2013-A1 IP55 housing for loop isolator (100 V) PCA2005-A1. Loop isolator LED PCA2012-A1 The external LED PCA2012-A1 indicates the status of the loop isolator (100 V) PCA. It can be installed in a remote display/control panel. 'PACE-Net' Repeater (CAT5) PNA2007-A1 The Novigo network is based on a standard Ethernet with 100 Mbit/sec and CAT5 cables. A standard Ethernet is usually limited to a length of 100 m. The PNA2007-A1 makes it possible to extend the CAT5 cable by an extra 100 m. The PNA2007-A1 requires a line voltage of DC 24 V. 8

Type Overview Device combinations Type Designation Digital audio matrix PC2001-A1 Digital audio matrix (4/4/4) PC2002-A1 Digital audio matrix (0/4/4) PC2003-A1 Digital audio matrix (4/4/16) PCA2005-A1 Loop isolator (100V) PCA2007-A1 Autom. volume control micro PCIO2001- A1 PCO2001- A1 Order numbers IN/OUT ext. digital (16) OUT extension relay (8) Compatible Not compatible Type Designation Order number Extras PCA2002-A1 ATP AF2GUD-2*** SD 2 GB S54451-B20-A1 Accessories for operating terminals / call stations PCA2001-A1 Ground fault monit. (24V) S54451-B19-A1 PCA2011-A1 MeanWell SD-50C-24 DC/DC S54451-B65-A1 I/O interfaces PCIO2001-A1 IN/OUT ext. digital (16) S54451-B28-A1 PCO2001-A1 OUT extension relay (8) S54451-B27-A1 Automatic volume control PCA2008-A1 Autom. volume control modul S54451-B26-A1 PCA2007-A1 Autom. volume control micro S54451-B25-A1 EOL modules PCA2004-A1 EOL3 (active) S54451-B22-A1 Loop isolators PCA2005-A1 Loop isolator (100V) S54451-B53-A1 PCA2012-A1 Loop isolator LED S54451-B55-A1 PCA2013-A1 Spelsberg i 16-L Li Box S54451-B54-A1 Accessories for 'PACE-Net' PNA2007-A1 Repeater (CAT5) S54451-B52-A1 9

Product documentation You will find more information on the Novigo system and its components in the following documents: Title IT security policies Novigo IT security policies* System documentation Novigo planning* 'PACE-Design' configuration* Novigo mounting / installation Novigo operation Data sheets System data sheet Document ID A6V11439692 A6V11467812 A6V11474760 A6V11467817 A6V11467803 A6V11467196 19" cabinets A6V11467209 Digital audio matrix Power amplifier Operating terminals Call stations Power supply and batteries Accessories and options Environmental declaration Novigo environmental declaration A6V11467202 A6V11467204 A6V11467198 A6V11467200 A6V11467207 A6V11467211 A6V11546319 *You can obtain these documents from the product support platform via the following link: https://psp.sbt.siemens.com/. Download center https://siemens.com/bt/download Enter the document ID in the search field. 10

Notes Safety CAUTION National safety regulations Failure to comply with national safety regulations may result in personal injury and property damage. Observe national provisions and comply with the appropriate safety regulations. Disposal The device is considered an electronic device for disposal in accordance with the European Guidelines and may not be disposed of as domestic garbage. Dispose of the device through channels provided for this purpose. Comply with all local and currently applicable laws and regulations. Guarantee The application-specific technical data is guaranteed only in combination with the Siemens products listed in the 'Device combinations' section. If third-party products are used, any guarantee provided by Siemens will be invalidated. 11

Technical data Extras SD card Supply Power supply Current consumption Cycle frequency Performance data Storage capacity Number of insertions Data storage period Service life Shock resistance Vibration Resistance Interfaces Plug-in contacts Ambient conditions PCA2002-A1 2.7 3.6 V <50 ma 50 Mhz max. 2 GB At least 10.000 insertions 10 years 10.000 sequences (read/write/delete) 1000 G Maximum 15G peak-to-peak Water-tight Dust-tight ESD protection 8 pins Operating temperature 0 +70 C Storage temperature 0 +70 C Operation in humid environments Storage in humid environments Dimensions and weights 10...90 % rel. 5...90 % rel. W x H x D mm 11 x 1 x 15 (+/- 0.1) Weight 0.4 g 12

Call stations / operating terminals Ground fault monitoring (24 V) Supply Power supply Current consumption Threshold Relay contact Fault indicator relay Ambient conditions PCA2001-A1 DC 24 V (corresponds to the voltage to be monitored) 100 ma 50 kohm (10 kohm if JP1 and JP2 closed) Max. 48 V / 500 ma Changeover contact (fault / OK) Can be switched to a lower sensitivity of 10 kohm for each jumper Operating temperature -5 +40 C Storage temperature -20 +70 C Operation in humid environments Storage in humid environments Housing type Mounting Dimensions and weights 10...90 % rel. 5...90 % rel. Open frame design DIN rail mounting (TS35) W x H x D mm 75 x 70 x 40 Weight 100 g Standards EN 54-16 13

DC/DC converter (24 V/50 W) Output Nominal output voltage Maximum output current Nominal output Residual ripple and noise Adjustable output voltage range Input Voltage range Input current Efficiency Protection Overload* Overvoltage* PCA2011-A1 DC 24 V 2.1 A 50.4 W 150 mvp-p DC 23 30 V DC 19 36 V 1.5 A / 24 V 80 % / 24 V 105...150 % nominal output 31.5...37.5 V/10 % load * Protection category: Hiccup mode, automatically recovers once error has been resolved Ambient conditions Operating temperature -10 +60 C Storage temperature -20 +85 C Operation in humid environments Storage in humid environments Temperature coefficient Vibration Dimensions and weights 20 90 % 10 95 % ±0.03 %/ C 10 500 Hz, 2G 10min. / 1 cycle, 60 min. on the X, Y or Z axis W x H x D mm 159 x 38 x 97 Weight Security Electric strength Insulation resistance MTBF Standards 480 g I/P-O/P: 1.5 kvac I/P-FG: 1.5 kvac O/P-FG: 0.5 kvac I/P-O/P, I/P-FG, O/P-FG: 100 Mohm / DC 500 V / 25 / 70 % RH At least 357,500 h / 25 C EN 55022 (CISPR22) class B EN 61000-4-2,3,4,6,8 14

I/O interfaces IN/OUT digital extension (16) Supply PCIO2001-A1 Power supply DC 24 V (18 V <36 V) Current consumption Internal power supply Maximum load Digital inputs Logic level Input voltage range Input current at 12 V / 24 V Digital outputs Number and type Max. voltage Max. current per output Isolation voltage Analog inputs Input voltage range Resolution Input current at 10 V Interfaces Serial interfaces Baud rate Module connections Ambient conditions 56 ma DC 10 V 100 ma / DC 10 V Logic off: <1.6 V Logic on: >8 V DC 0 36 V 0.5 ma at 12 V 1 ma at 24 V 16 electrically isolated open collector outputs DC 35 V 80 ma 3.75 kv DC 0...10 V 8 bit 0.2 ma RS232; RS485 9600,19200,56700,115200 baud 1 module per bus via RS485 1 module via RS232 Operating temperature -5 +40 C Storage temperature -20 +70 C Operation in humid environments Storage in humid environments Mounting Attachment Maximum conductor cross-section 10...90 % rel. 5...90 % rel. DIN rail mounting (TS35) 1.5 mm² Compatible with CAT5 cables (VDC+, GND, DATA+, DATA- signals) 15

Dimensions and weights PCIO2001-A1 W x H x D mm 125 x 95 x 35 (125 x 95 x 65 with optional analog output level) Weight 150 g Standards EN 54-16 OUT extension relay (8) Supply Power supply Current consumption Output Fine fuses Interfaces Serial interfaces Baud rate Ambient conditions PCO2001-A1 DC 12 24 V 200 ma at 24 V and 8 relays switched on AC 24 V, 7 A or DC 24V, 7 A 5x 20 mm,1 A, slow-blow, 250 V RS232 19200 baud Operating temperature -5 +40 C Storage temperature -20 +70 C Operation in humid environments Storage in humid environments Mounting Dimensions and weights W x H x D mm Weight 10...90 % rel. 5...90 % rel. DIN rail mounting (TS35) 100 x 40 x 160 (Eurocard) 250 g Standards EN 54-16 16

Automatic volume control Automatic volume control module Supply Power supply Current consumption Microphone power supply Monitoring of each microphone line Fault indicator relay Relay contact Cable connection Ambient conditions PCA2008-A1 DC 24 V 100 ma DC 12 V phantom power Electrically isolated from the power supply. Interruption, short-circuit, ground fault Changeover contact (fault / OK) Inactive lines can be excluded via jumper Max. 48 V / 500 ma Plug-in terminal blocks Operating temperature -5 +40 C Storage temperature -20 +70 C Operation in humid environments Storage in humid environments Housing type Mounting Dimensions and weights 10...90 % rel. 5...90 % rel. Open frame design DIN rail mounting (TS35) W x H x D mm 75 x 70 x 40 Weight 100 110 g Standards EN 54-16 17

Automatic volume control microphone Type Supply Power supply Current consumption Cable connection Audio properties Frequency band Outputs: Max. output level (MIC) Max. output level (LINE) Output impedance Ambient conditions PCA2007-A1 Electret microphone DC 12 V phantom power (up to 48 V possible) 2 ma at 12 V 3-pin terminal: Cable gland PG 9 (cable diameter 2.5 8 mm) Linear from 100 Hz 10 khz 12 μv/pa + 25 db Symmetrical output Operating temperature -5 +40 C Storage temperature -20 +70 C Operation in humid environments Storage in humid environments Housing material Dimensions and weights 10...90 % rel. 5...90 % rel. ABS W x H x D mm 36 x 64 x 98 Weight Protection category and color Protection category (IEC 60529) 140 g IP54 Color Light grey, comparable to RAL 7035 Standards EN 54-16 18

EOL modules EOL3 (active) Supply Power supply Power consumption Max. line output (corresponds to max. amplifier output on speaker line) Cable connection Maximum number of modules in use PCA2004-A1 AC 8 100 V Max. 150 mw Typ. 100 mw 500 W 2x 1.5 mm² Max. number of modules per amplifier 16 Max. number of modules per speaker line 16 Max. number of modules per dig. matrix monitor (4/4/4), dig. matrix monitor (0/4/4), digital audio matrix (4/4/16) Ambient conditions Operating temperature -5 +40 C Storage temperature -20 +70 C Operation in humid environments Storage in humid environments Dimensions and weights 64 10...90 % rel. 5...90 % rel. W x H x D mm 71 x 61 x 30 Weight Protection category (IEC 60529) 100 g IP41 Standards EN 54-16 19

Loop isolators Loop isolator (100V) Supply Power supply Power consumption Cable connection Technical data for each speaker tap on the loop isolator Max. speaker output Min. speaker output Maximum cable length Technical data for external LED connector Recommended LED color Diode conducting-state voltage Power supply Power supply Internal series resistance Technical data for loop Maximum number of modules per amplifier channel PCA2005-A1 AC 15 100 V 150 mw on startup 75 mw during operation 2x 1.5 mm² 100 W 0.75 W 50 m Red or green <2.2 V 3 V 5 ma 150 Ohm Maximum number of modules per loop 80 Maximum number of loops per digital audio matrix (4/4/16) Maximum mains supply per loop Maximum cable length Cable diameter Ambient conditions 80 4 450 W 1.000 m Min.: 0.75 mm² Max.: 2.5 mm² Operating temperature -5 +40 C Storage temperature -20 +70 C Operation in humid environments Storage in humid environments Dimensions and weights 10...90 % rel. 5...90 % rel. W x H x D mm 70 x 116 x 25 W x H x D mm (housing) 85 x 135 x 37 Weight Weight (with housing) 80 g 138 g Standards EN 54-16 20

Spelsberg i 16-L Li Box Rated insulation voltage PCA2013-A1 AC 400 V Conductor cross-section 2.5 mm 2 Ambient conditions Operating temperature -25 +40 C Max. operating temperature (24 hours) 35 C Max. air humidity at 25 C (short-term) 95 % rel. Max. air humidity at 40 C 50 % rel. Dimensions and weights W x H x D mm 130 x 85 x 37 Material Box Polyethylene Cover Polypropylene Protection category and color Protection category (IEC 60529) IP55 Color Gray 21

'PACE-Net' Repeater (CAT5) Supply PNA2007-A1 Power supply DC 24 V (18 32 V) Current consumption Interfaces Serial interfaces Connections Copper Fiber-optic ports Network standards Ambient conditions 80 ma when idling 10 ma per active port 130 ma at full load RS232 (for configuration only) 4 connections on RJ45 connector One TX and one RX port with SC connector Wavelength: 1310 nm Fiber type: MM Conforms to IEEE 802.3, 100Base-TX, 100Base-FX, 10Base Operating temperature -5 +40 C Storage temperature -20 +70 C Operation in humid environments Storage in humid environments Dimensions and weights 10...90 % rel. 5...90 % rel. W x H x D mm 200 x 115 x 250 Weight 900 g Standards EN 54-16 Environmental compatibility The product environmental declaration for 'Novigo VANSYS 3.0' contains data and information on the product's environmentally compatible design features and its ratings; for example, its RoHS conformity, composition, packaging, environmental benefits, and disposal information. You can obtain the document A6V11546319 via the following Internet address: https://siemens.com/bt/download Enter the document ID in the search field. Issued by Siemens Switzerland Ltd Division International Headquarters Theilerstrasse 1a CH-6300 Zug Tel. +41 58 724 2424 www.siemens.com/buildingtechnologies Siemens Switzerland Ltd, 2018 Technical specifications and availability subject to change without notice. 22 Document ID Edition 2018-10-22