ABB i-bus KNX AC/S Application Controller

Similar documents
ABB i-bus KNX Logic Controller ABA/S 1.2.1, 2CDG110192R0011

ABB i-bus KNX HCC/S Heating/cooling circuit controller

ABB i-bus KNX BCI/S Boiler/Chiller Interface

ABB i-bus KNX IP Router, MDRC IPR/S 3.1.1, 2CDG110175R0011

ABB i-bus KNX Analogue Actuator, 4-fold, MDRC, 0-10 V, 0-20 ma AA/S 4.1.2, 2CDG110202R0011

ABB i-bus KNX Analogue Input, 4-fold, MDRC AE/S , 2CDG110190R0011

ABB i-bus KNX Switch Actuator, x-fold, 10 A, MDRC SA/S x , 2CDG11015xR0011

ABB i-bus KNX Weather Unit, 1-fold, MDRC WZ/S , 2CDG110184R0011

ABB i-bus KNX Switch Actuator, Current Detection, x-fold, 16/20 A, C-Load, MDRC SA/S x , 2CDG1101xxR0011

ABB i-bus KNX DALI Light Controller, 8-fold, MDRC DLR/S M, 2CDG110101R0011

ABB i-bus KNX Fan Coil Actuator, PWM, MDRC FCA/S , 2CDG110195R0011

PRODUCT MANUAL. ABB i-bus KNX SV/S KNX-Power Supplies

ABB i-bus KNX Switch Actuator, x-fold, 16 A, MDRC SA/S x , 2TAZ710xx1R2161

ABB i-bus KNX KNX/EnOcean Gateway EG/A , 2CDG R0011

ABB i-bus KNX Switch Actuator, x-fold, 6 A, MDRC SA/S x.6.1.1, 2CDG x R0011

ABB i-bus KNX Thermoelectric Valve Drive, 230 V TSA/K 230.2, 2CDG R0011

ABB i-bus KNX Fan Coil Actuators FCA/S Product Manual

Device technology. Supply Bus voltage V DC. Current consumption via bus. Accuracy in the range 300 1,000 ppm 1,000 2,000 ppm 2,000 5,000 ppm

Linienkoppler S KNX. Line coupler S KNX. Line coupler S KNX Status: March 16 (Subject to change) Page 1 of 29

ABB i-bus KNX Fan Coil Actuators FCA/S Product Manual

Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG R0011

ABB i-bus KNX SUG/U 1.1 Split Unit Gateway Product Manual

ABB i-bus KNX Binary Inputs BE/S Product Manual

ABB i-bus KNX Blind/Roller Shutter Actuators JRA/S Product Manual

ABB i-bus KNX Blind/Roller Shutter Actuator JRA/S Product Manual

Application Controller AC/S

Electronic timer CT-EBD.12 Flasher starting with ON with 1 c/o (SPDT) contact

Product and Application Description

Electronic timer CT-SDD.22 Star-delta change-over with 2 n/o contacts

TEPI11 P/I signal converter

Electronic timer CT-SDS.23 Star-delta change-over with 2 n/o contacts

ABB GPG Building Automation, November 2016 ABB i-bus KNX Logic Controller ABA/S ABB Group November 10, 2016 Slide 1

Boxed interface relays and optocouplers R600 Boxed slim relays, optocouplers and accessories

Electronic timer CT-ARE OFF-delayed without auxiliary voltage, 1 c/o (SPDT) contact

Intrusion Detection Technology SafeKey Switching Module SSM/A, SSM/U Product Manual

ABB i-bus KNX Blower Actuator FCL/S x Product Manual

Voltage monitoring relays CM-ESS.1 For single-phase AC/DC voltages

Pluggable interface relays CR-P Pcb relays

Electronic timer CT-ERS.12 ON-delayed with 1 c/o (SPDT) contact

Bus Connection Unit 560BCU04

Switching relay CT-IRE with 1 c/o (SPDT) contact

Accessories for pluggable interface relays CR-P, CR-M Pluggable function module

Webinar Energy Analyzer QA/S 3.x.1

Operating voltage Maximum

Thermistor motor protection relays CM-MSS.12 and CM-MSS.13

Pluggable interface relays and optocouplers CR-P Pcb relays, optocouplers and accessories

Electronic timer CT-ARS.11 OFF-delayed without auxiliary voltage with 1 c/o (SPDT) contact

Accessories for pluggable interface relays CR-U Pluggable function modules

IP gateway, MDRC IG/S 1.1, GH Q R0001

KNX USB INTERFACE UIMtp

ABB i-bus KNX Application Unit Time ABZ/S 2.1 Product Manual

Messaging module CP-C MM

Operating and mounting instructions

Pluggable interface relays CR-M Miniature relays

Electronic timer CT-ARS.21 OFF-delayed without auxiliary voltage with 2 c/o (SPDT) contacts

Electronic timer CT-APS.21 OFF-delayed with 2 c/o (SPDT) contacts

Product and Applications Description

ABB i-bus KNX Blower/Fan Coil-Actuator LFA/S 1.1, LFA/S 2.1. Product Manual. Intelligent Installation Systems ABB

Accessories for pluggable interface relays CR-P Sockets

Thermistor motor protection relay CM-MSS.11

ABB i-bus EIB / KNX Blower/Fan Coil-Aktuator LFA/S 1.1, LFA/S 2.1. Product Manual. Intelligent Installation Systems ABB

Redundancy unit CP-A RU

Thermistor motor protection relays CM-MSS.22 and CM-MSS.23

Line Coupler, MDRC LK/S 3.1, GH Q R0001

Datasheet RCUXXYY EAE KNX Room Control Unit RCUXXYY DT R1.0. General Description. EAE Technology Page 1/10

Power supply CP-D 12/2.1 Primary switch mode power supply

Part No. Description Product Life Cycle Phase *) unit, 24 VDC, spring terminals. unit, 24 VDC, spring terminals, XC version

Article No. 6GK59230PS003AA2 6GK59240PS001AA2 Product Name. Power Supply SCALANCE PS924 PoE Input: 120/230V AC; Output: 54V/ 1.

Thermistor motor protection relays CM-MSS.32 and CM-MSS.33

ABB i-bus KNX DALI Gateway Emergency Lighting DGN/S Product Manual

PRODUCT MANUAL. ABB i-bus KNX DG/S x DALI-Gateway Basic

ENGLISH KNXCONVERTER PARLEZ VOUS ASCII?

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

Product and functional description

RTU500 series Data Sheet Power Supply CP-E 24/2.5

Digital Indicator DS 48/24 E

BACnet/IP Web Interface

Power supply CP-E 48/1.25 Primary switch mode power supply

Electronic timer CT-AHS OFF-delayed with 2 c/o contacts Data sheet

QUINT-DC-UPS/24DC/10. Extract from the online catalog. Order No.:

AI561 Analog Input Module

QUINT-DC-UPS/24DC/40. Extract from the online catalog. Order No.:

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

DI572 Digital Input Module

Electronic timer CT-ARS.21 OFF-delayed without auxiliary voltage with 2 c/o (SPDT) contacts

Thermistor motor protection relay CM-MSS.31

IntesisBox KNX - BACnet/IP Client

Power supply CP-E 24/0.75 Primary switch mode power supply

Electronic timer CT-ERD ON-delayed with 1 c/o contact Data sheet

Thermistor motor protection relay CM-MSS.41

DI561 Digital Input Module

Electronic timer CT-AWS Impulse-OFF with 2 c/o contacts Data sheet

TF501, TF521 Terminal Bases

Electronic timer CT-ERS.12 ON-delayed with 1 c/o contact Data sheet

TU531, TU532 Terminal Unit

The new Arc Fault Detection Device S-ARC1 Maximum safety easy installation

Electronic timer CT-VWD Impulse-ON with 1 c/o contact Data sheet

Product and functional description

Product and functional description. Application Program. instabus EIB Technical product information. April (6 x AC 230 V / 0,05 A)

Switching Actuators N530, 6AX Switching Actuators N532, 10AX Switching Actuators N534, 16/20AX

Transcription:

ABB i-bus KNX AC/S 1.2.1 Application Controller Description of product Automation controller with pre-defined automation modules for comprehensive heating, ventilation and air conditioning automation (HVAC automation). For use from central systems to room automation, supports the achievement of energy efficiency goals such as EN 15232. The device has a web user interface for the display of data and operation, this interface is generated automatically, as well as an integrated BACnet/IP gateway for the connection of the KNX system to the building control system and other higher level BACnet systems for the bidirectional exchange of data between KNX and BACnet. The device contains pre-defined application-specific automation modules (ASM) for the most common areas of application, for instance the calculation of heat demand, trends or schedulers. You can create your own automation modules using a graphic logic editor. Commissioning is undertaken entirely in ETS version 5.6.5 or later. Additional external software is not required. The device has a KNX TP connection and requires a supply voltage of 24 V AC/DC or PoE for operation.

Dimension drawing 2CDC072033F0015 2 2CDC508242D0211 Rev. A AC/S 1.2.1

Connection 1. Dismount 2. LAN (PoE) ON LAN / LINK KNX Telegram Us Us = 24 V AC/DC 1 2 24 V AC/DC 2CDC072062F0017 LEGEND 1Label carrier 2KNX programming LED (red) 3KNX programming button 4KNX connection 5Cover cap 6Power supply connection U s 7Ethernet/LAN connection 8On LED (green) 9LAN/LINK LED (yellow) 10 KNX telegram LED (yellow) 11 Reset/factory settings button (behind label carrier) AC/S 1.2.1 2CDC508242D0211 Rev. A 3

Operating and display elements Button/LED Description LED indicator Assignment of the physical address On: Device is in programming mode ON LAN/LINK Telegram Reset (behind label carrier) Off: No auxiliary voltage (24 V or PoE) available On: System initialized Flashing slowly (1 Hz): System starting up Flashing quickly (4 Hz): Error On: Auxiliary voltage and Ethernet connection available Flickering: Data traffic via LAN On: Auxiliary voltage and KNX connection available Flickering: Data traffic via KNX/TP Press for less than 2 seconds: no reaction. Press for 2 to 10 seconds: device restart. Retains configuration and last states. Press for more than 10 seconds: factory reset. Deletes configuration and all states. NOTE Device restart and factory reset are only possible when bus voltage and auxiliary voltage are applied. NOTE A firmware update cannot be undone after a factory reset. 4 2CDC508242D0211 Rev. A AC/S 1.2.1

Technical data Supply Bus voltage 21 32 V DC Current consumption, bus Leakage loss, bus Leakage loss, device Auxiliary voltage U S Auxiliary voltage current consumption KNX connection KNX current consumption < 12 ma Maximum 250 mw Maximum 3 W 24 V AC/DC (+20 % / -15 %) or PoE (IEEE 802.3af class 2) 90 ma typical, 120 ma peak current 0.25 W < 10 ma Connections KNX Via bus connection terminal Auxiliary voltage LAN Via screw terminals 0.2 2.5 mm² stranded 0.2 4 mm² solid Protection degree IP 20 To EN 60529 Protection class II To EN 61140 Isolation category Overvoltage category III to EN 60664-1 Pollution degree II to EN 60664-1 SELV KNX safety extra low voltage SELV 30 V DC Temperature range Operation - 5 +45 C Transport -25 +70 C Storage -25 +55 C RJ45 socket for 10/100BaseT, IEEE 802.3 networks, AutoSensing Ambient conditions Maximum air humidity 93 %, no condensation allowed Atmospheric pressure Atmosphere up to 2,000 m Design Modular installation device (MDRC) Modular installation device Design Housing/color pro M Plastic, halogen free, gray Dimensions Dimensions 90 x 70 x 64 mm (H x W x D) Mounting width in space units Mounting depth 4x 17.5 mm modules 68 mm Mounting 35 mm mounting rail To EN 60715 Mounting Position Weight Fire classification Any 0.192 kg Flammability V-0 as per UL94 Approvals KNX certification To EN 50090-1, -2 CE conformity Certification To EN 60669 In accordance with the EMC directive and low voltage directive AC/S 1.2.1 2CDC508242D0211 Rev. A 5

Software Device type Application Controller AC/S 1.2.1 Application Maximum number of KNX group objects Maximum number of KNX group address assignments HVAC application/ * 2000 16000 Maximum number of BACnet objects 500 Maximum number of BACnet COV subscriptions Maximum number of application-specific automation modules (ASM) 2500 500 Of which schedulers 15 Of which central HVAC 15 Maximum number of trends Automation ASM Maximum number of logic elements 1000 Maximum number of sockets 200 Maximum number of web user interface I/O Maximum number of web user interface accesses 50 values for up to 3 years * = Current version number of the application. Please refer to the software information on our website for this purpose. 30 5 Ordering details Device type Product Name Order No. bbn 40 16779 EAN Weight 1 pcs. [kg] AC/S 1.2.1 Application Controller, BACnet 2CDG110206R0011 0.192 1 Packaging [pcs.] 6 2CDC508242D0211 Rev. A AC/S 1.2.1

NOTE Please refer to the AC/S 1.x.1 Application Controller product manual for a detailed description of the application. It is available free of charge at www.abb.com/knx. ETS and the current version of the device application are required for programming. The latest version of the application and corresponding software information is available for download from www.abb.com/knx. After import into ETS, it appears in the Catalogs window under Manufacturers/ ABB/Heating, air conditioning, ventilation/automation controller. In addition to the ETS application, you will require ETS DCA ABB AC/S for commissioning; this can be obtained free of charge from the KNX online shop. The device does not support the locking function of a KNX device in ETS. Using a BCU code to inhibit access to all the project devices has no effect on this device. Data can still be read and programmed. NOTE The application HVAC Application/1.0 and the DCA ABB AC/S are supported in ETS 5 only from version 5.6.5. Earlier versions are not supported. AC/S 1.2.1 2CDC508242D0211 Rev. A 7

ABB STOTZ-KONTAKT GmbH Eppelheimer Straße 82 69123 Heidelberg, Germany Telefon: +49 (0)6221 701 607 Telefax: +49 (0)6221 701 724 E-Mail: knx.marketing@de.abb.com Further Information and Local Contacts: www.abb.com/knx Copyright 2018 ABB. We reserve the right to make technical changes or modify the contents of this document without prior notice. With regard to purchase orders, the agreed particulars shall prevail. ABB AG does not accept any responsibility whatsoever for potential errors or possible lack of information in this document. We reserve all rights in this document and in the subject matter and illustrations contained therein. Any reproduction, disclosure to third parties or utilization of this contents - in whole or in parts - is forbidden without prior written consent of ABB AG. Order Number 2CDC508242D0211 Rev. A (08.2018)