IO-INTERFACE. Procon. INSTALLATION MANUAL Version 1.01 MITSUBISHI ELECTRIC FOR INSTALLERS

Similar documents
Procon A1M. INSTALLATION MANUAL Version MITSUBISHI ELECTRIC FOR INSTALLERS

Procon MelcoRETAIL MINI

RTD-RA. realtime. Installation Instructions. English A B. Installation Instructions Control Systems LEDS ALL DIMENSIONS IN MM

Installation, Start-up and Operating Instructions

MM-A20 BMS Interface for Mitsubishi Electric Split Air-Conditioning

Obtaining Documentation and Submitting a Service Request, page xvii Safety Warnings, page xvii Safety Guidelines, page xx

PAR-WT50R-E PAR-WR51R-E

Model HM-535 Power Supply Installation and Service Instructions

Modbus Interface Module

intelligent Touch Controller Web Software

FCU-4 FAN COIL CONTROLLER

The power behind competitiveness. Delta Infrasuite Power Management. Power Distribution Unit. User Manual.

Power supply unit Model: PAC-SC51KUA

RТTH DUAL ROOM SWITCH

Dip Switch settings.

Instruction Book. English. CITY MULTI Control System and Mitsubishi Mr. Slim Air Conditioners MA Remote Controller PAR-31MAA

Room Temperature Controller

BW-108. Building Wash BW-108. User Guide. Advanced LED Technology

Flexoled FTP3HP RGB LED DMX Driver

Installation Manual RB-RWS20-E. Lite-Vision plus Remote Controller. Model name: English

D610H, D610H MKII, D610S, D610T dimmer pack. user manual

RTT2 ROOM TEMPERATURE SWITCH. Mounting and operating instructions

ZWS12n AUS chain actuator user manual (Motor Class C)

RTD-NET Installation Instructions

Field module for cold locations for installation in refrigerators for direct control of a pulsed expansion valve

D1210H dimmer pack. user manual

LED FOLDING WORKLIGHT TM

COMFORT CONTROL CENTER SERVICE INSTRUCTIONS

CMSA-100 Manual. Cinema Media Server Automation

Manual Simatek Control Unit GFC 32

Installation Instructions

BLUETOOTH DIMMING CONTROLLER

RXTP ROOM TEMPERATURE

HITACHI. EH-150 series PLC EH-RTD8 Resistance Temperature Detective input module Instruction manual. Safety precautions

QUICK START GUIDE. vau4/3. Frequency converter. operating instructions /12

RTD-W Installation Instructions

MODEL SST3-MV INSTALLATION INSTRUCTIONS FOR FEDERAL MODEL SST3-MV SELECTABLE SIRENTONE-MULTI VOLT

D-Pack 6 Classic ORDERCODE 50315

Mitsubishi Electric Air-conditioner Network System

INSTALLATION INSTRUCTIONS

Failure to follow WARNING is very likely to result in such grave consequences as death or serious injury

Manual Control Unit GFC 32

MC 11 EB-2 Power supply cabinet with external bus, AC version

Communicative controller for VAV systems

LEGA ENERGY ELECTRONIC RELAY VOLTAGE STABILIZER VA USER MANUAL

Modified Sinewave Series. Power Inverter 1000/1500 MW 1210, MW1215. True Sinewave Power Inverter 1000/2000 SW 1210, SW 1220.

CoolPlug CooLinkHub HVAC Bridge. Quick Installation Guide

DPX-620III 6-Ch. dimmer pack. user manual

WavePRO Wireless Programmable T2500 Thermostat & R2500 Receiver OPERATING MANUAL. Model K

Room Temperature Controller

RXTH DUAL ROOM SENSOR / SWITCH

Users Manual STP-103II. Thermal Printer Rev

EC Series. Safety Guide

Nature Power Inverters. Modified Sinewave 1000w/1500w True Sinewave 1000w/2000w. Owner s Manual

Service Bulletin SB685. Date: 8/18/2017 TriPac EVOLUTION Communications Update Bulletin Location: TSA Info Central\Service Bulletins

FTP1 Single Channel LED DMX Driver

Blitzer RGB Strobe. User Manual. Order code: EQLED365

Octostrip ORDERCODE 42220

FIBARO SINGLE SWITCH

HX1 Bluetooth Stereo Headset

CoolPlug CooLinkHub HVAC Bridge. Quick Installation Guide

Operation Instruction for CNI Model with PSU-III-LCD

INSTALLATION INSTRUCTIONS

LED Colour Flood 10W / 30W RGB LED floodlight. user manual

4P M. Wireless LAN Connecting Adapter <BRP069A45> Installation Manual

Polymer Electric. Operating Instructions. Control Unit SG-EFS 1X4 ZK2/1 8k2. Version 3

OPERATING INSTRUCTIONS PA AMPLIFIER P-1812

Gobo Projector XP 80W

4P Wireless LAN Connecting Adapter <BRP069B41> <BRP069B42> <BRP069B43> <BRP069B44> <BRP069B45> Installation Manual

MXM-50. Modbus Interface for Mitsubishi Air-Conditioning. Installation and User Guide.

RGB Power Batten. User Manual. Order code: EQLED032

SOLARIMMERSION IV Advanced Installation Manual v1.9

OPERATING INSTRUCTIONS 7 SERIES STATIC GENERATORS

4P S. Wireless LAN Connecting Adapter <BRP069A42> Installation Manual

4P S. Wireless LAN Connecting Adapter <BRP069A41> Installation Manual

Safety Instructions 1-1 Avoid unintended Start General Description 2-2

Temperature controller Ducted systems

CS2 DMX Distribution Splitter

Instruction Book. English. CITY MULTI Control System and Mitsubishi Mr. Slim Air Conditioners MA Remote Controller PAR-30MAA

4P R. Wireless LAN Connecting Adapter <BRP069A81> Installation Manual

DS-1H05 Ethernet-over-Coax Extender. User Manual

DALI Professional Controller-4. Control unit Operating instructions

Magnum Club Smoke System

Achat 110 MA active full-range speaker. user manual

User Manual. MULTI Touch Series 78 / 89

Installation and Operation Back-UPS BR1000G-IN / BR1500G-IN

Installing and Configuring Rialto Analytic Appliances

BS 287 DUAL CHANNEL POWER SUPPLY. User Manual. January 2017 V1.0

LEDJ Tri LED DJ Skirt Matrix Cloth - STAR17 USER MANUAL

Wa r n i n g-wa r n i n g-wa r n i n g

1:1 Model Connection Interface

InnoMedia Business VoIP ATA Models

TA18 active subwoofer. user manual

72In LED Lit Nutcracker Item # CAUTION: IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL SAFETY INSTRUCTIONS

Blitzer Strobe. User Manual. Order code: EQLED366

True Sinewave Power Inverter 1000W & 2000W 230V , Owner s Manual

PRODUCT MANUAL SMOKE-1500 ENGLISH. Version: 1.0

MOBILE CONNECTOR - GEN 2 OWNER'S MANUAL

ETM-2040 Service Manual

Achat 112 MA Achat 112 MA WH full-range speaker. user manual

Transcription:

Procon IO-INTERFACE FOR INSTALLERS INSTALLATION MANUAL Version 1.01 For safe and correct use, please read this installation manual thoroughly before installing the PROCON IO-INTERFACE. MITSUBISHI ELECTRIC

Page 2 of 24

Contents 1. Safety Precautions... 8 2. Product Overview... 9 2.1. Basic Features... 9 2.2. Extended features... 9 2.3. Advanced Energy Save Features... 9 2.4. Relay Output... 9 3. Supplied Wiring Looms... 10 4. Size and weight... 10 5. Electrical wiring and installation... 11 5.1. Precautions on electrical wiring... 11 5.2. Wiring Connections:... 11 5.3. External Connections... 12 5.3.1. Digital inputs... 12 5.3.2. Analogue Inputs... 12 5.3.3. Relay outputs... 12 6. Description of Features... 13 6.1. Basic Parameter Control... 13 6.2. The Lock Input... 13 6.3. Energy Save Modes... 13 6.3.1. Auto/Fan... 13 6.3.2. Dead Band Mode... 14 6.4. Relay Outputs... 15 6.4.1. On/Off... 15 6.4.2. Fault... 15 6.4.3. Thermo... 15 6.5. Mode Monitor... 15 7. LED Indications on the Unit... 16 8. Applicable Air Conditioning Models... 17 8.1. Using twin / triple / quad systems... 17 8.1.1. When using Fault output... 17 8.1.2. When not using Fault output... 17 8.2. Using single splits in a group... 18 8.2.1. When using Fault output... 18 8.2.2. When not using Fault output... 18 8.3. Using MXZ splits... 19 9. Important Notes... 20 10. Additional Information... 21 10.1. Appendix A: Analogue Input Ranges... 21 10.1.1. Setpoint:... 21 10.1.2. Mode:... 21 10.1.3. Fan Speed... 21 10.2. Appendix B: Dip Switches Settings... 21 10.2.1. SW1-1 to SW1-4 Lock Settings (When Lock Input is Activated)... 21 10.2.2. SW2-1 to SW2-5 Energy Save Settings - Auto/Fan Algorithm... 22 10.2.3. SW2-1 to SW2-5 Energy Save Settings - Deadband Algorithm... 22 10.2.4. SW2-5 Reset settings when energy save deadband mode is not required... 23 10.2.5. SW2-6 Heating / Cooling Output... 23 10.3. Revision History:... 23 Page 3 of 24

1 [Fig. 1] Included Items A A B 1 x Procon IO-Interface 1 x Manual B Page 4 of 24

2 [Fig. 2] Inside of Units A B C D E Digital Inputs Analogue Inputs Dip Switch Digital Outputs Status LEDs E A D B C Page 5 of 24

3 [Fig. 3] Wiring Diagram On/Off Lock Energy Save External Fault Run Faults Thermo Heat/Cool Setpoint Mode Fan Speed CN105 or CN92 INDOOR UNIT PCB Page 6 of 24

Quick set up Step 1: Unpack the Procon IO-Interface and secure it in place. Step 2: Set the dip switches on the Procon IO-Interface depending of the requirements. Step 3: Connect inputs and outputs depending of the requirements. Step 4: Connect the Procon IO-Interface to the CN105 terminal on the indoor unit. Step 5: Check that the power LED is flashing for some time (start up time) and then becomes solid. The comms LED will then start flashing. Step 6: Check the output LED matches the indoor unit settings (On/Off, Heat/Cool ). Important note: When using energy save features, it is important to use a remote sensor (PAC-SE41TS) or the remote controller sensor to accurately read the room temperature. Page 7 of 24

1. Safety Precautions Before installing the unit, make sure you read all the Safety precautions The Safety precautions provide very important points regarding safety. Make sure you follow them Symbols used in the text Warning: Describes precautions that should be observed to prevent danger of injury or death to the user. Caution: Describes precautions that should be observed to prevent damage to the unit. Warning: Carefully read the labels affixed to the main unit Warning: Ask the dealer or an authorised technician to install the unit - Improper installation by the user may result in water leakage, electric shock, or fire Use the specified cables for wiring. Make the connections securely so that any outside forces acting on the cables are not applied to the terminals - Inadequate connection and fastening may generate heat and cause a fire Never repair the unit. If the controller must be repaired, consult the dealer - If the unit is repaired improperly, electric shock, or fire may result When handling this product, always wear protective equipment. EG: Gloves, full arm protection and safety glasses - Improper handling may result in injury Have all electric work done by a licensed electrician according to "Electric Facility Engineering Standard", "Interior Wire Regulations" and the instructions given in this manual and always use a special circuit - If the power source capacity is inadequate or electric work is performed improperly, electric shock and fire may result Keep the electric parts away from any water - washing water etc - Contact may result in electric shock, fire or smoke Do not reconstruct or change the settings of the protection devices - If the protection device is shorted or operated forcibly, or parts other than those specified by Mitsubishi Electric are used, fire or explosion may result To dispose of this product, consult your dealer Caution: Safely dispose of the packing materials - Packing materials, such as nails and other metal or wooden parts, may cause stabs or other injuries - Tear apart and throw away plastic packaging bags so that children will not play with them - If children play with a plastic bag which has not been torn apart, they face the risk of suffocation Page 8 of 24

2. Product Overview The Procon IO-Interface unit is a versatile interface module for use on equipment fitted with either a CN105 or CN92 terminal. The unit features Digital-Analogue Input / Digital Output and can provide a wide range of control features with bit switch selection as detailed below: 2.1. Basic Features Parameter control using digital and analogue inputs for: - On/Off - Setpoint - Mode - Fan Speed State monitoring via relay outputs of: - On/Off - Error 2.2. Extended features Ability to lock the parameters in 2.1 against alteration by the remote controller. External error input to allow monitoring of the error state of associated air conditioners. 2.3. Advanced Energy Save Features Two selectable energy saving algorithms. - Timed Auto / Fan - Deadband Mode 2.4. Relay Output Two relay outputs to allow control of external equipment based on the control status of the unit. - Thermo output which is active when the unit is not at setpoint and is working to achieve setpoint. - Active operational mode (selectable as Heating or Cooling) Page 9 of 24

3. Supplied Wiring Looms The unit is provided with a 1.5 meter five wire connection loom to connect from the IO-Interface to CN105 or CN92 on the associated air conditioner. The loom is already internally connected to the IO-INTERFACE and has a plug on the free end. 4. Size and weight The Procon IO-Interface details are: - Height 138 mm - Width 85 mm - Depth 32 mm - Weight 0.37kg Page 10 of 24

5. Electrical wiring and installation 5.1. Precautions on electrical wiring Warning: Electrical work should be done by qualified electrical engineers / electrician in accordance with "Engineering Standards for Electrical Installation" and supplied installation manuals. Dedicated circuits should also be used. If the power circuit lacks capacity or has an installation failure, it may cause a risk of electric shock or fire. 5.2. Wiring Connections: Wiring connections must be made before the unit is mounted. Disconnect all supplies to the air conditioner unit before installation. Digital Inputs Digital Outputs Analogue Inputs Flying Lead Fig 1 : Terminal Layout Connect the plug on the flying lead from the IO-INTERFACE to connector CN105 or CN92 on the associated air conditioner. Connect the analogue and digital inputs and outputs to the desired controlling equipment taking note of the required signal levels (See Appendix A). Page 11 of 24

5.3. External Connections 5.3.1. Digital inputs The four digital inputs are: - On - Lock - Energy Save - Remote Fault The four inputs are all activated by contact closure. The switching voltage is 5v DC at approx 1mA. 5.3.2. Analogue Inputs The three analogue inputs are: - Setpoint - Mode - Fan Speed Each operates over a range of 0-10v DC. For signal information see Appendix A. 5.3.3. Relay outputs The four relay outputs are: - On - Fault - Thermo - Active The contacts are normally open contacts with a switching capacity of 1A at 24v (AC or DC). Page 12 of 24

6. Description of Features 6.1. Basic Parameter Control The unit has a digital input for control of On/Off and three analogue inputs for control of Setpoint, Mode and Fan Speed. A change to any of these inputs will be transmitted to the air conditioner. The analogue inputs work in bands. For details of the required voltages see Appendix A. 6.2. The Lock Input Normally the parameters are only transmitted to the associated unit on change. If the Lock digital input is active then the parameter values will be transmitted approximately every 5 seconds thus overriding any changes which may have been made from other sources. It is possible to select which parameters are locked using bit switch SW1. Each of the 4 switches on this bank controls one of the parameters and if ON will result in that parameter being locked. For bit switch information see Appendix B. 6.3. Energy Save Modes When using energy save features, it is important to use a remote sensor (PAC-SE41TS) or the remote controller sensor to accurately read the room temperature. The unit offers two energy save modes: 6.3.1. Auto/Fan Auto/Fan is selected by setting bit switch SW2-1 to OFF and setting either or both of bit switches SW2-2 and SW2-3 ON. In this mode the unit will put the air conditioner into AUTO whenever a momentary signal is applied to the Energy Save input or whenever the on/off state is changed from OFF to ON. The unit will operate in AUTO for a fixed period set by bit switches SW2-2 and SW2-3 after which it will revert to the mode as requested on the mode analogue input (no connection to this input will give FAN). The AUTO period may be re-initialised at any time. For bit switch information see Appendix B. Page 13 of 24

The diagram below shows an example of the Auto/Fan function. 6.3.2. Dead Band Mode Dead Band mode is selected by setting bit switch SW2-1 to ON and activating the Energy Save input. In this mode the unit uses high and low setpoints to control the operation of the air conditioner. The selected parameter values for Setpoint and Mode are ignored by the system. Operation in Dead Band Mode Temperature rising: - When the room temperature is above the high setpoint then the unit will be placed in COOL mode with a local setpoint of 19 degrees - As the room temperature falls below [High Setpoint-1] degrees the air conditioner will switch to FAN mode Temperature falling: - When the room temperature is below the low setpoint then the unit will be placed in HEAT mode with a local setpoint of 28 degrees - As the room temperature rises above [Low Setpoint+1] degrees the air conditioner will switch to FAN mode. High and Low setpoints are set by bit switch SW2 as detailed in Appendix B. The diagram below shows an example of the dead band mode function. Page 14 of 24

6.4. Relay Outputs There are 4 relay outputs each of which has an associated LED 6.4.1. On/Off The relay and the LED both energise when the unit is ON and de-energise when it is off. The LED will flash when the unit is ON but in standby mode. 6.4.2. Fault The Relay and LED both energise when the unit is in a fault condition or the external fault input is active. 6.4.3. Thermo The relay and LED both energise when the unit is: - More than 1 degrees below the local setpoint in Heat or Auto modes - More than 1 degrees above the local setpoint in Cool or Auto modes 6.5. Mode Monitor The relay and LED energise in the selected mode (Heat or Cool). See Appendix B for mode selection. Page 15 of 24

7. LED Indications on the Unit LED1 is the top LED. The unit has 6 LEDs which are all visible through the case of the unit. Their functions are: - LED1: Power - Blue o During the establishing of communications this LED will flash approximately once per second. Once communication is established the LED will remain permanently ON - LED2 : Run Green o The Run LED will illuminate when the associated unit is ON. This LED flashing indicates a Standby or Fault condition - LED3 : Fault Red o The Fault LED will illuminate when the associated unit is in a fault condition or when the External Fault input is activated - LED4: Thermo Yellow o This LED will illuminate when the associated unit is in the Thermo state i.e. o More than 1 degrees below the local setpoint in Heat or Auto modes o More than 1 degrees above the local setpoint in Cool or Auto modes - LED5: Active State Yellow o This LED will illuminate when the associated unit is in the selected Active state (Heat or Cool as selected by bit switch) - LED 6: Comms Yellow o The Comms LED displays the communications activity and should be flashing approximately once per second Page 16 of 24

8. Applicable Air Conditioning Models Below is a list of Air Conditioning models that can be connected to this unit: - M series product range (includes MXZ) - Mr Slim product range (includes S series) * Please note that: - T he split units must have CN92 / CN105 connection. This connection is only on units produced on or after 2006 8.1. Using twin / triple / quad systems It is recommended to use one IO-Interface per indoor unit, however if the fault output is not used one IO-Interface can be used per twin / triple / quad system. 8.1.1. When using Fault output IO Interface IO Interface IO Interface Fault output Fault output Fault output 8.1.2. When not using Fault output IO Interface Page 17 of 24

8.2. Using single splits in a group It is recommended to use one IO-Interface per indoor unit, however if the fault output is not used one IO-Interface can be used per twin / triple / quad system. 8.2.1. When using Fault output IO Interface IO Interface Fault output Fault output 8.2.2. When not using Fault output IO Interface Page 18 of 24

8.3. Using MXZ splits One IO-Interface must be installed per indoor unit when using a MXZ system. IO Interface IO Interface IO Interface Page 19 of 24

9. Important Notes The cable used to connect the IO-Interface to the indoor unit cannot be extended as it is low voltage The split units must have CN92 / CN105 connection. This connection is only on units produced on or after 2006 When using energy save features, it is important to use a remote sensor (PAC-SE41TS) or the remote controller sensor to accurately read the room temperature Page 20 of 24

10. Additional Information 10.1. Appendix A: Analogue Input Ranges 10.1.1. Setpoint: Temp 17 18 19 20 21 22 23 24 25 26 27 28 29 30 Volts 1.0 1.5 2.0 3.0 3.5 4.0 4.5 5.5 6.0 6.5 7.0 8.0 8.5 9.0 Valid setpoint ranges are: AUTO HEAT COOL 19 to 28 degrees 17 to 28 degrees 19 to 30 degrees If the input is outside the valid range then the air conditioner will use the nearest available setpoint. 10.1.2. Mode: Mode FAN HEAT COOL AUTO Volts 0-2v 3-4.5 5.5-7 8-10 Available modes depend on the air conditioner model type. Invalid inputs will use the nearest available mode. 10.1.3. Fan Speed Speed Low Mid 1 Mid 2 High Volts 0-2 3 4.5 5.5 7 8-10 Available speeds depend on the air conditioner model type. Invalid inputs will use the nearest available speed. 10.2. Appendix B: Dip Switches Settings 10.2.1. SW1-1 to SW1-4 Lock Settings (When Lock Input is Activated) SW1-1 On/Off SW1-2 Setpoint SW1-3 Mode SW1-4 Fan Speed To activate the lock function, the ON input must be closed. Page 21 of 24

10.2.2. SW2-1 to SW2-5 Energy Save Settings - Auto/Fan Algorithm SW2-1 OFF: Auto/Fan Algorithm SW2-2 and SW2-3 OFF: SW2-2 ON, SW2-3 OFF: SW2-2 OFF, SW2-3 ON: SW2-2 ON, SW2-3 ON: Algorithm Inactive AUTO time = 0.5 Hrs AUTO time = 1.0 Hrs AUTO time = 2.0 Hrs Summary: SW2-1 OFF OFF OFF OFF SW2-2 OFF ON OFF ON SW2-3 OFF OFF ON ON SW2-4 - - - - SW2-5 - - - - Inactive 0.5h 1h 2h In this mode the unit will put the air conditioner into AUTO whenever a momentary signal is applied to the Energy Save input or whenever the on/off state is changed from OFF to ON. 10.2.3. SW2-1 to SW2-5 Energy Save Settings - Deadband Algorithm SW2-1 ON: Deadband Algorithm SW2-2 and SW2-3 control the LOW setpoint SW2-4 and SW2-5 control the HIGH setpoint Low setpoint: SW2-2 and SW3 both OFF = 18 C SW2-2 ON, SW2-3 OFF = 19 C SW2-2 OFF, SW2-3 ON = 20 C SW2-2 ON, SW2-3 ON = 21 C High setpoint: SW2-4 and SW-5 both OFF = 25 C SW2-4 ON, SW2-5 OFF = 24 C SW2-4 OFF, SW2-5 ON = 23 C SW2-4 ON, SW2-5 ON = 22 C If switches SW2-2, SW2-3, SW2-4 and SW2-5 are all ON this represents an invalid situation and the setpoints will be reset to 20 and 23 deg C. Summary: SW2-1 ON ON ON ON ON ON ON ON ON SW2-2 OFF ON OFF ON - - - - ON SW2-3 OFF OFF ON ON - - - - ON SW2-4 - - - - OFF ON OFF ON ON SW2-5 - - - - OFF OFF ON ON ON 18C 19C 20C 21C 25C 24C 23C 22C 20/23C To activate the Deadband energy save function, the Energy Save input must be closed. Page 22 of 24

10.2.4. SW2-4 and SW2-5 Reset settings when energy save deadband mode is not required To retain fan coil values through a power out set SW2-4 and SW2-5 both OFF. To re-load fan coil values from the IO_Interface inputs after a power out set SW2-4 ON and SW2-5 ON. This option is not available (or needed) when using Energy Save Deaband Mode. 10.2.5. SW2-6 Heating / Cooling Output SW2-6 OFF: The heating / cooling output relay and the LED5 will energise when the unit is in cooling mode or in auto cooling mode. SW2-6 ON: The heating / cooling output relay and the LED5 will energise when the unit is in heating mode or in auto heating mode. 10.3. Revision History: Ver 1.00 28 th May 2010 Final version Ver 1.01 14 th September 2010 Added 10.2.4 (SW2-4 and SW2-5 reset settings) Page 23 of 24

This product is designed and intended for use in the residential, commercial and lightindustrial environment. The product at hand is based on the following EU regulations: Low Voltage Directive 73/23/EEC Electromagnetic Compatibility Directive 89/336/EEC Please be sure to put the contact address/telephone number on this manual before handing it to the customer. MITSUBISHI ELECTRIC UK MITSUBISHI ELECTRIC UK, TRAVELLERS LANE, HATFIELD HERTFORDSHIRE, AL10 8XB Page 24 of 24