Designed for commercial, residential and industrial applications, guarantee rapid installation with few and easy connections.

Similar documents
VMU-MC and VMU-OC. Pulse concentrator. Benefits. Description

EM270. Multi-channel power analyzer. Benefits. Description

EM271. Multi-channel power analyzer. Benefits. Description

AB Axis Industries. Use

How to monitor M-Bus and wireless M-Bus systems

WM20. Power analyzer for three-phase systems. Benefits. Description

Multichannel power analyzer for single, two and three-phase systems

BACnet Controller for General-purpose Building Applications

AIAS. Technical description

mark150s mark150/485s DDC controllers Summary

Energy Management Modular DC Energy analyzer Type VMU-E and VMU-X

Energy Management BUS Adapter Type VMU-B 01

CMi- box. M-Bus Metering Gateway for Mobile Network GSM/GPRS TCP/IP. CMi-Box

Signal Doublers. VariTrans A 20300

M-bus web server. Meters and Energy Cost Allocation WTV676-HB6035

SA2WEB24. Central unit module. Benefits. Description

MODEL: GR8-EM. Communication Adaptor GR8 Series

ZBRN1 access point- 2 RJ V AC/DC-4 displays-5 LEDs-Eth-Modbus-wireless radio

iologik E1200H Series

ProData DATA LOGGER. Chapter 03 ProData data logger. Ethernet. Pulse inputs and Pulse outputs. Modbus-Ethernet gateway. Thermistor input.

UC102 basic version with display and knob UC102BL version with display, knob and backlight UC102DK version without knob and display

DKG-210 UNIVERSAL INTERNET GATEWAY UNIT

SensoTrans DMS A 20220

NetCom Plus 111 (NetCom 111)

Energy Management Energy Transducer Type ET112

MODEL: R1M-A1. PC Recorders R1M Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.)

Operating and mounting instructions

Energy meters Single phase electrical energy meters WM1-6 / WM1M6

SB2WEB24. SB2WEB BACnet Controller. Benefits. Description

ZBRN1 access point- 2 RJ V AC/DC-4 displays-5 LEDs-Eth-Modbus-wireless radio

ProData data logger. Ethernet. Pulse inputs and Pulse outputs. Thermistor input. Modbus-Ethernet gateway. Memory 32 MB. Threshold value monitoring

Energy Management BUS Adapter Type VMU-B

XPSMCMCO0000EM Modbus TCPIP diagnostic expansion module with screw term

SH2WEB24. Central unit module. Benefits. Description

Features and Benefits. Certifications

NetCom Plus 113 (NetCom 113, NetCom 113 PRO)

MODEL: WL40EW2F. Wireless I/O WL40F Series

OnCell G3150A-LTE Series

Dual Channel Monitor for Measurement of Speed and Ratio with SIL1 requirements Series D224.xx

MODEL: R1M-D1. PC Recorders R1M Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.)

QXA2000 QXA2001. Condensation Monitor QXA2001 QXA2000 AQX2000

Communicative controller for VAV systems

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

RM35JA32MR Current control relay 0.15A 15A, 2 C/O

Diaphragm gas meters with Absolute ENCODER

Your process requires the utmost attention Our new ACT20C signal conditioners support you in achieving this

Network nodes with gateway

TM200CE24T controller M IO transistor Source+ Ethernet

RE22R1QMQ star-delta timing relay - 230VAC/440VAC - 1 C/O

OHIO SEMITRONICS, INC. AC MULTIFUNCTION PROGRAMMABLE TRANSDUCERS & -1000L

ZBRN1. Main. Device short name

General information Engineering with Programming package. Display with display

IMIO100 IMIO105. DDC controllers. Summary

Waterproof Electrical Junction Box Kits Technical Data Sheet

XPSMF40. Main. Safety module name. Monitoring safety detection discrete input Monitoring safety dialogue discrete output

XPSMF35. Product data sheet Characteristics. Preventa safety PLC compact - Profibus DP protocol. Main. Complementary. Safety module name

QUICKSTART Smart EnOcean Gateway DC-GW/EO-IP

M-bus RF gateway. Meters and Energy Cost Allocation WTT563-0C0000

MCX08M2 Programmable controller

UMG 20CM. 20 Channel Branch Circuit Monitoring Device with RCM

Three-phase electricity meter with instantaneous reading of electrical variables. Input current measurement: 5 A, 90 A, 150 A, 250 A (span by model).

SonoMeter 30 Ultrasonic energy meter for heating and cooling applications

MODEL: IT40SW2. Tower Light Series. [2] LAMP 1 COLOR (1st layer from the top) R: Red Y: Amber G: Green B: Blue W: White

General information. Display. Supply voltage. Input current. Encoder supply. Output current. Power loss. Memory

AEW36.2. Pulse Adapter. Building Technologies. Siemeca AMR

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

iologik E1200 Series Ethernet remote I/O with 2-port Ethernet switch Introduction Remote I/O Daisy-Chained Ethernet I/O Connection

protocol can be used. The SB2WEB24 is also equipped with an RS485 port for communication

RE17LAMW on-delay timing relay - 1 s..100 h V AC/ DC - solid state output

Operating instructions. Switching amplifier DN0210 DN / / 2015

CompactBlock Guard I/O EtherNet/IP Safety Modules

RM35UB3. Product data sheet Characteristics. voltage control relay RM35-U - range V AC. Main. Complementary

RE22R1QMQ star-delta timing relay - 230VAC/440VAC - 1 C/ O

Model Number Structure

MW5501C Series MW5502C Series. 1 or 2-Port Industrial Wireless Modbus TCP/RTU/ASCII Gateway FEATURE HIGHLIGHTS PRODUCT DESCRIPTION

w w w. z i g s e n s e. c o m. a u

RM35TF V AC

General information Engineering with Programming package. Display with display. Supply voltage 24 V DC Yes. Input current

G3PC. Model Number Structure. Solid State Relays with Failure Detection Function. Model Number Legend

Energy Management Modular DC Energy analyzer Type VIM-E and VIM-X

Features and Benefits. Certifications

IAP-320 series are reliable a/b/g WLAN Access Point with 2 ports LAN. It supports 802.1X and MAC filters for

Level sensor Stainless steel version Model RLT-1000, for industrial applications

Com X 210, Com X 510 Technical Datasheet

Motor controllers CMMO-ST

RM22LA32MR Level control relay RM22-L V AC/DC - 2 C/O

CLIMATIX STEQ, STCM DATASHEET FOR CONTROLLING, SWITCHING AND MONITORING FUNCTIONS. POWER SUPPLY RELAY OUTPUTS. Power supply. 4.

RM17UB3. Product data sheet Characteristics. voltage control relay RM17-U - range V AC. Main. Complementary

Output Voltage* (nom.)(adjustable)

AEW Pulse Adapter. Building Technologies

WI-I/O 9 Multi I/O Units

LoRaWAN Pressure / Level and Temperature Sensor

PHS Series. PowerHUBB Node - Satellite

ATV310H075N4E variable speed drive ATV kw - 1 hp V - 3 phase

D5 SERIES WIRELESS SYSTEM

XPSMC16ZCPACK safety controller XPS-MC - 24 V DC - 16 input - 32 LEDs signalling

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

LMC058LF42 compact base - 42 I/O - 24 V DC supply

RS232C/RS485 Data can be easily monitored by LAN

Gateway, routing data between sensors and cloud

Transcription:

Gateways from M-Bus/wM-Bus to Modbus TCP/IP Benefits SIU-MBMs are gateways that transform data from the M-Bus and wireless M-Bus protocol into the Modbus TCP/IP protocol, to then send them to a master. Two versions are available: SIU-MBM-01 and SIUMBM-02. Both can integrate up to 20 wired M-Bus devices, while SIU-MBM-02 is also able to manage up to 32 wireless M-Bus devices simultaneously. Moreover, thanks to the SIU-MBC radio transmitter, SIU-MBM-02 can read consumption of devices with pulse output such as gas or water meters. The UCS software, available for free download, scans and identifies the M-Bus devices connected to SIU-MBM and the wireless M-Bus devices operating withing the range, automatically generating the Modbus map. For rapid and automatic integration with the VMU-C EM master, UCS generates a Modbus driver that can be imported directly. Simple integration. SIU-MBMs integrate all devices that communicate with the standard M-Bus protocol, wired and wireless. Thanks to the SIU-MBC radio transmitter, they can also read data of devices with pulse outputs. Product sold and usable individually. The products and the master VMU-C EM have been created to be integrated in the same system, where necessary, and designed to operate efficiently together. However, they may be sold and used individually as well. Ease of installation. SIU-MBMs can be installed on DIN rail. SIU-MBC can be installed on DIN rail or wallmounted by means of screws or tube/mast mounted by means of zip ties and it is suitable also for outdoor installation. Tamper-proof. Subsequent modifications to the configuration of SIU-MBC are blocked by means of the anti-fraud system. Free specific software. The UCS software enables rapid configuration with a simple and intuitive interface. The software and subsequent updates are free. Auomatic scanning and mapping. The UCS software automatically scans and maps the M-Bus devices present in the system. Automatic import of mapping into VMU-C EM. The UCS software is able to generate the driver to easily import the map of Modbus registers of all the integrated devices in the VMU-C EM master. Applications Designed for commercial, residential and industrial applications, guarantee rapid installation with few and easy connections. SIU-MBM is especially recommended for: retrofit applications in which data is to be collected from existing devices equipped for M-Bus or wireless M-Bus communication new installations in which M-Bus or wireless M-Bus devices are used, taking advantage of the ease of installation and integration. All consumption data (e.g. electricity, gas, water, heat) and ambient data (e.g. temperature and humidity) of a commercial or industrial building or a residential home can be integrated in the same VMU-C EM master, enabling the following: precise cost allocation 1

implementation of energy efficiency improvement policies check on correct operation and use of systems and machinery. Moreover, devices with pulse output not physically connectable to the master can be easily integrated in the system thanks to wireless communication of SIU-MBC, which can also be installed outdoors. Note: in case of connection to certified meters, we recommend checking for the possible need to make adaptations for the installation with the building owner or manager of the devices to be integrated. Main functions Collect data from multiple M-Bus and wireless M-Bus devices Convert data from M-Bus and wireless M-Bus into Modbus TCP/IP Communicate data to a Modbus master Scan devices and mapping (from UCS) Automatically import the map of Modbus registers into the VMU-C EM master, thanks to the driver generated by UCS Diagnose potential problems with wireless power and verify communication (from UCS) Decode data from wireless M-Bus devices via entry of decryption key (from UCS) 2

Architecture 3

Main features Up to 20 connected M-Bus devices (SIU-MBM-01 and SIU-MBM-02) Up to 32 wireless M-Bus devices (SIU-MBM-02) DIN rail mounting Wireless communication antenna (SIU-MBM-02) Ethernet Modbus TCP/IP output Free UCS software UCS specifications Intuitive interface 3-steps scanning and mapping process. Structure A B C D E F Fig. 1 SIU-MBM-01 Fig. 2 SIU-MBM-02 Area A B C D E F Power supply input terminal block M-Bus input terminal block Dip-switch for initial configuration LED Ethernet port (SIU-MBM-02 only) Antenna 4

Features General Material PVC Protection degree IP20 Terminals Cable section: from 0.5 to 3 mm2 Torque: 0.5 Nm Insulation See "Input and output insulation" on page 5 Mounting On DIN rail or wall-mounted Weight approx. 200 g Fig. 3 Fig. 1 SIU-MBM-02 dimensions Fig. 4 Fig. 2 SIU-MBM-01 dimensions Environmental specifications Operating temperature From -40 to + 85 C Storage temperature From -40 to + 85 C Input and output insulation Power supply and M-Bus port Power supply and Ethernet port M-bus and Ethernet port Not insulated 2000 V rms/0.5 ma/60 s 2000 V rms/0.5 ma/60 s 5

Conformity Directives Standards 2011/65/EU (RoHS - Restriction of Hazardous Substances) 2014/35/EU (LVD Low Voltage Directive) 2014/30/EU (EMC Electro Magnetic Compatibility) EN13757-3:2013 EN13757-4:2013 Approvals Power supply Power supply Consumption Connector From 15 to 21 V ac, from 18 to 35 V dc 3.5/4 W, 15 ma (with one device) Screw terminals LED SIU-MBM-01 LED ON M-Bus Modbus Gateway ON Reception of M-Bus communication Reception of Modbus communication LED SIU-MBM-02 LED ON wm-bus M-Bus Modbus Gateway ON Reception of wireless M-Bus communication Reception of M-Bus communication Reception of Modbus communication Ethernet port Protocols Modbus TCP/IP Connections Maximum 4 Connection type RJ45 connector Transmission speed Automatic detection 10/100 base-t M-Bus port Standard Protocols Connections Connection type Transmission speed EN13757-2:2013 M-Bus Maximum 20 devices Daisy chain or star connection Screw terminals From 300 to 38,400 bps 6

Wireless M-Bus communication (for SIU-MBM-02 only) Standard Protocols Connections Connection type Frequency EN13757-4 Wireless M-Bus Maximum 32 devices SMA connector for 868 MHz antenna (50 ohm) 868 MHz 7

Connection Diagrams 8

References Further reading Information Document Where to find it Instructions for installation, operation www.productselection.net/manuals/ Instruction manual - SIU-MBM-01 and maintenance UK/siumbm01_im.pdf Instructions for installation, operation www.productselection.net/manuals/ Instruction manual - SIU-MBM-02 and maintenance UK/siumbm02_im.pdf www.productselection.net/pdf/uk/ Datasheet VMU-C EM Datasheet vmucemds.pdf CARLO GAVAZZI compatible components Purpose Configure SIU-MBM and generate the Modbus map and driver for VMU-C EM Component name/part number UCS configuration software Notes Available for free download at: www.productselection.net/ Download/UK/ucs.zip Collect data from devices with pulse output SIU-MBC See next chapter Monitor data from several devices VMU-C EM See relevant datasheet 9

SIU-MBC Main functions Obtain data from devices with pulse output Transmit data from devices with pulse output in wireless M-Bus format for remote reading Main features Two pulse inputs Protection degree: IP67 Mechanical block with safety seal to ensure protection degree and prevent accidental opening Assembly with zip ties on tube/mast or wall-mounted with screws or on DIN rails Activation by magnet (not included) Communication via standard European wireless M-Bus protocol Battery-powered with built-in long life battery Anti-fraud system Radio trasmitter, easy to configure and ready for use, designed to count the pulses of devices with pulse output (meters for water, gas, electricity and heat) and to transmit the acquired consumption data in wireless M-Bus format for easy reading. Can manage up to two devices thus significantly reducing times and costs of installation. Compatible with wireless M-Bus gateways in the SIU-MBM range, and developed for integration in systems managed by VMU-C EM master. 10

SIU-MBC Structure Area A B C D E F G H Antenna Fixing supports Battery Screw terminals Cable input/output Dip-switch for configuration Seal Cable gland 11

Features SIU-MBC General Material Protection degree Connection to gateway Mounting Weight Plastic IP67 Wireless M-Bus Tube/mast mounted using zip ties DIN rail Wall-mounted using screws approx. 110 g Fig. 5 Fig. 3 SIU-MBC dimensions Environmental specifications Operating temperature From -20 to +75 C Storage temperature From -20 to +75 C 12

SIU-MBC Conformity Directives 2011/65/EU (RoHS - Restriction of Hazardous Substances) 2014/53/EU (RED - Radio Equipment Directive) Standards EN 13757-4:2005 Approvals Power supply Battery Recharge Lifetime Lithium, Li-SOCI2 Not possible 12 years Note: value referred to an operating temperature of 20 C and maximum one year of storage before use. Radio communication specifications Protocol Mode Frequency Data type Data transmission interval Encryption RF power Radio bandwidth Operating range Wireless M-Bus T1 868.95 MHz Selectable: water, gas, electricity, heat Selectable: 10 s, 10 min, 1 h, 12 h No 14 dbm (25 mw) 100 kbps up to 600 m in open air Digital inputs Number of inputs 2 Function Pulse count (water, gas, electricity, heat) Pulse weight Selectable: 1/10/100/1000 (Wh, dm3 or L) Maximum current 1 ma (open collector version) Maximum voltage 3.6 V Minimum pulse width 8 ms Maximum pulse frequency 33 Hz Input resistance 1 kω (dry contact version) Maximum cable length 10 metres Cable cross section From 0.25 to 0.5 mm 2 13

Connection Diagrams SIU-MBC Connections of a device and anti-fraud cable Connection of two devices and anti-fraud cables References Further reading Information Document Where to find it Instructions for installation, operation www.productselection.net/manuals/ Instruction manual - SIU-MBC and maintenance UK/siumbc_im.pdf M-Bus frame decoding M-Bus protocol www.productselection.net 14

SIU-MBC CARLO GAVAZZI compatible components Purpose Component name/part number Notes Convert data from wireless M-Bus to Modbus TCP/IP SIU-MBM-02 See previous chapter How to order SIU-MBC Code SIU-MBC-XX Gateway from pulses to wireless M-Bus SIU-MBM Code SIU-MBM- 01 SIU-MBM- 02 Gateway from M-Bus to Modbus TCP/IP Gateway from M-Bus/wireless M-Bus to Modbus TCP/IP COPYRIGHT 2018 Content subject to change. Download the PDF: www.productselection.net 15