Universal Contact Input Adapter M 3908

Similar documents
Application Guide. M 2174B Moloney Replacement Adapter Panel

Autodaptive Capacitor Control M 2501B

Rugged MediaConverter

M-5072 Retrofit Kit For M-4272 Digital Motor Bus Transfer System

Application Guide. M-2053 Adapter Panel

Model 7705 Control Module

Digital Tapchanger Control M-2001B

The Programmable 4-Way Relay Card is an optional peripheral unit that provides four individually programmable relay output circuits.

HID. GE Consumer & Industrial Multilin. High Impedance Differential Module Instruction manual GEK Copyright 2005 GE Multilin

300 WATT, PFC, OPEN FRAME POWER SUPPLIES TABLE 1. OUTPUT RATINGS AND SPECIFICATIONS, RMW 300W SERIES

Switching Control Sentinel (SCS) TM For all ABB independent pole operated circuit breakers

PGR-2601 MANUAL DC GROUND-FAULT RELAY

satech TSB-14 MAIN FEATURES

ICS Regent. Relay Output Modules. Low Power and High Power (T3446L and T3446H) PD-6017

HV-CS kv Edge Mount Triaxial Jack

Application Guide. M-2067 Adapter Panel

MXIO. Compact I/O module. Summary. Application Compact I/O module for data acquisition and HVAC control systems. Function

Masibus Automation And Instrumentation Pvt. Ltd.

Installation & Operation Guide

3710 ACM 3750 PDC 3800 RTU. ISOCOM Communications Card Retrofit Instructions

Providing the missing piece in your Condition Based Monitoring platform

Residual overvoltage relay

Thermistor motor protection relays CM-MSS.22 and CM-MSS.23

TeSys IEC Contactors and Overload Relays

KEPCO SINGLE OUTPUT, 1U SIZE, 100 WATT HOT SWAP PLUG-IN POWER SUPPLIES TABLE 1. OUTPUT RATINGS AND SPECIFICATIONS, HSF-1UR 100W SERIES

CONTROL MICROSYSTEMS and 5407 Relay Output Module. Hardware Manual

Arc protection relay. Features Three-phase overcurrent function. Application

CompactBlock Guard I/O EtherNet/IP Safety Modules

Reference Manual EPM-PS1. PC/104-Plus Power Supply Module DOC. REV. 4/29/2009

FL MC 2000E (SM40) LC

MODEL SW6000 & SM6100 CENELEC INSTRUCTIONS

SLATE. Digital I/O Module INSTALLATION INSTRUCTIONS R8001D4001

Earth-fault Relay SPAJ 110 C. Product Guide

Thermistor motor protection relays CM-MSS.32 and CM-MSS.33

Series Watt DC Power Supplies

SmartBlock I/O Module HE579MIX577/977 Isolated 4/8 Analog Inputs 2/4 Analog Outputs

QUALITROL QTMS Transformer Monitoring System

Sensitive Earth-fault Relay SPAJ 111 C. Product Guide

MODEL: R1M-P4. PC Recorders R1M Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.)

E1 Plus Electronic Overload Relay

Graphic Display Unit/Human Machine Interface M 3919A

Electronic timer CT-ERS.12 ON-delayed with 1 c/o contact Data sheet

Electronic timer CT-AHD.22

Electronic timer CT-ERD.12

SE-701 MANUAL GROUND-FAULT MONITOR

Tempco Instruction Manual

Electronic timer CT-ARS.11

Electronic timer CT-ERS.21

ADVANCED MICRO SYSTEMS

Thermistor motor protection relays CM-MSS.12 and CM-MSS.13

COM32. Installation & Operation Manual

SIMOCODE 3UF Motor Management and Control Devices

Thermistor motor protection relays CM-MSS.22 and CM-MSS.23

NI REM Remote I/O Overview DATASHEET. Digital Input Module for Remote I/O

www. ElectricalPartManuals. com Protective Relays PROTECTION AND CONTROL FUNCTIONS ADVANCED CAPABILITIES

24973 Circuit Breaker MINIATURE CIRCUIT BREAKER, 440VAC, 10A, CIRCUIT BREAKER TYPE: STANDARD

SmartBlock I/O Module HE579MIX102 Isolated 6 Relay, 12 DC Inputs, 4 Analog Inputs

5B Series 16 Channel Backplane 5B01 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

High impedance protection relay

Thermistor motor protection relay CM-MSS.31

TU531, TU532 Terminal Unit

Application Guide. M-2264B Application Guide

Type VRLTC tap changer

Analog Voltage Combination Module

Thermistor motor protection relay CM-MSS.41

Thermistor motor protection relays CM-MSS.32 and CM-MSS.33

NI REM Remote I/O Overview DATASHEET. Analog Output Module for Remote I/O

Isolated Wideband Voltage Input 3B40 / 3B41 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

HITACHI. EH-150 series PLC EH-RTD8 Resistance Temperature Detective input module Instruction manual. Safety precautions

SP SP-T-9

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

SER-4485-SI-M USER S MANUAL

NI REM Remote I/O Overview DATASHEET. Digital Output Module for Remote I/O

Installing the Tracer MP503 Input/Output Module Ordering number: ,

INSTRUCTION MANUAL RA 19-6B RACK ADAPTER HOT SWAP RACK ADAPTER FOR HSF SERIES POWER SUPPLIES

16-Way Input 48-Way Output Card

Synchro-check relay. Application

Model 2600B-PM V Protection Module with 1 A Clamp. Description / April 2015 *PPA * 1

PSR-SCP- 24DC/URM4/4X1/2X2/B PSR-SPP- 24DC/URM4/4X1/2X2/B

DIN Rail. user manual Models , & INT /503556/ UM

D115 The Fast Optimal Servo Amplifier For Brush, Brushless, Voice Coil Servo Motors

CVU-200-KIT. 200 V Bias Tee Kit. Description. Parts list / October 2014 *P A* 1

GETTING STARTED GUIDE NI Channel, 50 Arms Continuous, 24-Bit, Analog Input Module

Model 8020-KHV. Kelvin Keithley Triaxial Connector Card. Description / October 2014 *P * 1

Circuit Breaker Sentinel (CBS) for SF 6. power circuit breakers

ITEM ESM-BA301

4100/4120-Series and 4010ES Relay Modules Installation Instructions

2260B-RMK-Series Rack Mount Kit

TM3TM3 module TM3-2 temperature inputs and 1 analog output

Isolated Linearized RTD Input 5B34 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Model 2380 Rack-Mount Kit

Isolated Voltage Input 3B30 / 3B31 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Mini Digital Multimeter

CONTROL MICROSYSTEMS Analog Output Module. Hardware Manual

CVU-3K-KIT. 3 kv Bias Tee Kit. Description. Parts list / October 2014 *P * 1

ControlWave Micro Digital Input / Output Modules

SEL-734B Data Sheet. Advanced Monitoring and Control System. Major Features and Benefits

Installation Guide. RuggedCom Inc. 300 Applewood Crescent Concord, Ontario Canada L4K 5C7

MMLG 01, 02, 03, 04 MMLB01

9926 Series Branch Rated Circuit Breakers AC Version

Transcription:

PROTECTION Universal Contact Input Adapter M 908 Converts seven internally wetted contacts to be compatible with Beckwith MXX protective relays and M Motor Bus Transfer System contact inputs Operates with V to 0 V dc wetting voltages Provides two input terminals per contact input Input to Output is optically isolated Industry Leader Since 99 Made in the USA

M 908 Universal Contact Input Adapter Specification Description The M908 Universal Contact Input Adapter will convert seven internally wetted status inputs of Beckwith relays to be externally wetted. The input voltage is selectable: 0 V dc, V dc, 8 V dc, V dc or V dc. This selection is made through a series of jumpers (Table ) on the printed circuit board. Each of the externally wetted inputs will be isolated from all other externally wetted inputs. Input to Output is optically isolated. n = JUMPER NUMBER NOMAL VOLTAGE JnA JnB JnC JnD V dc V dc 8 V dc V dc 0 V dc Table Input Voltage Jumper Configuration Terminal blocks are used for all connections to the device which includes two independent terminals per input circuit. The device will be panelmounted. There is an inherent ms delay from input to output operating time. Physical Size: 8." wide X.0" high X.0" deep (.cm X.cm X.8cm) Approximate Weight: lbs.,. oz (.9 kg) 0.8 [0.9] 0.0 [.].90 [.].90 [.8] 0.0 [.].0

M 908 Universal Contact Input Adapter Specification Atmospheric Environment Temperature IEC 008 Cold, 0 C IEC 008 Dry Heat, 0 C IEC 0088 Damp Heat, 0 C @ 9% RH Dielectric Withstand IEC 0 00 V dc for minute applied between each independent circuit and earth 00 V dc for minute applied between each independent circuit Insulation Resistance IEC 0 >00 Megaohms Surge Withstand Capability ANSI/IEEE 00 V pk oscillatory applied to each independent circuit to earth C.90.989 00 V pk oscillatory applied between each independent circuit 000 V pk fast transient applied to each independent circuit to earth 000 V pk fast transient applied between each independent circuit Warranty The M 908 Universal Contact Input Adapter is covered by a five year warranty from date of shipment. Specification subject to change without notice.

M 908 Universal Contact Input Adapter Specification V dc (9 to 0 V dc) Externally Wetted Contacts NOTE: Add a ground wire at the mounting plate and connect it to the cubicle chassis ground bar. TB TB 0 9 8 M908 TO RELAY 8 p CAUTION: To reduce noise susceptibility twisted, shielded cable (shield grounded on one end only) should be used on the Low Voltage outputs at TB. The remote contacts should be independently hispeed fused at low amperage. Do not bundle low voltage conductors with PT, CT and V dc cables. Internally Wetted Contact Inputs ( V dc) Beckwith Electric Relay NOTE: Two M908 adapters can be used with the M, M, MA, or MA with Expanded I/O. Figure Typical Application with Common Wetting Voltage Example

M 908 Universal Contact Input Adapter Specification V dc (9 to 0 V dc) All inputs may originate from independent sources of different voltages Externally Wetted Contacts May be a mix of NO and NC contacts NOTE: Add a ground wire at the mounting plate and connect it to the cubicle chassis ground bar. TB 0 9 8 M908 UNIVERSAL CONTACT PUT ADAPTER TO RELAY TB 8 p CAUTION: To reduce noise susceptibility twisted, shielded cable (shield grounded on one end only) should be used on the Low Voltage outputs at TB. The remote contacts should be independently hispeed fused at low amperage. Do not bundle low voltage conductors with PT, CT and V dc cables. Internally Wetted Contact Inputs ( V dc) Beckwith Electric Relay NOTE: Two M908 adapters can be used with the M, M, MA, or MA with Expanded I/O. Figure Application Example with Multiple Wetting Voltages

M 908 Universal Contact Input Adapter Specification EXTERNAL TRANSFER ITIATE PUTS V dc (9 to 0 V dc) All inputs may originate from independent sources of different voltages Externally Wetted Contacts b aux contact Externally Wetted Contacts Protection Relays Trip Contact b aux contact b aux contact Protection Relays Trip Contact b aux contact NOTE: Add a ground wire at the mounting plate and connect it to the cubicle chassis ground bar. TB 0 9 8 M908 UNIVERSAL CONTACT PUT ADAPTER TB TO RELAY 8 p CAUTION: To reduce noise susceptibility twisted, shielded cable (shield grounded on one end only) should be used on the Low Voltage outputs at TB. The remote contacts should be independently hispeed fused at low amperage. Do not bundle low voltage conductors with PT, CT and V dc cables. Internally Wetted Contact Inputs ( V dc) Beckwith Electric Motor Bus Transfer System Figure Application Specific to a BiDirectional Automatic Transfer

M 908 Universal Contact Input Adapter Specification TRADEMARKS All brand or product names referenced in this document may be trademarks or registered trademarks of their respective holders. Specification subject to change without notice. Beckwith Electric Co., Inc. has approved only the English version of this document.

BECKWITH ELECTRIC CO., C. 90 8th Avenue North Largo, Florida U.S.A. PHONE () FAX () 0 marketing@beckwithelectric.com www.beckwithelectric.com ISO 900:0 00 Beckwith Electric Co. All Rights Reserved. Printed in USA 800908SP08 08/8