H3 MOBILE HANDHELDS WITH INTEGRATED JMOBILE HMI SOFTWARE

Similar documents
HMI25 & HMI30. HMI Solutions based on ARM Cortex A8, Premium HMI and ASEM UBIQUITY

Brightness (cd/m 2 ) View angle (H/V) 140 / / / / / 140

exware Series Operating Instructions

S SENECA. Installation Manual Z-TWS4. Z-PC Line. Web Multifunction Controller Straton / Linux

HMI Touch Display CGHMI 4.3, 7, 10, 15

HMI Touch Display CGHMI 4.3, 7, 10, 15

Certification according to CE. C-more Touchpanels:

Operator dialogue terminals 1

BU CT Compact Product Suite Panel 800 Version 6. ABB BU CT 3BSE en Slide 1

DATA SHEET Advanced Graphical Interface, AGI 400 series

Display. Control elements

Certification according to CE. C-more Touchpanels:

dialogue terminals 1 Description 1 Magelis touch-sensitive graphic terminals New Technology, XBT GT with 7.5 screen Description

mark150s mark150/485s DDC controllers Summary

Index EA-USER-M Hardware User Manual, 2nd Ed. Rev. H, 05/18 i-2

MM-IM. Large works automation And data gateway. PRODUCT DATASHEET

Scout-S Station Controller

C-more Micro-Graphic Panel Accessories

General information. Display. Control elements

IMIO100 IMIO105. DDC controllers. Summary

Display Design of display Screen diagonal. Control elements

Operator dialogue terminals 1

HMI40 / LP40. New HMIs and PACs ARM Cortex A9 multicore processor families

Display. Control elements

PLC PFC200 Controller PFC200 CS 2ETH RS

Operator Interface Business

Turck Cloud Gateway UMTS Gateway TCG20-UMTS-1ETH-CRS-01

Panel 800 version 6 The right information at the right time, in the right place

LP31 BASIC Basic configuration > note 1

6AV6542-0CA10-0AX0. Available as a Spare Part Only - subject to availability - SIMATIC OP270 6" OPERATOR PANEL 5.7" STN COLOR DISPLAY Supply voltage

HT101. User terminal. Function

dyne Motion Control Hydraulic Pneumatic Electrical Mechanical (80 ex700 Series The Revolutionary IIoT Controller


DKG-210 UNIVERSAL INTERNET GATEWAY UNIT

USER S MANUAL TP1043 series

List of Technical Notes

HMIGK5310 Keypad-touchscreen panel color x 480 pixels VGA -10.4" - TFT LCD

DomiOP ebis504. Tech-note. Highlights

USER S MANUAL TP series

IntesisBox Modbus Server Panasonic

Food and Beverage. The Real World, True Standard

SIMATIC KTP600 BASIC COLOR PN 5,7" TFT DISPLAY, 256 COLORS ETHERNET INTERFACE CONFIGURATION FROM WINCC FLEXIBLE 2008 COMPACT SP1 OR WINCC BASIC V10

HMI HUMAN MACHINE INTERFACE

DATA SHEET DEPRECATED - PCM5 1. Document no.: N/A

ex700 Series Operating Instructions

Flexy IIOT GATEWAY AND REMOTE ACCESS ROUTER DATASHEET. Highlights. Typical Applications. IIoT gateway with most PLC protocols

What s new in AO 2.33? April Think Automation and beyond

MINER-S Station Controller

General information. Display. Control elements


General information. Display. Control elements

extending the boundaries of technology evolution of proven technology FEATURES

i 2 Index Communications Ports, 2 6 Conventions Used, 1 3 exclamation mark, 1 3 notepad, 1 3

Panel 800 Version 6 The right information at the right time, in the right place

JMobile V2.6 SP1 Release Notes

CLIMATIX STEQ, STCM DATASHEET FOR CONTROLLING, SWITCHING AND MONITORING FUNCTIONS. POWER SUPPLY RELAY OUTPUTS. Power supply. 4.

C-more 3 Micro-Graphic STN Touch Panel

ex700 Series Operating Instructions

General information. Display. Control elements

C-more Micro-Graphic Power Connection Wiring

HMISTO " wide screen touch panel, Ethernet

General information. Display. Control elements

RENU. FlexiLogics FL050. Flexible PLC Salient Features :- DIN rail / Back panel mounted compact PLC. Up-to 2 Serial Ports, 1 USB Device Port

Omron FINS Ethernet Driver for JMobile

Flexy. MODULAR INDUSTRIAL IOT ROUTER AND DATA GATEWAY PRODUCT DATA SHEET. Highlights. Typical Applications

General information. Display. Control elements

Ovation Ethernet Link Controller Module Data Sheet

Preface. For the replacement of GP-2601T, 2501S, please refer to GP2000 series replacement booklet. Third Edition: Feb /38

Product type designation. Display. Control elements

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

Mitsubishi FX Ethernet Driver for JMobile

MID Energy Counters. Getting together is a beginning, staying together is a progress, working together is an achievement.

AC 800M for Compact Product Suite Outline of all modules

HMIGTO2310 advanced touchscreen panel 320 x 240 pixels QVGA- 5.7" TFT - 96 MB

General information. Display. Control elements

TBEN-L Multiprotocol Module for Ethernet Compact RFID and I/O Module Programmable via CODESYS V3 with WebVisu License TBEN-L5-4RFID-8DXP-CDS-WV

C-more Micro-Graphic Specifications

Installation Instructions

HMIGTO1310 advanced touchscreen panel 320 x 240 pixels QVGA- 3.5" TFT - 96 MB

Installation Instructions

XBTGT6330 advanced touchscreen panel x 600 pixels SVGA " - TFT LCD - 24 V DC

HMIGTO6315 advanced touchscreen panel stainless 800 x 600 pixels SVGA- 12.1" TFT - 96 MB

Food and Beverage. The Real World, True Standard

6AV6545-0BB15-2AX0. Software clock, synchronizable, no battery backup

INGEPAC DA-CU. Control Unit. Data Sheet ZY8932IMA01E 31/03/2016

General information Customer-specific configuration

6AV6542-0BB15-2AX0. Software clock, synchronizable, no battery backup

Touch screen operator unit

HMIGTO6310 advanced touchscreen panel 800 x 600 pixels SVGA- 12.1" TFT - 96 MB

HMI30 BASIC Basic configuration > note 1

ATV340D75N4E variable speed drive - 75kW- 400V - 3 phases - ATV340 Ethernet

SMIC Smart Cable Installation and Connection Guide

Datasheet: com.tom INDUSTRY

XBTGT4340 advanced touchscreen panel x2 40 pixels QVGA - 7.5" - 24 V

F1000 User's Manual. (Version: V1.01)

HMI30 BASIC Basic configuration > see note 1

Wireless Gateway ARG600 Product Guide

XBTGT6340 advanced touchscreen panel x 600 pixels SVGA " - 24 V

RENU. FlexiLogics FL010. Flexible PLC Salient Features :- DIN rail / Back panel mounted compact PLC. Up-to 2 Serial Ports, 1 USB Device Port

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

Transcription:

H3 MOBILE HANDHELDS WITH INTEGRATED JMOBILE HMI SOFTWARE

TABLE OF CONTENTS ˉ ˉ ˉ ˉ ˉ ˉ ˉ H3 HANDHELDS THE BEST MOBILE HMI CHOICE HANDHELD DEVICES AND ERGONOMICS OPTIONAL COMPONENTS HARDWARE AND SOFTWARE SPECS STANDARDS AND DIRECTIVES HOW TO ORDER CONCLUSIONS AND CONTACTS

ONE H3 HANDHELD SERIES + INTEGRATED JMOBILE SOFTWARE STUNNING DESIGN/ERGONOMICS MULTIPLE INTEGRATED DEVICES (KEYS/POTENTIOMETERS/HANDWHEEL/STATE SELECTOR) EASY TO PROGRAM EASY TO CONNECT 30 YEARS MANUFACTURING EXPERIENCE A-LEVEL SERVICE THE PERFECT HMI CHOICE FOR YOUR MACHINE INTEGRATED HW/SW FOR LOW DEVELOPMENT COSTS

THE MOBILE HMI FOR AUTOMATION & MACHINERY UP TO 20 METERS CABLE

HANDHELD DEVICES AND ERGONOMICS

16 positions state selector (hardwired) 2 programmable potentiometers Emergency stop button Optional integrated handwheel 19 programmable physical keys IF Design Award for design and ergonomics Touchscreen EVERYTHING YOU NEED AT YOUR FINGER TIPS FULL CONTROL IN 700 GRAMS

Hanging magnets Safety enabling device Hand strap REAR HANGING MAGNETS HANG IT WHEREVER YOU NEED

OPTIONAL COMPONENTS

INTEGRATED HANDWHEEL 40 PULSE/ROTATION

HANDHELD HOLDER EASILY HOLD YOUR HANDHELD

CONNECTION BOX EASILY CONNECT YOUR HANDHELD

Standard cable comes with free termination. Connection Box organizes wires inside the electrical cabinet using a fast-snap circular connector. 19 wires enter the connection box and are divided into safety (emergency stop button, enabling device, state selector) and data (RJ45 for Ethernet) CONNECTION BOX CONNECTION SCHEME

HARDWARE AND SOFTWARE SPECS

Hardware specifications -600MHz ARM Cortex-A8 -Embedded Graphic engine -Flash Memory: 128MB Flash -RAM Memory: 256MB DDR -Display Dimensions: 5 -Colors: 64K -Resolution: RGB 480 x 272 -USB interface: USB A (Host) Cable connection - SERIAL: RS-232/RS-422/RS-485 software configurable - ETHERNET: 10/100 Mbit - Cable length (serial/ethernet): 10, 20 mt EXOR STANDARD HARDWARE GREAT RELIABILITY AND SERVICE

ONE Power Jmobile run time* To run your powerful HMI and connect to the main controller by means of more than 35 built in automation protocols. More then 35 built in protocols A-B DF1, A-B DH-485, A-B ENET, Baldor NextMove, Beckhoff ADS, CODESYS V2 SER, CODESYS V2 ETH, CoDeSys V3 ETH, Panasonic FP, EIA Modbus TCP, EtherNet/IP CIP, Fatek FACON ETH, Fatek FACON SER, GE Intelligent Platforms SNP, GE Intelligent Platforms SRTP, Hitachi ETH, Hitachi SER, Jetter Ext ETH, Keyence KV, Koyo DL, Mitsubishi FX ETH, Mitsubishi FX SER, Mitsubishi Q/L ETH, Modbus TCP Server, CT Modbus CMP EHT, RTU Server, Modbus TCP, Modbus RTU, NMEA 0183, Omron FINS ETH, Omron FINS SER, ProConOS ETH, Simatic S7 Ethernet, Simatic S7 PPI. * Also available with WIN CE OS to install third party HMI SW INTEGRATED JMOBILE RUNTIME YOUR POWERFUL HMI

Chose your model and start defining the graphical lay out with DRAG&DROP EDITING ONE POWER JMOBILE STUDIO THE DRAG&DROP HMI EDITOR

Assign variables, keys, potentiometers, handwheel, and everything else WITHIN THE EDITOR ONE POWER JMOBILE STUDIO FULLY AUTOMATED EDITING

SOME HMI EXAMPLES COMPLETELY CUSTOMIZABLE

Axes quotes, distance to go, following error Axes speed % Axes speed Spindle feed % Spindle state PLC error messages CNC specific commands MACHINE TOOL HMI EXAMPLE COMPLETELY CUSTOMIZABLE

STANDARDS AND DIRECTIVES

DIRECTIVE 2004/108/EC Electromagnetic Compatibility Directive (EMC) STANDARDS (EMC) EN 61000-6-2 Electromagnetic Compatibility (EMC) Part 6-2: Generic Standards - Immunity for Industrial Environments EN 61000-6-4 Electromagnetic Compatibility (EMC) Part 6-4: Ge-neric Standards - Emission for Industrial Environments Degrees of protection and environmental tests EN 60529 + A1 Degrees of protection provided by enclosures (IP code: 64) Emergency Stop Push-button conforming to: IEC 60947-5-5, 6.2 Safety Lock Mechanism IEC 60947-5-5, 5.2 IEC 60947-5-1, Annex K Direct opening action mechanism EN ISO13850, 4.2, 4.3, 4.4 Enabling Device conforming to: IEC 60947-5-1 EN 60947-5-1 JIS C8201-5-1 IEC 60947-5-8 Low-voltage switchgear and controlgear EUROPEAN DIRECTIVES AND RELEVANT STANDARDS COMPLIANT WITH RELEVANT DIRECTIVES/STANDARDS

HOW TO ORDER

H3 COMMON ORDERING CODES 10 MT ETHERNET CABLE + JMOBILE= +EP3H3REJ200YE1 20 MT ETHERNET CABLE + JMOBILE = +EP3H3REJ400YE1 10 MT ETHERNET CABLE + JMOBILE + HANDWHEEL = +EP3H3REJ2H0YE1 20 MT ETHERNET CABLE + JMOBILE + HANDWHEEL = +EP3H3REJ4H0YE1 10 MT SERIAL CABLE + JMOBILE = +EP3H3RSJ200YE1 10 MT SERIAL CABLE + JMOBILE + HANDWHEEL = +EP3H3RSJ2H0YE1 10 MT ETH.+JMOBILE+HANDWHEEL+CIRC.CONNECTOR= +EP3H3REJ2H0YE2 20 MT ETH.+JMOBILE+HANDWHEEL+CIRC.CONNECTOR= +EP3H2REJ4H0YE2 CONNECTION BOX H3 + CIRCULAR CONNECTOR= +EP3H00000X0YA2 STANDBY STATION H3 HOLDER = +EP3H00000B0YA0 CONNECTION BOX= +EP3H00000X0YA2 HOLDER = +EP3H00000B0YA0 COMMON ORDERING CODES ETHERNET BEST FOR NEW APPLICATIONS

CONCLUSIONS

ONE H3 HANDHELDS SERIE + INTEGRATED JMOBILE SOFTWARE STUNNING DESIGN/ERGONOMICS MULTIPLE INTEGRATED DEVICES (KEYS/POTENTIOMETERS/HANDWHEEL/STATE SELECTOR) EASY TO PROGRAM EASY TO CONNECT 30 YEARS MANUFACTURING EXPERIENCE A-LEVEL SERVICE THE PERFECT HMI CHOICE FOR YOUR MACHINE INTEGRATED HW/SW FOR LOW DEVELOPMENT COSTS

THANK YOU (FOR FURTHER INFO SEE CONTACTS BELOW) 0N3 SRL VIA MONTE FIORINO, 9 - SAN GIOVANNI LUPATOTO (VR) ITALY - TEL +39 045 8774849 info@0n3.eu / 0n3.eu / jmobile.net