Product Overview CHAPTER

Similar documents
Fast Ethernet Port Adapter Family (PA-2FE) For Cisco 7200, 7300, 7500 and 7600 Series Routers

New Product: Cisco Catalyst 2950 Series Fast Ethernet Desktop Switches

Overview of the Cisco 2524 and Cisco 2525 Routers

Installation Preparation

MCF2xxx SERIES Multi-channel Modular Media Chassis

Overview. Features CHAPTER

4 PWR XL: Catalyst 3524 PWR XL Stackable 10/100 Ethernet

GigaVUE-2404 // Data Sheet

LRS-12. "Last Mile" SNMP Modem Rack FEATURES

BLACKBOX NETWORK SERVICES. one source for worldwide infrastructure services

Korenix JetNet 3000 Series Industrial Entry-Level Ethernet Rail Switch User s Manual

Cisco SGE Port Gigabit Switch Cisco Small Business Managed Switches

ProCurve Switch 2500 Series

MS400870M. User's Guide. Ver.: Port GBE SFP Switch 19 1U 24x10/100/1000T Combo 10/1000X SFP

FDDI. L26 - Fibre Distributed Data Interface (FDDI) L26 - Fibre Distributed Data Interface (FDDI) FDDI - Fiber Distributed Data Interface

6GK6021-0MS Automation Technology > Industrial Communication > Industrial Ethernet > RUGGEDCOM Ethernet Switches > RUGGEDCOM RSG2000 managed

GSW-2453 Gigabit Chassis switch. User Guide

Cisco SFE Port 10/100 Ethernet Switch Cisco Small Business Managed Switches

A.1 Cisco ONS CL Shelf Specifications. This section includes hardware and software specifications.

GigaVUE-420 Specifications

Chassis-based Media Converters

6GK6041-6AT Automation Technology > Industrial Communication > Industrial Ethernet > RUGGEDCOM Serial Device Servers > RUGGEDCOM RS416 managed

6GK6023-0AS Automation Technology > Industrial Communication > Industrial Ethernet > RUGGEDCOM Ethernet Switches > RUGGEDCOM RSG2000 managed

6GK6091-0AT Automation Technology > Industrial Communication > Industrial Ethernet > RUGGEDCOM Serial Device Servers > RUGGEDCOM RS910 managed

6GK6021-0PS Automation Technology > Industrial Communication > Industrial Ethernet > RUGGEDCOM Ethernet Switches > RUGGEDCOM RSG2000 managed

FSM-510G Series Ethernet Management Switch Quick Start Guide

INDUSTRIAL POE SWITCH

Product Overview. Switch Features. Catalyst 4503 Switch Features CHAPTER

Modular E1 or Fractional E1 Access Unit. Dial-out for alarm report The E1 main link can be supplied with the following options:

FOMi-40 Fiber Optic Modem with Remote Management

Cisco SFE2000P 24-Port 10/100 Ethernet Switch: PoE Cisco Small Business Managed Switches

JG962A Datasheet. Overview. Quick Spec. Product Details

GigaVUE-420 // Data Sheet

OmniConverterTM. OmniConverter FPoE/SL, FPoE/S and FPoE+/S 10/100 Media Converter with Power over Ethernet (PoE or PoE+) KEY FEATURES

6GK6096-8MS Automation Technology > Industrial Communication > Industrial Ethernet > RUGGEDCOM Ethernet Switches > RUGGEDCOM RS900 managed

TE100-DX16R/DX24R/DX32R 16/24/32 Ports Ethernet/Fast Ethernet Dual-Speed Stackable Hubs User s Guide

10/100BASE-TX TO 100BASE-FX MEDIA CONVERTERS EM4000 EM4001. Installation Guide

6GK6096-8AS Automation Technology > Industrial Communication > Industrial Ethernet > RUGGEDCOM Ethernet Switches > RUGGEDCOM RS900 managed

Connectivity Quick Reference

Product names mentioned in this manual may be trademarks or registered trademarks of those products.

ETHERNET FIBER OPTIC CONVERTERS

6GK6022-8AS Automation Technology > Industrial Communication > Industrial Ethernet > RUGGEDCOM Ethernet Switches > RUGGEDCOM RSG2000 managed

Cisco Series Gigabit Ethernet Half-Height Line Card

Cisco Prisma II Platform

Cisco SGE Port Gigabit Switch Cisco Small Business Managed Switches

4 10/100/1000T Mini-GBIC with 4 IEEE 802.3at High Power PoE Industrial Wide Temperature Switch. User Manual SISTP LRT

FVT Slot Media Converter Chassis w/ Redundant Power User Manual

This provides an easily configurable solution, flexible enough to meet the specific requirements of a broad range of applications.

Automation Technology > Industrial Communication > Industrial Ethernet > RUGGEDCOM Ethernet Switches Layer 3 / Routers > RUGGEDCOM RX1000 managed

ICPDAS FSM-510G Series Ethernet Management Switch Quick Start

RightWON Satellite Ethernet switch module (ESM), multi-mode

PT-7728/7828 Quick Installation Guide

Gigabit Ethernet Micro Switch 5 Port

OmniConverterTM. OmniConverter GPoE+/Sx KEY FEATURES. Unmanaged 10/100/1000 Power Source Equipment (PSE) PoE/PoE+ Ethernet Fiber Switch

Optimux-34 Fiber Optic Multiplexer

Prisma II Platform. Optoelectronics

M727xS 10/100BaseTX-FX Selectable Media Converter Installation Guide

Preface. Managed Media Converter Chassis System

Installing the Cisco 2524 and Cisco 2525 Routers

Specifications FOX Matrix 3200/7200/14400/320x Series, SMX 88/1616 FOX

Conettix ITS-D6686-UL PRELIMINARY. Installation Guide. Ethernet Network Adapter

Conettix ITS-D6686-UL

Automation Technology > Industrial Communication > Industrial Ethernet > RUGGEDCOM Ethernet Switches > RUGGEDCOM RS900 managed

Optimux-4T1 Four-Channel T1 Multiplexer

Loop-O9330 Fiber Optical Mux

Media Converters & Chassis

GigaVUE-2404 // Data Sheet

V C ALIANT OMMUNICATIONS. VCL-Gigabit Optical Add-Drop Multiplexer. Product Brochure U.S.A. U.K. INDIA

F8008. Fiber Modem for up to 4E1 /8E1 +RS232+Ethernet. + optional V.35/QFXS/QFXO

KSD-800 Series. Installation Guide. Industrial 8-Port Fast Ethernet Switches with Fiber Connectivity DOC A -1-

INDUSTRIAL 1000BASE-T TO 1000BASE-X MEDIA CONVERTERS. KCD-400 Series. Installation Guide

AS1008-P AS1026-P AS2008-P AS2024-P User Manual

FCD-155. STM-1/OC-3 Terminal Multiplexer FEATURES

NOVASwitch Series. FNSW-8086F FNSW-8088F Fast Ethernet Fiber-optic Switch

ProCurve Switch 2600 Series

Loop-O 9300 Fiber Optical Mux

6GK6050-0MM Transmission rate. Interfaces

CISCO SRW208MP-EU SWITCH 8 x 10/100 PoE /100/1000 mini-gbic porttia, WebView/ Max PoE

16-SLOT IN-BAND MANAGEMENT CHASSIS

Summit Virtual Chassis Design and Installation Guide

Automation Technology > Industrial Communication > Industrial Ethernet > RUGGEDCOM Ethernet Switches > RUGGEDCOM RS1600 managed

FRG-3105 Series Residential Gateway

10/100/1000T to Mini-GBIC Industrial Switch Converter 10/100/1000T to 1000SX/LX Industrial Switch Converter. AMG9011G-H (-40 to 75C) User Manual

Conettix ITS-D6686-INTL

CVH Slot Media Converter Chassis Quick Installation Guide

Optimux-34, Optimux-25

Fast Ethernet Converter. User Guide MICROSENS

Note: For BANDIT II, BANDIT III, or VSR-1200 specifications, see the BANDIT II, BANDIT III, and VSR-1200 Document Set. Function

Optimux-1553 STM-1/OC-3 Terminal Multiplexer

Managed 100 Mbps Ethernet Switches TOP FRONT. Click 340/341/342

Hardened PoE Ethernet Switch

PT-7728 Series. IEC G-port Gigabit modular managed Ethernet switch. Introduction PT-7728

Ixia Net Optics ibypass 1Gb Fiber

C H A P T E R Figure 1-1 Modular Stacked Network System 1-1

PHB-200M PHB x 100/1000Base-T to 20x 100/1000Base-X

enetworks TM C2C Hardware Description and Specifications A.1 C2C Chassis Hardware Description

Rugged MediaConverter

RuggedNet. RuggedNet GPoE+/Mi KEY FEATURES. Managed Industrial 10/100/1000 Power Source Equipment (PSE) PoE/PoE+ Ethernet Fiber Switch

SOLO NETWORK (11) (21) (31) (41) (48) (51) (61)

16-Port Chassis Media Converter System Manual

Transcription:

CHAPTER 1 Product Overview The CDDI/FDDI C1400 Concentrator is a member of a family of concentrators that provide Copper Distributed Data Interface/multilevel transmission (CDDI/MLT-3) and single and multimode Fiber Distributed Data Interface (FDDI) connectivity. This concentrator combines the best features of compact, workgroup-style concentrators with the flexibility of chassis-style concentrators. Note Throughout this document, the CDDI/FDDI C1400 concentrator is also referred to as the Workgroup WS-C1400 concentrator or C1400. The term CDDI refers specifically to the CDDI/MLT-3 encoding scheme. CDDI and FDDI line cards can be mixed and added as needed, up to a maximum of 32 ports. Optional line cards are available that provide from 8 to 16 additional ports per card. Ports 1 and 2 of the line card installed in slot 1 can be configured as A/B ports that comply fully with the FDDI American National Standards Institute (ANSI) draft specification for A and B ports. Following are the available concentrator models: WS-X1441 8 multimode, MIC connector, FDDI ports WS-X1444 8 single-mode, ST connector, FDDI ports WS-X1450 2 multimode, MIC connector, FDDI ports and 12 RJ-45 connector, CDDI/MLT-3 ports WS-X1455 10 multimode, SC connector, FDDI ports WS-X1483 16 RJ-45 connector, CDDI/MLT-3 ports Product Overview 1-1

Summary of Features You can place concentrators on a desktop or mount them in an Electronic Industries Association (EIA) compliant, 19-inch open or closed rack. Summary of Features Following are the features of the Workgroup WS-C1400 Concentrator: Easy installation, configuration, and management Single attachment, dual attachment, or null attachment operation Dual Media Access Control (MAC) and three-path architecture Ring and port LED status indicators A visual traffic-meter LED Power-up diagnostics Concentrator administration through a local Electronics Industries Association/Telecommunications Industry Association (EIA/TIA)-232 port called the admin. interface port Note EIA/TIA-232 was known as recommended standard RS-232 before its acceptance as a standard by the Electronic Industries Associations (EIA) and Telecommunications Industry Association (TIA). Telnet support for remote login to the admin. interface Password protection for the admin. interface Ability to download new software through the admin. port using Kermit or over the network from the concentrator through a download server via the Trivial File Transfer Protocol (TFTP) Nonvolatile memory for software configuration data Support for an external optical bypass switch 1-2 CDDI/FDDI C1400 Concentrator Installation and Configuration Guide

Front Panel Simple Network Management Protocol (SNMP) agent that supports Management Information Base (MIB) II, FDDI MIB, and a Cisco MIB Bootstrap Protocol (BOOTP) support so the concentrator can get its Internet Protocol (IP) address from a BOOTP server on the network Company and IP aliases Ringmap display Ability to generate traffic on FDDI networks Port control: enable, disable, start, and stop ports Display remote MIB Workgroup WS-C1400 Concentrators comply fully with the FDDI Station Management (SMT) Specification, Revision 7.3 and include an SNMP agent for network management. A network administrator can monitor and control Workgroup Concentrators from anywhere on the network using any SNMP management application (for example, Workgroup Director network management software). Front Panel The front panel of the concentrator has LED indicators for concentrator, ring, and port status, and port traffic. (See Figure 1-1.) Figure 1-1 CDDI/FDDI Workgroup WS-C1400 Concentrator Front-Panel View TM H2470 Product Overview 1-3

Front Panel Front Panel LEDs The LEDs on the front panel of the concentrator (see Figure 1-2) indicate the status of the concentrator (faulty or not faulty), the status of the ring, the configuration state of the dual ring, and the status of each port. Figure 1-2 LED Indicators Partial Front-Panel View STATUS RINGOP THRU WRAP A WRAP B 1 2 Slot 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 TRAFFIC % 1/A 2/B 3 4 5 6 7 8 9 10 Slot 1 11 12 13 14 15 16 1 25 50 75 100 H2472 Following are descriptions of the status, ringop, thru, wrap A, wrap B, link status, and traffic-meter LEDs. Note All LED indicators except the traffic meter are duplicated on the back panel next to cable connections for easy diagnosis and monitoring. (See the section Rear Panel for a detailed description of the LEDs.) Status The concentrator performs a series of self-tests and diagnostics. The status LED indicators are as follows: Green The concentrator has passed all tests. Orange A minor alarm; for example, one line card has failed and has to be replaced. Red A major alarm; for example, a motherboard has failed and you need to call a customer service representative. 1-4 CDDI/FDDI C1400 Concentrator Installation and Configuration Guide

Front Panel Ringop The ringop LED indicates which ring is operational. (See Table 1-1.) Table 1-1 Ringop LED Descriptions Color Green Orange Off Meaning Primary ring is operational (secondary ring may also be operational). Secondary ring is operational, primary ring is nonoperational. Both rings are nonoperational. This LED is labeled RO on the rear panel of the concentrator. Thru In thru mode, indicated by the green thru LED, ports 1/A and 2/B are connected to the primary and secondary paths. This LED is labeled TH on the rear panel of the concentrator. Wrap A In wrap A mode, indicated by the green wrap A LED, port 2/B is isolated and port 1/A is connected to the ring. This LED is labeled WA on the rear panel of the concentrator. Wrap B In wrap B mode, indicated by the green wrap B LED, port 1/A is isolated and port 2/B is connected to the ring. This LED is labeled WB on the rear panel of the concentrator. Link Status The link status LEDs, slot 1 (labeled 1/A, 2/B, and 3 through 16) and slot 2 (labeled 1 through 16) indicate the connection state of each link. Table 1-2 describes what the LEDs indicate. Product Overview 1-5

Front Panel Note Slot 1 LEDs labeled 1/A and 2/B can be configured by software as A and B ports. Table 1-2 Link Status LED Descriptions Color Green Orange Off 1. M = master port. Meaning The link has connected properly with the remote device. Signal detected, but the link has failed to connect or is in the process of connecting. A dual homed station causes the link status LEDs of both the homing station M 1 port and the dual homed station A port to be orange. No signal detected. Traffic Meter The traffic-meter LED provides a visual indication (as an approximate percentage) of the current traffic load on the primary ring. (See Figure 1-3.) 1-6 CDDI/FDDI C1400 Concentrator Installation and Configuration Guide

Rear Panel Figure 1-3 Traffic Meter LED Traffic Meter Load % 90-100 80-89 70-79 60-69 50-59 40-49 30-39 20-29 10-19 1-9 H2173 Rear Panel The rear panel has two slots for line cards. The slots each accommodate a line card with from 8 to 16 M ports for connecting to CDDI or FDDI A, B, or slave (S) ports. There is an AC power receptacle, an optical bypass switch connector and LED, and an EIA/TIA-232 port for the admin. interface. (See Figure 1-4.) Product Overview 1-7

Rear Panel Figure 1-4 CDDI/FDDI Workgroup WS-C1400 Concentrator Rear-Panel View Power 110/230 VAC 2.5/1.6A 50/60 Hz Reset button H2521 1-8 CDDI/FDDI C1400 Concentrator Installation and Configuration Guide

Rear Panel AC Receptacle The AC power receptacle uses the AC power cord supplied with the concentrator. The power supply automatically accepts either 110 VAC or 230 VAC. To apply power, attach the power cord. To disconnect power, remove the power cord. Optical Bypass Switch Connector The six-pin mini-din connector is used to connect an external optical bypass switch to the concentrator. An activated bypass switch inserts the concentrator into the ring. An optical bypass switch can only be used with a line card in slot 1 and ports 1 and 2 configured as A/B ports. If you install or remove an optical bypass switch, you must reset the concentrator. Rear Panel LEDs The LEDs on the rear panel of the concentrator (see Figure 1-4) duplicate the LEDs on the front panel and indicate the status of the concentrator (faulty or not faulty), the status of the ring, the configuration state of the dual ring, and the status of each port. (See the section Front Panel LEDs earlier in this chapter.) Administration Interface Port To use the administration interface port (called the admin. interface), you can connect an EIA/TIA-232 terminal, modem, or workstation to the admin. port. You can also access the admin. interface from a remote host using Telnet. An RJ-45 cable and RJ-45-to-DB-25 data terminal equipment (DTE) adapter are provided for the admin. port. Refer to the appendix Cabling Specifications for the admin. port pinout. Note You have access to one Telnet or admin. interface connection per concentrator. Product Overview 1-9

Rear Panel Reset Button You can access the reset button through a small hole above the optical bypass switch connector. Using a thin tool, such as a paper clip, press the button, then release it to reset the concentrator. (See Figure 1-5.) Figure 1-5 Reset Button Partial Rear-Panel View 11 12 13 14 8 9 10 11 12 13 14 1 2 3 4 5 6 7 8 9 10 11 12 13 14 WS-X1450 STATUS WS-X1450 STATUS WA WS RO TH STATUS BYPASS ADMIN Reset button 11 12 13 14 1 2 3 4 5 6 7 H2471 Line Card Slots The line card slots (see Figure 1-6) support five optional CDDI and FDDI line cards, which are shown in Figure 1-6. The appendix Installing and Removing Line Cards contains procedures for installing and removing the line cards. The optional line cards are as follows: WS-X1441 8-multimode, MIC connector, FDDI ports (See 1 in Figure 1-6.) WS-X1444 8-single-mode, ST connector, FDDI ports (See 2 in Figure 1-6.) WS-X1450 2-multimode, MIC connector, FDDI ports, and 12-RJ-45 connector, CDDI/MLT-3 ports (See 3 in Figure 1-6.) WS-X1455 10-multimode, SC connector, FDDI ports (See 4 in Figure 1-6.) WS-X1483 16-RJ-45 connector, CDDI/MLT-3 ports (See 5 in Figure 1-6.) 1-10 CDDI/FDDI C1400 Concentrator Installation and Configuration Guide

Rear Panel Figure 1-6 CDDI and FDDI Line Cards 1 WS-X1441 2 WS-X1444 3 WS-X1450 4 WS-X1455 5 WS-X1483 H2500 Figure 1-7 shows a concentrator with both CDDI line cards installed. Product Overview 1-11

CDDI-FDDI Translator Figure 1-7 Concentrator with CDDI Line Cards Installed Rear-Panel View H2522 CDDI-FDDI Translator The CDDI-FDDI translator allows you to connect a device with an FDDI interface to a CDDI twisted-pair network. The translator has an FDDI media interface connector (MIC) M port to connect to the FDDI station and a CDDI port to connect to the concentrator or wall plate with a modular cable. The CDDI-FDDI translator includes an AC power adapter. Figure 1-8 shows the translator (Model Number WS-X703). Figure 1-8 FDDI port CDDI-FDDI Translator CDDI port FSD PWR CSD CDDI port FDDI port POWER H2112 There are three status LEDs on the side of the concentrator: FSD (FDDI signal detect), PWR (power), and CSD (CDDI signal detect). 1-12 CDDI/FDDI C1400 Concentrator Installation and Configuration Guide

Technical Specifications Technical Specifications Table 1-3 lists specifications for the CDDI/FDDI Workgroup WS-C1400 Concentrator. Table 1-3 CDDI/FDDI Workgroup WS-C1400 Concentrator Specifications Specification Description Physical Width: 18'' (45.72 cm) Depth: 16'' (40.64 cm) Height: 2.7'' (6.86 cm) Weight: 16 lb (7.3 kg) Power requirements 3.0A @ 110 VAC, 60 Hz 1.6A @ 220 VAC, 50 Hz Thermal dissipation FDDI: 90W (maximum) CDDI: 110W (maximum) Operating temperature 32 to 104 F (0 to 40 C) Storage temperature 40 to 167 F ( 40 to 75 C) Relative humidity 10% to 90% noncondensing Electromagnetic emissions certifications CDDI/FDDI: FCC Class A (47 CFR, Part 15) CDDI/FDDI: CISPR 22 Class A CDDI/FDDI: VCCI Class I FDDI: VDE Class B Safety UL: 1950 CSA-C22.2 No. 950-M89 IEC 950 Mounting Desktop 19-inch rack (hardware included) Connectors Multimode FDDI: MIC Multimode FDDI: SC Single-mode FDDI: ST CDDI: RJ-45 Admin. port: RJ-45 Product Overview 1-13

Technical Specifications Specification Ports 8-port multimode FDDI line card 8-port single-mode FDDI line card 2-port multimode FDDI and 12-port CDDI/MLT-3 line card 10-port multimode FDDI line card 16-port CDDI/MLT-3 line card Admin. interface port (EIA/TIA-232) Fiber interface 62.5/125-micron multimode fiber 50/125-micron multimode fiber 8/125-micron single-mode fiber Network management SMT 7.3 SNMP agent (RFC 1157) FDDI MIB (RFC 1285) MIB II (RFC 1213) Workgroup-specific MIB LED indicators Concentrator status Ringop Thru Wrap A Wrap B Traffic meter Link status (each link) Maximum station-to-station cabling distance FDDI transmit power levels: Single-mode fiber Description 62.5/125 micron multimode fiber: 1.24 miles (2 km) 50/125 micron multimode fiber: 1.24 miles (2 km) 8/125-micron single-mode fiber: 18.6 miles (30 km) Category 5 UTP 1 : 328' (100 m) IBM Type 1 or Type 2 STP 2 : 328' (100 m) Average optical power: Maximum: 4.0 dbm 3 Minimum: 7.0 dbm Multimode fiber Maximum: 14.0 dbm Minimum: 18.5 dbm 1-14 CDDI/FDDI C1400 Concentrator Installation and Configuration Guide

Technical Specifications Specification FDDI receive power levels: Single-mode fiber Multimode fiber 1. UTP = unshielded twisted-pair. 2. STP = shielded twisted-pair. 3. dbm = decibels per milliwatt. Description Average optical sensitivity: 33 dbm Average maximum input power: 14 dbm Average optical sensitivity: 34 dbm Average maximum input power: 14 dbm Product Overview 1-15

Technical Specifications 1-16 CDDI/FDDI C1400 Concentrator Installation and Configuration Guide