Series AMEPR60C-AZ up to 5A AC-DC / DC-DC LED Driver / Converter

Similar documents
Series AMER120-AZ up to 5A AC-DC / DC-DC LED Driver / Converter

Series AMEPR30D-AZ up to 2A AC-DC LED driver

Series AMEL10-MJZ 10 Watt AC-DC / DC-DC Converter

Series AME25-JZ 25 Watt AC-DC / DC-DC Converter

Series AME60-MJZ 60 Watt AC-DC / DC-DC Converter

Series AME5-CJZ 5 Watt AC-DC / DC-DC Converter

Series AMES40-MAZ 40 Watt AC-DC / DC-DC Converter

Series AMEL20-AZ 20 Watt AC-DC / DC-DC Converter

Series AMEL5-MAZ 5 Watt AC-DC / DC-DC Converter

Series AME10-VZ 10 Watt AC-DC / DC-DC Converter

Series AMEL20-MAZ 20 Watt AC-DC / DC-DC Converter

Series AM1S-Z 1 Watt DC-DC Converter

Series AM3G-NZ 3 Watt DC-DC Converter

Series AM1M-NZ 1 Watt DC-DC Converter

Series AM4T-Z 4 Watt DC-DC Converter

Series AM20EW-NZ 20 Watt DC-DC Converter

VP ELECTRONIQUE MASSY - Tel

Model No. ( Single Output ) ATC-3.3S ATC-5S ATC-12S ATC-15S ATC-24S Max Output Wattage (W) 10W 10W 10W 10W 10W VAC or VDC

Constant Voltage Mode

SAM Listed LED Optimized Drivers. Environmental. Electrical Specifications at 25 O C E Output Current. Voltage Accuracy

Universal Power Supplies

Electrical Specifications VAC/390 VDC, Universal (Derate from 100% at 100V AC to 77% at 80V AC)

SAM Listed LED Optimized Drivers. Environmental. Electrical Specifications at 25 O C E Output Current. Voltage Accuracy

MPO-120S Series. Single Output, 180W Compact, Open Frame AC/DC Power Supplies. Key Features:

5 x 8.5 x 1.61 Inch Form Factor. Convection Cooling Rated. Approved to EN Dual Fusing. Current Sharing. Open Frame. Peak Power Capability

SAM Listed LED Optimized Drivers. Environmental. Electrical Specifications at 25 O C E Output Current. Voltage Accuracy

These power supplies are ideal for telecom, datacom, industrial equipment and other applications.

Typical Efficiency (2) 0 ~ 12.5 A 150 W 90.0% EUV-150S012DTA(STA) 0 ~ 6.25 A 150 W 90.5% EUV-150S024DTA(STA) (4)

VER05 Series. xxx Series. 5 Watt. AC-DC Power Supplies. Models & Ratings. Input. Output

Electrical Specifications VAC/390 VDC, Universal (Derate from 100% at 100V AC to 77% at 80V AC)

Watts. xppower.com. General. Input. Environmental. EMC & Safety. Output. IT & Medical Approvals. Energy Efficiency Level V, CEC2008 & EISA 2007

Features. Applications and Benefits TRC ELECTRONICS, INC

Features. Regulated Converter. RAC35-G/OF 35 Watt 4 x 2 Open Frame RAC35- SG/OF. AC/DC Converter

4 x 2 x 0.75 Inches Form factor. 180 Watts with Forced Air Cooling. Approved to EN/IEC Efficiencies up to 92% Standby Power < 0.

MPU-120S Series. Single Output, 180W Compact, U-Channel AC/DC Power Supplies. Key Features:

Ripple & Noise (max) (See Note 2) 5V output: 100mVp-p; 12V - 27V outputs: 150mVp-p; 48V output: 200mVp-p

LFWLP350 SERIES 350 Watt Open Frame Power Supply Measures: 5.00 x 3.00 x 1.00

Max. Output Power. Typical Efficiency (3) 0 ~ 25.0 A 300 W 91.5% 0.96 EBV-350S012SV 0 ~ 14.6 A 350 W 93.5% 0.96 EBV-350S024SV

FS50W Series LED Driver Input: VAC High Power Factor High efficiency For high bay light IP66 UL CB CE SPECIFICATIONS

Environmental. Electrical Specifications at 25 O C E Output Constant Current

Enclosed Power Supplies

Environmental. Electrical Specifications at 25 O C E Output Constant Current

SAMSUNG ELECTRO-MECHANICS CO., LTD

Electrical Specifications VAC/390 VDC, Universal (Derate from 100% at 100V AC to 95% at 85V AC)

Universal input VAC <150mW No load power consumption

LFWLP225 SERIES 225 Watt Open Frame Power Supply Measures: 4.00 x 2.00 x 1.00

Gelo LED Driver 100W, Single output, Constant Voltage RGLD100-24

Snaptec Australia Pty. Ltd.

Parameter Condition Min. Typ. Max. Internal Input Filter. nom. Vin = 230VDC 115VAC 230VAC 115VAC 230VAC. No load Power Consumption

60 Watt Medical (MWLT)

IEC/EN/UL60950 & CE certified, EN55032 Class B

LFMWLP225 SERIES 225 Watt Open Frame Power Supply Measures: 4.00 x 2.00 x 1.00

Max. Output Power(2) Typical Efficiency (3) 0 ~ 18.4 A 220 W 91.5% 0.96 EBV-250S012SV 0 ~ 10.5 A 250 W 93.0% 0.96 EBV-250S024SV

Electrical Specifications VAC/390 VDC, Universal (Derate from 100% at 100V AC to 90% at 90V AC)

AC-DC POWER SUPPLIES UNIVERSAL INPUT, 65 WATT MEDICAL APPLICATIONS MUI65 SERIES

< 50 A max. (115 VAC) / < 70 A max. (230 VAC)

Output Voltage* (nom.)(adjustable)

275 Watt Medical Ultra low profile

Notes: Note1: Other output voltages on request Note2: Efficiency is tested at nominal input (115/230VAC) and full load at +25 C ambient

Gelo LED Driver 100W, Single output RGLD100-24

TMP & TMPM Series, 4 to 60 Watt. Order code Output power max. Output Efficiency

Output Current Input Current Max. capacitive Load

12-15VDC (12V±5%) 24-28VDC (24V±5%)

VEL05 Series. xxx Series. 5 Watt. AC-DC Power Supplies. Models & Ratings. Input

Power Factor Model Number Voltage Voltage

40 & 60 Watt Models. Low Leakage Current. EN61000 Compliant. Single & Multiple Outputs. Cover Kits Available

Parameter Condition Min. Typ. Max. Internal Input Filter 115VAC 230VAC 115VAC 230VAC. No load Power Consumption

Application Package Dimension Output Input Output Output Protection Option Code Code Power Voltage Quantity Voltage Type (W) (VAC) (VDC)

APM-40 SERIES FEATURES PRODUCT OVERVIEW. Model Selection Guide. Input Specifications. AC/DC Power Module 40W, Industrial & Medical Safety

Typical Efficiency (2) 350 ma 90 ~ 305 Vac 57~114Vdc 160 W 92.0% EUC-160Q035DT(ST) (3 ) Parameter Min. Typ. Max. Notes

Series Specifications Ta= 25 C, nom. Vin, full load and after warm-up unless otherwise stated) Parameter Condition Min. Typ. Max.

VEL05 Series. xxx Series. 5 Watt. AC-DC Power Supplies. Models & Ratings. Input

Note1: Typ. efficiency is 230VAC and full load 12VDC 24VDC 48VDC ms 8ms 16ms 80ms

Output Voltage* (nom.)(adjustable)

Output Voltage Range. Power ma ma 700 ma 176~305 Vac 155~343 Vdc 240 W 94.0% 0.98 EBD-240S105DV

SPECIFICATIONS: PSAK650

Universal input VAC <250mW No load power consumption -25 C to +80 C Operating temperature, with derating

EPT W 5V 2.4A ±5% EPT W 7V 1.71A ±5% EPT W 9V 1.5A ±5% EPT W 12V 1.25A ±5% EPT W 15V 1.0A ±5%

efo Series Wide range AC/DC Single Output 1000W Rugged Power Supply Electrical Specification for: Telkoor Part Number:

Typical Efficiency (2) Max. Output Power. 700 ma 140 ~ 305 Vac 107 ~ 214 Vdc 150 W 92.0% 0.96 EDC-150S105SV-0007

C B. Models. Operating up to 5000m altitude 5 year product warranty

MPM-U653-DCF-B M/N: MPM-U653-DCF-B. 650W Medical AC / DC SPECIFICATION FOR SWITCHING POWER SUPPLY. Revision History

POWERBOX Industrial Line PMR20W Series 20W 4:1 Single and Dual Output High Performance DC/DC Converter

Typical Efficiency (2) Max. Output Power ma 176 ~ 305 Vac 260~400Vdc 420 W 94.0% 0.95 EBC-420S105DV(SV)

Efficiency (1) 110Vac 220Vac

Efficiency (1) 110Vac 220Vac

Industrial Power Supplies

Output Voltage Range. Power ma ma 700 ma 176~305 Vac 97~214 Vdc 150 W 93.0% 0.98 EBD-150S105DVA

Electrical Specifications. Input Current 115 VAC: 1 A max. 230 VAC: 0.5 A max.

12-15VDC (12V±5%) 24-28VDC (24V±5%)

C B. Models. Ultra wide 4:1 input voltage 20 W DC/DC. edition and EN55032 class A

Feature Ultra High Efficiency (Up to 94%)

Efficiency (1) 110Vac 220Vac. (2, 3) 3330 ma 90 ~ 305 Vac 11 Vdc 35 W 84% EUC-040S333DS(6) EUC-040S333PS(6)

ENGINEERING SPECIFICATION. 40W AC Adaptor. Part Number: PA W1

Output Voltage Range. Max. Output Power ma ma 700 ma 176~305 Vac 43~107 Vdc 75 W 90.5% 0.98 EBD-075S105DV

Typical Efficiency (2) 500 ma 90 ~ 305 Vac 32~64 Vdc 32 W 87.0% EUC-035S070SVM0004

FEATURES. Nominal Output Voltage and Current

Output Voltage in Constant Voltage Mode. Model Number

Specification For 90 Watts Adapter Power Supply Model No: ADB002 Customer ID: 000G Revision: 4.0

Typical Efficiency (2) Max. Output Power. 700 ma 160~305 Vac 30~60 Vdc 42 W 88% 0.95 EBC-042S105DV(SV)-0007

Transcription:

Click on Series name for product info on aimtec.com Series AMEPRC-AZ Models Single output Model Max Output Power (W) 1 FEATURES: Output Voltage Range (V) 3 Output Current 3 AMEPRC-120AZ 36-0 - 1.20 AMEPRC-361AZ 59.8 24-36 0-1. AMEPRC-242AZ 12-24 0-2. AMEPRC-120AZ 5-12 0-5.0 AC-DC Constant Current or Constant Over Temperature Protection Voltage LED Driver Over Current Protection Input range -5VAC/47-4Hz Waterproof Case rated IP68 High Efficiency up to 86% Power Factor Correction Operating temperature - to 85 C Short Circuit Protection Dimmable via resistive / 0-10Vdc / PWM 5 Years Limited Warranty OC P / OV P Input Voltage (VAC/Hz) Input Voltage (VDC) Mode of Operation 115 VAC Efficiency (%) 1.27-5/47- Constant Current 84 86 86.7 1-4 4 Constant Voltage 2 84 86 86 1.77-5/47- Constant Current 84 86 86 36.6 1-4 4 Constant Voltage 2 84 86 86 2.55-5/47- Constant Current 82 83 83 24.5 1-4 4 Constant Voltage 2 82 83 83 5.2-5/47- Constant Current 79 81 12.3 1-4 4 Constant Voltage 2 79 81 2 VAC 277 VAC 1 Exceeding the maximum output power will permanently damage the converter 2 The dimming feature is not supported when units are used in Constant Voltage mode only. 3 In constant current mode output current is maximum shown, in constant voltage mode output voltage is the maximum shown. All models can be ordered with optional North American colour input wires (black (L), white (N), green (GND)). Add NA to part number when ordering. Note: Aimtec limited warranty of 5 years is valid based on product operation at datasheet specifications at ambient temperature of 25 C, humidity<75%, nominal input voltage (115/2/277VAC) and at rated output load unless otherwise specified. See http://www.aimtec.com/terms-sale AMEPRC-AZ s AC/DC LED drivers have electrical safeguards designed within to protect it from conventional electrical abnormalities with the levels listed in the safety table. Applications for use within rural agricultural, heavy industrial, and other areas or regions which are prone to dirty electrical conditions which would subject any of the above models to excessive voltages surges or spikes, may damage or cause early life failure of product. In this case consideration should be made by the end user to ensure that adequate line or mains surge suppression is installed in front of Aimtec device to ensure the longevity of the products. Failure to identify excessive line surges violations prior to installation may damage sensitive equipment permanently. Input Specifications Parameters Conditions Typical Maximum Units Inrush current <2ms 115VAC 2VAC A Leakage current 115VAC 0.5 2VAC 0.7 ma AC current 115VAC 0.73 2VAC 0.33 A 115VAC 0.98 Power Factor 2VAC 0.96 277VAC 0.93 External fuse 2V/1.5A Start up time 2 ms Surge voltage 2sec 4 V Output Specifications Parameters Conditions Typical Maximum Units Current accuracy (CC Mode) ±3 % Voltage accuracy (CV Mode) ±3 % Line regulation LL-HL ±1 % F 052.1e R3.I 1 of 13 North America only

Load regulation 0-100% load ±3 % Ripple & Noise 4 20MHz Bandwidth 75 mv p-p Hold-up time ms Current adjustment range 100-10 % Minimum Load Voltage See the models table 4 Tested with 0.1µF (C/C) or (M/C) and 47µF (E/C) parallel capacitors at the end. Isolation Specifications Parameters Conditions Typical Rated Units Tested I/O voltage 3 sec/3.5ma 00 VAC Isolation Resistance 0VDC >1000 MΩ Isolation Capacitance 1000 pf General Specifications Parameters Conditions Typical Maximum Units Switching frequency 1 KHz AMEPRC-120AZ 1.27 Over current protection AMEPRC-361AZ 1.77 AMEPRC-242AZ 2.55 A AMEPRC-120AZ 5.2 Over voltage protection Refer to Constant Current vs. Constant Voltage Mode curve Short circuit protection Continuous Short circuit restart Auto recovery Over temperature protection >105 C Operating temperature With derating over 55 C - to +85 o C Maximum case temperature 100 o C Storage temperature - to +95 o C Temperature coefficient ±0.02 % / o C Cooling Free air convection Humidity 95 % RH Case material Plastic Potting Epoxy (IP67 rated) Wires UL1015 18AWG *20CM Weight 5 g Dimensions (L X H X W) 5. x 2.27 x 1.59 inches 134. x 57.68 x. mm MTBF >0,000 hrs (MIL-HDBK-217F at +25 C) Safety Specifications Parameters Agency approvals Standards culus, CE UL87, UL9-1, EN522, class B, EN529(IP68), EN61347-1, EN61347-2-13 Information Technology Equipment EN522 Class B Harmonic Current Emissions IEC/EN 61000-3-2, Class C Voltage fluctuations and flicker IEC/EN 61000-3-3, (EN555-3) Electrostatic Discharge Immunity IEC 61000-4-2 Level 3 RF, Electromagnetic Field Immunity IEC 61000-4-3 Level 2 Electrical Fast Transient / Burst Immunity IEC 61000-4-4 Level 2 Surge Immunity IEC 61000-4-5 Level 3 RF, Conducted Disturbance Immunity IEC 61000-4-6 Level 2 Power frequency Magnetic Field Immunity IEC 61000-4-8 Level 1 Voltage dips, Short Interruptions Immunity IEC 61000-4-11 F 052.1e R3.I 2 of 13 North America only

Dimensions Top View 137.33 (5.41) End View. (1.59) 16.75 (0.66) 6 (2.36) 3 6 (1.26) (2.36) Side View. (1.59) 20 (8.00) 20 (8.00) Input/Output Wires are 18 AWG 20cm 161. (6.35) 2. (0.09) Wire connection: Wire Brown Blue Green Red Black Blue (Dimming) White (Dimming) Connection AC L AC N Ground +V output -V Output + Vs dimming -Vs dimming Temperature Graph Free Air Convection 100 55 º C Output Power % 20 Safe Operating Area 0 85 - -20 0 20 100 Ambient Temperature º C F 052.1e R3.I 3 of 13 North America only

Dimming Control C Versions AMEPRC-120AZ 1. 1.20 0. 0. 0. 0.20 0 10 20 Dimming-Resistance VS Output Current 100 0 20 100 120 K(Ω) 1. 1.20 0. 0. 0. 0.20 Dimming-PWM VS Output Current 95 6 10 20 0 20 100 120 (Duty%) 1. Dimming- 0-10Vdc VS Output Current 1.20 9.00 1 8.00 0. 7.00 0. 0. 0.20 8.00 1 1 (V) F 052.1e R3.I 4 of 13 North America only

AMEPRC-361AZ 1. 1. 1. 1.20 0. 0. 0. 0.20 0 10 20 Dimming-Resistance VS Output Current 0 20 100 120 K(Ω) 100 1. 1. 1. 1.20 0. 0. 0. 0.20 Dimming-PWM VS Output Current 95 20 6 10 0 20 100 120 (Duty%) Dimming- 0-10Vdc VS Output Current 1. 1 1. 9.00 1. 8.00 1.20 7.00 0. 0. 0. 0.20 8.00 1 1 (V) F 052.1e R3.I 5 of 13 North America only

AMEPRC-242AZ 2. 1. 0. Dimming-Resistance VS Output Current 100 20 0 10 0 20 100 120 K(Ω) 2. 1. 0. Dimming-PWM VS Output Current 95 20 6 10 0 20 100 120 (Duty%) Dimming- 0-10Vdc VS Output Current 2. 1 8.00 9.00 1. 7.00 0. 8.00 1 1 (V) F 052.1e R3.I 6 of 13 North America only

AMEPRC-120AZ Dimming-Resistance VS Output Current 100 20 0 10 0 20 100 120 K(Ω) Dimming-PWM VS Output Current 95 6 10 20 0 20 100 120 (Duty %) Dimming- 0-10Vdc VS Output Current 1 9.00 8.00 7.00 8.00 1 1 (V) F 052.1e R3.I 7 of 13 North America only

Efficiency Vs. Input Voltage & Output Current (Constant current load) AMEPRC-120AZ Series AMEPRC-AZ (%) Efficiency Vs. Input Voltage & Output Current 110Vac, 0.24, 81.4 2Vac, 1.2, 110Vac 110Vac, 88.01.2, 2Vac 87.9 2Vac, 0.24, 74.0 AMEPRC-361AZ (%) Efficiency Vs. Input Voltage & Output Current 110Vac, 0.34, 81.4 2Vac, 110Vac 1.7, 110Vac, 88.01.7, 2Vac 87.9 2Vac, 0.34, 74.6 F 052.1e R3.I 8 of 13 North America only

AMEPRC-242AZ (%) Efficiency Vs. Input Voltage & Output Current 110Vac, 0.5, 81.7 2Vac, 2.5, 110Vac 87.0 2Vac 110Vac, 2.5, 85.4 2Vac, 0.5, 78.1 AMEPRC-120AZ (%) Efficiency Vs. Input Voltage & Output Current 2Vac, 5, 110Vac 84.9 110Vac, 5, 2Vac 83.9 110Vac, 1, 73.4 2Vac, 1, 72.9 F 052.1e R3.I 9 of 13 North America only

PFC Value vs. Output Load Current (constant current mode) AMEPRC-120AZ Series AMEPRC-AZ (value) PFC value Vs. Output Load Current 115VAC, %, 0.98 115VAC, 115VAC 100%, 2VAC 2VAC, 100%, 0.96 2VAC, %, 0.91 (load) AMEPRC-361AZ (value) PFC value Vs. Output Load Current 115VAC, %, 0.98 115VAC, 115VAC 100%, 0.992VAC 2VAC, 100%, 0.96 2VAC, %, 0.88 (load) F 052.1e R3.I 10 of 13 North America only

AMEPRC-242AZ (value) PFC value Vs. Output Load Current 115VAC, %, 0.98 2VAC, %, 0.77 115VAC, 115VAC 100%, 2VAC 2VAC, 100%, 0.94 (load) AMEPRC-120AZ F 052.1e R3.I 11 of 13 North America only

Constant Current vs. Constant Voltage Mode AMEPRC-120AZ Constant Current Vs. Constant Voltage 36 36, 1.21, 1.22 38.4, 52, (V) AMEPRC-361AZ Constant Current Vs. Constant Voltage 24 24, 1.71 36, 1.73 26 28 36.4, 38, (V) F 052.1e R3.I 12 of 13 North America only

AMEPRC-242AZ Constant Current Vs. Constant Voltage 12 12, 2.51 24, 2.53 14 16 24.5, 26, (V) AMEPRC-120AZ Constant Current Vs. Constant Voltage 5 5, 5.04 12, 5.02 6 7 12.3, 14, (V) NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25 C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec s standard Terms of Sale available at www.aimtec.com. F 052.1e R3.I 13 of 13 North America only