EA003 OPTICAL TACHOMETER CALIBRATION ADAPTER OPERATION MANUAL

Similar documents
EA014 TORQUE CALIBRATION ADAPTER OPERATION MANUAL

OPERATION MANUAL SERIES MICRO BORESCOPES INSTRUMENT TECHNOLOGY, INC. POB 381, Westfield, MA Airport Road, Westfield, MA 01085

Economy Single Channel Output DC Power Supply

OPERATION MANUAL SERIES BORESCOPES INSTRUMENT TECHNOLOGY, INC. POB 381, Westfield, MA Airport Road, Westfield, MA 01085

OZONE SWITCH Model OS-6. OS-6 Features

PCM-7140 Pulsed Current Source Operation Manual

8100 SERIES ADVANCED 8.5 / 7.5 DIGIT MULTIMETER. www. transmille.com

PMDX-170 Slotted Optical Sensor

Led Illuminator and Light Stimulator. Model # LSD-1. Ver

Quick Start/Installation Guide

Automated Tuner System Power Distribution Hub

Model P4017 Single Channel USB Oscilloscope. Quick Start Guide

User Manual IXUS/ELPH camera Revision 2 / September 2014 Copyright sensefly Ltd

Table of Contents. 3.1 Front/Rear Panel and User Interface Front Panel Rear Panel User Interface...

Agilent Technologies E5339A 38-Pin Low-Voltage Probe

PIM-Mini Pulsed Current Source Operation Manual

Indoor Air Quality. Thermohygrometer. Alnor Model TH720 AIRFLOW TM Model RH720. Operation and Service Manual

Automation for Research and Industry. Robotic Shaker

Product Manual ASL Document Ref.: U doc Issue: 04 complete, approved - Date: 16/08/10 Part Number: M0618_23

Mini Photo Tachometer Model Mini Contact Tachometer Model

Densitometer DEN-1. Operating instructions. For version V.1GW

Eco Sensors OZONE CONTROLLER Model OS-6 Instructions for Use. General and New Features

LeCroy PP009 Passive Probe Instruction Manual

INSTALLATION AND USER GUIDE 2800LBY SINGLE LINE HOTEL LOBBY TELEPHONE

Fiber Optic Prism Switch USER S MANUAL

VELOCICALC AIR VELOCITY METER MODEL 5725

IAQ-CALC INDOOR AIR QUALITY METER MODEL 7525

Instructions. P MHz 10X Passive Probe

Eco Sensors OZONE CONTROLLER Model OS-6 Instructions for Use. General and New Features

Platinum RTD Thermometer MODEL NO

Operating Manual RISH DPM Hz

IAQ-CALC TM Indoor Air Quality Meter

-bio. Densitometer DEN-1B Operating instructions

LUDLUM MODEL ALPHA/BETA DETECTOR. August 2015

3000A Series. Precision Multi Product Calibrator. Operation Manual

ES-600 Ozone Controller Operation Manual

OPERATOR MANUAL OSD361 FIBER OPTIC CCTV TRANSMITTER MODULE

INSTALLATION AND USER GUIDE 2800MWB SINGLE LINE BASIC FEATURE TELEPHONE

Series RMA Hot Runner Controller Setup and Operation Manual

Series RMT Hot Runner Controller Setup and Operation Manual

TETRIS 2500 High Impedance Active Probe. Instruction Manual

PM-204A/B. Power Meter. Operation Guide

AIR VELOCITY METER ALNOR MODEL RVA501 AIRFLOW INSTRUMENTS MODEL LCA501

V ARIENSE SENSE Y O UR W ORLD. Inertial Measurement Unit VMU931. User Guide. Version 1.3. March VARIENSE INC.

SCHOTT FLM 4 Fiber Lighting Modul. Operating Instructions

VELOCICALC Air Velocity Meter

RZ2 BioAmp Processor. Operator s Manual

IAQ-CALC TM Indoor Air Quality Meter

USER MANUAL. DV-HAS HDMI Audio Separator LIT Bergen Boulevard, Woodland Park, NJ Tel FAX Web:

PMDX-105. I/O Option Riser Board User s Manual. Document Revision: 1.1 Date: 7 September 2004 PCB Revision: PCB-443A

Contents. HP E1586A Rack Mount Terminal Panel User s Manual

OPERATING AND SERVICE MANUAL. Universal Interface Device 47

HD-1X4-4K User Manual

OLS Series Light Sources, OPM Series Optical Power Meters, and Related Test Kits User s Guide

PM-100 SERIES. Operation Guide. Power Meter V

Instruction Manual LeCroy PP007-WR / PP007-WS Passive Probe

TDM-170 TIMER DISPLAY

TOUPCAM QUICK GUIDE INSTALLATION MANUAL

AIR VELOCITY METER ALNOR MODEL AVM440/AVM440A AIRFLOW INSTRUMENTS MODEL TA440/TA440A

Model 1931/2931 Series Model 1936/2936 Series

Model P4470 Save A Watt Operation Manual

LED..O..M Series Diffused On-Axis Lights

Twickenham. Scientific Instruments. The Transfer Control Module (TCM) Instruction manual, release 1.1

TiR2, TiR3, TiR4. Getting Started Guide. IR FlexCam Thermal Imager

ACCESSORIES : Double insulation Test Leads, 2 Crocodile Clips, DC 1.5V (AAA) Battery x 6, Carrying Case, User s Manual.

INSTRUCTION MANUAL. Model True RMS AC/DC 30A Mini Clamp-on Meter. Introduction. True RMS AC Current and Voltage

PROFIBUS DP Option. for FlexDrive II, Flex+Drive II and MintDrive II. Reference Manual 10/02 MN1911

9040/9040UK. Users Manual. Phase Rotation Indicator

Instruction Manual Standard Multi-Position Stirrers Advanced Multi-Position Stirrers

LeCroy PP008 Passive Probe Instruction Manual

AIR VELOCITY METER ALNOR MODEL AVM430/AVM430A AIRFLOW INSTRUMENTS MODEL TA430/TA430A

10G SFP+ Checker 2012 VER B. Page 1 of 9 3F-5, No. 30 Taiyuan Street, Chupei City, Hsinchu County 302, Taiwan

ANALOG STORAGE OSCILLOSCOPE

Chore-Tronics Mobile Server

Model NPN output PNP output Standard. configuration

User Guide. Control Box. RoscoLED TM.

User's Guide. Model High Precision Quad Output DC Power Supply

General Warranty. For more details, please refer to the user manual on the supplied CD, it can also be downloaded at

User's Guide. Extech AM A AC Analog Clamp Meter

DSTHM-2 COMBINED T AND RH DUCT TRANSMITTER. Mounting and operating instructions

OPERATING AND SERVICE MANUAL. Universal Interface Device 47

Sonic Ruptor 400. User Manual

Extended Range IR Illuminator Operator Manual

PMT 201A-RO High Impedance Passive Probe. Instruction Manual

FDCCM1-MM-L & FDCCM1-MM-R

VDS Series PC Oscilloscopes Quick Guide

Microair Avionics Pty Ltd Airport Drive Bundaberg Queensland 4670 Australia Tel: Fax:

* * Agilent Power Distribution Unit (PDU) Installation Guide

DICKSON TC200/TH300 DICKSON. Handheld Temperature and Temperature / RH Indicators. Useful Features. Applications & Product. Specifications.

SATA II HDD Canister KISS DA 435 Quick Reference Guide

PRO Owner's Manual

OFS 300 Optical Fiber Scope User s Guide

NMEA2000 DC MONITOR Part Numbers: 3410 USER MANUAL

87421/22A Power Supply. Operating and Service Manual

General Warranty. For more details, please refer to the user manual, it can be downloaded at

General Warranty. For more details, please refer to the user manual, it can be downloaded at

USB Gaming Keyboard. What your 1 year warranty means

CAPSULE MIXER. User Manual

RZ5/RZ5D/RZ6 Processor. Operator s Manual

VIP-812A DUAL NETWORKED STATION PORT

Transcription:

EA003 OPTICAL TACHOMETER CALIBRATION ADAPTER Ü

EA003 Optical Tachometer Calibration Adapter Operation Manual Version 2.00 April 2014 All product names are trademarks of their respective companies

Guarantee and service Transmille Ltd. guarantees this instrument to be free from defects under normal use and service for a period of 1 years from purchase. This guarantee applies only to the original purchaser and does not cover fuses, or any instrument which, in Transmille s opinion, has been modified, misused or subjected to abnormal handling or operating conditions. Transmille s obligation under this guarantee is limited to replacement or repair of an instrument which is returned to Transmille within the warranty period. If Transmille determines that the fault has been caused by the purchaser, Transmille will contact the purchaser before proceeding with any repair. To obtain repair under this guarantee the purchaser must send the instrument in its original packaging (carriage prepaid) and a description of the fault to Transmille at the address shown below. The instrument will be repaired at the factory and returned to the purchaser, carriage prepaid. Note : TRANSMILLE ASSUMES NO RESPONSIBILITY FOR DAMAGE IN TRANSIT THIS GUARANTEE IS THE PURCHASER S SOLE AND EXCLUSIVE GUARANTEE AND IS IN LEIU OF ANY OTHER GUARANTEE, EXPRESSED OR IMPLIED. TRANSMILLE SHALL NOT BE LIABLE FOR ANY INCIDENTAL, INDIRECT, SPECIAL OR CONSEQUENTIAL DAMAGES OR LOSS. Transmille Ltd. Unit 4, Select Business Centre Lodge Road Staplehurst Kent TN12 0QW United Kingdom Tel : +44 0 1580 890700 Fax : +44 0 1580 890711 EMail : sales@transmille.com Web : www.transmille.com Transmille Ltd. Page 2

TABLE OF CONTENTS GUARANTEE AND SERVICE... 2 EA003 OPTICAL TACHOMETER CALIBRATION ADAPTER... 4 INTEGRATED RPM MODE FOR DIRECT CONTROL... 4 EXTERNAL ADAPTER TO PROVIDE OPTICAL TRIGGERING OF TACHOMETER INSTRUMENTS... 4 OPTICAL TACHOMETER CALIBRATION ADAPTER - OPERATION... 5 Optical Tachometer Calibration Adapter Connection... 5 Starting the Optical Tachometer Calibration Option... 5 Optical Tachometer Calibration Option Operation... 6 CARE & MAINTENANCE... 8 Cleaning the Adapter... 8 Handling Precautions... 8 Servicing Information... 8 Appendix A : Specifications Transmille Ltd. Page 3

EA003 Optical Tachometer Calibration Adapter Complete solution calibrates optical tachometers up to 60,000 RPM Complete with adapter unit incorporating high intensity LED Easy to use Works with ProCal & 3000 Series Virtual Front Panel Software Simply connect the adapter to the feature connector on the 3000 series calibrator, select the RPM mode and value and point the tachometer at the high intensity LED to perform accurate and repeatable calibration, removing the need for ad-hoc setups and de-skilling calibration of these instrument types. Integrated RPM Mode for direct control The 3000 Series calibrators incorporate a dedicated RPM mode to control the optical tachometer adapter External Adapter to provide optical triggering of tachometer instruments Connects directly to the adapter interface connector on the 3000 series calibrator. Incorporates high intensity LED. Transmille Ltd. Page 4

Optical Tachometer Calibration Adapter - Operation Optical Tachometer Calibration Adapter Connection Using the supplied adapter connection lead (9 way D type to 9 way D type), connect the optical tachometer calibration adapter to the feature connection on the front panel of the 3000 series calibrator. Starting the Optical Tachometer Calibration Option To start the oscilloscope calibration option, press the softkey below the menu item RPM Thermocouple simulation mode softkey TIP : If the RPM menu item is not displayed, press the NEXT softkey to go to the next menu level. Transmille Ltd. Page 5

Optical Tachometer Calibration Option Operation The optical tachometer calibration option allows the user to enter a value directly in RPM and use the calibrator to control the optical tachometer adapter. The integrated LED is pulsed at the required frequency to simulate the RPM value entered. RPM Setting Output status (On / Standby) 1. Use the calibrator keypad to key in the required RPM, for example 3500 : 3 5 0 0 ENTER Note : Valid RPM settings are from 240 RPM to 60,000 RPM Ensure the calibrator output is turned ON by pressing the Output ON key. Note : The LED in the top left hand corner of the Output ON key will illuminate and the display will indicate ON in the left hand corner. Transmille Ltd. Page 6

2. The optical tachometer should be pointed at the LED on the adapter with no more than 20 angle to ensure consistent detection by the tachometer. Distance from the LED should also be restricted to within 5cm, again, for consistent detection. Distance 5cm max. Optical tachometer calibration times can be significantly reduced by using the ProCal calibration software available from Transmille which allows a pre-defined sequence of tests (known as a procedure) to be set up. This allows the computer to automatically step through these tests, control the calibrator, set the correct outputs and record the amount of deviation in relation to the instrument s specifications. Transmille Ltd. Page 7

Care & Maintenance The only maintenance instructions for the adapter is periodic cleaning. See below for details on the cleaning procedure and precautions for handling. Cleaning the Adapter To keep the external enclosure of the adapter in good condition, clean the outer case with a soft cloth. Do not use any liquids in cleaning the enclosure removal of surface dust is all that is recommended. CAUTION Do not use cleaning fluids or solvents for cleaning as these may damage the enclosure and affect the plastic materials used in the adapter. Handling Precautions The adapter is designed for mechanical stability, but should not be subjected to excessive shock or be dropped. Transportation is recommended using the original packaging with avoidance of extreme changes of temperature. Servicing Information The adapter is provided certified from the factory, and uses precision components and are not user repairable. If the adapter is damaged it should be returned to the factory for repair and recalibration. Transmille Ltd. Page 8

EA003 Optical Tachometer Calibration Adapter Appendix A Specifications Transmille Ltd. Page 9

EA003 Specifications General Specifications TRANSMILLE LTD Warm Up Time Double the time since last used up to 20 minutes maximum Standard Interface Transmille Adapter Interface (9 Pin Female 'D' Type connector) Temperature Performance Storage : -5 C to +60 C Operation : 0 C to +50 C Relative Humidity Operation : <80% to 30 C, <70% to 40 C, <40% to 50 C Storage : <95%, non-condensing Altitude Operation : 3000m (10,000ft) Maximum Transit : 12000m (40,000ft) Maximum Brightness 1000mcd (wavelength 660nm) Duty Cycle 20% (5:1) Connections Voltage 1x BNC connector Current 1x BNC connector Earth Connection 1x Green 4mm Safety Socket Indicators Dimensions Red LED 8mm 20 Spread Ultra bright LED mounted in the adaptor case 17cm x 12cm x 3.5cm Warranty Period 1 Year (Parts & Labour) Recommended Service Interval 1 Year Supplied Connections 1x Adapter Connection Lead Due to continuous development specifications may be subject to change. EA003 Specifications : V3.00 Page 1

EA003 Specifications Specifications TRANSMILLE LTD Range Resolution 1 Year Rel. % 60 to 60,000 RPM 6 RPM 0.0030 Specifications apply at TCal ± 5 C Outside this range an allowance of 0.18 x 1 Year Spec. per C should be added. Due to continuous development specifications may be subject to change. EA003 Specifications : V3.00 Page 2